• Title/Summary/Keyword: Frequency scanning

Search Result 524, Processing Time 0.025 seconds

Auto-focus of Optical Scanning Holographic Microscopy Using Partial Region Analysis (광 스캐닝 홀로그램 현미경에서 부분 영역 해석을 통한 자동 초점)

  • Kim, You-Seok;Kim, Tae-Geun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.10-15
    • /
    • 2011
  • In this paper, we propose an auto-focusing algorithm which extracts a depth parameter by analyzing a selected part of a hologram, and we use experimental results to show that the algorithm is practical. First, we record a complex hologram using Optical Scanning Holography. Next we select some part of hologram and extract depth information through Gaussian low pass filtering, synthesizing a real-only hologram, power fringe-adjusted filtering and inverting to a new frequency axis. Finally, we reconstruct the hologram automatically using the extracted depth location.

Measurement Data Comparison of Fast SAR Measurement System by Probe Arrays with Robot Scanning SAR Measurement System

  • Kim, Jun Hee;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.336-341
    • /
    • 2014
  • Dosimetry of radiating electromagnetic wave from mobile devices to human body has been evaluated by measuring Specific Absorption Rate (SAR). Usual SAR measurement system scans the volume by robot arm to evaluate RF power absorption to human body from wireless devices. It is possible to fast estimate the volume SAR by software deleting robot moving time with the 2D surface SAR data acquired by arrayed probes. This paper shows the principle of fast SAR measurement and the measured data comparison between the fast SAR system and the robot scanning system. Data of the fast SAR is well corresponding with data of robot scanning SAR within ${\pm}3$ dB, and its dynamic range covers from 10 mW/kg to 30 W/kg with 4.8 mm probe diameter.

Development of confocal scanning microscopy using acousto-optica1 deflector

  • J.W. Seo;D.K. Kang;H.G. Yun;Kim, K.H.;D.G. Gweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.161.6-161
    • /
    • 2001
  • Confocal scanning microscopy (CSM) has an important role as the three-dimensional profiler. An image distribution can be reconstructed by a correlation analysis of spots with the bandwidth of radio frequency. But it is a serious problem for the high performance to align the optical components. Especially, the parasitic motion of focus on the detector gives rise to the fatal distortion of an image profile named the extinction effect while using acousto-optical(AO) deflector. An image profile can be regenerated in CSM with many advantages of non-contact, high speed and high resolution comparatively. In addition to the axial response of the primary focus, the lateral movement of it gives a necessity of the unitary lens to the scanning system. While using the beam deflector, the pupil of beam may be fixed at the nominal position. Furthermore, the use of a deflector may result in ...

  • PDF

The feature of scanning path algorithm shown at natural visual search activities of space user (공간사용자의 본능적 시선탐색활동에 나타난 주사경로 알고리즘 특성)

  • Kim, Jong-Ha;Kim, Ju-Yeon
    • Science of Emotion and Sensibility
    • /
    • v.17 no.2
    • /
    • pp.111-122
    • /
    • 2014
  • This study has analyzed the scanning path algorithm shown at the process of exploring spatial information through an observation experiment with the object of lobby in subway station. In the estimation of observation time by section, the frequency of scanning type was found to increase as the observation time got longer, which makes it possible that the longer the observation lasts the more the observation interruptions occur. In addition, the observation slipped out of the range of imaging when any fatigue was caused from the observation or the more active exploration took place. Furthermore, when the trend line was employed for the examination of the changes to the scanning type by time section, "concentration" "diagonal or vertical" showed a sharp and a gentle increases along with the increase of time section respectively, while "circulation. combination, horizontal" showed a reduction. The observation data of the subjects observing a space include various visual information. The analysis of the scanning type found at "attention concentration" enabled to draw this significant conclusion. The features of increase and decrease of scanning types can be a fundamental data for understanding the scanning tendency by time.

