• Title/Summary/Keyword: Frequency Response Method

Search Result 2,153, Processing Time 0.029 seconds

GEOTECHNICAL DESIGNS OF THE SHIP IMPACT PROTECTION SYSTEM FOR INCHEON BRIDGE

  • Choi, Sung-Min;Oh, Seung-Tak;Park, Sang-Il;Kim, Sung-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.72-77
    • /
    • 2010
  • The Incheon Bridge, which was opened to the traffic in October 2009, is an 18.4 km long sea-crossing bridge connecting the Incheon International Airport with the expressway networks around the Seoul metropolitan area by way of Songdo District of Incheon City. This bridge is an integration of several special featured bridges and the major part of the bridge consists of cable-stayed spans. This marine cable-stayed bridge has a main span of 800 m wide to cross the vessel navigation channel in and out of the Incheon Port. In waterways where ship collision is anticipated, bridges shall be designed to resist ship impact forces, and/or, adequately protected by ship impact protection (SIP) systems. For the Incheon Bridge, large diameter circular dolphins as SIP were made at 44 locations of the both side of the main span around the piers of the cable-stayed bridge span. This world's largest dolphin-type SIP system protects the bridge against the collision with 100,000 DWT tanker navigating the channel with speed of 10 knots. Diameter of the dolphin is up to 25 m. Vessel collision risk was assessed by probability based analysis with AASHTO Method-II. The annual frequency of bridge collapse through the risk analysis for 71,370 cases of the impact scenario was less than $0.5{\times}10^{-4}$ and satisfies design requirements. The dolphin is the circular sheet pile structure filled with crushed rock and closed at the top with a robust concrete cap. The structural design was performed with numerical analyses of which constitutional model was verified by the physical model experiment using the geo-centrifugal testing equipment. 3D non-linear finite element models were used to analyze the structural response and energy-dissipating capability of dolphins which were deeply embedded in the seabed. The dolphin structure secures external stability and internal stability for ordinary loads such as wave and current pressure. Considering failure mechanism, stability assessment was performed for the strength limit state and service limit state of the dolphins. The friction angle of the crushed stone as a filling material was reduced to $38^{\circ}$ considering the possibility of contracting behavior as the impact.

  • PDF

A Recommendation of the Technique for Measurement and Analysis of Passive Surface Waves for a Reliable Dispersion Curve (신뢰성 있는 분산곡선의 결정을 위한 수동표면파 측정 및 분석기법의 제안)

  • Yoon, Sung-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.2
    • /
    • pp.47-60
    • /
    • 2007
  • Conventional active surface wave measurements performed using a transient or continuous source are often limited in the maximum depth of penetration due to the difficulty of generating low-frequency energy with reasonably portable sources. This limitation may inhibit accurate seismic site response calculations because of the inability to define deeper subsurface structure. By measuring surface wave generated by passive sources including microtremors and cultural noise, it is possible to overcome this problem and develop soil stiffness profiles to much larger depth. Reliability of dispersion estimates from the passive surface wave measurements is critical to present reliable shear wave velocity profiles and can be improved by the measurements and analyses of passive surface waves based on correct understanding of systematic errors included in passive dispersion data. In this study, the systematic errors caused by poor wavenumber resolution and energy leakage into sidelobes in passive tests are mainly explored. Recommendations for reliable passive surface wave measurements and dispersion estimates are presented and illustrated at a site in San Jose, California, U.S.

Study on the Changes of Dentinal Hypersensitivity and Surface Characteristics Following the Various Root Treatment (수종의 치근면 처치 방법에 따른 상아질 지각 과민 변화 및 표면 특성에 관한 연구)

