• Title/Summary/Keyword: Frost Height

Search Result 21, Processing Time 0.029 seconds

A Development of the Correlation for Predicting the Frost Height in Applying Photoelectric Sensors (광센서를 이용한 서리높이 예측 상관식 개발)

  • Jeon, Chang-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.7138-7145
    • /
    • 2015
  • In this study, experiments were conducted to investigate the correspondence between the output voltage of the photoelectric sensor and the frost height under heating and defrosting capacity test condition (dry bulb temperature $2^{\circ}C$, wet bulb temperature $1^{\circ}C$) described at KS C 9306, where a real heat exchanger was used as a test rig instead of a large-scale model. A digital microscope and a photoelectric sensor unit consisting of an emitter and a transistor (receiver) were installed in the front of it. A linear correlation is proposed to predict the frost height based on 150 experimental data, approximately 54% of the measured data are consistent with the predicted frost heights within a relative deviation of ${\pm}10%$, it yields good agreement with 90% of the measured data when the frost height larger than 0.3mm with in a relative deviation of ${\pm}10%$. Compared with Xiao's correlation, the slope namely, the change of frost height in accordance with the change of output voltage is consistent within the error of 2.3%. But vertical intercept shows big difference with Xiao's correlation, because it was developed with a large scale model instead of a real heat exchanger.

Experimental assessment of the effect of frozen fringe thickness on frost heave

  • Jin, Hyun Woo;Lee, Jangguen;Ryu, Byun Hyun;Shin, Yunsup;Jang, Young-Eun
    • Geomechanics and Engineering
    • /
    • v.19 no.2
    • /
    • pp.193-199
    • /
    • 2019
  • A frozen fringe plays a key role in frost heave development in soils. Previous studies have focused on the physical and mechanical properties of the frozen fringe, such as overall hydraulic conductivity, water content and pore pressure. It has been proposed that the thickness of the frozen fringe controls frost heave behavior, but this effect has not been thoroughly evaluated. This study used a temperature-controllable cell to investigate the impact of frozen fringe thickness on the characteristics of frost heave. A series of laboratory tests was performed with various temperature boundary conditions and specimen heights, revealing that: (1) the amount and rate of development of frost heave are dependent on the frozen fringe thickness; (2) the thicker the frozen fringe, the thinner the resulting ice lens; and (3) care must be taken when using the frost heave ratio to characterize frost heave and evaluate frost susceptibility because the frost heave ratio is not a normalized factor but a specimen height-dependent factor.

Experimental Assessment and Specimen Height Effect in Frost Heave Testing Apparatus (동상시험장비의 실험적 검증 및 시료크기의 영향에 관한 연구)

  • Jin, Hyunwoo;Ryu, Byunghyun;Lee, Jangguen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Frost heave is one of the representative engineering characteristics in cold regions. In South Korea, which is located in seasonal frost area, structural damage caused by frost heave and thaw happens and the need for research on the frost heave is increasing. In this paper, newly developed transparent temperature-controllable cell is used to focus on the frost heave. Frost susceptible artificial soil is used to analyze water intake rate which is one of the important factors in frost susceptibility criteria. Frost heave rate and water intake rate have similar behavior after heave by freezing of pore water converges. O-ring installed in the upper pedestal to measure water intake rate generates side friction between the inner wall of the freezing cell and O-ring, thereby hindering frost heave. Therefore, the frost susceptibility criteria using the water intake rate is not reliable. It is appropriate to use frost heave rate which has similar behavior with water intake rate. Frost heave tests were performed under two different specimen heights. Overburden pressure, temperature gradient and dry unit weight were set under similar state. Based on laboratory testing results, frost heave is independent on the specimen height.

Evaluation of Frost Heave Prediction and Frost Susceptibility in Sample using JGS Test Method (일본 동상성판정기준을 적용한 시료의 동상예측 및 동상성 평가)

  • Kim, Young-Chin;Hong, Seung-Seo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.926-931
    • /
    • 2008
  • This paper show two different standardized test methods(Japanese Geotechnical Society; JGS 2003). One test is a "Test Method for Frost Heave Prediction Test, JGS 0171-2003", and the other test is a "Test Method for Frost Susceptibility, JGS 0172-2003". The purpose of this test is to obtain the freezing rate(freezing speed), frost heave ratio(heave to sample height), frost heave rate(heaving speed), and other parameters to be used for frost heave prediction and determine the frost susceptibility by freezing test with water intake. This method shall be used to predict the frost heave in frozen ground and evaluate the frost susceptibility of natural and replacement materials.

