• 제목/요약/키워드: Frost Control

검색결과 69건 처리시간 0.031초

표면온도 제어에 의한 착상층 구조변화의 가시화 및 열전달 특성 연구 (A Characteristics Study on the Visualization and Heat Transfer of the Frost Formation Structure Variation by Control Plate Surface Temperature)

  • 김경천;고춘식;정재홍;고영환;신종민
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.55-58
    • /
    • 2002
  • To control the frost formation, a temperature variation of the cooling plate and characteristics on hydrophilic and hydrophobic surfaces was attempted. As a temperature variation of the cooling plate, being closely related to the frost layer density of frost layer is found to be affected by the melting process inside the frost layer during the heating period. At characteristics on surface, completely different structures of frost are appeared in the initial stage of frost formation due to the difference in surface conditions, while those effects are vanished with time. It is found that the frost thickness, density and heat flux characteristics are closely associated with the frost structure.

  • PDF

폐타이어를 이용한 지반동상 방지 (The Control of the Ground Frost Heave by Using the Scrap Tire)

  • 김영진;강병희
    • 한국지반공학회지:지반
    • /
    • 제14권1호
    • /
    • pp.49-58
    • /
    • 1998
  • 폐타이어가 지반의 동상방지 건설재료로서 재사용될 수 있는지를 연구하였다. 동상방지에 대한 폐타이어의 기본적인 효과를 검토하기 위해 화강풍화토에 폐타이어가루를 몇 가지의 비율로 혼합해서 준비한 시료로서 영하 $17^{\circ}$하에서 동상시험과 화강풍화토에 대한 동결깊이시험을 실내에서 수행하였다. 역청포장의 보조기층 바로 아래에 폐타이어조각을 혼합한 쇄석층을 동상방지층으로 둠으로서 실용상으로 효과적이라는 사실을 알게 되었다. 그리고 이 동상방지 층의 소요두께와 동결 지수와의 관계식을 제안하였다.

  • PDF

그물망을 이용한 서리 저감 효과 구명 (Investigation of Frost Reduction Effect using Mesh Net)

  • 유석철;김유용;임성윤;송호성
    • 생물환경조절학회지
    • /
    • 제29권4호
    • /
    • pp.448-455
    • /
    • 2020
  • 본 연구에서는 서리의 피해 저감을 위하여 과수 무봉지 재배를 목적으로 사용하고 있는 그물망을 이용하고자, 서리의 양을 관측하는 장치를 대조구와 시험구에 설치하여 그 비교를 통해 서리 저감 효과를 구명하였다. 시험 결과 실제 서리가 관측된 날을 기준으로 시험구에서 37%에서 59%까지 저감 효과를 확인할 수 있었다. 또한 서리의 양을 자동으로 관측하는 장치를 개발하고 풍동실험을 통해 서리 측정 장치의 방풍함 높이를 30 cm로 결정하였다. 이러한 연구 결과는 그물망 설치함으로써 과수 개화기에 서리 피해를 저감할 수 있을 것으로 판단되며, 그물망의 농업적 이용에 대한 기초자료로 활용될 수 있을 것으로 기대된다.

도로 포장체에서 동상에 대한 지하수위 영향 평가 (Evaluation of Ground Water Level Effect on Frost Heaving in Road Pavements)

  • 권기철;이재환
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.47-56
    • /
    • 2013
  • PURPOSES: This study is to evaluate a ground water level effect on frost heaving in road pavements. METHODS: The effects of water table on frost heaving in pavement systems were evaluated from the mechanical analysis using FROST program. The input parameters and boundary conditions were determined by considering climates, pavement sections, and material properties specially subgrade soil types in Korea. RESULTS: When the water table located above the freezing depth, amount of frost heaving caused by freezing the water in pavement itself was big enough to damage in pavement system, although pavement system consists of fully non-frost-susceptible materials with sufficient thickness of anti-freezing layer. The amount of frost heaving was decreased rapidly with increasing the distance between the water table and freezing depth. CONCLUSIONS: It was concluded that there is no engineering problems related with frost heaving in practical sense when the distance between freezing depth and water table is over 1.5m for having subgrade soils less than 50% of #200 sieve passing to meet specification on quality control in Korea.

