• 제목/요약/키워드: Frequency Stabilization

검색결과 275건 처리시간 0.023초

방진을 고려한 항공 정찰용 카메라 모듈부의 진동특성에 관한 연구 (A Study on the Vibration Characteristics of Camera Module for Aerial Reconnaissance Considering Vibration Isolator)

  • 이상은;이태원
    • 한국정밀공학회지
    • /
    • 제29권5호
    • /
    • pp.545-553
    • /
    • 2012
  • A Gimbal structure system in observation reconnaissance aircraft is made up of camera module and stabilization drive device supporting camera module. During flight for image recording, the aircraft undergoes serious accelerations with wide frequencies due to several factors. Though base excitation of stabilization drive device induces vibration of camera module, it must get the stable and clean images. To achieve this aim, acceleration of camera module must be reduced. Hence, vibration isolators were installed to stabilization drive device. Considering isolators and bearings in the stabilization drive device, vibration characteristics of gimbal structure system were analyzed by finite element method. For three translational direction, acceleration transmissibility of camera module was calculated by harmonic responses analysis in the frequency range of 5 ~ 500 Hz. In addition to, sine-sweep experiment were performed to prove correctness of present analysis.

샘플 홀드 회로를 이용한 초퍼 안정화 기법이 적용된 저잡음 증폭기 (LNA with Chopper Stabilization Technique Using Sample and Hold Circuit)

  • 박영민;남민호;조경록
    • 전자공학회논문지
    • /
    • 제53권10호
    • /
    • pp.27-33
    • /
    • 2016
  • 본 논문은 초퍼 안정화기법을 적용한 저잡음 증폭기를 제안한다. 초퍼 안정화기법은 CMOS 증폭기의 저주파수 대역 오프셋과 플리커 잡음을 감소시키는 효과적인 기법이다. 기존의 초퍼 증폭기는 초퍼로 인해 발생되는 초핑 스파이크를 제거하기 위해 Low Pass Filter(LPF)를 사용하기 때문에 저항과 커패시터가 큰 면적을 차지한다는 단점을 가지고 있다. 제안된 초퍼 증폭기는 LPF 대신 샘플 앤 홀드 방식의 초핑 스파이크 제거 회로를 사용하여 적은 전압감쇄에서 36%, 면적에서 11%의 이득을 얻을 수 있다.

A Wide-range Tunable Wavelength-stabilization Technique for Semiconductor Lasers

  • Chen, Han;Qiao, Qinliang;Min, Jing;He, Cong;Zhang, Yuanyuan
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.384-390
    • /
    • 2021
  • This paper presents a wide-range tunable wavelength-locking technology based on optoelectronic oscillation (OEO) loops for optical fiber sensors and microwave photonics applications, explains the theoretical fundamentals of the design, and demonstrates a method for locking the relative wavelength differences between a leader semiconductor laser and its follower lasers. The input of the OEO loop in the proposed scheme (the relative wavelength difference) determines the radio-frequency (RF) signal frequency of the oscillation output, which is quantized into an injection current signal for feedback to control the wavelength drift of follower lasers so that they follow the wavelength change of the leader laser. The results from a 10-hour continuous experiment in a field environment show that the wavelength-locking accuracy reached ±0.38 GHz with an Allan deviation of 6.1 pm over 2 hours, and the wavelength jitter between the leader and follower lasers was suppressed within 0.01 nm, even though the test equipment was not isolated from vibrations and the temperature was not controlled. Moreover, the tunable range of wavelength locking was maintained from 10 to 17 nm for nonideal electrical devices with limited bandwidth.

Reduction of headache intensity and frequency with maxillary stabilization splint therapy in patients with temporomandibular disorders-headache comorbidity: a systematic review and meta-analysis

