• Title/Summary/Keyword: Frictional test

Search Result 419, Processing Time 0.023 seconds

Changes in frictional resistance between stainless steel bracket and various orthodontic wires according to a change in moment (모멘트 변화에 따른 브라켓과 교정용 선재 사이의 마찰력 변화)

  • Jeong, Hye-Jin;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.137-149
    • /
    • 2007
  • Objective: The purpose of this study was to compare changes in frictional resistance between the bracket and wire under dry and wet conditions according to a change in moment. Methods: A stainless steel bracket of $0.022"{\times}0.028"$ slot, and $0.019"{\times}0.025"$ stainless steel, beta-titanium, and nickel-titanium wires were used. A 10 mm length lever was attached to the test (sliding) brackets to generate a moment. The experimental model was designed to allow tipping until contacts were established between the wire and the mesiodistal edges of the bracket slot. The moment was generated by suspending a 100 g or 200 g weight on the end of the lever. The moments applied were $1000g{\cdot}mm\;(100g{\times}10mm)\;and\;2000g{\cdot}mm\;(200g{\times}10mm)$. The test brackets were ligated with elastomeric ligature for a constant ligation force and the fixed brackets were ligated with stainless steel ligature. Brackets were moved along the wire by means of an universal testing machine, and maximum frictional resistances were recorded. Results: Stainless steel wire showed least frictional resistance and there was no significant difference between beta-titanium and nickel-titanium except at $2000g{\cdot}mm$ moment in wet conditions. Frictional resistance of all wires increased as the moment increased from $1000g{\cdot}mm\;to\;2000g{\cdot}mm$. Under wet conditions, the frictional resistance of stainless steel wires increased in both $1000g{\cdot}mm\;and\;2000g{\cdot}mm$ moment conditions, but frictional resistance of nickel-titanium and beta-titanium increased only in $2000g{\cdot}mm$ conditions. Conclusion: These results indicated that various conditions influence on frictional resistance. Therefore, laboratory studies of frictional resistance should simulate clinical situation.

A Basic Study on Functional Friction Surface of Artificial Joints (내마모성이 향상된 기능성 표면구조를 갖는 인공관절에 관한 기초적인 연구)

  • ;T. Yuhta
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.519-526
    • /
    • 2001
  • At present. about 0.3 million and more THRs (Total Hip Replacement) in a rear are being done worldwide. The increase in mechanical failure with the increase in THR, required more revisions. Revisions compensate mainly the wear of the artificial joint frictional surface and the loosening of the cup and stem. According to recent researches, loosening is mainly due to wear debris UHMWPE (Ultra High Molecular Weight Polyethylene) from frictional surfaces . To overcome the wear problems associated with artificial joint materials , new surface structures with regular Patterns were designed and fabricated The lubrication Properties were examined to evaluate the wear of the frictional surfaces. The surface structure manifested a Pattern of "dents" with a 0.2-1.0 mm of diameter and 0.6-2.0 mm of Pitch. From the friction test of the SUS316L vs UHMWPE using the frictional tester, we found that the lubrication Performance was improved due to of drastically reduced amount of abrasion. There were optimum sizes for the diameter and the pitch of the Pattern. The results demonstrated that the lubrication properties could be improved by Patterning of the frictional surfaces. The surface Patterning was effective in preventing wear of the frictional surfaces, and the life of an artificial joint could be extended with such Patterning.

  • PDF

The study of frictional damper with various control algorithms

  • Mirtaheri, Masoud;Samani, Hamid Rahmani;Zandi, Amir Peyman
    • Earthquakes and Structures
    • /
    • v.12 no.5
    • /
    • pp.479-487
    • /
    • 2017
  • Frictional dampers are used in structural engineering as means of passive control. Meanwhile, frictional damper shave a disadvantage compared to viscous rivals since the slippage force must be exceeded to activate the device, and cannot be ideal full range of possible events. The concept of semi-active control is utilized to overcome this shortcoming. In this paper, a new semi-active frictional damper called Smart Adjustable Frictional (SAF) damper is introduced. SAF damper consists of hydraulic, electronic units and sensors which are all linked with an active control discipline. SAF acts as a smart damper which can adapt its slippage threshold during a dynamic excitation by measuring and controlling the structural response. The novelty of this damper is, while it controls the response of the structure in real time with acceptable time delay. The paper also reports on the results of a series of experiments which have been performed on SAF dampers to obtain their prescribed hysteretic behavior for various control algorithms. The results show that SAF can produce the desired slippage load of various algorithms in real time. Numerical models incorporating control simulations are also made to obtain the hysteretic response of the system which agrees closely with test results.

A Study on Relationship Between Basic Frictional Angle and Mineral Composition for Granite Sample (화강암 시험편의 광물조성과 기본마찰각의 상관성에 관한 연구)

  • Lee, Bong-Hyun;Lee, Seung-Joong;Choi, Sung-Oong
    • Tunnel and Underground Space
    • /
    • v.24 no.1
    • /
    • pp.32-45
    • /
    • 2014
  • Basic frictional angle is a parameter that can estimate shear strength of rock, and is a design parameter employed in slope stability analysis. Basic frictional angle generates various results in accordance with mineral composition, apart from rock surface roughness itself. This paper describes the correlation of basic frictional angle and mineral composition. The basic frictional angle is measured with the aid of the modified tilt testing apparatus, and its reliability is improved by the statistical method. Also, mineral composition is identified through the photographic analysis on rock specimen, and verified through the thin section analysis.

