• Title/Summary/Keyword: Frequency and Energy

Search Result 4,532, Processing Time 0.036 seconds

A Comparative Study on the Characteristics of Thermoacoustic Laser for Using Solar Energy (태양에너지 이용을 위한 열음향 레이저의 특성 비교 연구)

  • Park, Sung-Seek;An, Eoung-Jin;Oh, Seung-Jin;Chun, Won-Gee;Kim, Nam-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.516-521
    • /
    • 2012
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level (SPL), frequency, onset time and the temperature gradient across the stack. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. For a resonance tube of 100mm, no acoustic waves were generated with a power input of 25W. By increasing its length to 200mm, however, maximum SPLs of 96.4 dB, 106.3 dB and 112.8 dB were detected for the tubes of 10mm, 20mm and 30mm in IDs and their respective stack positions of 70mm, 60mm and 50mm from the closed end.

  • PDF

A simple formula for insertion loss prediction of large acoustical enclosures using statistical energy analysis method

  • Kim, Hyun-Sil;Kim, Jae-Seung;Lee, Seong-Hyun;Seo, Yun-Ho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.4
    • /
    • pp.894-903
    • /
    • 2014
  • Insertion loss prediction of large acoustical enclosures using Statistical Energy Analysis (SEA) method is presented. The SEA model consists of three elements: sound field inside the enclosure, vibration energy of the enclosure panel, and sound field outside the enclosure. It is assumed that the space surrounding the enclosure is sufficiently large so that there is no energy flow from the outside to the wall panel or to air cavity inside the enclosure. The comparison of the predicted insertion loss to the measured data for typical large acoustical enclosures shows good agreements. It is found that if the critical frequency of the wall panel falls above the frequency region of interest, insertion loss is dominated by the sound transmission loss of the wall panel and averaged sound absorption coefficient inside the enclosure. However, if the critical frequency of the wall panel falls into the frequency region of interest, acoustic power from the sound radiation by the wall panel must be added to the acoustic power from transmission through the panel.

Origin of the Initial Permeabiliy of Ni0.8-xZn0.2CoxFe2O4+δ Ferrite (Ni0.8-xZn0.2CoxFe2O4+δ조성 페라이트의 투자율 변화 기구)

  • 안용운;김종령;오영우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.1
    • /
    • pp.46-51
    • /
    • 2004
  • The cause for the variation of the initial permeability according to the Co substitution of Ni-Zn ferrite used in the LC resonance filter for the power line communication is studied. The initial permeability decreases as the quantity of Co diminishes, and the saturation magnetization increases as the quantity increases. Because the sintering density and the microstructure of ferrite show little change, the variation of the initial permeability can't be explained by the density, microstructure nor the saturation magnetization factor. The magnetocrystalline anisotropy increases, similar with the saturation magnetization, as the quantity of Co increases. The increase of magnetocrystalline anisotropy value makes the domain wall energy grow, which leads to the decrease of the initial permeability, because there's linear law between the magnetocrystalline anisotropy and the domain wall energy. The resonance frequency to Co substitution moved to high frequency band, due to the close relationship with domain wall energy, Initial permeability decreaed a little with an increase of Co contents, but resonace frequency moved to high frequency band. as a result of that, when Co was added 0.05 mol, initial permeability and resonace frequency was 75 and 25 MHz respectively.

Speech/Music Discrimination Using Mel-Cepstrum Modulation Energy (멜 켑스트럼 모듈레이션 에너지를 이용한 음성/음악 판별)

  • Kim, Bong-Wan;Choi, Dea-Lim;Lee, Yong-Ju
    • MALSORI
    • /
    • no.64
    • /
    • pp.89-103
    • /
    • 2007
  • In this paper, we introduce mel-cepstrum modulation energy (MCME) for a feature to discriminate speech and music data. MCME is a mel-cepstrum domain extension of modulation energy (ME). MCME is extracted on the time trajectory of Mel-frequency cepstral coefficients, while ME is based on the spectrum. As cepstral coefficients are mutually uncorrelated, we expect the MCME to perform better than the ME. To find out the best modulation frequency for MCME, we perform experiments with 4 Hz to 20 Hz modulation frequency. To show effectiveness of the proposed feature, MCME, we compare the discrimination accuracy with the results obtained from the ME and the cepstral flux.

  • PDF

Experimental Evaluation of Percussion Performance for Rock-Drill Drifter

  • Seo, Jaho;Park, Jin-Sun;Kim, Heungsub;Noh, Dae Kyung
    • Journal of Biosystems Engineering
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Purpose: The objective of this study was to understand the operating mechanism of the rock-drill drifter, to explain how to setup an experimental test system and measure the strain of the drifter's rod, and to evaluate the drifter's performance with respect to the impact energy and blow frequency. Methods: The structure of the rock-drill drifter and its operating principle regarding the impact process were analyzed. Static calibration was carried out to calculate the correction factor using a drifter rod as the first step of the experimental test. The impact energy and blow frequency were then calculated based on strain measurements of the drifter's rod. Results: Experimental results showed that the tested drifter elicited a blow frequency of 3330 BPM (Blows Per Minute) and generated impact energy of 170 J/blow. This indicates that the drifter elicits a higher percussion speed and results in a lower impact energy compared to the hydraulic breaker at the same input power. Conclusions: The study proposed methodologies that deal with the experimental setup and the evaluation of the performance of the rock-drill drifter. These methodologies can be extensively used for validating and improving the percussion performance of the drilling equipment.