  • Kwon, Soon-Young;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.51-63
    • /
    • 1999
  • Exposure of the root surface due to gingival recession after periodontal surgery, elicit pain response when exposed to mechanical, heat, chemical or osmotic irritation. Especially patients treated with periodontal surgery, show high frequency. There have been reports that the 1 out of 7 patients complains of dentinal hypersensitivity. There have been many studies on the clinical effects of various materials on the treatment of dentinal hypersensitivity. The purposes of this study were to evaluate the effect of sodium chloride and potassium oxalate and to observe the relationship between the dentinal hypersensitivity and surface characteristics such as dentinal tubule size and number. This study included 20 teeth which were scheduled for extraction and had no pulpal disease. These teeth were divided into Root planing group, EDTA group, NaCl group and Oxalate group. Dentinal hypersensitivity is measured by tactile, pressured air and cold water using NRS (Numerical Rating Scales). Teeth were extracted under local anesthesia and each specimen was sectioned to a size about 3 X 5 mm and was examined under the scanning electron microscope (X2,000) The results were as follows, 1. The EDTA group exhibited significantly increased dentinal hypersensitivity comparing with the other groups. 2. The NaCl and Oxalate groups showed significantly reduced dentinal hypersensitivity comparing with the EDTA group. 3. As a method for dentinal hypersensitivity measurement, it was presumed thet tactile sensitivity test was not sensitive method but air blast test and cold water test were adequate method. 4. In a SEM study, the root planing group exhibited amorphous smear layer and showed no dentinal tubule orifice, but the EDTA group showed the large number of dentinal tubules. On the other hand, the NaCl and Oxalate groups did not show exposed dentinal tubules. The NaCl group showed more rough root surface than the EDTA group, and the Oxalate group showed many participates to be presumed as calcium oxalate particle. As the results from this study, root planing couldn't expose the dentinal tubule and NaCl and potassium oxalate occluded exposed dentinal tubule effectively. Dentinal hypersensitivity has close relationship with the exposure of dentinal tubules, especially with it's size and number.

  • PDF

Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings (초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.19-33
    • /
    • 2008
  • Dynamic response measurements from natural excitation were carried out for 25- and 42-story buildings to evaluate their inherent properties, such as natural frequencies, mode shapes and damping ratios. Both are reinforced concrete buildings adopting a core wall, or with shear walls as the major lateral force resisting system, but frames are added in the plan or elevation. In particular, shear walls in a 25-story building are converted to frames from the 4th floor level downwards while maintaining a core wall throughout, resulting in a fairly complex structure. Due to this, along with similar stiffness characteristics in the principal directions, significantly coupled and closely spaced modes of motion are expected in this building, making identification rather difficult. By using various state-of-the-art system identification methods, the modal parameters are extracted, and the results are then compared. Three frequency-domain and four time-domain based operational modal identification methods are considered. Overall, all natural frequencies and damping ratios estimated from the different identification methods showed a greater consistency for both buildings, while mode shapes exhibited some degree of discrepancy, varying from method to method. On the other hand, in comparison with analysis results obtained using the initial finite element(FE) models, test results exhibited a significant difference of about doubled frequencies, at least for the three lower modes in both buildings. To improve the correlation between test and analysis, a few manual schemes of FE model updating based on plausible reasons have been applied, and acceptable results are obtained. The advantages and disadvantages of each identification method used are addressed, and some difficulties that might arise from the updating of FE models, including automatic procedures, for such large structures are carefully discussed.

Adaptive Enhancement Algorithm of Perceptual Filter Using Variable Threshold (가변 임계값을 이용한 지각 필터의 적응적인 음질 개선 알고리즘)

  • 차형태
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.6
    • /
    • pp.446-453
    • /
    • 2004
  • In this paper, a new adaptive perceptual filter using variable threshold to enhance audio signals degraded by additively nonstationary noise is proposed. The adaptive perceptual filter updates variable threshold each time according to the power of signal and the effect of noise variation. So the noisy audio signal is enhanced by the method which controls a residual noise effectively. The proposed algorithm uses the perceptual filter which transforms a time domain signal into frequency domain and calculates an intensity energy and an excitation energy in bark domain. In this method. the stage updated the response of filter is decided by threshold. The proposed algorithm using vairable threshold effectively controls a residual noise using the energy difference of audio signals degraded by the additive nonstationary noise. The proposed method is tested with the noisy audio signals degraded by nonstationary noise at various signal -to-noise ratios (SNR). We carry out NMR and MOS test when the input SNR is 15dB. 20dB. 25dB and 30dB. An approximate improvement of 17.4dB. 15.3dB, 12.8dB. 9.8dB in NMR and enhancement of 2.9, 2.5, 2.3, 1.7 in MOS test is achieved with the input signals. respectively.

Dynamic Characteristic Analysis Procedure of Helicopter-mounted Electronic Equipment (헬기 탑재용 전자장비의 동특성 분석 절차)

  • Lee, Jong-Hak;Kwon, Byunghyun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.759-769
    • /
    • 2013
  • Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.

