• Title/Summary/Keyword: Frost characteristics

Search Result 161, Processing Time 0.025 seconds

A Characteristics Study on the Visualization and Heat Transfer of the Frost Formation Structure Variation by Control Plate Surface Temperature (표면온도 제어에 의한 착상층 구조변화의 가시화 및 열전달 특성 연구)

  • Kim Kyung-Chun;Ko Choon-Sik;Jeong Jae-Hong;Ko Young-Hwan;Shin Jong-min
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.55-58
    • /
    • 2002
  • To control the frost formation, a temperature variation of the cooling plate and characteristics on hydrophilic and hydrophobic surfaces was attempted. As a temperature variation of the cooling plate, being closely related to the frost layer density of frost layer is found to be affected by the melting process inside the frost layer during the heating period. At characteristics on surface, completely different structures of frost are appeared in the initial stage of frost formation due to the difference in surface conditions, while those effects are vanished with time. It is found that the frost thickness, density and heat flux characteristics are closely associated with the frost structure.

  • PDF

Characteristics of Frost Formed on Heat Exchanger Fins of Non-Uniform Temperature Distribution (불균일한 온도분포를 갖는 열교환기 휜에서의 착상 특성)

  • An, Won-Jun;Kim, Jung-Soo;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.373-379
    • /
    • 2009
  • In this study, frosting experiment was conducted to investigate the characteristics of frost formed on heat exchanger fins of non-uniform temperature distribution. Temperature distribution and frost characteristics of a 2-D fin surface were investigated in the airflow direction and the direction perpendicular to airflow. Temperature gradient was very small in the airflow direction, while it was large in the direction perpendicular to airflow due to fin heat conduction. The variations of the frost thickness gradient and the frost density gradient in the direction perpendicular to airflow were significant. On the other hand, the temperature gradient on frost surface in the direction perpendicular to airflow was significant at the early stage of frosting, while it decreased gradually as time elapsed.

An Experimental Study on Frost Heaving Characteristics of Soil Stabilized with the Additives (안정처리토의 동상특성에 관한 실험적 연구)

  • Kim, Jae-Young;Ju, Jae-Woo;You, Byung-Ok;Yang, Sung-Kee
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.215-218
    • /
    • 2003
  • In order to study the frost heaving characteristics of soil stabilitized with a quick lime, a cement and a briquette ash, frost heaving tests were performed with 2 kinds of soil sampled at Chonbuk-Do area. Frost heaving of no-stabilizing soil compacted with water content greater than optimum water content was increased as the frost period was increased but in case of samples with water content smaller than optimum water content, the frost period gave no affect about increase and decrease of the frost heaving. Both frost heaving of stabilizing and no-stabilizing soil with water content greater than optimum water content was decreased with the increase of the repetition number of freezing and thawing. There was no increase or decrease of frost heaving in the frost heaving test after 5 times of freezing and thawing.

  • PDF

A study on the behavior of frost formation according to surface characteristics in the fin-tube heat exchanger (핀-관 열교환기의 표면특성에 따른 착상 거동에 관한 연구)

  • 류수길;이관수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.377-383
    • /
    • 1999
  • In this study, the behavior of frost formation according to surface characteristics in the fin-tube heat exchanger has been examined experimentally. The results show that the thickness of the frost which is attached to the hydrophilic heat exchanger becomes thin and the air pressure drop is smaller than that of bare aluminium heat exchanger However, the frost mass of hydrophilic heat exchanger is more than the bare one. Hence, high density frost is attached to hydrophilic heat exchanger. The sensible and latent heat flux of hydrophilic heat exchanger is bigger than that of bare one, but the increasing amount is very small and the improvement of thermal performance is also very small. The variation of fin-pitch of heat exchanger shows little influence on frost formation and hydrophilic heat exchanger loses its surface characteristics rapidly with increasing relative humidity.

  • PDF

A Numerical Analysis on the Characteristics of Frost Heaving at Road Pavement in Korea (국내 도로포장의 동상 특성에 대한 수치해석적 연구)

  • Kweon, Gi-Chul;Oh, Se-Boong;Kim, Hyung-Bae;Choi, Chang-Gyu
    • International Journal of Highway Engineering
    • /
    • v.5 no.2 s.16
    • /
    • pp.37-47
    • /
    • 2003
  • The basic study was performed on the mechanical analysis of frost and heave using program FROST by CRREL, U.S. army corps of engineers. The characteristics of frost heaving in pavement was analyzed by considering climate, pavement sections and subgrade soil conditions in Korea. Water tables were located at the depth of 0.35m, 2m and 3.35m from subgrade. Inputs were evaluated inevitably from the existing references. As a result frost heave and depth were evaluated with respect time. Maximum frost heave decreased lowering the water table and maximum frost depth was less than 15cm from subgrade. Frost action did not affect seriously on the analysis sections.