  • Manrriquez, Salvador L.;Robles, Kenny;Pareek, Kam;Besharati, Alireza;Enciso, Reyes
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제21권3호
    • /
    • pp.183-205
    • /
    • 2021
  • This systematic review and meta-analysis aimed to analyze the effectiveness of maxillary stabilization splint (SS) therapy to reduce headache (HA) intensity and HA frequency in patients with temporomandibular disorders (TMD)-HA comorbidity. Randomized controlled trials (RCTs) using full-arch coverage, hard resin, and maxillary SS therapy were included. Electronic databases, including Cochrane Library, MEDLINE through PubMed, Web of Science, and EMBASE, were searched. The risk of bias was analyzed based on Cochrane's handbook. The search yielded 247 references up to January 28, 2020. Nine RCTs were included at a high risk of bias. The comparison groups included other splints, counseling, jaw exercises, medications, neurologic treatment, and occlusal equilibration. Four studies reported a statistically significant reduction in HA intensity, and five studies reported significant improvement in HA frequency from baseline at 2-12 months in patients with TMD-HA comorbidity treated with a full-arch hard maxillary SS. HA frequency in tension-type HA (TTH) comorbid with TMD diagnoses of myofascial pain (MFP) or capsulitis/synovitis improved significantly with SS than that with full-arch maxillary non-occluding splint (NOS) in two studies. Comparison groups receiving hard partial-arch maxillary splint nociceptive trigeminal inhibition (NTI) showed statistically significant improvements in HA intensity in patients with mixed TMD phenotypes of MFP and disc displacement comorbid with "general HA." Comparison groups receiving partial-arch maxillary resilient/soft splint (Relax) showed significant improvements in both HA intensity and frequency in patients with HA concomitant with MFP. The meta-analysis showed no statistically significant difference in the improvement of pain intensity at 2-3 months with comparison of the splints (partial-arch soft [Relax], hard [NTI], and full-arch NOS) or splint use compliance at 6-12 months with comparison of the splints (partial-arch Relax and full-arch NOS) versus the SS groups in patients with various TMD-HA comorbidities. In conclusion, although SS therapy showed a statistically significant decrease in HA intensity and HA frequency when reported, the evidence quality was low due to the high bias risk and small sample size. Therefore, further studies are required.

A natural frequency sensitivity-based stabilization in spectral stochastic finite element method for frequency response analysis

  • Lee, Gil-Yong;Jin, Seung-Seop;Park, Yong-Hwa
    • Structural Engineering and Mechanics
    • /
    • 제75권3호
    • /
    • pp.311-325
    • /
    • 2020
  • In applying the spectral stochastic finite element methods to the frequency response analysis, the conventional methods are known to give unstable and inaccurate results near the natural frequencies. To address this issue, a new sensitivity based stabilized formulation for stochastic frequency response analysis is proposed in this paper. The main difference over the conventional spectral methods is that the polynomials of random variables are applied to both numerator and denominator in approximating the harmonic response solution. In order to reflect the resonance behavior of the structure, the denominator polynomials is constructed by utilizing the natural frequency sensitivity and the random mode superposition. The numerator is approximated by applying a polynomial chaos expansion, and its coefficients are obtained through the Galerkin or the spectral projection method. Through various numerical studies, it is seen that the proposed method improves accuracy, especially in the vicinities of structural natural frequencies compared to conventional spectral methods.

13C2H2 분자를 이용한 반도체 레이저 주파수 안정화 및 그 파장 측정 (Frequency stabilization of laser and absolute wavelength measurement of 13C2H2 for DWDM system)

  • 문한섭;서호성;이인원
    • 한국광학회지
    • /
    • 제13권2호
    • /
    • pp.123-127
    • /
    • 2002
  • 본 연구에서는 1550nm 영역에서 $^{13}$C$_2$H$_2$분자의 회전-진동 모드에 대한 분광을 수행하고, 각 전이선들에 대한 파장을 측정하였다. 파장 측정을 위해서 각 흡수선의 피크에서 레이저주파수 변조를 시켜, 변조신호의 1차 하모닉 록킹법으로 레이저의 주파수를 안정화시키고, 광주파수 표준기로 사용되고 있는 요오드 안정화 헬륨-네온 레이저(KRISS-R70l)로 교정한 파장계를 사용하여 3$\times$$10^{-7}$ 의 정확도로 $^{13}$C$_2$H$_2$의 전이선들의 파장을 측정하였다. 그리고, 아세틸렌 분자 흡수선의 옆선에 주파수 안정화하는 방법을 이용하여 ITU-T 그리드의 절대 파장에 일치하는 표준광원 개발은 제안하였다.