A Study on the Efficiency of Clinical Practice for Nursing Education in the Junior College of Nursing in Korea (전문대학 간호과의 임상 실험 효율화를 위한 연구)

  • Lee, Kun-Ja;Kim, Myung-Soon;Yang, Young Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.3 no.2
    • /
    • pp.77-108
    • /
    • 1989
  • The purpose of this study was to find out the present condition of clinical practice and to develop a scheme on the efficiency of clinical practice for nursing education in junior college of nursing in korea. This study was conducted by 2 sections. Ist section was to find out the present condition of clinical practice to 42 directors of nursing collegd and data were collected July 8 to September 30, 1988. 2nd section wat to develop a scheme on the efficiency of clinical practice for nursing education and subjects were nursing professors 258: and clinical nurses 223 in 42 junior nursing colleges their clinical settings in korea. So total subjects were 481. Data were collected july 8, 1988 to June 30, 1988 and were analysed to get the mean, standand deviation, frequency, percentage, t-test, x-test used by SPSS - pc. Major findings were as follows: 1. The present condition of clinical education in junior college of nursing in Korea. 1) 32 colleges (76.2%) were managed by a-yeas system. 2) 25 colleges (59.5%) were performed by individual practice for each subject. 3) 4 weeks interval between class education and clinical education was a major type among total colleges(36.6%, J5 colleges) 4) 30 colleges (71.4%) provided clinical education for all subjects that should be practiced. Nursing administration wes not practiced in 5 colleges (41.9%) among the remainder(12 colleges). The main cause that all practice subjects were not practiced was the lack or absence of suitable clinical settings(8 colleges. 66.7%) 5) 18 colleges (42.9%) responded that a clinical educator was, subject-charged professor. 6) 12 colleges (29.3%) responded that a clinical instructor was in charge of 6~10 students. 7) The evaluation ration ratio(professor to head nurse) by each evaluator was mostly 50% to 50 % and 60% to 40%, respectively 11 colleges(27.5%) The most common evaluation methods were evaluation by head nures, report, presence, conference (11 colleges, 27.5%) 8) The field carrier of professor was mostly 2 years (79 persons, 20.7%) and mean was 3.2 years. The education carrier of a professor was mostly over than 6 years (261 persons, 66.4%) and mean was 9.2 years. The charge hours per-week of a professor were mostly 16-18 hours (16 persons, 131.8%) 9) 34 colleges (82.9%) approved that clinical practice hour was class hour and 18 colleges (43.9 %) counted that 2 hours of clinical education equaled 1 hour of class education. 2. A study 'on the efficiency of clinical practice for nursing education. L) general characteristics of subjects were as follows: kung-sang province (145 persons, 30.5%), 30-34 years (190 persons, 39.8%), graduated degree (245 persons, 51.5%), 6-10 years of carrier (199 persons, 41.4%) were the majority. 2) suitable clinical setting was responded the systematic ward with responsible clinical educator by 210 persons(43.8%) The response by working field of subjects showed a significant difference (p< 0.01) 3) 259 subjects (54.0%) responded that the desirable qualfication of clinical instructor was 3-5 years of clinical experience with master degree or higher. 4) The mean score of desirable quality degree of clinical instructor was 3.43 professors, score (3.54) was significantly higher than clinical nurses' (3.28) (p<0.01) 412 subjects (86.0%) responded that the insufficient guality of instructor was improved by continuing to seek more new information in reference. 5) 196 subjects (41.4%) responded that desirable qualification of head nurse was more than 2 years of head position among 5 years of clinical experience. The response by working' field of subjects showed a significant difference (p<0.05) 6) The mean score of desirable quality degree of head nurse was 3.18 Clinical nurses' score(3.38) was significantly higher than professors' (3.01) (p<0.01) 419 subjects (87.8%) responded that the insufficient of head nurse was improved by continuing relationship with instructor and being responsible from planing of clinical education. 7) The mean score of performance level of the desirable clinical education guide incollege was 2.91 Professors' score (2.96) was significantly higher than clinical nurses' (2.84) (p<0.01) 340 subjects (71.1%) responded that the possible resolution for poor performance was the more specified syllabus of clinical education and the satisfiable orientation for students. 8) The mean score of performance level of the desirable clinical education guide in hospital was 3.03 9) 141 subjects (29.6%) responded that the desirable clinical evaluator was the group of professor, head nurse, staff nurse. Response by working field of subjects was a significant difference (p< 0.05) 10) The mean score of performance level of the evaluation content needed in clinical education was 3.50 Clinical nurses' score (3.56) was significantly higher than professors' (3.45) (p<0.01) 11) 433 subjects (90.2%) responded that6 desirable evaluation method for clinical education was the presence. 12) The mean score of performance level about how personal difference among clinical educators was minimized was 2.89 and response by working field of subjects was not significant. The cause of poor performance was too much workload at clinical settings and too many students st colleges by 386 subjects (81.1%).