Effect of plastic film rain shelter installation in Asian pear orchards on frost and freeze damage and fruit quality

  • Hyeong-Seok Lee;Yu-Rim Kim;Young-Jik Ahn;Ho-Seok Son;Jong-Pil Chun
    • 농업과학연구
    • /
    • 제50권3호
    • /
    • pp.497-505
    • /
    • 2023
  • This study evaluated the impact of rain shelters made of plastic film on spring frost damage and fruit quality in Asian pears ('Niitaka') over two years. In 2021, during the coldest spring days (between 0:00 am and 7:00 am), temperatures dropped to -1.20 - 0.43℃ at 120 cm and -1.33 - 0.57℃ at 200 cm above ground level in the control. Conversely, the rain shelter treatment maintained higher temperatures, -0.40 - 0.87℃ at 120 cm and -0.43 - 0.77℃ at 200 cm. Flower damage was significantly lower in the rain-sheltered group, with incidences of 1.3 and 6.9% at 120 and 200 cm, respectively, compared with 18.1 and 22.6% in the control group. Visual observations verified the prevention of frost adhesion on flower organs in the sheltered group, compared with noticeable pistil death and petal browning in the control group. In 2022, when temperatures remained above 0℃, fruitlet stalk length was 5 - 6 mm longer in the sheltered group. The cumulative impact of rain shelters was evident in the improved fruit quality over the two years. This study suggests resilient cultivation strategies in the face of climate change to reduce frost damage, increase productivity, improve fruit quality, and potentially increase incomes of the farmers.

An Experimental Study on the Frost Prevention using Micro Liquid Film of an Antifreeze Solution

  • Chang Young-Soo;Yun Won-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권2호
    • /
    • pp.66-75
    • /
    • 2006
  • The effect of antifreeze solution liquid film on the frost prevention is experimentally investigated. It is desirable that the antifreeze solution spreads widely on the heat exchanger surface forming thin liquid film to prevent frost nucleation while having small thermal resistance across the film. A porous layer coating technique is adopted to improve the wettability of the antifreeze solution on a parallel plate heat exchanger. The antifreeze solution spreads widely on the heat exchanger surface with $100{\mu}m$ thickness by the capillary force resulted from the porous structure. It is observed that the antifreeze solution liquid film prevents a parallel plate heat exchanger from frosting. The reductions of heat and mass transfer rate caused by the thin liquid film are only $1{\sim}2%$ compared with those for non-liquid film surface.

교량구간의 결빙 예측 및 감지 시스템 (Bridge Road Surface Frost Prediction and Monitoring System)

  • 신건훈;송영준;유영갑
    • 한국콘텐츠학회논문지
    • /
    • 제11권11호
    • /
    • pp.42-48
    • /
    • 2011
  • 본 논문에서는 교량구간의 도로 결빙예측 및 감지를 위한 시스템 설계를 제안하였다. 센서 노드의 하드웨어는 마이크로프로세서, 온도 센서, 습도 센서, 그리고 Zigbee 무선 통신으로 구성되었다. 관제센터의 소프트웨어는 관제센터에 수집된 교량 온도, 습도 데이터로 관찰하기 위하여 구현되었다. 교량 노면의 결빙은 노면의 온도가 이슬점 온도 이하이면서 영하일 때 발생한다. 제안된 시스템을 이용하여 도로면의 온도 및 습도 분포를 측정하였다. 측정 데이터는 도로 결빙이 발생하는 시점을 예측하기 위하여 사용되었다. 실제 결빙되는 것보다 최소 30분 이전에 결빙시점을 예측하여 경고가 이루어진다. 이 결과로 결빙으로 인한 교통사고를 방지하기 위하여 사용 할 수 있다.

