• Title/Summary/Keyword: Fringe Tracking

Search Result 12, Processing Time 0.033 seconds

Authentic-color Characteristic of the Fringe-field Switching Mode using a Liquid Crystal with Negative Dielectric Anisotropy (유전율 이방성이 음인 액정을 이용한 Fringe-field Switching Mode의 Authentic-color 특성)

  • Song, Je-Hoon;Choi, Yoon-Seok;Moon, Dae-Gyu;Han, Jeong-In;Lee, Seung-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.633-640
    • /
    • 2004
  • We have studied color tracking of a fringe-field driven homogenously aligned nematic liquid crystal (LC) cell with negative dielectric anisotropy and compared it with other devices such as the twisted nematic(TN) and in-plane switching(IPS) modes. According to studies, the TN device shows bluish color at grey scale and even at a low retardation cell it cannot avoid color tracking. The authentic IPS device having cell retardation value of 0.23 ${\mu}{\textrm}{m}$ also shows bluish white color. However, the FFS device shows excellent color tracking characteristics even at high retardation value of the cell while keeping high transmittance and greenish white.

A Study on the Correlation Results for Fringe Rotation and Delay Tracking of the VCS (VCS의 지연추적과 프린지 회전에 대한 상관결과 고찰)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Oh, ChungSik;Jung, Jin-Seung;Chung, Dong-Kyu;Oyama, Tomoaki;Kawaguchi, Noriyuki;Kobayashi, Hideyuki;Kono, Yusuke;Ozeki, Kensuke;Onuki, Hirohumi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.220-232
    • /
    • 2012
  • In this paper, we investigate the correlation result due to the problems of delay tracking and fringe rotation module in the VCS(VLBI Correlation Subsystem). The VCS, FX-type correlator, adopts the delay tracking and fringe rotation module in order to compensate the delay change and fringe phase of wave signal from the radio source by Doppler's effect. The phase of observed data is also compensated by means of delay tracking and fringe rotation in the correlator, but we confirmed that the phase is unstable by applying long integration period of AIPS(Astronomical Image Processing System) rather than correlator. And the delay value of observed data has the errors of several tens nanoseconds than normal case at the analysis of correlation result. In addition, we found that the phase of correlation results is not connected as the unit of FFT-segment because the initial fringe phase at the fringe rotation module is not correctly determined. In this paper, in order to solve these problems, the original direction of 90 degree phase jump is reversely modified when the bit-shift occurred at the delay tracking. And the initial fringe phase at the fringe rotation module is correctly modified by using the initial phase of observed data. In addition, the parameter calculation module was abnormally operated as designed in the fringe rotation. So, the logical program by the VCS is modified so as to calculate the parameters correctly. Through the experiments of correlation processing over the above problems, the modified proposal algorithm is adequately corrected to the data analysis results, so that the experimental results make it clear for us to operate the developed VCS hardware correlator normally.

Development of Integrated fringe Analysis System: For Severe Noise-ridden Interferometric Image Analysis (통합 프린지 해석 시스템 개발 : 심한 잡음을 포함하는 간섭 이미지 해석용)

  • Kang, Min-Gu;Joo, Won-Jong;Cha, Dong-Jin;Kang, Bo-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.11
    • /
    • pp.1534-1541
    • /
    • 2003
  • A new window-based, user-friendly fringe analysis system is developed, especially for analyzing noisy interferograms. The system integrates three major techniques, that is fringe tracking, Phase shifting, and Fourier transform, into a single shell by employing a unified procedure. Since the system is made in a modular fashion and all processing modules can be shared for any technique, a user can select necessary modules and easily edit the applying order of them based on the user's analysis strategy, which should be changed depending on the noise level of the image. The system provides a high-level GUI and a variety of image handling tools and therefore users can easily access the system and produce the optimal results without giving up in the middle of a process even for severely noise-contaminated interferometric images.