Low Frequency Roll Motion of a Semi-Submersible Moored in Irregular Waves

  • Hong, Yong-Pyo;Choi, Yong-Ho;Lee, Dong-Yeon;Lee, Wang-Keun
    • Journal of Ship and Ocean Technology
    • /
    • v.11 no.3
    • /
    • pp.1-13
    • /
    • 2007
  • A semi-submersible drilling rig is regarded as one of the typical offshore structures operated in the field with moderate environments such as the Gulf of Mexico, Brazil, and West Africa. Its typical roll and pitch natural periods are around 30 seconds, which avoids prevailing regions of the wave energy spectrum, and their responses in waves are quite acceptable for common operation conditions. But large roll and pitch motions can be induced by wave difference frequency energy spectrum if the metacentric heights of a semi-submersible decrease to small values in some loading conditions, and it is because the roll and pitch natural periods increase and approach to the region where the spectral density of the low frequency wave drift moment has significant value. This paper describes the low frequency roll motion of a semi-submersible that are excited by the wave 2nd order difference frequency energy by a series of model experiments. From the model tests with several different initial metacentric heights (GM), it was observed that a semi-submersible can experience large roll motion due to the wave group spectrum.

Inertial Control of a DFIG-based Wind Power Plant using the Maximum Rate of Change of Frequency and the Frequency Deviation

  • Lee, Hyewon;Kim, Jinho;Hur, Don;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.496-503
    • /
    • 2015
  • In order to let a wind generator (WG) support the frequency control of a power system, a conventional inertial control algorithm using the rate of change of frequency (ROCOF) and frequency deviation loops was suggested. The ROCOF loop is prevailing at the initial stage of the disturbance, but the contribution becomes smaller as time goes on. Moreover, its contribution becomes negative after the frequency rebound. This paper proposes an inertial control algorithm of a wind power plant (WPP) using the maximum ROCOF and frequency deviation loops. The proposed algorithm replaces the ROCOF loop in the conventional inertial control algorithm with the maximum ROCOF loop to retain the maximum value of the ROCOF and eliminate the negative effect after the frequency rebound. The algorithm releases more kinetic energy both before and after the frequency rebound and increases the frequency nadir more than the conventional ROCOF and frequency loops. The performance of the algorithm was investigated under various wind conditions in a model system, which includes a doubly-fed induction generator-based WPP using an EMTP-RV simulator. The results indicate that the algorithm can improve the frequency drop for a disturbance by releasing more kinetic energy.

Operation of Battery Energy Storage System for Governor Free and its Effect (주파수추종 운전 적용을 위한 BESS의 운용 방법 및 효과)

  • Cho, Sung-Min;Jang, Byung-Hoon;Yoon, Yong-Bum;Jeon, Woong-Jae;Kim, Chulwoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.16-22
    • /
    • 2015
  • As the development of Battery Energy Storage System(BESS) and the increasing of intermittent energy sources like wind power and photovoltaic, the application of BESS in load frequency control is considered as an effective method. To evaluate the effectiveness of BESS application in frequency control, we defined a governor free model of BESS to conduct dynamic simulation. Using the BESS dynamic model, we implemented the power system dynamic model including steam, gas and hydro turbine generators. In this paper we study the control performance of BESS in primary frequency control. The effect of BESS speed regulation rate and response time on governor free operation is investigated. In addition, we compared BESS from steam turbine generator in view point of frequency regulation.

Study on Impact of Wind Power in Grid Frequency Quality of Stand-alone Microgrid (독립형 마이크로그리드내 풍력발전출력이 주파수 품질에 미치는 영향 분석)

  • Huh, Jae-Sun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.79-85
    • /
    • 2016
  • This paper analyzed the influence of wind power fluctuations in grid frequency of a stand-alone microgrid that is hybrid generation system with diesel generator, wind turbine, and Battery Energy Storage System (BESS). The existing island area power system consists of only diesel generators. So the grid frequency can be controllable from load change. But hybrid generation system with Renewable Energy Sources (RES) such as wind energy that has the intermittent output can bring power quality problems. BESS is one of the ways to improve the intermittent output of the RES. In this paper, we analyzed the role of BESS in a stand-alone microgrid. We designed a modelling of wind power system with squirrel-cage induction generator, diesel power system with synchronous generator, and BESS using transient analysis program PSCAD/EMTDC. And we analyzed the variation of the grid frequency according to the output of BESS.

High Frequency Circuit Design using Feedback Control with Body Load Fluctuation for Pain Relief Therapy (통증 완화 치료기용 인체 부하 변동에 따른 피드백 제어가 가능한 고주파 회로 설계)

  • Park, Chul-Won;Won, Chul-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.45-49
    • /
    • 2013
  • High frequency system has been used for the purpose of skin care and obesity treatment, by high-frequency energy is applied to the human body generates deep heat. Conventional high frequency system could not selection control by depending on the body load fluctuations. Such as burns and side effects have been reported by system instability and then therapeutic effect is insufficient. During treatment, objective information about the status of the patient was no. Because of treatment methods are subjective, and so tailored treatments were impossible. In this paper, high frequency medical system with sinusoidal frequency characteristics without distortion of the Push pull switching scheme for pain relief therapy was designed. And control circuit that was designed by feedback using the output changes according to the body-load fluctuation. Last, power circuit for efficient control the heat generated from the hardware was proposed.