• Title/Summary/Keyword: Frequency phase response

Search Result 413, Processing Time 0.028 seconds

Weighted Least-Squares Design and Parallel Implementation of Variable FIR Filters

  • Deng, Tian-Bo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.686-689
    • /
    • 2002
  • This paper proposes a weighted least-squares(WLS) method for designing variable one-dimensional (1-D) FIR digital filters with simultaneously variable magnitude and variable non-integer phase-delay responses. First, the coefficients of a variable FIR filter are represented as the two-dimensional (2-D) polynomials of a pair of spectral parameters: one is for tuning the magnitude response, and the other is for varying its non-integer phase-delay response. Then the optimal coefficients of the 2-D polynomials are found by minimizing the total weighted squared error of the variable frequency response. Finally, we show that the resulting variable FIR filter can be implemented in a parallel form, which is suitable for high-speed signal processing.

  • PDF

Controlling Factors of Open-Loop Combustion Response to Acoustic Pressures in Liquid Propellant Rocket Engine (강한 압력파동에 구속된 액체 추진제 연소응답의 지배인자)

  • Yoon Woongsup;Lee Gilyong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.267-273
    • /
    • 2004
  • This paper targets to define controlling factors of pressure-coupled combustion response and estimate their effects on droplet evaporation process. Dynamic characteristics of hydrocarbon propellant vaporization perturbed by acoustic pressure are numerically simulated and analyzed. 1-D droplet model including phase equilibrium between two phases is applied and acoustic wave is expressed by harmonic function. Effects of various design factors and acoustic pressure on combustion response are investigated with parametric studies. Results show that driving frequency of acoustic perturbation and ambient pressure have important roles in determining magnitude and phase of combustion response. On the other hand, other parameters such as gas temperature, initial droplet size and temperature, and amplitude of acoustic wave cause only minor changes to magnitude of combustion response. Resultant changes in phase of heat of vaporization and thermal wave in droplet highly influence magnitude and phase of combustion response.

  • PDF

Ultrasonic Image of the Side Drilled Holes in SS Reference Block as Combining Bases of Support for Spatial Frequency Response

  • Koo, Kil-Mo;Song, Chul-Hwa;Beak, Won-Pil;Kang, Hee-Young
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.322-326
    • /
    • 2008
  • In this paper, we have studied the images which have been reconstructed by using combination of images acquired by the variation of operating frequency. When inner images have been reconstructed, they have been superposed by the surface state effect. In this case, the images of the phase object can be enhanced by the contrast of inner images. There is a kind of specimen, one is a reference block having 1/4T, 1/2T, 3/4T side drilled holes as main run piping material of the steam generator in nuclear power plants. It has been shown that the two results of defect shapes have better than before in this processing and phase contrast grow about twice. And we have constructed the acoustic microscope by using a quadrature detector that enables to acquire the amplitude and phase of the reflected signal simultaneously. Further more we have studied the reconstruction method of the amplitude and phase images, the enhancement method of the defect images' contrast.

  • PDF

Noise Reduction of Anti-phase Shifting to Maximum Amplitude Response in a Helmet (최대 진폭 응답으로 역위상을 천이시킨 헬멧에서의 소음감쇠 기법)

  • 조병모
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.7
    • /
    • pp.13-20
    • /
    • 2001
  • The active noise cancellation system offers a better low frequency performance with a smaller and lighter system compared to a passive one. This paper presents an active noise control system capable of reducing the noise in a helmet after attenuating the external noise using the helmet as the passive noise reduction system, which consists of a controller for inverting and compensating the phase delay, a microphone for picking up the external noise, and a loudspeaker for radiating the acoustic anti-phase signal to reduce the external noise. In this paper, external noise can be reduced by noise controller by compensating the phase difference to be 180°in the frequency of maximun value in the amplitude response. The noise of the phase delay covered from 50°to 310°was reduced in this system and it is possible to obtain a noise reduction of up to approximately 20 dB at the ears in the enclosure.

  • PDF

CFD-FSI simulation of vortex-induced vibrations of a circular cylinder with low mass-damping

  • Borna, Amir;Habashi, Wagdi G.;McClure, Ghyslaine;Nadarajah, Siva K.
    • Wind and Structures
    • /
    • v.16 no.5
    • /
    • pp.411-431
    • /
    • 2013
  • A computational study of vortex-induced transverse vibrations of a cylinder with low mass-damping is presented. An Arbitrary Lagrangian-Eulerian (ALE) formulation of the Unsteady Reynolds-Averaged Navier-Stokes equations (URANS), along with the Spalart-Allmaras (SA) one-equation turbulence model, are coupled conservatively with rigid body motion equations of the cylinder mounted on elastic supports in order to study the amplitude and frequency response of a freely vibrating cylinder, its flow-induced motion, Vortex Street, near-wake flow structure, and unsteady loading in a moderate range of Reynolds numbers. The time accurate response of the cylinder from rest to its limit cycle is studied to explore the effects of Reynolds number on the start of large displacements, motion amplitude, and frequency. The computational results are compared with published physical experiments and numerical studies. The maximum amplitudes of displacements computed for various Reynolds numbers are smaller than the experimental values; however, the overall agreement of the results is quite satisfactory, and the upper branch of the limit-cycle displacement amplitude vs. reduced velocity response is captured, a feature that was missed by other studies. Vortex shedding modes, lock-in phenomena, frequency response, and phase angles are also in agreement with experiments.