  • PDF

Investigation of Frost Reduction Effect using Mesh Net (그물망을 이용한 서리 저감 효과 구명)

  • Yu, Seok cheol;Kim, Yu yong;Lim, Seong yoon;Song, Ho sung
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.448-455
    • /
    • 2020
  • This study was carried out to investigate reduction of the frost damage using the mesh net used for the purpose of non-bagged cultivation. A device measuring the weight of frost was developed and installed in both the control and the experimental, and the effect of frost reduction was evaluated with their weights. As a result, weight of frost in the control was reduced from 37% to 59% with mesh net on the day the frost was observed. In addition, the device for automatically observing the amount of frost was developed and the height of the windbreak of the frost measuring device was determined to be 30 cm through wind tunnel experiment. The results of this study are expected to reduce frost damage during the flowering season of fruit trees by installing mesh net and it is expected to be used as basic data for agricultural use of mesh net.

Improvement of Multiple-sensor based Frost Observation System (MFOS v2) (다중센서 기반 서리관측 시스템의 개선: MFOS v2)

  • Suhyun Kim;Seung-Jae Lee;Kyu Rang Kim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.3
    • /
    • pp.226-235
    • /
    • 2023
  • This study aimed to supplement the shortcomings of the Multiple-sensor-based Frost Observation System (MFOS). The developed frost observation system is an improvement of the existing system. Based on the leaf wetness sensor (LWS), it not only detects frost but also functions to predict surface temperature, which is a major factor in frost occurrence. With the existing observation system, 1) it is difficult to observe ice (frost) formation on the surface when capturing an image of the LWS with an RGB camera because the surface of the sensor reflects most visible light, 2) images captured using the RGB camera before and after sunrise are dark, and 3) the thermal infrared camera only shows the relative high and low temperature. To identify the ice (frost) generated on the surface of the LWS, a LWS that was painted black and three sheets of glass at the same height to be used as an auxiliary tool to check the occurrence of ice (frost) were installed. For RGB camera shooting before and after sunrise, synchronous LED lighting was installed so the power turns on/off according to the camera shooting time. The existing thermal infrared camera, which could only assess the relative temperature (high or low), was improved to extract the temperature value per pixel, and a comparison with the surface temperature sensor installed by the National Institute of Meteorological Sciences (NIMS) was performed to verify its accuracy. As a result of installing and operating the MFOS v2, which reflects these improvements, the accuracy and efficiency of automatic frost observation were demonstrated to be improved, and the usefulness of the data as input data for the frost prediction model was enhanced.

Study on the Heat Transfer Numerical Analysis of Supper Low Temperature Liquefied Gas Vaporizer (초저온 액화가스용 기화기의 열전달 수치해석)

  • Lee, Yong-Hun;Ji, Myoung-Kuk;Park, Gi-Tae;Kim, Pil-Hwan;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2211-2216
    • /
    • 2007
  • Liquefied gas vaporizer means machine to vaporize the liquefied gas as liquid nitrogen($LN_2$), liquefied natural gas(LNG), liquid oxygen($LO_2$) etc. In the air type vaporizer, the frozen dew is also created by temperature drop (below 273 K) on vaporizer surface. This problem increases as the time progresses and humidity increases. In addition, the frozen dew gradually becomes frost deposit consequently, heat transfer through vaporizer decreases because frost deposit form adiabatic sheet. Because of this reason, recent vaporizer system is installed as parallel type, this vaporizer system needs more expensive installation costs and more space. This paper was investigated on the heat transfer characteristics of liquefied gas vaporizer with super low temperature and this paper was carried out the numerical about air heating vaporizer with super low temperature. The numerical analysis on the heat transfer was studied on the effect of geometric parameters of the vaporizer, which are length 1000 mm of 4fin75le type vaporizer. 4fin75le means number of fin is 4 and height of fin is 75 mm.

