• 제목/요약/키워드: Frequency protection

검색결과 875건 처리시간 0.029초

Simulations of Frequency-dependent Impedance of Ground Rods Considering Multi-layered Soil Structures

  • Lee, Bok-Hee;Joe, Jeong-Hyeon;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.531-537
    • /
    • 2009
  • Lightning has a broad frequency spectrum from DC to a few MHz. Consequently, the high frequency performance of grounding systems for protection against lightning should be evaluated, with the distributed parameter circuit model in a uniform soil being used to simulate grounding impedances. This paper proposes a simulation method which applies the distributed parameter circuit model for the frequency-dependent impedance of vertically driven ground rods by considering multi-layered soil structures where ground rods are buried. The Matlab program was used to calculate the frequency-dependent ground impedances for two ground rods of different lengths. As a result, an increase of the length of ground rod is not always followed by a decrease of grounding impedance, at least at a high frequency. The results obtained using the newly proposed simulation method considering multi-layered soil structures are in good agreement with the measured results.

디지털 보호 계전기를 위한 주파수 변동 보상기의 설계 (The Design of Frequency Variation Compensator for Digital Protection Relay)

  • 김병진;이보인;김정한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.563-565
    • /
    • 2002
  • The designed frequency compensator is proposed to make the estimation of amplitude of fundamental frequency immune to frequency variation. The designed method which has a simple structure and low calculation burden is proper to apply digital protective relay. The results of experimental demonstrate that the frequency compensator has good performance to the estimation of amplitude of fundamental frequency against frequency variation.

  • PDF

교류가 유도되는 매설배관에서의 교류 부식속도 측정에 관한 연구 (Corrosion Rate of Buried Pipeline by Induced Alternating Current)

  • 송홍석;김영근;이성민;고영태;박용수
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2001년도 추계학술발표회 논문집
    • /
    • pp.45-57
    • /
    • 2001
  • An alternating current (AC) corrosion using coupon has been studied. Coupons were applied in terms of AC voltage from high value to low value through the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion(: below -850mv vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relationship could be obtained statistically, in which AC corrosion rate increased linearly with effective AC current density and its slope was 0.619.

  • PDF

광대역 과도전압 차단장치의 설계 및 제작 (Design and Fabrication of Wide-band Transient Voltage Blocking Device)

  • 송재용;이종혁;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 춘계종합학술대회
    • /
    • pp.330-334
    • /
    • 1999
  • This paper presents a new transient voltage blocking device (TBD) for commucation facilities with low power and high frequency bandwidth. Conventional protection devices have some problems such as low frequency bandwidth, low energy capacity and high remnant voltage. In order to improve these limitations, the new TBD, which consists of a gas tube, avalanche diodes and junction type field effect transistors (JFETs), was designed and fabricated JFETs were used as an active non-linear element and a high speed switching diode with low capacitance limits high current. Therefore the avalanche diodes with low energy capacity are protected from the high current, and the TBD has a very small input capacitance. From the performance test using surge generator, which can produce 1.2/50${\mu}\textrm{s}$ 4.2 k$V_{max}$, 8/20${\mu}\textrm{s}$ 2.1 kA$\sub$max/, it is confirmed that the proposed TBD has an excellent protection performance in tight clamping voltage and limiting current characteristics.

  • PDF

HID 램프용 전자식 안정기 개발 연구 (A Study on the Development of the Electronic Ballast for HID Lamps)

  • 이호;오성철;위상봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1082-1084
    • /
    • 2001
  • This paper presents a design techniques for an electronic ballast of HID lamps. An electronic ballast for HID lamps usually employs a high frequency resonant inverter and voltage-to-frequency converter to control the output and a half-bridge and series resonant circuit are chosen for the ballast. In this paper, the new lighting method for the stable ignition regardless of lamp types is designed. And this type of ballast has some useful functions such as surge protection, thermal protection, and dimmable function. Moreover the powerline communication skill is also used to transmit a dimming control signal.

