Protection Assessment using Reduced Power System Fault Data

  • Littler, T.B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.172-177
    • /
    • 2007
  • Wavelet transforms provide basis functions for time-frequency analysis and have properties that are particularly useful for the compression of analogue point on wave transient and disturbance power system signals. This paper evaluates the compression properties of the discrete wavelet transform using actual power system data. The results presented in the paper indicate that reduction ratios up to 10:1 with acceptable distortion are achievable. The paper discusses the application of the reduction method for expedient fault analysis and protection assessment.

바리스터와 LC필터를 사용한 2단 서지보호장치 (Two-Stage Surge Protection Device with Varistor and LC Filter.)

  • 이복희;김지훈;이경옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.279-281
    • /
    • 1996
  • This paper deals with the two stage surge protection device by using varistor and LC low pass filter. Recently varistor alone has been used with overvoltage protection devices for the AC power mains and has same problems associated with high remnant voltage and noise. In this work, in order to improve the cutoff performance of surge protection device, the lightning surge protection device having two stage hybrid circuit for an AC single phase mains was designed and fabricated. Operation characteristics and surge clamping performance of the surge protection device in an $8/20{\mu}s$ surge current are investigated. As a consequence, it is found that the proposed two stage surge protective device for AC power mains has a variety of advantages such as a smaller clamping voltage, high frequency noise reduction and large clamping capacity.

  • PDF

자기동조 주파수 제한기를 갖는 전압원 인버터의 히스테리시스 전류제어 (Hysteresis Current Control with Self-Locked Frequency Limiter for VSI Control)

  • 최연호;임성운;권우현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권1호
    • /
    • pp.23-33
    • /
    • 2002
  • A hysteresis control is widely used to control output current of inverter. A hysteresis bandwidth is affected by system parameters such as source voltage, device on/off time, load inductance and resistance. The frequency limiter is used to protect switching devices overload. In the conventional hysteresis controller, a lock-out circuit with D-latch and timer is used to device protection circuit. But switching delay time and harmonic components are appeared in output current. In this paper the performance of lock-out circuit is tested, and new circuit for switching device fault protection is proposed ad it's performance is simulated.

VVVF 인버터로 구동되는 전기철도차량에서 방출되는 시변 저주파 전자계 분석 (Analysis of time-varying low-frequency electric magnetic field emitted from electric rolling stocks fed by VVVF inverter)

  • 장동욱;김주락;김형철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.507-513
    • /
    • 2010
  • This paper is described the analysis of time-varying low-frequency electric magnetic field emitted from electric rolling stocks fed by VVVF inverter, in reference to allowable magnitude for exposures to time-varying electromagnetic field issued by International Commission on Non-Ionizing Radiation Protection(ICNIRP). The level of the magnetic field strength was measured, in reference to the standard for occupational environments, which takes into account the public person's protection against the excessive emission of the low-frequency magnetic field, 5 Hz ~ 2 kHz.

  • PDF

주파수 특성을 고려한 송전선 보호용 적분근사거리계전 알고리즘의 최적 적분 계수 결정 (Optimal Solution of integral Coefficients in Distance Relaying Algorithm for T/L Protection considering Frequency Characteristics)

  • 조경래;홍준희;정병태;조정현;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.42-44
    • /
    • 1994
  • This paper presents the method of estimating integral coefficients of new distance relaying algorithm for transmission line protection. The proposed method is based on the differential equation calculates impedance value by approximation of integral term of integro-differential equation which relate voltage with current. As a result, we can determine the integral coefficients in least square error sense in frequency domain and we take into consideration the analog filter characteristics and frequency domain characteristics of the system to be protected. The simulation results showed that these coefficients can be successfully used to obtain impedance value in distance relay.

  • PDF

도심 또는 부도심에서 고정무선시스템과 이동기지국 간의 주파수 조정에 대한 연구 (A Study on Frequency Coordination between Fixed Wireless System and Mobile Base Station in Urban or Sub-urban Area)

  • 서경환;박영민
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.41-49
    • /
    • 2017
  • 본 논문에서는 도심 또는 부도심에서 고정무선시스템과 이동기지국 간의 주파수 조정을 위한 이론적 모델링 및 수치해석 결과를 제시한다. 간섭분석에 필요한 주요 변수인 시스템 특성, 전파전파 모델, 보호비, 주파수의존제거, 신호-간섭 평면의 변별각을 고찰하고, 이들에 대해 수치계산을 통해 결과를 도출한다. 최소커플링손실 방법을 기반으로 가정한 고정무선시스템과 이동기지국의 특성에 대해 도심 또는 부도심에서 높이-이득 모델, 변별각, 그리고 거리의 함수로 수신간섭전력을 계산하고, 그 결과들을 보호비로부터 유도된 최대허용간섭전력과 비교한다. 제시된 방법은 다양한 무선시스템의 주파수 조정 또는 재배치 과정에 요구되는 상호 공존 또는 양립성의 기술적 분석에 유용할 것으로 판단된다.