  • PDF

Development of a Small Sized Cymbidium Variety 'Snow Bell' with Light Pink Colored Flower and Frangrance

  • Kim, Mi-Seon;Park, Pue-Hee;Yae, Byung-Woo
    • Horticultural Science & Technology
    • /
    • v.32 no.3
    • /
    • pp.415-419
    • /
    • 2014
  • A Cymbidium variety 'Snow Bell' (C. kanran ${\times}$ C. Jack Frost) was developed at the National Institute of Horticultural & Herbal Science, Rural Development Administration in 2011. A cross between C. kanran with small-sized greenish colored flowers and C. Jack Frost with bright pink colored flowers, was conducted in 1999. Based on flower color, leaf shape, flower stalk, and vigor one line was selected. Evaluation and selection trials were conducted from 2006 to 2010. 'Snow Bell' has a light pink sepal (RHS, R56D), red lip (R56A) and a leaf length of 47.5 cm. The average number of flowers on each peduncle is 13.8 and the flower diameter is 6.2 cm. The characteristics of petals and sepals show some incurve and some spreading. 'Snow Bell' has a vigorous growth and a round flower. It has an adequate peduncle height of 50.7 cm compared with leaf length of 47.5 cm, and start blooming in December. In electronic nose analysis, the degree of fragrance between 'Snow Bell' and the C. kanran was similar and both of them showed strong scents, although they had different fragrance patterns.

3D Unsteady Numerical Analysis to Design Defrosting System of Automotive Windshield Glass (자동차 전면유리의 제상시스템 설계를 위한 3차원 비정상 수치해석)

  • Kang, Shin-Hyung;Lee, Jin-Ho;Byun, Ju-Suk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.1-8
    • /
    • 2007
  • The present research is based upon the numerical analysis of a car windshield in order to represent the optimum design guide to improve the overall defrosting performance of the system. First, the control factors that highly affect the defrosting performance of a car windshield are chosen and afterwards, the optimum variables of each control factor are extracted out to analyze its performance. The main control factors for this research are respectively, the air injection angle of a defroster nozzle, the height of a nozzle outlet, and the ratio of the width to the height of a nozzle outlet. For such case when the air inlet angle is relatively small, the flow near the vicinity of the inner face of a windshield tends to expand. As a consequence, the heat transfer rate through the windshield decreases. Also, the height of a nozzle outlet is recommended to maintain its size to minimum. However, when the ratio mentioned before is designed less than unity, the defrosting performance decreases.

Nocturnal temperature distribution on orange orchards in Cheju Island (II) (제주도 감귤 과수원의 야간 기온 분포(II))

  • ;;Lee, Seung-Ho;Lee, Hyong-Young
    • Journal of the Korean Geographical Society
    • /
    • v.30 no.3
    • /
    • pp.230-241
    • /
    • 1995
  • The Characteristics of nocturnal temperature fields were analyzed to understand the factors of freezing-and-cold damages on orange orchards in Cheju Island. Temperatures were measured from January 7th through 27, 1995 at 25 sites in an area of 1x1.25$ extrm{km}^2$, Wasan-ri, Chochon-up, Pukcheju-kun located on the northeastern slope of Mt.Hanla. Several other weather elements such as wind and cloud were observed as supplementary data. Surface weather maps were also analyzed to clarify the influence of prevailing pressure patterns on the temperature fields. The vertical temperature profiles were obtained at the height from the ground up to 360 cm in 30 cm intervals at site 3, a frost hollow, and site 10 on the upper slope. The results show that freezing damages occured in the hollows, terrain depressions, rather than at the upper slope due to nocturnal radiation cooling as well as accumulation of cold airflow from Mt.Hanla. Windbreaks of densely planted Japanese ceders with stone-walls also roled as obstacles to the cold airflow in nights with Clear skies and light winds. The maximum intensity of temperature inversion in hollows, quasi-cold air lake, was 3.1$^{\circ}C$. Cold air from Mt.Hanla was trapped in the depressions up to a height of 90cm forming frost pocket. Man-made facilities such as shelterbelt or stone-wall which are built to prevent the penetration of cold north-westeries in winter aggravated the cold damage. The differance of daily minimum temperatures between before and behind shelterbelts was 2.$0^{\circ}C$. The man-made convection by smudgin which raised the temperatures up to 3.8$^{\circ}C$ can reduce the cold damage in the hellows.

  • PDF