• Title/Summary/Keyword: Frequency analyzer

Search Result 616, Processing Time 0.03 seconds

Method for High Frequency Modeling of Transformers Using the S-Parameter (S-Parameter를 이용한 변압기의 고주파 모델링 기법)

  • Jung, Hyeonjong;Yoon, Seok;Kim, Yuseon;Bae, Seok;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.9
    • /
    • pp.677-684
    • /
    • 2018
  • In this paper, we propose a method for high-frequency modeling of transformers using the S-parameter. The open and short circuits of the primary and secondary sides were configured, and the reflection coefficient in each circuit was measured using a vector network analyzer. The equivalent circuit elements were extracted from the measured results to model the high-frequency equivalent circuit, and the validity of the method was verified by comparing the measured S-parameters in a 2-port network with the simulation results.

A study on the stability criterion of the control systems for the drive systems in rolling mill plants (압연구동제어계(壓延驅動制御系)의 안정도(安定度) 판정법(判定法)에 관한 연구)

  • Jeong, H.S.;Baek, K.N.;Kang, M.J.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.380-382
    • /
    • 1989
  • It is necessary for us to maintain good the quality of products in iron and steel making process, especially in the rolling mill plants. Thus, we need check the stability criteria of control systems. In the frequency domain, the whole system including controllers can be identified using FFT analyzer. But this method is not adequete where precise identification is demanded. Thus a way to complement the defects In the frequency domain analysis using FFT analyzer is introduced. And In the time domain, to establish the stability criteria on the control systems, the assumed parameters obtained using least square method are presented in this report.

  • PDF

Case Study on the Fault Discrimination of Pole Transformer using Frequency Response Analyzer (주파수 응답 분석기를 이용한 주상변압기 상태진단 사례)

  • Kang, Moon-Ho;Pi, Jae-Hwan;Jin, Seung-Hwan;Lee, Kang-Se
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1490-1491
    • /
    • 2015
  • 주파수 응답 분석기(Frequency Response Analyzer, FRA)는 수십 MHz 고주파수 범위까지 기기의 전달함수를 측정하여 변압기, 리액터 등과 같은 권선형 기기 내 기계적, 기하학적 변형을 진단하는 장치이다. 배전선로에 운영 중인 권선형 기기인 주상변압기는 현재 193만대(2015. 4 기준)가 현장에 설치되어 운전 중에 있다. 그러나 변압기의 상태진단은 권선저항 측정, 전압비 측정 등 기초적인 단계에 있으며 일부 PD 분석기법이 연구 중에 있다. 본 논문에서는 권선형 기기의 진단에 기 활용하고 있는 주파수 응답 분석기(FRA)의 측정원리를 바탕으로 주상 변압기에 적용하여 적용 가능성을 검토하였다.

  • PDF

토양오염도 측정을 위한 Frequency Domain Reflectometry with Vector Network Analyzer(FDR-V) system 적용성 평가

  • Kim Man-Il;Kim Hyeong-Su;Jeong Gyo-Cheol
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.36-41
    • /
    • 2005
  • 복소유전율상수인 실수부(Real part)와 허수부(Imaginary part)를 측정하기 위하여 Frequency Domain Reflectometry with Vector Network Analyzer(FDR-V) 측정 장비로 $1{\sim}18GHz$ 범위 내에서 매질의 기본 구성단위인 공기, 물, 흙입자에 대한 기본적인 유전율 특성을 파악하고, 이들로부터 다공질 매질내 유류 오염물질의 함유 특성을 측정할 수 있다. 또한 제작된 시료에 대한 포화도와 1GHz 범위에 분포하는 실수부 유전율상수와의 관계로부터 매질의 공극내 함유된 물질의 유전율상수 특성에 매우 민감한 반응을 보이므로, 이들로부터 매질의 공극률 내지 유효공극률의 측정이 가능할 것으로 사료된다.

  • PDF

A Suggestion of Method to Remove Bias Error of the FRF Obtained by FFT Analyzer - Application of TFS - (계측기에서 얻어진 주파수 응답 함수의 오차 제거 방안 - 전달함수 합성법에의 응용 -)

  • 김승엽;정의봉;서영수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.408-413
    • /
    • 2003
  • The frequency response function(FRF) of each substructure is used for the transfer function synthesis method(TFS). The dynamic characteristics of the full system are obtained by synthesizing FRFs of each substructure. The validation of TFS depends on accuracy for FRF of each substructure. Impact hammer testing Is widely used to obtain the modal characteristics of structures However. the FRF obtained from impact hammer testing contains bias errors, such as finite record length error and leakage error of which characteristic depends on data acquisition time which we call record length. In this paper, a method to remove hose errors is proposed so as to enhance results of TFS. Numerical and experimental examples show that the FRF of full structure can be predicted nearly exactly by the method proposed in this paper.

  • PDF

Effect of Rare Earth (Gd, Er) on the Permeabilities of Ba-Ferrite (회토류(Gd, Er)첨가가 Ba 페라이트의 투자율에 미치는 영향)

  • 정승우;김태원;최우성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.887-894
    • /
    • 2000
  • In this paper, we have studied the effect of earth (Gd, Er) on the various properties (microstructure, shrinkage, initial permeability, permeability as a function of frequency, etc) of Ba-ferrite. The permeabilities were analyzed by Impedance Analyzer(100KHz~40MHz) and Network Analyzer(30KHz~3㎓). As the result of XRD, all of the Ba-ferrite doped with rat earth was found to be Y-hexagonal phase. The resonance frequencies at the maximum imaginary value of complex permeability were observed near 2㎓. The complex permeabilities of the Ba-ferrite doped with Gd$_2$O$_3$at 3wt% and doped with Er$_2$O$_3$at 3wt% and 5wt% as a function of frequency showed the highest value at sintered temperature at 95$0^{\circ}C$/3h.

