1 |
W. Wang, Y. C. Feng, J. H. Zhu, L. T. Li, Q. C. Guo, W. P. Lu, "Performances of air source heat pump system for a kind of mal-defrost phenomenon appearing in moderate climate conditions", Applied Energy, Vol. 112, pp. 1138-1145, 2013. DOI: http://dx.doi.org/10.1016/j.apenergy.2012.12.054
DOI
|
2 |
J. S. Byun, C. D. Jeon, J. H. Jung, J. Lee, "The application of photo-coupler for frost detecting in an air-source heat pump", Int. Journal of Refrigeration, Vol. 29, pp. 191-198, 2006. DOI: http://dx.doi.org/10.1016/j.ijrefrig.2005.06.008
DOI
|
3 |
R. W. Besant, K. S. Rezkallah, Y. Mao, J. Falk, "Measurement of frost thickness using a laser beam and light meter", ASHRAE Trans. Vol. 96 (1), pp. 519-522, 1990.
|
4 |
Y. Mao, R. W. Besant, H. Chen, "Frost characteristics and heat transfer on a flat plate under freezer operating conditions", ASHRAE Trans. Vol. 99 (1), pp. 231-251, 1999.
|
5 |
Z. L. Liu, H. Y. Wang, X. H. Zhang, S. Meng, C. F. Ma, "An experimental study on minimizing frost deposition on a cold surface under natural convection conditions by use of a novel anti-frosting paint. Part I. Anti-frosting performance and comparison with the uncoated metallic surface", Int. Journal of Refrigeration Vol. 29, pp. 229-236, 2006. DOI: http://dx.doi.org/10.1016/j.ijrefrig.2005.05.018
DOI
|
6 |
J. T. Kwon, H. J. Lim, Y. C. Kwon, S. Koyama, D. H. Kim, C. Kondou, "An experimental study on frosting of laminar air flow on a cold surface with local cooling", Int. Journal of Refrigeration Vol. 29, pp. 754-760, 2006. DOI: http://dx.doi.org/10.1016/j.ijrefrig.2005.12.009
DOI
|
7 |
B. Na, R. L. Webb, "New model for frost growth rate", Int. Journal of Heat Mass Transfer Vol 47, pp. 925-936, 2004. DOI: http://dx.doi.org/10.1016/j.ijheatmasstransfer.2003.09.001
DOI
|
8 |
J. Xiao, W. Wang, Y. H. Zhao, F. R. Zhang, "An analysis of the feasibility and characteristics of photoelectric technique applied in defrost control", Int Journal of Refrigerations, Vol. 32, pp. 1350-1357, 2009. DOI: http://dx.doi.org/10.1016/j.ijrefrig.2009.02.014
DOI
|
9 |
W. Wang, J. Xiao, Q. C. Guo, W. P. Lu, Y. C. Feng, "Field test investigation of the characteristics for the air source heat pump under two typical mal-defrost phenomena", Applied Energy, Vol. 88, pp. 4470-4480, 2011. DOI: http://dx.doi.org/10.1016/j.apenergy.2011.05.047
DOI
|
10 |
C. D. Jeon, D.S. Kim, S. J. Lee, "Feasibility study on a defrost control method by using a photoelectric sensors", Journal of the Korea Academia-Industrial cooperation Society Vol. 15, No. 6 pp. 3389-3395, 2014. DOI: http://dx.doi.org/10.5762/KAIS.2014.15.6.3389
DOI
|
11 |
C. D. Jeon, K. S. Jung "Frost sensing device and method", Korean Intellectual Property Office, Patent No. 10-1085691
|
12 |
J. Xiao, W. Wang, Q. C. Guo, Y. H. Zhao, "An experimental study of the correlation for predicting the frost height in applying the photoelectric technology", Int. Journal of Refrigeration, Vol. 33, pp. 1006-1014, 2010. DOI: http://dx.doi.org/10.1016/j.ijrefrig.2010.03.002
DOI
|
13 |
KS C 9306, Air conditioner, 2002.
|
14 |
KS B 6275, Reciprocating water-chillers, 2002.
|
15 |
K. S. Lee, "Frosting and defrosting characteristics of a fin-tube heat exchanger", Vol. 41, No. 10, pp. 36-43, 2012
|