• Title/Summary/Keyword: Frequency measurement

Search Result 4,236, Processing Time 0.034 seconds

A Review of the Pain and Function Assessment Instruments for Shoulder Disease Patients in Korean Medicine Clinical Studies Published in South Korea (국내 한의임상연구에서의 어깨질환 환자의 통증 및 기능측정도구 사용에 대한 현황분석)

  • Lee, Geon-Yeong;Jo, Hee-Geun;Seol, Jae-Uk;Kim, Shin-Ae
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.1
    • /
    • pp.33-51
    • /
    • 2018
  • Objectives The purpose of this study is to analyze the current status of measurement instruments used to evaluate pain and function for shoulder disease patients in Korean Medicine clinical studies published in South Korea. Methods 5 Korean online databases from January 2007 to July 2017 were used to source articles for the review. Data of pain and function assessment instruments, measurement methods, time point and frequency for shoulder assessment were extracted. And it was analyzed by investigating the frequency of use for each item. Results A total of 78 studies met the selection criteria. There were many studies with no description for pain assessment instruments or inconsistent measurement methods. In the function assessment, the frequency of use was low and there were a lot of use of instruments with low validity and reliability. Conclusions To develop the objectivity of clinical research, further clinical studies, active use of measurement instruments, and standardization of measurement methods are needed.

An integrated visual-inertial technique for structural displacement and velocity measurement

  • Chang, C.C.;Xiao, X.H.
    • Smart Structures and Systems
    • /
    • v.6 no.9
    • /
    • pp.1025-1039
    • /
    • 2010
  • Measuring displacement response for civil structures is very important for assessing their performance, safety and integrity. Recently, video-based techniques that utilize low-cost high-resolution digital cameras have been developed for such an application. These techniques however have relatively low sampling frequency and the results are usually contaminated with noises. In this study, an integrated visual-inertial measurement method that combines a monocular videogrammetric displacement measurement technique and a collocated accelerometer is proposed for displacement and velocity measurement of civil engineering structures. The monocular videogrammetric technique extracts three-dimensional translation and rotation of a planar target from an image sequence recorded by one camera. The obtained displacement is then fused with acceleration measured from a collocated accelerometer using a multi-rate Kalman filter with smoothing technique. This data fusion not only can improve the accuracy and the frequency bandwidth of displacement measurement but also provide estimate for velocity. The proposed measurement technique is illustrated by a shake table test and a pedestrian bridge test. Results show that the fusion of displacement and acceleration can mitigate their respective limitations and produce more accurate displacement and velocity responses with a broader frequency bandwidth.

Development of Measurement System for Quantitative Measurement of Cantilever in Atomic Force Microscopy (원자간격 현미경의 캔틸레버의 정량적 특성평가를 위한 계측 시스템 개발)

  • Kweon, Hyun-Kyu;Nam, Ki-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.2
    • /
    • pp.22-27
    • /
    • 2007
  • In this study, the two methods of stiffness measurement(Spring constant) of cantilever were proposed for quantitative measurement in Atomic Force Microscopy(AFM). As the 1st method for the measurement of stiffness, the probe method, which is used in the measurement of the semiconductor mechanical and electrical properties, was applied to the measurement of the cantilever. Experiments by the probe method were performed finding the resistance value of cantilever. As the results, the resistance was measured differently along with the dimension and the thickness of cantilever that determined the stiffness(spring constant) of the lever. As the 2nd method, the vibration characteristics(Dunkerley expression) is used to obtain the stiffness of the complex structure which is combined by AFM cantilever and the standard cantilever. We measured the resonant frequency from the complex structure using the micro stages and stereo microscope. As the results, we confirmed that the vibration characteristics(Dunkerley expression) is effected the micro complex structure of AFM cantilever.

  • PDF

High-Frequency Equivalent Circuit Model for Differential Mode Noise Analysis of DC-DC Buck Converter (DC-DC 벅 컨버터의 차동모드 노이즈 분석을 위한 고주파 등가회로 모델)

  • Shin, Juhyun;Kim, Woojung;Cha, Hanju
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.473-480
    • /
    • 2020
  • In this paper, we proposed a high frequency equivalent circuit considering parasitic impedance components for differential noise analysis on the input stage during DC-DC buck converter switching operation. Based on the proposed equivalent circuit model, we presented a method to measure parasitic impedance parameters included in DC bus plate, IGBT, and PCB track using the gain phase method of a network analyzer. In order to verify the validity of this model, a DC-DC prototype consisting of a buck converter, a signal analyzer, and a LISN device, and then resonance frequency was measured in the frequency range between 150 kHz and 30 MHz. The validity of the parasitic impedance measurement method and the proposed equivalent model is verified by deriving that the measured resonance frequency and the resonance frequency of the proposed high frequency equivalent model are the same.

