• 제목/요약/키워드: Frequency-Dependent Evaluation

검색결과 99건 처리시간 0.024초

동시 3축 가진에 의한 자동차 의자류의 승차감 평가 (Ride Quality Assessment of Automative Seats by Simultaneous 3-Axis Excitation)

  • 정완섭;우춘규;박세진;김수현
    • 소음진동
    • /
    • 제7권1호
    • /
    • pp.143-152
    • /
    • 1997
  • This paper introduces experimental results of the ride qulaity characteristics of automotive seats fixed on the vibration table that is noving simultaneously to the three-axis in a similar way to the real running condition. Vibration experiment was carried out for five different automotive seats and four Korean individuals. The assessment of the ride quality characteristics for each seat and indiviual was made not only from the analysis of vibration measurements but also from the evaluation of weighied vibration signals, which were obtained using the frequency weighting function and the multiplication factor dependent on the position and axis of vibration exposure to wehole-body. The usefulness of those assessment results in analysis of the ride quality of seats is discussed and their limitation is also pointed out in this paper.

  • PDF

FFT를 이용한 연속초음파 도플러 장치에 관한 연구 (A study on the development of CW(Continuous-Wave) Doppler System using FFT)

  • 이대형;강충신;박세현;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.709-712
    • /
    • 1988
  • Ultrasonic Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. CW(Continuous-Wave) Doppler System uses quadrature detection and phase rotation method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time-domain, had been fabricated. But time-domain analyzing such as audio evaluation and zero- crossing detection for instantaneous and mean frequnecy measurement do not provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency-domain technique to improve system performance. In this paper, we describe a unit which is composed of CW Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of Blood signal.

  • PDF

A Study on Off-Gas Treatment of an Air Stripping Tower Using a Plasma Reactor

  • Lim, Gye-Gyu;Yoo, Ho-Sik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제9권E호
    • /
    • pp.382-389
    • /
    • 1993
  • An evaluation of a plasma reactor was conducted to investigate its potential as a feasible and economical off-gas control technology for an air stripping tower (AST). The plasma reactor was powered by an alternating current with frequencies up to 1000Hz. The study showed that over 90% conversion of gas-phase trichloroethylene (TCE) can be achieved. An optimum frequency for the laternating current existed for maximum power input. The optimum frequency was dependent on the reactor geometry and the primary voltage applied. for a fixed geometry, a plasma reactor has a limited capacity for flow rate. Even though it is a feasible process to control off-gases, further investigations should be conducted to develop a more economic process.

  • PDF

파일럿 패턴에 따른 OFDM 시스템의 성능 분석 (Performance Evaluation of OFDM Systems Dependent upon Pilot Patterns)

  • 최승국
    • 한국정보통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.273-279
    • /
    • 2007
  • 주파수 선택적 도플러 시변 채널 환경 하에서 파일럿 패턴에 따라 결정되는 ORDM 시스템의 비트 오류율 성능을 분석한다. 시변 채널 추정 에러로 인하여 비트 오류율 성능 열화가 발생된다. 이러한 성능 열화를 충분히 작게 하기 위하여 파일럿 심볼들은 주파수 축 상에서 5 부반송파 간격 이하로, 시간 축 상에서 6 OFDM 블록 간격 이하로 배치되어야 함을 알 수 있다.

Developed empirical model for simulation of time-varying frequency in earthquake ground motion

  • Yu, Ruifang;Yuan, Meiqiao;Yu, Yanxiang
    • Earthquakes and Structures
    • /
    • 제8권6호
    • /
    • pp.1463-1480
    • /
    • 2015
  • This research aims to develop an empirical model for simulation of time-varying frequency in earthquake ground motion so as to be used easily in engineering applications. Briefly, 10545 recordings of the Next Generation Attenuation (NGA) global database of accelerograms from shallow crustal earthquakes are selected and binned by magnitude, distance and site condition. Then the wavelet spectrum of each acceleration record is calculated by using one-dimensional continuous wavelet transform, and the frequencies corresponding to the maximum values of the wavelet spectrum at a series of sampling time, named predominant frequencies, are extracted to analyze the variation of frequency content of seismic ground motions in time. And the time-variation of the predominant frequencies of 178 magnitude-distance-site bins for different directions are obtained by calculating the mean square root of predominant frequencies within a bin. The exponential trigonometric function is then use to fit the data, which describes the predominant frequency of ground-motion as a function of time with model parameters given in tables for different magnitude, distance, site conditions and direction. Finally, a practical frequency-dependent amplitude envelope function is developed based on the time-varying frequency derived in this paper, which has clear statistical parameters and can emphasize the effect of low-frequency components on later seismic action. The results illustrate that the time-varying predominant frequency can preferably reflect the non-stationarity of the frequency content in earthquake ground motions and that empirical models given in this paper facilitates the simulation of ground motions.