늦서리 피해 뽕나무의 엽면시비 효과 (Effect of Foliar Spray upon Mulberry Damaged by Late Frost)

  • 김종한;김동일
    • 한국잠사곤충학회지
    • /
    • 제32권2호
    • /
    • pp.89-93
    • /
    • 1990
  • 4월 27일 늦서리 피해를 받은 뽕나무에 요소 0.5% 수용액과 잠업시험장에서 개발한 잠비를 엽면에 4개엽기인 5월 16일부터 3일 간격으로 4회 시비하고 5월 18일부터 6월 12일까지 5일 간격으로 회복 정도를 조사한 결과 다음과 같았다. 1. 서리 피해 후 재발아한 덧눈은 평균 70개/주 내외였으며, 그루간에 최다치와 최소치 사이에는 3-4배 차를 보였다. 2. 5개엽기를 보인 5월 18일부터 25일간 최장신소장은 5.4배, 엽수는 2.1배, 신소엽량은 9.6배로 증가하였다. 3. 숨은 눈에서 발아하여 나온 신소엽량은 전신소엽량의 5% 정도로 수량에 큰 영향을 주지 않았다. 4. 서리피해로 최장신소장은 무피해 대비 26% 감소하였으며, 요소시비구는 10%, 잠비시비구는 1% 각각 무처리보다 증가하였다. 5. 최장신소장의 엽수는 서리피해로 5.2장 줄었으며, 무처리 보다 요소시비에 의해 8%, 잠비시비에 의해 각각 5% 증가되었다. 6. 신소엽량은 서리피해로 43% 감소되었고, 무처리보다 요소시비구는 7%, 잠비시비구는 6% 각각 증수를 보였다. 7. 정엽량은 서리피해로 47% 감소되었고, 무처리 보다 요소시비는 75, 잠비시비는 5% 증수를 보였다. 8. 10g당 수량을 보면 정상구에서 1.587kgdlsep 비해 서리피해구는 932kg으로 정상의 59%이었으며, 요소시비구는 1,070kg으로 68%, 잠비시비구는 1,033kg인 65%를 보였다. 9. 6월 12일 이후 수량은 일상 108kg/10a(3.5%)씩 증가하여 소잠을 4일 연기하고 요소엽면시비를 병용할 경우 정상 대비 82%까지 소잠이 가능할 것으로 추정되었다.

  • PDF

마이크로 부동액막을 이용한 착상방지에 관한 실험적 연구 (An Experimental Study on the Frost Prevention using Micro Liquid Film of an Antifreezing Solution)

  • 장영수;윤원남
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.459-467
    • /
    • 2005
  • The effect of anti freezing solution liquid film on the frost prevention is experimentally investigated. It is desirable that the antifreezing solution spreads widely on the heat exchanger surface forming thin liquid film to prevent frost nucleation and reduce the thermal resistance across the film. A porous layer coating technique is adopted to improve the wettedness of the anti freezing solution on a parallel plate heat exchanger. The antifreezing solution spreads widely on the heat exchanger surface with 100 $\mu$m thickness by the capillary force resulting from the porous structure. It is observed that the antifreezing solution liquid film prevents a parallel plate heat exchanger from frosting. The reductions of heat and mass transfer rate caused by thin liquid film are only $1\~2\%$ compared with those for non-liquid film surface.

부동액 도포에 의한 핀-튜브 열교환기 착상방지 (Frost Prevention of Fin-Tube Heat Exchanger by Spreading Antifreezing Solution)

  • 오상엽;장영수
    • 설비공학논문집
    • /
    • 제18권6호
    • /
    • pp.477-485
    • /
    • 2006
  • A study on frost prevention of fin-tube heat exchanger is experimently performed by spreading antifreezing solution on heat exchanger surface. It is desirable that the antifreezing solution spreads completely on the surface forming thin liquid film to prevent frost nucleation and crystal growth and to reduce the thermal resistance across the liquid film. A small amount of antifreezing solution falls in drops on heat exchanger surface using two types of supplying devices, and a porous layer coating technique is adopted to enhance the wettedness of antifreezing solution on the surface. It is observed that the antifreezing solution liquid film prevents fin-tube heat exchanger from frosting, and heat transfer performance does not degrade through the frosting tests. The concentration of supplied antifreezing solution can be determined by heat transfer analysis of the first row of heat exchanger to avoid antifreezing solution freezing due to dilution by moisture absorption.