Quantitative study of acupuncture manipulation of lifting-thrusting using an needle insertion-measurement system in phantom tissue

  • Lee, Soo-Yoon;Son, Young-Nam;Choi, In-Hwa;Shin, Kyung-Min;Kim, Kap-Sung;Lee, Seung-Deok
    • The Journal of Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.74-82
    • /
    • 2014
  • Objectives: Quantification, objectification, and standardization of lifting-thrusting manipulation are important issues in traditional Chinese medicine (TCM). The purpose of this study was to quantitatively investigate the difference in the amount of stimulation according to range and frequency among parameters of lifting-thrusting manipulation with the use of a needle insertion-measurement system. Methods: For quantification of lifting-thrusting manipulation, an acupuncture needle insertion-measurement system was used in phantom tissue. The motor and force sensors of the needle insertion device were connected to the control software. This enabled operation of the lifting-thrusting manipulation and measurement of the acupuncture needle force. The measurement of the acupuncture needle force according to various frequencies (0.25, 0.50, 0.75, and 1 Hz) and ranges of movement (2, 4, 6, 8, and 10 mm) was repeated 10 times. Results: At a constant frequency of movement, acupuncture needle force according to range of movement (2, 4, 6, 8, and 10 mm) increased with increasing range of movement (p < 0.05). At a constant range of movement, acupuncture needle force according to frequency of movement (0.25, 0.50, 0.75, and 1.0 Hz) increased with increasing frequency of movement (p < 0.05). Conclusion: In this study, we conducted a quantitative comparison of the amount of stimulation according to range and frequency, the main parameters of lifting-thrusting manipulation, by using an acupuncture needle insertion-measurement system. Future studies on various manipulations and parameters are warranted to quantify and objectify the amounts of stimulation by acupuncture manipulation.

A wireless high-frequency anemometer instrumentation system for field measurements

  • Huang, Guoqing;Peng, Liuliu;Su, Yanwen;Liao, Haili;Li, Mingshui
    • Wind and Structures
    • /
    • v.20 no.6
    • /
    • pp.739-749
    • /
    • 2015
  • Field measurement of wind characteristics is of great significance for the wind engineering community. High-frequency anemometers such as ultrasonic anemometers are widely used to obtain the high-frequency fluctuating wind speed time history. However, conventional instrumentation systems may suffer from low efficiency, non-real time transmission and higher maintenance cost, and thus are not very appropriate in the field measurement of strong winds in remote areas such as mountain valleys. In order to improve the field measurement performance in those remote areas, a wireless high-frequency anemometer instrumentation system for field measurement has been developed. In this paper, the architecture of the proposed instrumentation system, and measured data transmission and treatment will be presented firstly. Then a comparison among existing instrumentation systems and the proposed one is made. It shows that the newly-developed system has considerable advantages. Furthermore, the application of this system to the bridge site located in the mountain valley is discussed. Finally, typical samples of measured data from this area are presented. It can be expected that the proposed system has a great application potential in the wind field measurement for remote areas such as the mountainous or island or coastal area, and hazardous structures such as ultra-voltage transmission tower, due to its real-time transmission, low cost and no manual collection of data and convenience.

Telemetering System of Extremely Low Frequency Magnetic Field Intensity (극저주파 자계 세기를 원격 측정하는 장치)

  • Yoo, Ho-Sang;Wang, Jong-Uk;Seo, Geun-Mee;Gimm, Yoon-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.553-562
    • /
    • 2007
  • In this paper, we designed and implemented the system for telemetering ELF(Extremely Low Frequency) magnetic field intensity. The magnetic field measurement system used a 3-axis magnetic field sensor to measure the magnetic field with isotropy and the equalizer to compensate the frequency characteristic in band. By multiplexing three output signals of the magnetic field sensor in time domain, we got the uniform gain and frequency characteristic among three axes. This system was designed that the magnetic field measurement level range was $0.01{\sim}10.0\;uT$ and the measurement frequency band was $40{\sim}180\;Hz$. The control system would access to the magnetic field measurement system with RF and the maximum access distance was 1.0 km. We confirmed that the measurement level error of the fabricated system was within 5 %. The fabricated system was installed to a golf practice range where a high voltage power transmission line was crossed.

Low Frequency Noise Characteristics of the 180nm MOSFETs

  • Yoon, Young-Chang;Lee, Ho-Cheol;Kang, In-Man;Shin, Hyung-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.861-864
    • /
    • 2005
  • Performing accurate and repeatable low frequency noise measurement is critical for modeling and simulation of flicker noise. Through the accurate and repeatable on-wafer measurement, low frequency noise characteristics of the 0.18 ${\mu}m$ n-MOSFETs are discussed. And on-wafer flicker noise measurement system is presented. The on-wafer measurement system consists of cascade probe station, low noise current amplifier (SR570), and dynamic signal analyzer (HP35670A).

  • PDF

Measurement Techniques on Unsteady Flow at Impeller Exit (임펠러 출구에서의 비정상 유동 측정 기법)

  • Shin, You-Hwan;Kim, Kwang-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.123-128
    • /
    • 1998
  • This study presents the measurement techniques on the periodic fluctuating flow such as the discharge flow of a centrifugal impeller in unstable operating region. During rotating stall, the flow at the exit of a centrifugal compressor impeller fluctuates periodically with lower frequency than that of the blade passing. To observe the blade-to-blade flow characteristics during rotating stall, the phases of all the sampled data sets should be adjusted to those of the reference signals with two processes, in these processes, DPLEAT (Double Phase-Locked Ensemble Averaging Technique) can be used. From these measurement and data processing techniques, the characteristics not only on the blade-to-blade flow with high frequency, but also on the periodic rotating stall flow with low frequency at the centrifugal impeller exit can be clearly observed.

  • PDF

An Fundamental Study on the Measurement of Cement Mortar Unit-Water Content Using High Frequency Moisture Sensor (고주파 수분 센서를 이용한 시멘트 모르타르의 단위수량 측정에 관한 기초적 연구)

  • Cho, Yang-Je;Kim, Min-Seo;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.6-7
    • /
    • 2020
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF