• Title/Summary/Keyword: Frequency response characteristics

Search Result 1,549, Processing Time 0.026 seconds

A Study on the Vibration Characteristics of 3-Dimension Submerged Vehicle in Consideration of Fluid-Structure Interaction (유체력을 고려한 3차원 수중압력선체의 진동특성에 관한 연구)

  • 손충렬;김경수;변효인
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.1
    • /
    • pp.19-25
    • /
    • 2001
  • Unlike structures in the air, the vibration analysis of a submerged or floating structure such as offshore structures or ships is possible only when the fluid-structure interaction is understood, as the whole or part of the structure is in contact with water. This paper introduces two methods to find natural frequency in consideration of fluid-structure interaction, direct coupled vibration analysis and fluid-structure modal coupled vibration analysis. The purpose of this study is to analyze the vibration characteristic of a submerged vehicle to obtain the anti-vibration design data, which could be used in the preliminary design stage. The underwater pressure hull of submerged vehicle is used as the model of this study. The F.E.M. model is meshed by shell and beam elements. Also, considering the inner hull weight, the mass element is distributed in the direction of hull length. Numerical calculations are accomplished by using the commercial B.E.M. code. The characteristics of natural frequency, mode shape and frequency-displacement response are analyzed.

  • PDF

Seismic performance of a fiber-reinforced plastic cable-stayed bridge

  • Hodhod, Osama A.;Khalifa, Magdi A.
    • Structural Engineering and Mechanics
    • /
    • v.5 no.4
    • /
    • pp.399-414
    • /
    • 1997
  • This paper presents an investigation into the seismic response characteristics of a proposed ligh-weight pedestrian cable-stayed bridge made entirely from Glass Fiber Reinforced Plastics(GFRP). The study employs three dimensional finite element models to study and compare the dynamic characteristics and the seismic response of the GFRP bridge to a conventional Steel-Concrete (SC) cable-stayed bridge alternative. The two bridges were subjected to three synthetic earthquakes that differ in the frequency content characteristics. The performance of the GFRP bridge was compared to that of the SC bridge by normalizing the live load and the seismic internal forces with respect to the dead load internal forces. The normalized seismically induced internal forces were compared to the normalized live load internal forces for each design alternative. The study shows that the design alternatives have different dynamic characteristics. The light GFRP alternative has more flexible deck motion in the lateral direction than the heavier SC alternative. While the SC alternative has more vertical deck modes than the GFRP alternative, it has less lateral deck modes than the GFRP alternative in the studied frequency range. The GFRP towers are more flexible in the lateral direction than the SC towers. The GFRP bridge tower attracted less normalized base shear force than the SC bridge towers. However, earthquakes, with peak acceleration of only 0.1 g, and with a variety of frequency content could induce high enough seismic internal forces at the tower bases of the GFRP cable-stayed bridge to govern the structural design of such bridge. Careful seismic analysis, design, and detailing of the tower connections are required to achieve satisfactory seismic performance of GFRP long span bridges.

Controller Auto-tuning Scheme for Improving Feedback System Performance in Frequency Domain (주파수역에서의 피드백시스템의 성능향상을 위한 제어기 Atuo-tuning 기법)

  • 정유철;이건복
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.3
    • /
    • pp.26-30
    • /
    • 2001
  • Controller refinement scheme to improve the performance of a conventional system automatically in frequency domain is proposed. The controller automatic tuning method features using experimental frequency responses of the conventional closed-loop system, the conventional controller, and the improved closed-loop system, instead of poorly modeled plant due to non-linearities and disturbances. The improved closed-loop system characteristics is automatically acquired by the con-ventional closed-loop system characteristics and the proposed performance index in system bandwidth. And the proper controller is realized by least squares approximation in frequency domain. To testify the usefulness of the approach, the path tracking control of robot arm is performed. Experimental results and analytic results are well-matched.

  • PDF

Controller Auto-tuning Scheme using System Monitoring inFrequency Domain (주파수역에서 시스템 감시를 이용한 제어기 Auto-tuning기법)

  • 정유철;이건복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.136-139
    • /
    • 2000
  • Controller refinement scheme to improve the performance of a conventional system automatically in frequency domain is proposed. The controller automatic tuning method features using experimental frequency responses of the conventional closed-loop system, the conventional controller, and the improved closed-Imp system; instead of poorly modeled plant due to non-linearities and disturbances. The improved closed-loop system characteristics is automatically acquired by the conventional closed-loop system characteristics and the proposed performance index in system bandwidth. And the proper controller is realized by least squares approximation in frequency domain. To testify the usefulness of the approach, experimental results of robot path-tracking control applied with various controllers is used, and then is analyzed with respect to a equivalent proportional controller. Experimental results and analytic results are well-matched.