Experimental Study on Frictional Characteristics of Sheet Metal Forming (박판성형 마찰특성의 실험적 연구)

  • 금영탁;이봉현;차지혜
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.54-57
    • /
    • 2002
  • In order to find the effect of lubricant viscosity, sheet surface roughness, tool geometry, and forming speed on the frictional characteristics in sheet metal forming, a sheet metal friction tester was designed and manufactured and friction tests of various sheets were performed. Friction test results showed that as the lubricant viscosity becomes lower, the friction coefficient is higher. When surface roughness is extreme1y low or high, the friction coefficient is high. As punch comer radius and punch speed are bigger, the value of friction coefficient is smaller. The sensitivity of friction coefficient is mainly governed by lubricant viscosity and sheet surface roughness.

  • PDF

An Experimental Study on the Power Transmission Efficiency and Frictional Noise of $MoS_2$-Bonded-Film Coated Reduction Gears (접착형 $MoS_2$고체윤활피막이 코팅된 감속기의 동력전달효율과 소음 특성에 관한 실험적 고찰)

  • 윤의성;공호성;한홍구;오재응
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.107-114
    • /
    • 1996
  • MoS$_{2}$ bonded film was applied to reduction gears, and its lubricating properties were experimentally evaluated in terms of the power transmission efficiency and the frictional noise with a dynamo-typed gear test rig. Tests were performed in both oil lubrication and dry condition where the rotating velocity and loading torque were varied. In dry condition, MoS$_{2}$ bonded films effected the power transmission efficiency to increase about 5%, and the frictional noise level to decrease about 6 dB under the test operating conditions. It well proved that MoS$_{2}$ bonded films were a very effective solid lubricant for reduction gears. In oil lubricating conditions, the frictional properties of the coated gears were mainly governed by the lubricating oil, and lubricating effects of MoS2 bonded films were not evident. The result suggested that lubricating effect of MoS$_{2}$ bonded films would be limited to prevent a damage of reduction gears in the initial run when they were used in oil lubrication conditions.

Sensitivity of Dimensional Changes to Interfacial Friction over the Definite Range of Friction Factor in Ring Compression Test (링 압축시험에서 마찰인자 구간별 치수 변화의 민감도)

  • Lim, J.Y.;Noh, J.H.;Hwang, B.B.
    • Transactions of Materials Processing
    • /
    • v.19 no.8
    • /
    • pp.494-501
    • /
    • 2010
  • The main objective of this study is to examine the sensitivity of calibration curves of FEA of ring compression test to frictional shear factor. Ring compression test has been investigated by measuring dimensional changes at different positions of ring specimen and they include the changes in internal diameter at the middle and top section of the specimen, outer diameter at the middle and top section, surface expansion at the top surface, respectively. Initial ring geometries employed in analysis maintain a fixed ratio of 6 : 3 : 2, i.e. outer diameter : inner diameter : thickness of the ring specimen, which is generally known as 'standard' specimen. A rigid plastic material for different work-hardening characteristics has been modeled for simulations using rigid-plastic finite element code. Analyses have been performed within a definite range of friction as well as over whole range of friction to show different sensitivities to the interfacial friction for different ranges of friction. The results of investigation in this study have been summarized in terms of a dimensionless gradient. It has been known from the results that the dimensional changes at different positions of ring specimen show different linearity and sensitivity to the frictional condition on the contact surface.

A New Experimental Technique for Calibration of Frictional Force in Atomic Force Microscopy (원자 현미경에서 마찰력 측정을 위한 새로운 실험 기법)

  • Choi, Duk-Hyun;Hwang, Woon-Bong;Yoon, Eui-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1906-1913
    • /
    • 2004
  • A new method has been proposed for the calibration of frictional forces in atomic force microscopy. Angle conversion factor is defined using the relationship between torsional angle and frictional signal. Once the factor is obtained from a cantilever, it can be applied to other cantilevers without additional experiments. Moment balance equations on the flat surface and top edge of a commercial step grating are used to obtain angle conversion factor. Proposed method is verified through another step grating test and frictional behavior of Mica.

A New Experimental Technique for Calibration of Frictional Force in Atomic Force Microscopy (원자 현미경에서 마찰력 측정을 위한 새로운 실험 기법)

  • Choi, Duk-Hyun;Hwang, Woon-Bong;Yoon, Eui-Sung;Kim, Joon-Won;Kim, Dong-Sik
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.846-851
    • /
    • 2004
  • A new method has been proposed for the calibration of frictional forces in atomic force microscopy. Angle conversion factor is defined using the relationship between torsional angle and frictional signal. Once the factor is obtained from a cantilever, it can be applied to other cantilevers without additional experiments. Moment balance equations on the flat surface and top edge of a commercial step grating are used to obtain angle conversion factor. Proposed method is verified through another step grating test and frictional behavior of Mica.

  • PDF

A Study on Pressure Drop Characteristics of Refrigerant in Heat Exchanger for Automobile (자동차용 열교환기 냉매의 압력 강하 특성에 관한 연구)

  • 임태우;박종운
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.119-125
    • /
    • 2003
  • An experiment study on pressure drop was carried out for both an adiabatic and a diabatic two-phase flow with pure refrigerants R134a and Rl23 and their mixtures as test fluids in a uniformly heated horizontal tube. The frictional pressure drop during flow boiling is predicted by using two models; the homogeneous model that assumes equal phase velocity and the separate flow model that allows a slip velocity between two phases. The measured frictional pressure drop was compared to a few available correlations. Homogeneous model considerally underpredicted the present data for mixture as well as pure component in the entire mass velocity ranges employed in the present study, while Friedel correlation was found to satisfactorily correlate the frictional pressure drop data as compared to other correlation.