크리프 기공의 초음파 비파괴평가에 관한 연구 (Ultrasonic Nondestructive Evaluation of Creep-Induced Cavities)

  • 장영수;정현조
    • 비파괴검사학회지
    • /
    • 제19권2호
    • /
    • pp.110-117
    • /
    • 1999
  • 크리프 손상을 단계적으로 받은 순수 구리 시편에 대하여 손상 진전에 따른 기공의 미시구조 변화를 관찰하고 초음파 속도와 주파수 의존 진폭 스펙트럼 및 감쇠를 측정하였다. 손상 진전에 따른 입계기공의 비등방적 성장으로 인하여 하중축에 대하여 세 방향으로 측정한 속도는 이방성 거동을 보였다. 최대 2%의 기공에 대하여 종파와 횡파는 각각 11%와 4%의 속도 감소를 보였으며, 기공량의 증가와 함께 비선형적인 감소 경향을 보였다. 진폭 스펙트럼은 기공량이 증가함에 따라 고주파수 성분이 감소하고 중심 주파수가 저주파수로 이동하였으며, 감쇠는 사용 주파수 범위에서 거의 선형적인 거동을 보였다. 기공량의 정량적 비파괴평가 파라미터로서 정규화 속도, 진폭 스펙트럼의 중심 주파수, 감쇠 기울기를 선정하였으며 기공량과의 상관관계를 제시하였다.

  • PDF

고주파 부분방전 측정에 의한 초고압 접속함 신뢰성 평가 기술 (A Evaluation Technique for Reliability of Extra-High Voltage Cable Accessories using High Frequency Partial Discharge Measurement)

  • 신두성;이창영;김충식;전승익;김동욱;박완기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권3호
    • /
    • pp.186-195
    • /
    • 2000
  • In this paper, partial discharge (PD) measurement was performed to evaluate the quality of the cable joint and termination constructions. The resistive coupling technique for PD detection using resistivity of semiconducting layer of the cable in the accessories, such as joints and terminations. With high frequency PD (HEPD) measurement, an excellent sensitivity below 20pC could be achieved under unshielded condition. The localization of the defects in the accessories could be identified. During heating cycle, PDs were monitored and analyzed. At that time, the PDs were dependent on the temperature of the heating cycle and showed cyclic behaviors, which were attributed to local delamination of the interfaces, between epoxy unit and stress relief cone(SRC) and between SRC and cable, due to the difference of thermal expansion. As a conclusion, HFPD measurement technique was proven to be an effective diagnostic method for qualification of extra high voltage (EHV) cable accessories. With this technique, the optimal design of the components of the accessories could be verified not only in an early stage but also under operating condition. This technique would result in the improvement of the reliability of the EHV cable accessories.

  • PDF

FPGA를 이용한 LUTS 진단 시스템 구현 및 평가 (Implementation and Evaluation of the LUTS Diagnosis System Using FPGA)