동특성 해석에 기반한 이동용 안테나 김발 안정화 시스템 (Stabilization System for Mobile Antenna Gimbal based on Dynamic Characteristics Analysis)

  • 이기남;이병호;이증;김지억;송재복
    • 대한기계학회논문집A
    • /
    • 제37권7호
    • /
    • pp.851-856
    • /
    • 2013
  • 최근에 들어 전술환경이 모든 요소들을 네트워크로 연결하는 NCW 환경으로 변화하면서 위성을 이용한 대용량 고속의 위성통신이 매우 중요하게 부각되었다. 고품질의 위성링크를 제공하기 위해서는 플랫폼의 안정화 기술이 선행되어야 한다. 기존의 안정화 제어기술은 주로 PI제어기를 사용하는 선박용이 주류를 이루었다. 이에 비해 보다 더 빠른 응답특성이 요구되는 지상용 단말의 경우 빠른 시간 안에 위성을 추적할 수 있도록 안테나 구동속도가 빨라야 하며, 외란을 감지하는 센서와 감지된 외란을 보상하면서 위성지향을 유지할 수 있도록 하는 알고리즘이 필요하다. 본 연구에서는 안테나 시스템의 동역학 특성을 분석하여 지상용 단말에 적합한 저주파 영역에서 높은 격리도를 갖는 $PI^2$ 제어기를 포함하는 안정화 제어루프를 제안한다.

액체 로켓엔진에서 연소 안정화기구의 적용 효과 (Application of Combustion Stabilization Devices to Liquid Rocket Engine)

  • 손채훈;설우석;이수용;김영목;이대성
    • 한국항공우주학회지
    • /
    • 제31권6호
    • /
    • pp.79-87
    • /
    • 2003
  • 로켓엔진에서 발생하는 고주파 연소 불안정(음향 불안정)을 억제하기 위해 엔진에 적용되는, 배플이나 음향공과 같은 연소 안정화기구를 설계하고 그 효과를 시험을 통해 검증하였다. 먼저, 음향 감쇠 관점에서, 선형 감쇠이론을 토대로 연소 안정화기구를 설계하였으며, 주요 설계인자로서 감쇠인자를 고려하여 여러 연소실에서의 감쇠인자를 수치적으로 계산하였따. 다음으로, 다양한 작동조건에서, 음향공이 장착된 무배플 연소실에서의 연소시험이 수행되었다. 이를 통해 무배플 연소실의 안정성 특성, 주요 유해주파수 및 유해 음향모드 등이 파악되었으며, 동적 안정성 여분이 상당히 작음이 확인되었다. 이는, 무배플 연소실의 연소 안정화에 현재 사양의 음향공의 효과가 미흡함을 입증한다. 배플의 효과를 입증하기 위해 배플장착 연소실에서 연소 안정성 평가시험을 수행하였고, 뚜렷한 연소 안정화 현상을 관측할 수 있었다. 이는 현 설계사양의 배플이 충분한 감쇠 효과를 가짐을 입증한다.

NU 1.5MV 반데그라프 가속기 (V) -고전압 안정화 계통의 동작- (SNU 1.5 MV Van de Graaff Accelerator (V) -on the Operation of the High Voltage Stabilization System-)

  • 배영덕;박혜일;정기형;우형주;최병호
    • Nuclear Engineering and Technology
    • /
    • 제19권2호
    • /
    • pp.115-121
    • /
    • 1987
  • SNU 1.5MV 직렬형 반데그라프 가속기의 고전압 안정화 계통을 설치하여 그 동작 특성을 파악하고 최적화하였다. 이온빔 수송계통의 최적 운전 조건을 단계적인 실험을 통하여 결정하였으며 적절한 운전 조건하에 표적함에서 350nA의 가속된 양성자빔을 얻었다. 고전압을 안정화하지 않았을 때의 고전압 변동은 이온빔을 가속하지 않을 때와 가속할 때 각각 $\Delta$V/V=5.2$\times$$10^{-3}$, 7.2$\times$$10^{-3}$이었으며 그 변동 주파수는 3Hz 이하였다. 터미날 전압 247.3kV에서 고전압 안정화 계통의 최적 운전을 통하여 터미날 전압의 변동은 $\Delta$V/V=2.45$\times$$10^{-4}$ 으로 줄었고 에너지 안정도는 $\Delta$E/E=2.44$\times$$10^{-4}$ 으로 유지되었으며 이 때의 안정화 계수는 29.4였다.

  • PDF

K-band 도파관을 이용한 대전력 마이크로파 출력장치 연구 (A Study of High Power Microwave Output by K-band Waveguide)

  • 김원섭
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.588-591
    • /
    • 2009
  • We had experimental studies of microwave output generator. We experimented with a corrugate-shped K-band slow wave guide in the backward wave oscillator. It generated output 표 interaction between electron beam's generation and magnetic field. We estimated oscillation frequency at 24GHz by changing propagation velocity and group velocity. We identified movement by second harmonic of Cherencov interaction and slow cyclotron mode. In our study we achieved oscillation stabilization, generation of long pulse, improvement of oscillation efficiency and output.