• Title/Summary/Keyword: Frequency Shift

Search Result 1,218, Processing Time 0.025 seconds

A Hybrid PWM-Resonant DC-DC Converter for Electric Vehicle Battery Charger Applications

  • Lee, Il-Oun
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1158-1167
    • /
    • 2015
  • In this paper, a new hybrid DC-DC converter is proposed for electric vehicle 3.3 kW on-board battery charger applications, which can be modulated in a phase-shift manner under a fixed frequency or frequency variation. By integrating a half-bridge (HB) LLC series resonant converter (SRC) into the conventional phase-shift full-bridge (PSFB) converter with a full-bridge rectifier, the proposed converter has many advantages such as a full soft-switching range without duty-cycle loss, zero-current-switching operation of the rectifier diodes, minimized circulating current, reduced filter inductor size, and better utilization of transformers than other hybrid dc-dc converters. The feasibility of the proposed converter has been verified by experimental results under an output voltage range of 250-420V dc at 3.3 kW.

Analysis of Field Noise from High Speed Train Using Dedopplerization (도플러 보정을 통한 고속열차 현장 측정 소음 분석)

  • Lee, Yong Woo;Lee, Duck Joo;Kwon, Hyeok Bin;Yun, Su Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.431-437
    • /
    • 2013
  • Measured acoustic signal from operating high speed train contains frequency change called doppler shift due to its motion. To avoid this doppler shift wind tunnel test is required. But scaledown of model can cause change of source characteristics. And measurements using some part of train cannot reproduce real flow condition. The best way to recognize real noise source characteristics is measurement from operating high speed train but doppler shift makes it hard. So, we developed simple dedopplerization technique for one microphone and applied to field test data of high speed train. Through this, we could capture real frequency of noise from operating high speed train.

Single Phase-Shift Modulation with Variable-Frequency to Reduce Conduction Losses of DAB Converters (DAB 컨버터의 전도 손실 저감을 위한 가변 주파수의 단일 위상 시프트 변조기법)

  • Dao, Ngoc Dat;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.124-125
    • /
    • 2019
  • This paper proposes a novel control method to minimize conduction losses of dual active bridge (DAB) converters for on-board chargers of electric vehicles (EVs). In the control method, two variables are regulated, which are the phase-shift angle between the primary and secondary full bridges and the switching frequency. From time-domain analysis, an optimal phase-shift angle is derived to achieve the minimum RMS value of the transformer current. The proposed method was implemented for a 3.6-kW SiC-based prototype to validate its effectiveness. A high efficiency over 97.3% has been achieved for a wide output voltage range.

  • PDF

A Study on Phase Shift of Driving Signal in order to Output Control of Inverter for High Frequency Induction Heating (고주파 유도가열용 인버터의 출력제어를 위한 구동신호의 위상 천이에 관한 연구)

  • Lee Bong-Seob;Choi Shin-Hyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.580-586
    • /
    • 2006
  • This paper proposes high frequency inverter for induction heating and discusses output control of high frequency inverter. Output control method of inverter is controlled by phase shift of switching devices applied to driving signal and the principle and a characteristic estimates of proposed circuit described on normal parameters. Also output characteristics for circuit design presented to numeric analysis and experimental equipment is made to compare theoretical result with an experimental result and an established characteristic estimate.

  • PDF

The Study of Gas Sensor Using Rheological Properties of Polymeric Sensitive LB Films (고분자감응성 LB막의 유변학적인 특성을 이용한 가스센서 연구)

  • 강현욱;김정명;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.198-201
    • /
    • 1997
  • The new system for identification of organic vapours and analysis method of mechanism between organic vapours and sensitive materials were attempted using the resonant resistance and resonant frequency of Quartz Crystal Analyzer (Q. C. A.). The resonant resistance shift means rheological changes in sensitive LB films occurred by the adsorption of organic vapours, while the resonant frequency shift represent the mass of organic vapour loaded in or on the sensitive LB films. It is thought that we can obtain more accurate response mechanism of organic vapour using the resonant frequency and resonant resistance diagram. The polymeric sensitive material were quantitively depositied using the LB method. In the experimental results, the adsorption behavior of organic vapour response can be decided by two type ; surface adsorption and penetration into sensitive material. Organic vapours had different positions in the Frequency-Resistance (F-R) diagram as to the kinds and concentrations of organic vapours. Thus F-R diagram can be applied to the development of one channel gas sensing system using the Quartz Crystal Analyzer.