  • PDF

저 전압 트리거형 ESD 보호회로를 탑재한 저 전압 Step-down DC-DC Converter 설계 (The Design of low voltage step-down DC-DC Converter with ESD protection device of low voltage triggering characteristics)

  • 육승범;이재현;구용서
    • 전기전자학회논문지
    • /
    • 제10권2호통권19호
    • /
    • pp.149-155
    • /
    • 2006
  • In this study, the design of low voltage DC-DC converter with low triggering ESD (Electro-Static Discharge) protection circuit was investigated. The purpose of this paper is design optimization for low voltage(2.5V to 5.5V input range) DC-DC converter using CMOS switch. In CMOS switch environment, a dominant loss component is not switching loss but conduction loss at 1.2MHz switching frequency. In this study a constant frequency PWM converter with synchronous rectifier is used. And zener Triggered SCR device to protect the ESD phenomenon was designed. This structure reduces the trigger voltage by making the zener junction between the lateral PNP and base of lateral NPN in SCR structure. The triggering voltage was simulated to 8V.

  • PDF

단순병렬 자가발전 설비 보호방식 검토 사례 (A case Study for Protection Relay System of small Cogeneration intertie)

  • 이승재;김경식;윤갑구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.234-236
    • /
    • 2002
  • The Co-Gen System which maximize energy efficiency was installed at the industrial plants at the initial stage. However Small Scale Co-Gen System was expanded even to the general end-users such as housing and building owing to ESCO business recently. For this SSC, inter-connected operation to the utility is desirable due to voltage and frequency fluctuation following to unbalance between power output and load. Then voltage unbalance with utility system, frequency, increase of short circuit capacity, reclosing, and ALTS etc. should be fully considered for the inter-connected operation. Voltage variation, protection coordination, Co-Generators single running, and short circuit capacity should also be solved. To research the method and solve the problems through the field test and application, we study individual customers Co-Gen System as a case study.

  • PDF

Corrosion Rate of Buried Pipeline by Alternating Current

  • Song, H.S.;Kim, Y.G.;Lee, S.M.;Kho, Y.T.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2005
  • An alternating current (AC) corrosion on buried pipeline has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites from high value of AC voltage to low value based on the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion (; below -850 mV vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and its slope was 0.619 in coupon method and 0.885 in ER probes.

디지털 영상물의 저작권 보호를 위한 적응적 정보 은닉 기술에 관한 연구 (A Study on Adaptive Information Hiding Technique for Copyright Protection of Digital Images)

  • 박강서;정태윤;오상록;박상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2427-2429
    • /
    • 1998
  • Digital watermarking is the techinque which embeds the invisible signal into multimedia data such as audio, video, images, for copyright protection, including owner identification and copy control information. This paper proposes a new watermark embedding and extraction technique by extending the direct sequence spread spectrum technique. The proposed technique approximates the frequency component of pixels in spatial domain by using Laplacian mask and adaptively embeds the watermark considering the HVS to reduce the degradation of Image. In watermark extraction process, the proposed technique strengthens the high frequency components of image and extracts the watermark by demodulation. All this processes are performed in spatial domain to reduce the processing time.

  • PDF

Numerical and experimental studies of a building with roller seismic isolation bearings

  • Ortiz, Nelson A.;Magluta, Carlos;Roitman, Ney
    • Structural Engineering and Mechanics
    • /
    • 제54권3호
    • /
    • pp.475-489
    • /
    • 2015
  • This study presents the validation of a numerical model developed for dynamic analysis of buildings with roller seismic isolation bearings. Experimental methods allowed validation of the motion equations of a physical model of a building with and without roller bearings under base excitation. The results are presented in terms of modal parameters, frequency response functions (FRFs) and acceleration response. The agreement between numerical and experimental results proves the accuracy of the developed numerical model. Finally, the performance of the constructed seismic protection system is assessed through a parametric study.