Thermal study of a scanning beam in granular flow target

  • Ping Lin;Yuanshuai Qin;Changwei Hao;Yuan Tian ;Jiangfeng Wan ;Huan Jia ;Lei Yang ;Wenshan Duan ;Han-Jie Cai ;Sheng Zhang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4310-4321
    • /
    • 2022
  • The concept of dense granular-flow target (DGT) for the China Initiative Accelerator Driven Subcritical system (CiADS) is an attractive choice for high heat removal ability, low chemical toxicity, and radiotoxicity. A wobbling hollow beam is proposed to enhance the homogeneity of temperature rise of flowing particles in beam-target coupling zone. In this paper, the design procedure of target and beam parameters was discussed firstly. Then we simulated the heat deposition and transfer of the scanning beam in DGT to study the effect of beam parameters. The results show the flux density of proton beam plays a crucial role in the distribution of temperature rise while the contributions from scanning frequency heat transfer are also obvious. Moreover, heat transfer in transversal directions is insignificant, resulting in a low heat flux towards the sidewalls of DGT. This work not only contributes to the design of DGT, but also beneficial for understanding the beam-target coupling in porous materials.

Non-contact type AFM using frequency separation scheme (주파수응답 분리방법을 이용한 비접촉식 AFM)

  • 이성규;염우섭;박기환;송기봉;김준호;김은경;박강호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.375-378
    • /
    • 2002
  • In this paper, the frequency response separation scheme is proposed for high scanning speed and simple structure of non-contact type of AFM. A self-sensing cantilever is attached on the actuator for detect the atomic force between tip and the media surface. VCM or PZT are used for actuator. This paper presents the method to simplify the actuator structure and the performance of each actuator for non-contact type AFM. Based on the frequency response separation scheme, the only one actuator plays roles 1311owing low frequency surface and modulating self-sensing cantilever tip in contrast with convention non-contact type AFM. 10 ${\mu}{\textrm}{m}$ standard grid sample imaged to verify proposed scheme. This result shows the possibility simplifying the actuator structure and reducing cost of non-contact type AFM.

  • PDF

Frequency-Distance Responses in SECM-EQCM: A Novel Method for Calibration of the Tip-Sample Distance$\S$

  • 신명선;전일철
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.11
    • /
    • pp.1227-1232
    • /
    • 1998
  • The frequency response on the tip-sample distance in scanning electrochemical microscopy (SECM) that is combined with an electrochemical quartz crystal microbalance (EQCM) is described. The oscillation frequency of the EQCM increases rapidly when the SECM tip is very close to the substrate electrode surface. This frequency increase is reproducible regardless of the current feedback in SECM, which is attributed to the stress caused by the tip pressing the quartz crystal. It is useful to calibrate the tip-sample distance with respect to the frequency change when a combined system of SECM and EQCM (SECM-EQCM) is used. This method could be applied to several cases such as rigid metal electrode and non-conducting or partially conducting polymer coating prepared on the quartz crystal regardless of the feedback current.

Evaluation of the Thermal Degradation in Co-based Superalloy using High frequency Transducer of Scanning Acoustic Microscope (초음파현미경의 고주파 초음파 탐촉자를 이용한 코발트기 초내열합금강의 열화평가)

  • Park, Ik-Keun;Cho, Dong-Su;Kim, Yong-Kwon;Lim, Jae-Seang;Kim, Chung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.518-524
    • /
    • 2004
  • The feasibility of Y(z) curve method of scanning acoustic microscope using high frequency transducer was experimentally studied for assessment of the thermal degradation in Co-based superalloy. Thermal degradation was performed to simulate the microstructural changes in Co-based superalloy arising from long term exposure at high temperature. Longitudinal wave velocity measured by pulse echo method using 10MHz transducer and leaky surface acoustic wave (LSAW) velocity measured by V(z) curve method using 200MHE transducer were measured to investigate the effect on thermal degradation. Ultrasonic velocity decreased as the aging time increased in both ultrasonic waves. Moreover, the low frequency longitudinal wave velocity decreased a little. Otherwise, the high frequency LSAW velocity drastically decreased up to a maximum of 4.7% at the aging time of 4,000hours. A good correlation was found between LSAW and Vickers hardness. Consequently, V(z) curve method of SAM using high frequency transducer could be a potential tool for assessing thermal degradation.