  • PDF

A Study on Development of One-channel Gas Sensor Using Polymeric Sensitive LB Films (고분자 감웅성 LB막을 이용한 One-channel 가스센서의 개발연구)

  • Kang, H.W.;Kim, J.M.;Kwon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.261-263
    • /
    • 1996
  • The study on the development of one-channel gas sensor using the quartz crystal analyzer were attempted. The adsorption and desorption behavior of organic gases were investigated using the resonant frequency and resistance method of quartz crystal. The sensitive materials were deposited on the quartz crystal analyzer(QCA) by using Langmuir-Blodgett method. To investigate the response characteristics of organic vapours and response mechanism, resonant frequency-resonant resistance (F-R) diagram was used. In our experimental results, the response mechanism between sensitive LB film and organic vapours was obtained using F-R diagram. And the position of each organic vapour were different as to the kind and injection amount. Thus F-R diagram can be applied to one-channel gas sensor using the QCA and useful to analyze the response mechanism between organic vspours and sensitive LB films.

  • PDF

Transmitter Identification Signal Analyzer (송신기 식별 신호분석기)

  • Park, Sung-Ik;Lee, Jae-Young;Kim, Heung-Mook;Oh, Wang-Rok
    • Journal of Broadcast Engineering
    • /
    • v.13 no.3
    • /
    • pp.350-364
    • /
    • 2008
  • Single frequency network (SFN) design based on the Advanced Television Systems Committee (ATSC) specification, a terrestrial digital television (DTV) system, normally causes a interference problem, among signals from multiple transmitters or repeaters. To solve this, the ATSC recommended practice (RP) introduces a transmitter identification (TxID) signal embedded in a signal from each transmitter or repeater. A TxID signal analyzer is then used to detect the TxID signal, and following the analysis results, a SFN design can be adjusted. This paper discusses the generation and usages of Kasami sequence, is used the TxID signal. The configuration of the TxID signal analyzer to efficiently detect TxID signal is proposed and the results of theoretical performance analysis are provided. Moreover, computer simulation and laboratory test results are provided to evaluate the performance of TxID signal analyzer and the theoretical performance analysis.

Implementation of morphologica analyzer and spelling corrector for charcter recognition post-processing (문자 인식 후처리를 위한 형태소 분석기와 문자 교정기의 구현)

  • 이영화;김규성;김영훈;이상조
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.5
    • /
    • pp.82-92
    • /
    • 1997
  • In this paper, we propose post-rpocessing method that corrects a misrecognized character by generated a characater recognizer using morphological analyzer and spelling corrector. The proposed post-processing consists of sthree phases : First, our method pass through morhological analyzer which only outputted necessary information for spelling correcting, doesn't analyze a bundle of phrases, and detects the location of misrecognized character. Second, tagging the generated candidate character using the information of character substitution table and grapheme substitution/separating table. Then we retry analysis after the misrecognition character has been substituted. Finally we select table, we investigate misrecognized charcters in CORPUS. Reliability analysis used to frequency of randomly selected about 100,000 words in CORPUS. A korean character recognizer demonstrates 93% correction rate without a post-processing. The entire recognition rate of our system with a post-processing exceeds 97% correction rate.

  • PDF

Development of Bioelectric Impedance Measurement System Using Multi-Frequency Applying Method

  • Kim, J.H.;Jang, W.Y.;Kim, S.S.;Son, J.M.;Park, G.C.;Kim, Y.J.;Jeon, G.R.
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.368-376
    • /
    • 2014
  • In order to measure the segmental impedance of the body, a bioelectrical impedance measurement system (BIMS) using multi-frequency applying method and two-electrode method was implemented in this study. The BIMS was composed of constant current source, automatic gain control, and multi-frequency generation units. Three experiments were performed using the BIMS and a commercial impedance analyzer (CIA). First, in order to evaluate the performance of the BIMS, four RC circuits connected with a resistor and capacitor in serial and/or parallel were composed. Bioelectrical impedance (BI) was measured by applying multi-frequencies -5, 10, 50, 100, 150, 200, 300, 400, and 500 KHz - to each circuit. BI values measured by the BIMS were in good agreement with those obtained by the CIA for four RC circuits. Second, after measuring BI at each frequency by applying multi-frequency to the left and right forearm and the popliteal region of the body, BI values measured by the BIMS were compared to those acquired by the CIA. Third, when the distance between electrodes was changed to 1, 3, 5, 7, 9, 11, 13, and 15 cm, BI by the BIMS was also compared to BI from the CIA. In addition, BI of extracellular fluid (ECF) was measured at each frequency ranging from 10 to 500 KHz. BI of intracellular fluid (ICF) was calculated by subtracting BI of ECF measured at 500 kHZ from BI measured at seven frequencies ranging from 50 to 500 KHz. BI of ICF and ECF decreased as the frequency increased. BI of ICF sharply decreased at frequencies above 300 KHz.