Abnormal Behavior in Color Tracking in the Fringe-Field Switching (FFS) Liquid Crystal Display

  • Jung, Jun-Ho;Ha, Kyung-Su;Chae, Mi-Na;Cho, In-Young;Kim, Woo-Il;Kim, Dae-Hyun;Kim, Sung-Min;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.616-619
    • /
    • 2009
  • Color tracking behavior of in the fringe-field switching (FFS) mode using a liquid crystal with positive dielectric anisotropy has been studied. In the in-plane switching and vertical alignment devices, color chromaticity at normal direction changes from bluish to yellowish white linearly with increasing grey levels from dark to white state. Interestingly, abnormal behavior in color tracking is observed in FFS devices using a liquid crystal with positive dielectric anisotropy, that is, it changes from bluish to yellowish up to a certain middle grey level but turns over to bluish white with further increasing from a grey level to a fully white state. In this paper, we analyze this abnormal effect from the calculated and experimental results.

  • PDF

Measurement of 3D Flow inside Micro-tube Using Digital Holographic PTV Technique (디지털 Holographic PTV기법을 이용한 미세튜브 내부 3차원 유동장 측정)

  • Kim, Seok;Kim, Ju-Hee;Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.177-178
    • /
    • 2006
  • Digital holographic particle tracking velocimetry (HPTV) is developed by single high-speed camera and single continuous laser with long coherent length. This system can directly capture 4000 hologram fringe images for 1 second through a camera computer memory. The 3D particle location is made of the reconstruction by using a computer hologram algorithm. This system can successfully be applied to instantaneous 3D velocity measurement in the water flow inside a micro-tube. The average of 100 instantaneous velocity vectors is obtained by reconstruction and tracking with the time of evolution of recorded fringes images. In the near future, we will apply this technique to measure 3D flow information inside various micro structures.

  • PDF

A Study on the analysis of in-cylinder flow fields using PTV (PTV를 이용한 실린더내 유동장 해석에 관한 연구)

  • Jeong, Hwan-Su;Choi, Su-Jin;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.692-697
    • /
    • 2000
  • In Particle Tracking Velocimetry, the analysis of double-exposed photographic plate can be carried out either by means of Young's fringe analysis or by a digital image processing technique. In this study, we used digital image processing to two images in one frame far analyzing in-cylinder flow fields, and compared PTV with PSV(Particle Streak Velocimetry). Additionally, this technique was verified by two different calibration method. One is interpolation by invert distance, the other is interpolation by area ratio. Finally, the results between two interpolation methods were similar in whole flow fields.

  • PDF

Analysis of Density Distribution for Butane Using Three-dimentional and Real-time Digital Speckle Tomography (3차원 실시간 디지털 스페클 토모그래피를 이용한 부탄 밀도 분포 분석)

  • Go, Han-Seo;Park, Gwang-Hui;Kim, Yong-Jae
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1789-1794
    • /
    • 2003
  • Transient and asymmetric density distributions have been investigated by digital speckle tomography. Multiple CCD images captured movements of speckles in three angles of view simultaneously because the flows were asymmetric and transient. The speckle movements between no flow and downward butane flow from a circular half opening have been calculated by a cross-correlation tracking method so that those distances can be tranferred to deflection angles of laser rays for density gradients. The three-dimensional density fields have been reconstructed from the fringe shift by a real-time multiplicative algebraic reconstruction technique (MART).

