• Title/Summary/Keyword: Frequency component

Search Result 1,809, Processing Time 0.039 seconds

Bandwidth Effect on the Dispersion Monitoring of CSRZ Signal Based on Clock Component (CSRZ 신호의 클럭 성분을 이용한 색분산 감시법에서 송수신단 대역폭의 영향 분석)

  • Kim, Sung-Man
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.9
    • /
    • pp.1343-1349
    • /
    • 2013
  • In optical fiber communications, several newly-developed signal formats are used to obtain the best performance within limited spectral bandwidth. CSRZ (carrier-suppressed return-to-zero) format is one of the new signal formats, which has better spectral efficiency and better robustness to dispersion than RZ (return-to-zero) format. Thus it is widely used for demonstrating high-speed optical communication systems. In an earlier research, we proposed a clock-extraction method of CSRZ signal to monitor chromatic dispersion. However, the clock-frequency component extracted by the clock-extraction method can be affected by the bandwidth of a transmitter or a receiver. Therefore, in this paper, we investigate the effect of bandwidth on the chromatic dispersion monitoring of CSRZ signal based on clock-frequency component. As a result, we propose a couple of robust clock-extraction methods to monitor chromatic dispersion in CSRZ signal.

Time-varying characteristics analysis of vehicle-bridge interaction system using an accurate time-frequency method

  • Tian-Li Huang;Lei Tang;Chen-Lu Zhan;Xu-Qiang Shang;Ning-Bo Wang;Wei-Xin Ren
    • Smart Structures and Systems
    • /
    • v.33 no.2
    • /
    • pp.145-163
    • /
    • 2024
  • The evaluation of dynamic characteristics of bridges under operational traffic loads is a crucial aspect of bridge structural health monitoring. In the vehicle-bridge interaction (VBI) system, the vibration responses of bridge exhibit time-varying characteristics. To address this issue, an accurate time-frequency analysis method that combines the autoregressive power spectrum based empirical wavelet transform (AR-EWT) and local maximum synchrosqueezing transform (LMSST) is proposed to identify the time-varying instantaneous frequencies (IFs) of the bridge in the VBI system. The AR-EWT method decomposes the vibration response of the bridge into mono-component signals. Then, LMSST is employed to identify the IFs of each mono-component signal. The AR-EWT combined with the LMSST method (AR-EWT+LMSST) can resolve the problem that LMSST cannot effectively identify the multi-component signals with weak amplitude components. The proposed AR-EWT+LMSST method is compared with some advanced time-frequency analysis techniques such as synchrosqueezing transform (SST), synchroextracting transform (SET), and LMSST. The results demonstrate that the proposed AR-EWT+LMSST method can improve the accuracy of identified IFs. The effectiveness and applicability of the proposed method are validated through a multi-component signal, a VBI numerical model with a four-degree-of-freedom half-car, and a VBI model experiment. The effect of vehicle characteristics, vehicle speed, and road surface roughness on the identified IFs of bridge are investigated.

Substructure Synthesis Method using Dynamic Reduction (동축소법을 이용한 부분구조합성법)

  • 박석주;박성현;김성우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.82-87
    • /
    • 2000
  • The component mode synthesis method(CMS) used for vibration analysis has demerit that error becomes larger, as degree of natural frequency grows higher. The reason of error occurrence is that Guyan's static reduction is used and the number of modes taken in each component is deficient. This paper proposes the substructure synthesis method using dynamic reduction to solve the problem from the component mode synthesis method. Computer simulation for the proposed method. FEM and the component mode synthesis method(CMS) on a rectrangular plate has been carried out to prove the avilability of the proposed method.

  • PDF

A Study on the Influence of Cutting Conditions on the Dynamic Component of Cutting Resistance(ll) (절삭저항의 동적성분에 미치는 절삭조건의 영향에 관한 연구(II))

  • Jeon, Eun-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.1 no.2
    • /
    • pp.58-68
    • /
    • 1984
  • In this study, the static and dynamic components of cutting resistance were measured with tool dynamometer (Swiss, pieso-electric type) when S45C, A1-alloy and brass were drilled under the some variable conditions. The results obtained are as follows; 1) The dynamic components of these cutting resistance are not related to the depth of drilled hole. 2) The static and dynamic components of cutting resistance are increased in accordance with the increase of feed and drill diameter. 3) The dynamic components of thrust force are increased in accordance with the increase of spindle speed. 4) The rate of the dynamic component to the static component is 0.3 .approx. 0.5 in torque, 0.1 .approx. 0.2 in thrust force. 5) The characteristic of the tool system is affected in dynamic component of cutting resistance, and the creasted frequency and amplitude of the chip are determined by the crilled materials. 6) The maximum amplitude of the dynamic component is increased proportionally in accordance with the feed rate and the spindle speed.

  • PDF

Disturbance countermeasurement of depth control system using adaptive notch filter (적응노치필터를 이용한 심도제어시스템 외란처리)

  • 김윤호;윤형식;임재환;이석필;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.86-89
    • /
    • 1992
  • One of the most difficult problems in depth control for underwater vehicle is the effect of seaway disturbance. One component of the seaway forces is of large magnitude with a relatively narrow-band, first order component. The other component is generaly of somewhat smaller magnitude, second order component. Since the magnitude of the first order component is generally much greater than the compensating force that can be generating by the planes, it is undesirable for the controller to generate a control command. In this paper, we disigned adaptive notch filtering system using filter bank structure. Energies of each band-passed signal are obtained by MA(Moving Average) method and compared to produce center frequency. By adapting this parameter to notch filter, 1st order seaway disturbance can be removed, which lead to the improvement of automatic depth control system.