  • PDF

Assessment of the effect of fines content on frost susceptibility via simple frost heave testing and SP determination

  • Jin, Hyunwoo;Ryu, Byung Hyun;Lee, Jangguen
    • Geomechanics and Engineering
    • /
    • v.30 no.4
    • /
    • pp.393-399
    • /
    • 2022
  • The Segregation Potential (SP) is one of the most widely used predictors of frost heave in cold regions. Laboratory step-freezing tests determining a representative SP at the onset of the formation of the last ice lens (near the thermal steady state condition) can predict susceptibility to frost heave. Previous work has proposed empirical semi-log fitting for determination of the representative SP and applied it to several fine-grained soils, but considering only frost-susceptible soils. The presence of fines in coarse-grained soil affects frost susceptibility. Therefore, it is required to evaluate the applicability of the empirical semi-log fitting for both frost-susceptible and non-frost-susceptible soils with fines content. This paper reports laboratory frost heave tests for fines contents of 5%-70%. The frost susceptibility of soil mixtures composed of sand and silt was classified by the representative SP, and the suitability of the empirical semi-log fitting method was assessed. Combining semi-log fitting with simple laboratory frost heave testing using a temperature-controllable cell is shown to be suitable for both frost-susceptible and non-frost-susceptible soils. In addition, initially non-frost-susceptible soil became frost susceptible at a 10%-20% weight fraction of fines. This threshold fines content matched well with transitions in the engineering characteristics of both the unfrozen and frozen soil mixtures.

Prediction of Frost Layer Growth on a Cold Plate (저온 평판에서의 서리층 성장 예측)

  • Jhee, Sung;Lee, Kwan-Soo;Yeo, Moon-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1325-1331
    • /
    • 2002
  • This study presents a numerical model to predict the behavior of frost layer growth. The characteristics of the heat and mass transfer inside the frost layer are analyzed by coupling the air flow with the frost layer. The present model is validated by comparing with the several other analytical models. It has been known that most of the previous models cause considerable errors depending on the working conditions or correlations used in predicting the frost thickness growth, whereas the model in this work estimates the thickness of the frost layer more accurately within an error of 10% in comparison with the experimental data. Simulation results are presented for variations of heat and mass transfer during the frost formation and for the behavior of frost layer growth along the direction of air flow.

Numerical Study of Performance Variation Under Frost and Non-frost Condition of Refrigerating System in the Refrigerator Truck (냉동탑차용 냉장시스템의 착상 및 무착상 상태에서의 성능변화에 관한 해석적 연구)

  • Kim, Sang-Hun;Myung, Chi-Wook;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.733-740
    • /
    • 2011
  • To analyze the cooling performance in the refrigerator truck according to frost growth, the analytical model of refrigeration system was developed under frost and non-frost condition using EES. The system performance was analyzed with outdoor temperature, storage temperature, outdoor front air velocity and compressor speed in order to investigate the system performance characteristics with operating conditions. Besides, the system performance under frost condition was compared with that under non-frost condition. As a result, the frost thickness was 0.9 mm when the refrigerating capacity of frost condition was decreased by 30%. The maximum of the system COP was shown at compressor speed of 1500 rpm for non-frost and frost condition, simultaneously. The performance under frost condition was more sensitive to the operating condition compared to that under non-frost condition.

Frost Heaving Pressure Characteristics of Frozen soils with Frost-Susceptibility and Degree of Saturation (흙의 동상민감성과 포화도를 고려한 동상팽창압 특성)

  • 신은철;박정준;김종인
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.329-336
    • /
    • 2002
  • The earth structures and in-ground LNG tank, and buildings can be constructed with using artificial freezing method on the reclaimed land. In this study, upon freezing a saturated soil in a closed-system from the top, a considerable pressure was developed. The pressure is the result of the surface energy of a curved ice-water interface. The most significant of these parameters will have the greatest effect on the classification. In order to establish frost-susceptibility criteria based on frost heaving expansion pressure, more soils have to be tested. This study was initiated to investigate the soils frost heaving expansion pressure and moisture characteristics resulting from freezing and freezing-thawing cycle process. Weathered granite soils, sandy soil, sandy soil were used in the laboratory freezing test subjected to thermal gradients under closed- systems.

  • PDF

Experimental assessment of the effect of frozen fringe thickness on frost heave

  • Jin, Hyun Woo;Lee, Jangguen;Ryu, Byun Hyun;Shin, Yunsup;Jang, Young-Eun
    • Geomechanics and Engineering
    • /
    • v.19 no.2
    • /
    • pp.193-199
    • /
    • 2019
  • A frozen fringe plays a key role in frost heave development in soils. Previous studies have focused on the physical and mechanical properties of the frozen fringe, such as overall hydraulic conductivity, water content and pore pressure. It has been proposed that the thickness of the frozen fringe controls frost heave behavior, but this effect has not been thoroughly evaluated. This study used a temperature-controllable cell to investigate the impact of frozen fringe thickness on the characteristics of frost heave. A series of laboratory tests was performed with various temperature boundary conditions and specimen heights, revealing that: (1) the amount and rate of development of frost heave are dependent on the frozen fringe thickness; (2) the thicker the frozen fringe, the thinner the resulting ice lens; and (3) care must be taken when using the frost heave ratio to characterize frost heave and evaluate frost susceptibility because the frost heave ratio is not a normalized factor but a specimen height-dependent factor.