  • PDF

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

A Descriptive Study of Oral Health Knowledge & Behaviors in Middle School Students (일부지역 중학생의 구강건강 지식 및 행동에 관한 조사연구)

  • Yoo, Jung-Sook;Kim, Jung-Hee;Han, Su-Jin;Sim, Sang-Hyo;Kim, Yoon-Shin
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.9 no.1
    • /
    • pp.85-97
    • /
    • 2008
  • Objectives: This study was designed to understand the oral health knowledge & conduct of middle-school students, search for the learning objective and the educational method in line with the subjects and of utilizing as the basic data for an effective oral health-care program. Methods: The samples to achieve the purpose of this research are composed of 139 students in middle-school, OO county. Chungcheongbuk-do, the number of male students 64, and female students 75. Data were statistically analyzed by frequency analysis, $x^2$-test or Fisher's exact test by using SPSS WIN Ver. 12.0. Results: Among items on oral-health knowledge in middle-school students. the awareness ratio on a cause and preventive method for oral disease was surveyed to be lower than the awareness ratio on symptoms of oral disease. As a result of examining by comparing knowledge and behavior on the time of tooth brush. both awareness and behavior were the level of 50% or less than it. In particular, 46.2% perceived after lunch. but practice just accounted for 33.0%. The frequency of tooth brush a day was the largest in a case(47.5%) of doing twice a day. However. there was also the response (5.8%) with saying of brushing once or not brushing even once. Thus, the practice of tooth brush was surveyed to be very low even if being a minority of students. The frequency of taking a light meal was 68.8% in less than twice a day. However, even students of taking more than five times were surveyed to be 9.8%. Out of the whole-body health in over 50%-59.9%. the oral health was surveyed to be perceived to be very important. Compared to the awareness level on importance of a tooth, the ratio of visiting a dentistry was analyzed to be very low. Conclusions: The study results suggest that the school oral-health project was examined to have the necessity of being expanded and carried out even in middle-and-high schools, by which the specific oral-health promotion program including oral-health education in this period is developed.

  • PDF

Catalog use study : with reference to universities in Daegu (대학도서관의 목록이용연구)

  • 최달현
    • Journal of Korean Library and Information Science Society
    • /
    • v.9
    • /
    • pp.241-266
    • /
    • 1982
  • This paper gives a summary and overview of a survey conducted at the catalogues of five universities in Daegu during November 1982. The major objective of this study was to secure information about user needs in order to improve the catalogue in Korean university libraries. Data was collected by a combined method of questionnaire and interview. A total of 379 respondents were taken on a randomly selected sample of catalogue users. Results of the survey can be summarized as follows: 1. Eighty-eight percent of the students answered that they had used the library more than twice a month. Nevertheless the number of students consulting the catalogue with the same frequency was only 220, or a n.0, pproximately 58 percent. Those who used the library most tended to use the catalogue more than those who rarely came to the library. 2. Those who had been shown how to use their own catalogue were only 32.5percent of which the students found the instruction sufficient for them to be able to use the catalogue were only 37.5 percent. In particular, they stated that instructions by printed materials and/or library orientation were so poor that they didn't give much help in using the catalogue. This problem makes many libraries to review their own method of instruction in order to encourage patrons to use the catalogue more effectively. 3. Most of the students consulted the catalogue in order to locate library materials. Known-item searches and subject searches were 84 and 16 percent respectively. While 70.5 percent of the students used the author-title catalogue without any difficulties, only 35.5 percent of those stated that using the classed catalogue was easy. 4. It was surprising that the number of students using title access in the search was far greater than that of students using author access. In contrast with this, other studies conducted by many earlier overseas investigators revealed that the great majority of patrons tended to use the latter first. Therefore, we should put more emphasis on the title entries in the catalogue itself as well as cataloging rules. 5. Most useful bibliographic elements in the entry were author, title, call number, date and publisher whereas edition, series statement and the location of publisher were rarely used compared with the other elements. Content note was the most desirable element in the entry to be involved, for many catalogers were used not to describe it on the note area. 6. The chief reason given for not using the catalogue was "I can manage without it" with "It's difficult to understand contents of the card entry." The other one was "It's useless to search materials by the catalogue because I've failed so many times to obtain them out of the stock." In response to this, circulation and acquisition system should be improved not to make such complaints any more.

  • PDF