Piezoelectric impedance based damage detection in truss bridges based on time frequency ARMA model

  • Fan, Xingyu;Li, Jun;Hao, Hong
    • Smart Structures and Systems
    • /
    • 제18권3호
    • /
    • pp.501-523
    • /
    • 2016
  • Electromechanical impedance (EMI) based structural health monitoring is performed by measuring the variation in the impedance due to the structural local damage. The impedance signals are acquired from the piezoelectric patches that are bonded on the structural surface. The impedance variation, which is directly related to the mechanical properties of the structure, indicates the presence of local structural damage. Two traditional EMI-based damage detection methods are based on calculating the difference between the measured impedance signals in the frequency domain from the baseline and the current structures. In this paper, a new structural damage detection approach by analyzing the time domain impedance responses is proposed. The measured time domain responses from the piezoelectric transducers will be used for analysis. With the use of the Time Frequency Autoregressive Moving Average (TFARMA) model, a damage index based on Singular Value Decomposition (SVD) is defined to identify the existence of the structural local damage. Experimental studies on a space steel truss bridge model in the laboratory are conducted to verify the proposed approach. Four piezoelectric transducers are attached at different locations and excited by a sweep-frequency signal. The impedance responses at different locations are analyzed with TFARMA model to investigate the effectiveness and performance of the proposed approach. The results demonstrate that the proposed approach is very sensitive and robust in detecting the bolt damage in the gusset plates of steel truss bridges.

Fault ride-through 요구를 고려한 풍력발전단지 연계선 보호 거리계전 알고리즘 (Distance Relaying Algorithm for Intertie Protection of a Wind Farm Considering the Fault Ride-through Requirement)

  • 강용철;강해권;정태영;김연희;이영귀
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1053-1058
    • /
    • 2010
  • A large modern wind farm should satisfy the requirements for a grid and accomplish the optimization of the wind farm system. The wind farm intertie protection system should consider a Fault Ride-Through (FRT) requirement for more reliable protection. The wind farm should keep connected to the grid in the case of a grid fault whilst it should be isolated for an intertie fault. This paper proposes a distance relaying algorithm suitable for wind farm intertie protection considering the FRT requirement. The proposed algorithm estimates the impedance based on a differential equation method because the frequency of the voltage and current deviates the nominal frequency. The algorithm extends the reach of Zone 1 up to 100 % of the length of the intertie to implement the FRT requirement. To discriminate an intertie fault from a grid fault, the algorithm uses a voltage blocking scheme because the magnitude of the voltage at the relaying point for an intertie fault becomes less than that for a grid fault. The performance of the algorithm is verified using a PSCAD/EMTDC simulator under various fault conditions. The algorithm can discriminate successfully the intertie fault from grid fault and thus helps to implement the FRT requirement of a wind farm.

Methodology for Risk Assessment for Exposure to Hurricane Conditions

  • Edge, Billy L.;Jung, Kwang-Hyo
    • International Journal of Ocean System Engineering
    • /
    • 제2권1호
    • /
    • pp.37-49
    • /
    • 2012
  • An analysis of potential flooding by storm surge and wave run-up and overtopping can be used to evaluate protection afforded by the existing storm protection system. The analysis procedure can also be used to evaluate various protection alternatives for providing typhoon flood protection. To determine risk, the storm surges for both historical and hypothetical are compiled with tide conditions to represent high, slack and low water for neap, spring and mid range tides to use with the statistical procedure known as the Empirical Simulations Technique (EST). The EST uses the historic and hypothetical events to generate a large population of life-cycle databases that are used to compute mean value maximum storm surge elevation frequency relationships. The frequency-of-occurrence relationship is determined for all relevant locations along the shoreline at appropriate locations to identify the effect using the Empirical Storm Simulation (EST). To assist with understanding the process, an example is presented for a study of storm surge analysis for Freeport, Texas. This location is in the Gulf of Mexico and is subject to hurricanes and other tropical storms that approach from the Atlantic Ocean.

리클로져의 동작특성을 고려한 계통연계형 태양광발전시스템의 보호 알고리즘 (A Protection Algorithm of Grid-Interactive Photovoltaic System Considering Operation Characteristics of Recloser)

  • 김슬기;김응상
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.280-286
    • /
    • 2006
  • The paper proposes a new protection algorithm for reliable operation of grid-interfaced PV system, which can flexibly interact with conventional protective schemes of power utility grid not only to prevent damages to utility or public persons and utility apparatus caused by malfunction or failure in distribution network protection system, but also to protect a PV system itself from faults or abnormal conditions of the network. The proposed algorithm is based on reclosing characteristics of the distribution system. As a network fault occurs, the new scheme determines whether it is momentary or permanent and responds in a pre-programmed way to the fault. For permanent outage, the proposed algorithm shuts down inverter's operations but monitoring system voltage and frequency at the point of common coupling with grid. When it comes to the momentary outage, Inverter starts stand-by operation mode so that it can be automatically connected to the grid without start-up procedures as soon as the system voltage and frequency returns into the normal operation range. In order to investigate' and evaluate the PV system operation, simulation study based on PSCAD/EMTDC has been carried out to verify the performance of the proposed protection scheme.