  • 정도운;정완영;전계록
    • 융합신호처리학회논문지
    • /
    • 제8권1호
    • /
    • pp.6-14
    • /
    • 2007
  • 요역동학검사는 하부요로계의 이상증상을 진단하기위하여 수행된다. 일반적으로 임상에서 행해지는 요역동학검사에서는 침습적인 방법으로 방광을 채운 후 배뇨하는 절차를 거친다. 하지만 이러한 방법은 카테터를 삽입해야하므로 환자에게 고통을 수반하게 한다. 본 연구에서는 비침습적이고 보다 편리한 방법으로 하부요로계의 기능을 평가할 수 있는 시스템을 구현하고자 하였다. 비침습적인 방법으로 하부요로증상(lower urinary tract symptoms, LUTS)의 진단을 위하여 배뇨시 요속, 요류음, 비침습적 방광내압을 측정할 수 있는 시스템을 구현하였다. 구현된 시스템은 센서부, 신호처리부, FPGA를 이용한 시스템 제어부 그리고 PC모니터링 프로그램으로 구성하였다. 그리고 구현된 계측시스템의 평가를 위하여 FPGA 시스템 제이부의 시뮬레이션을 수행하였고 인체의 하부요로계를 모식화한 실험장치를 구현하였다. 실험장치를 이용한 측정부의 평가결과 요속측정부의 평균에러율이 1.08%, 계수변화율이 1.48로 평가되었다. 그리고 비침습적 방광내압부는 평균에러율이 2.41%, 계수변화율이 2.81로 나타났다. 요류음신호의 시간영역과 주파수영역에서의 분석위해 평균실효치전력(average RMS power)과 주파수영역에서의 중심주파수(median frequency, MF)를 분석하였으며, 그 결과 $60{\sim}160Hz$의 중심주파수대에서 폐색을 가장 잘 반영하였다.

  • PDF

Speaker-Dependent Emotion Recognition For Audio Document Indexing

  • Hung LE Xuan;QUENOT Georges;CASTELLI Eric
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.92-96
    • /
    • 2004
  • The researches of the emotions are currently great interest in speech processing as well as in human-machine interaction domain. In the recent years, more and more of researches relating to emotion synthesis or emotion recognition are developed for the different purposes. Each approach uses its methods and its various parameters measured on the speech signal. In this paper, we proposed using a short-time parameter: MFCC coefficients (Mel­Frequency Cepstrum Coefficients) and a simple but efficient classifying method: Vector Quantification (VQ) for speaker-dependent emotion recognition. Many other features: energy, pitch, zero crossing, phonetic rate, LPC... and their derivatives are also tested and combined with MFCC coefficients in order to find the best combination. The other models: GMM and HMM (Discrete and Continuous Hidden Markov Model) are studied as well in the hope that the usage of continuous distribution and the temporal behaviour of this set of features will improve the quality of emotion recognition. The maximum accuracy recognizing five different emotions exceeds $88\%$ by using only MFCC coefficients with VQ model. This is a simple but efficient approach, the result is even much better than those obtained with the same database in human evaluation by listening and judging without returning permission nor comparison between sentences [8]; And this result is positively comparable with the other approaches.

  • PDF

전자근관장 측정기의 정확도에 관한 연구 (IN VIVO EVALUATION OF ACCURACY OF TWO ELECTRONIC APEX LOCATORS)

  • 김회정;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.289-299
    • /
    • 1996
  • It is necessary to measure the length of a root canal in order to attain a satisfactory prognosis after root canal therapy. There are several methods for determining root canal length, such as tactile sensation by the dental practitioner, the utilization of x-ray film, and electronic root canal measurement. Among these, the electrical measurement methods, in which the impedence between the oral mucous membrane and periodontal membrane is determined, have advantages of simplicity and accuracy. During root canal treatment, the root canal contains a solution of high electrical conductivity such as pus, blood, sodium hypochlorite and so on. Recently a new electronic root canal measurement device of frequency-dependent type has been developed, which is capable of measuring the length of root canal under moist conditions. Endex and Root ZX, which are frequency-dependent type, were evaluated for accuracy of measuring root canal length in vivo by stereomicroscope. The result were as follows ; 1. 82.5% of Endex and 87.5% of Root ZX measured in the range of ${\pm}0.5$ mm from the apical foramen and both showed 57.5 % in the range of 0.1 mm to 0.5 mm. 2. Endex showed significantly higher accuracy in vital teeth than nonvital teeth(p<0.05). But in case of Root ZX, there was no significant difference between vital and nonvital teeth. 3. As a result of this study, there was no significant difference in accuracy between Endex and Root ZX, and both devices showed file passes the apical foramen in more than half of the cases, and it is thought that this must be considered clinically.

  • PDF