  • PDF

Pulse Propagation Characteristics of Multilayer-Multiconcuctor Transmission Line Network (다층 다도체 선로로 구성된 회로의 펄스전송 특성)

  • 장행종;임영석
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.10
    • /
    • pp.39-47
    • /
    • 1994
  • In this paper, by modeling the Multilayer-Multiconductor Transmission Line(MMTL) with the characteristic parameters-effective dielectric constant, eigen modal voltages, characteristic impedances at each mode, pulse propagation characteristics of MMTL network are simulated. Transmission line modelling is performed in frequency domain, then time domain resposes are obtained by transforming the frequency domain response using fast Fourier transform.

  • PDF

Micro-cantilever sensor using a tuning fork (Tuning fork형 micro-cantilever sensor)

  • Kim Choong Hyun;Ahn Hyo-Sok
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.87-90
    • /
    • 2005
  • An experimental investigation of the basic characteristics of a micro-cantilever sensor was performed by inspecting the amplitude and frequency characteristics using a commercial tuning fork. Application of acetone and ethanol with a volume of $1 {\mu}l$ on the tine of a vibrating tuning fork cause immediate response in its amplitude and frequency. It has shown that the tuning fork has ability to recognize a chemical agent with high sensitivity.

  • PDF

The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer (벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석)

  • Kim, Kwangho;Jung, Jongman;Nah, Wansoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

Wind load characteristics and effects of 1000kV UHV substation frame based on HFFB

  • Hao Tang;Fanghui Li;Xudong Zhi;Jie Zhao
    • Wind and Structures
    • /
    • v.38 no.6
    • /
    • pp.477-492
    • /
    • 2024
  • This study presents a comprehensive investigation of wind load characteristics and wind-induced responses associated with different wind incidence angles and terrains of the 1000kV UHV substation frame. High-frequency force balance (HFFB) force measurement wind tunnel tests are conducted on the overall and segment models to characterize wind loads characteristics such as the aerodynamic force coefficients and the shape factors. The most unfavorable wind incidence angles and terrains for aerodynamic characteristics are obtained. A finite element model of the substation frame is built to determine the wind-induced response characters based on the aerodynamic force coefficients and bottom forces of the segment models. The mean and root mean square (RMS) values of displacement responses at different heights of the frame structure are compared and analyzed. The influence of wind incidence angle and terrains on wind-induced responses is also examined. The displacement responses in terms of the crest factor method are subsequently transformed into dynamic response factors. The recommended values of dynamic response factors at four typical heights have been proposed to provide a reference for the wind resistance design of such structures.

Frequency Characteristics of Micro-cantilever Sensor using Tuning Fork (튜닝포크형 미소 캔틸레버 센서의 주파수 특성)

  • Kim Choong Hyun;Ahn Hyo-Sok
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.5
    • /
    • pp.35-40
    • /
    • 2005
  • An experimental Investigation of the basic characteristics of a micro-cantilever sensor was performed by inspecting the amplitude and frequency characteristics of a commercial tuning fork (TF). Application of acetone and ethanol with a volume of $1{\mu}l$ on the tine of a vibrating tuning fork causes immediate response in its amplitude and frequency characteristics. It has been shown that the tuning fork has ability to recognize a chemical agent with high sensitivity. The theoretical sensitivity of mass loading is in the range of $\~0.1Hz/ng$. Quartz tuning forks are routinely made using standard microfabrication process, thus suggesting the possibility of microfabrication of micro quart sensors.

Evaluating Piezoelectric Thin Film Characteristics Using Resonance Spectrum Method (공진주파수 스펙트럼법을 이용한 압전박막의 특성 평가)

  • Choi Joon Young;Chang Dong Hoon;Kang Seong Jun;Yoon Yung Sup
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.477-480
    • /
    • 2004
  • We studied the characteristics of impedance and electromechanical coupling coefficient in ZnO and AIN thin films by using resonance frequency spectrum method. The response peak of impedance decreased with the decrease of thickness of piezoelectrics, the number of mode of response peak increased with the increase of substrate thickness. An error of $k_{t}^{2}$ estimated from input $k_{t}^{2}$ increased as the thickness of piezoelectrics decreased and the thickness of substrate increased. Also, the error was increased in case of a large acoustic impedance of substrate. It was found that the composite resonator operating in optimized condition could be designed through the resonance frequency spectrum analysis of composited resonator consisted of piezoelectric thin film and substrate.

  • PDF