  • PDF

Resonance Frequency and Quality Factor Tuning in Electrostatic Actuation of Nanoelectromechanical Systems

  • Kim, Dong-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.9
    • /
    • pp.1711-1719
    • /
    • 2005
  • In an electro statically actuated nanoelectromechanical system (NEMS) resonator, it is shown that both the resonance frequency and the resonance quality (Q) factor can be manipulated. How much the frequency and quality factor can be tuned by excitation voltage and resistance on a doubly-clamped beam resonator is addressed. A mathematical model for investigating the tuning effects is presented. All results are shown based on the feasible dimension of the nanoresonator and appropriate external driving voltage, yielding up to 20 MHz resonance frequency. Such parameter tuning could prove to be a very convenient scheme to actively control the response of NEMS for a variety of applications.

Performance of M-ary Turbo Coded Synchronous FHSS Multiple Access Networks with Noncoherent MFSK under Rayleigh Fading Channels

  • Hong, Sungnam;Cheun, Kyungwhoon;Lim, Hyuntack;Cho, Sunghye
    • Journal of Communications and Networks
    • /
    • v.15 no.6
    • /
    • pp.601-605
    • /
    • 2013
  • The performance of M-ary turbo coded synchronous, fast frequency-hopping spread spectrum multiple-access (FHSS-MA) networks with M-ary frequency shift keying (MFSK) and noncoherent detection is analyzed under Rayleigh fading. Results indicate that M-ary turbo codes dramatically enhance the performance of FHSS-MA networks using MFSK compared to binary turbo codes.

The relationships between dietary behavior and health related factors according to shift work in nurses (간호사들의 교대근무가 식행동 및 건강관련요인에 미치는 영향)

  • Kim, Ji-Myung;Kang, Bok-Hee
    • Journal of Nutrition and Health
    • /
    • v.47 no.6
    • /
    • pp.416-425
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the stress, dietary habits, dietary behaviors, and health-related behavior of nurses. Method: The subjects of this study were 161 nurses studying at a cyber university. The general characteristics, stress, dietary habits, dietary behaviors, and health-related behavior of the subjects were surveyed using a self-administered questionnaire in October, 2010. The subjects were divided into two groups according to the working pattern: shift workers (n = 110) and non-shift workers (n = 51). Results: In the general characteristics, there were significant differences in marriage, monthly income, employment type, and job satisfaction between the two groups. Total stress score did not differ significantly between the two groups. In dietary habits, significant differences in meal regularity, skipping meals, skipping reasons, having regular mealtimes, frequency of snack and the snack time between shift workers and non-shift workers (p<0.05). Total score of dietary behaviors in shift workers was significantly lower than that in non-shift workers (p<0.05). Score of shift workers in taking three meals per day regularly was significantly lower than that of non-shift workers. In health-related behavior, a significant difference in sleeping time was observed between shift workers and non-shift workers. Dietary behavior showed negative correlation with shift work (r = 0.176) and positive correlation with health consciousness (r = 0.210) and perceived health status (r = 0.198) in subjects after adjustment for age, marriage, monthly income, and employment type (p < 0.05). Multiple regression analysis revealed that shift work, health consciousness, and perceived health status affected dietary behavior in subjects. Conclusion: These results indicate that shift working nurses had poor dietary habits and dietary behaviors, and these dietary behaviors are affected by their shift work, health consciousness, and perceive health status.

Design of VCO for WLAN using Phase Shift (Phase Shift를 이용한 WLAN용 VCO의 설계)

  • 박영호;강태영;추성중;박정호
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.617-620
    • /
    • 2003
  • In this paper, a monolithic VCO has been designed for Wireless Local Area Network(WLAN) applications. The differential form VCO is constructed using positive feedback with capacitor and phase shift for low phase noise performance. The VCO shows the phase noise of -92.725 dBc/Hz at an offset frequency of 10KHz and the tunning range of 5.822~6.154GHz.

  • PDF

Study of the Surface Acoustic Wave Biosensors for Detection of the Immunoglobulin G (자가면역글로불린 G 측정을 위한 표면탄성파 바이오센서에 대한 연구)

  • Kim, Gi-Beum;Cheong, Woo-Suk;Park, Young-Ran;Kim, Shang-Jin;Kim, Seong-Jong;Kang, Hyung-Sub;Kim, Jin-Shang;Hong, Chul-Un
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.224-229
    • /
    • 2011
  • In this study, we have developed shear horizontal(SH) surface acoustic wave(SAW) sensors for the detection of immunoglobulin G(IgG) on the gold coated delay line of SH-SAW devices. As the result of the experiment, we could uniformly immobilize anti-MIgG(mouse IgG) conjugate on the surface of gold. When displaying results of immobilization on the surface of gold using G-anti MIgG conjugate and blocking buffer in frequency shift, G-anti MIgG conjugate showed frequency shift of 75.1 kHz in the initial frequency, and blocking buffer showed frequency shift of 215.7 kHz. When various concentrations of MIgG was added in 100MHz type sensor, the sensor showed 46.3, 127.45, 161.21 and 262.39 kHz frequency shift at 25, 50, 75 and 100 ${\mu}g$ MIgG concentration, respectively.