  • PDF

Beam line design and beam transport calculation for the μSR facility at RAON

  • Pak, Kihong;Park, Junesic;Jeong, Jae Young;Kim, Jae Chang;Kim, Kyungmin;Kim, Yong Hyun;Son, Jaebum;Lee, Ju Hahn;Lee, Wonjun;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3344-3351
    • /
    • 2021
  • The Rare Isotope Science Project was launched in 2011 in Korea toward constructing the Rare isotope Accelerator complex for ON line experiments (RAON). RAON will house several experimental systems, including the Muon Spin Rotation/Relaxation/Resonance (μSR) facility in High Energy Experimental Building B. This facility will use 600-MeV protons with a maximum current of 660 pμA and beam power of 400 kW. The key μSR features will facilitate projects related to condensed-matter and nuclear physics. Typical experiments require a few million surface muons fully spin-polarized opposite to their momentum for application to small samples. Here, we describe the design of a muon transport beam line for delivering the requisite muon numbers and the electromagnetic-component specifications in the μSR facility. We determine the beam-line configuration via beam-optics calculations and the transmission efficiency via single-particle tracking simulations. The electromagnet properties, including fringe field effects, are applied for each component in the calculations. The designed surface-muon beamline is 17.3 m long, consisting of 2 solenoids, 2 dipoles affording 70° deflection, 9 quadrupoles, and a Wien filter to eliminate contaminant positrons. The average incident-muon flux and spin rotation angle are estimated as 5.2 × 106 μ+/s and 45°, respectively.

DEVELOPMENT AND PERFORMANCE EVALUATION OF SOFTWARE SIMULATOR FOR APPROVING OF VLBI CORRELATION SUBSYSTEM (VLBI상관서브시스템의 검증을 위한 소프트웨어 시뮬레이터의 개발 및 성능시험)

  • Oh, Se-Jin;Roh, Duk-Gyoo;Yeom, Jae-Hwan;Chung, Hyun-Soo;Lee, Chang-Hoon;Kim, Hyo-Ryoung;Kim, Kwang-Dong;Kang, Yong-Woo;Park, Sun-Yeop
    • Publications of The Korean Astronomical Society
    • /
    • v.23 no.2
    • /
    • pp.73-90
    • /
    • 2008
  • A software simulator is developed for verifying the VLBI Correlation Subsystem (VCS) trial product hardware. This software simulator includes the delay tracking, fringe rotation, bit-jump, FFT analysis, re-quantization, and auto/cross-correlation functions so as to confirm the function of the VCS trial product hardware. To verify the effectiveness of the developed software simulator, we carried out experiments using the simulation data which is a mixed signal with white noise and tone signal generated by software. We confirmed that the performance of this software simulator is similar as that of the hardware system. In case of spectral analysis and re-quantization experiment, a serious problem of the VCS hardware, which is not enough for expressing the data stream of FFT results specified in VCS hardware specification, was found by this software simulator. Through the experiments, the performance of software simulator was verified to be efficient. In future, we will improve and modify the function of software simulator to be used as a software correlator of Korea-Japan Joint VLBI Correlator (KJJVC).

Performance Evaluation of VLBI Correlation Subsystem Main Product (VLBI 상관 서브시스템 본제품의 제작현장 성능시험)

  • Oh, Se-Jin;Roh, Duk-Gyoo;Yeom, Jae-Hwan;Oyama, Tomoaki;Park, Sun-Youp;Kang, Yong-Woo;Kawaguchi, Noriyuki;Kobayashi, Hideyuki;Kawakami, Kazuyuki
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.4
    • /
    • pp.322-332
    • /
    • 2011
  • In this paper, we introduce the 1st performance evaluation of VLBI Correlation Subsystem (VCS) main product, which is core system of Korea-Japan Joint VLBI Correlator (KJJVC). The main goal of the 1st performance evaluation of VCS main product is that the perfection of overall system will be enhanced after checking the unsolved part by performing the experiments towards various test items at the manufacturer before installation of field. The functional test was performed by including the overflow problem occurred in the FFT re-quantization module due to the insufficient of effective bit at the VCS trial product in this performance test of VCS main product. Through the performance test for VCS main product in the factory, the problem such as FFT re-quantization discovered at performance test of VCS trial product in 2008 was clearly solved and the important functions such as delay tracking, daly compensation, and frequency bining were added in this VCS main product. We also confirmed that the predicted correlation results (fringe) was obtained in the correlation test by using real astronomical observed data(wideband/narrow band).