Fast Extraction of Symmetrical Components from Distorted Three-Phase Signals Based on Asynchronous-Rotational Reference Frame

  • Hao, Tianqu;Gao, Feng;Xu, Tao
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.1045-1053
    • /
    • 2019
  • A symmetrical component decomposition scheme utilizing the characteristics of the asynchronous rotational reference frame transformation is proposed in this paper for the extraction of the positive and negative sequence components of distorted three-phase grid voltages. The undesired frequency component can be removed using a specially designed series coordinate transformation and half-cycle delays, where the delay can be controlled by adjusting the frequency of the rotating reference frame. The extracted symmetrical component can then be compensated based on the applied coordinated transformation. The dynamic response of the proposed algorithm is improved when compared to that of conventional methods. The effectiveness of the proposed algorithm is verified by simulation and experimental results.

Implementation and Test of Hydraulic Control System for the Tractor Leveling (트랙터의 수평제어를 위한 유압 시스템의 특성 실험)

  • Lee, S. S.;Oh, K. S.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.24 no.5
    • /
    • pp.383-390
    • /
    • 1999
  • When a tractor travels slope lands, problems of operator safety and the reduction of job efficiency usually occur. Therefore, maintaining the tractor body being horizontal is critical to improve the security of traveling and the job performance. An experiment was made in a soil bin using the experimental model system built and equipped with a leveling control system. Adaptability of the control system was tested and investigated by analyzing system response in time and frequency domains. Control response time of hydraulic cylinder with 10lpm flow rate on a step input of 10$^{\circ}$slope was about 0.42sec. And it showed a linearly increasing trend without any hunching state. A steady state error of 0.6$^{\circ}$occurred but it was negligible. The hydraulic control system showed a little phase differences within the range of 0.4Hz input frequency. The experimental model showed that implementation of the proposed tractor control system to on slope lands tractor was feasible.

  • PDF

Variable-Speed Prime Mover Driving Three-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation-Part H : Simulation and Experimental Results-

  • Ahmed, Tarek;Nagai, Schinichro;Soshin, Koji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.10-15
    • /
    • 2003
  • This paper presents the digital computer performance evaluations of the three-phase self-excited induction generator (SEIG) driven by the variable speed prime mover such as the wind turbine using the nodal admittance approach steady-state frequency domain analysis with the experimental results. The three-phase SEIG setup is implemented for small-scale rural renewable energy utilizations. The experimental performance results give a good agreement with those ones obtained from the digital computer simulation. Furthermore, a feedback closed-loop voltage regulation of the three-phase SEIG as a power conditioner which is driven by a variable speed prime mover employing the static VAR compensator (SVC) circuit composed of the thyristor phase controlled reactor (TCR) and the thyristor switched capacitor(TSC) is designed and considered herein for the wind-turbine driven the power conditioner. To validate the effectiveness of the SVC-based voltage regulator of the terminal voltage of the three-phase SEIG, an inductive load parameter disturbances in stand-alone are applied and characterized in this paper. In the stand-alone power utilization system, the terminal voltage response and thyristor triggering angle response of the TCR are plotted graphically. The simulation and the experimental results prove the effectiveness and validity of the proposed SVC which is controlled by the Pl controller in terms of fast response and high performances of the three-phase SEIG driven directly by the rural renewable energy utilization like a variable-speed prime mover.

Inverter Drives Adopting the Two-Phase Space Vector SRP-PWM Scheme with Fixed Switching Frequency (고정 스위칭 주파수를 갖는 2상 공간벡터 SRP-PWM기법을 적용한 인버터 구동 시스템)

  • 정영국;위석오;임영철;양승학
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.230-238
    • /
    • 2003
  • In this paper, Inverter drives adopting 2 phase space vector SRP-PWM (Separately Randomized Pulse Position PWM) with fixed switching frequency is proposed. The proposed 2 phase space vector SRP-PWM scheme is based on the 3 phase SRP-PWM. In the proposed SRP-PWM scheme, each of two phase pulses is located randomly in each switching interval. The experimental results show that the voltage and acoustic noise harmonics are spread to a wide band area. Also, the performance of the proposed 2 phase SRP-PWM and the conventional center aligned SVM are compared to each other. In result, the speed response is nearly similar to each other from the viewpoint of the v/f constant control.

A Study on Mathematical Modeling of Forcing Function for the Piping Vibration of Petrochemical Plant Design (플랜트 설계 시 배관진동을 유발하는 가진 함수의 수학적 모델링)

  • 민선규;최명진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.591-595
    • /
    • 1997
  • In analysis of piping vibration of petrochemical plant, the forcing functions mainly depend upon the equipment working mechanism and vibration resources in the piping systems. In general, harmonic function is used for the system with rotary equipments. Mechanical driving frequencies, wave functions, and response spectrum are used for reciprocating compressors, surge vibration of long transfer piping, and seismic/wind vibration, respectively. In this study, for the spray injection case inside the pipe, forcing function was modeled, in which two different fluids are distributed uniformly. To confirm the results, the scheme used for the forcing function was applied for real piping system. The vibration mode of the real system was consistent with the 4th mode obtained by simulation using the forcing function formulated in this study.

  • PDF