  • PDF

Visual Perception of Garment Surface Appearance

  • Fan, Jintu;Liu, Fu
    • Science of Emotion and Sensibility
    • /
    • v.5 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • This paper concerns with the relationship between the visual perception of the degree of pucker or wrinkles of garment surfaces and the geometrical parameters of surfaces. In this study, four potentially relevant parameters of the surface profile are considered, namely, the variance ($\sigma$$^2$), the cutting frequency (F$\_$c/), the effective disparity curvature (D$\_$ce/) (Defined as the average disparity curvature of the wrinkled surface over the eyeball distance of the observer) and the frequency component of the disparity curvature ( D$\_$cf/). Based on the experiments using garment seams having varying degree of pucker (i.e. the wrinkles along a seam line), it was found that, while the logarithm of each of these four parameters has a strong linear relationship with the visually perceived degree of wrinkles, following the Web-Fetchner Law, the effective disparity curvature ( D$\_$ce/) and the frequency component of the disparity curvature (D$\_$cf/) appeared to have stronger relationships with the visual perception. This finding is in agreement with the suggestion by Rogers '||'&'||' Cagenello that human visual system may compute the disparity curvature in discriminating curved surfaces. It also suggested an objective method of measuring the degree of surface wrinkles.

  • PDF

Analysis of Surge Current Path of Flyback Converter by Lightning Surge (뇌서지에 의한 플라이백 컨버터의 서지전류 경로 분석)

  • Park, Jun-Woo;Lee, Kang-Hee;Kim, Jin-Ho;Hong, Sung-Soo;Won, Jae-Sun;Kim, Jong-Hae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.178-183
    • /
    • 2013
  • The study of lightning surge have been conducted on information and communications equipment and power system. However, the research on SMPS itself is an inactive field. This paper analyzes surge current path of flyback converter with the combination wave generator by lightning surge. Also, this paper discloses that there exists the surge current with high-frequency component besides the low-frequency component based on the standard surge current. This high-frequency surge current is the major reason to damage the semiconductor devices such as FET and IC. To confirm the validity of the proposed issue, the analysis and experimental results are presented.

A Study on the Reduction of Discrete Frequency Tones of a Cross-Flow Fan of Air-Conditioners -Studies on the Random Distribution of Fan Blades and the Skewed Stabilizers- (에어컨 용 횡단류 홴의 특정 주파수 소음 성분의 저감 대책에 관한 연구 -날개의 랜덤 배열과 경사진 스태빌라이저에 대한 연구-)

  • 구형모
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.870-878
    • /
    • 1998
  • The cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll casing is widely used in many air-ventilating and air-conditioning devices. Its ooperating points of high efficiency and loading conditions frequently induce a annoying sharp tonal component of discrete frequency on the noise spectrum, which is open called as a BPF(Blade-Passing-Frequency) noise and degrades the sound quality of the devices. this BPF tone has been one of the defects of the cross-flow fan. This study proposes two methods in order to reduce this tonal noise component, which are the random distributions of the fan blades and the skewed shapes of the stabilizer. The proposed methods are verified by a simple analytical model and are applied in manufacturing the cross-flow fan and the stabilizer samples. Some experiments are carried out to verify the reduction capability of BPF tones of above two schemes and the experimental results are analyzed. The comparison between two method is also carried out.

  • PDF

A Switching Method for Minimizing the Over Current in Transient Response of 3-phase Interleaved Bidirectional DC-DC Converter with Frequency Modulation (주파수 변조 방식 3상 인터리브드 양방향 DC-DC 컨버터의 과도상태 과전류를 최소화하기 위한 스위칭 기법)

  • Bae, Jongwoo;Jeong, Hyesoo;Jung, Jae-Hun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.530-537
    • /
    • 2016
  • This work deals with a switching method for minimizing overcurrent in a three-phase interleaved bidirectional DC-DC converter with frequency modulation. Generally, a three-phase interleaved DC-DC converter is used to reduce a current ripple component. The combined operation of three-phase and two-phase converters can significantly reduce the ripple component. However, the conventional PWM method cannot solve severe overcurrent during phase transfer or frequency variation for power control. To overcome this problem, this work proposes a new PWM switching method. A 3 kW DC-DC power converter is designed and implemented, and the converter is operated in discontinuous current mode with varying switching frequencies for power control. Simulation and experimental results show the validity of the proposed switching method. The proposed switching method can be widely used in the field of current ripple reduction for three-phase interleaved bidirectional DC-DC converters.

High Frequency Signal Analysis of LOx Pump for Liquid Rocket Engine under Cavitating Condition (캐비테이션 환경에서의 액체로켓엔진용 산화제펌프의 고주파 신호 분석)

  • Kim, Dae-Jin;Kang, Byung Yun;Choi, Chang-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1093-1098
    • /
    • 2017
  • High frequency signals are analyzed which are measured at the inlet / outlet pipeline and pump casing during cavitation tests of the LOx pump for the liquid rocket engine. RMS values of data are shown according to the cavitation number. RMS values of the synchronous frequency, its harmonic frequencies and frequencies of cavitation instabilities are also calculated. The pressure pulsations of the inlet and outlet pipeline are affected by cavitation instabilities. 3x component is predominant in the outlet pulsation sensor since 3x component generated at the inducer is amplified at the impeller. The cavitation instability is also found at the accelerometer signal of the casing.

  • PDF