Feedback control strategies for active control of noise inside a 3-D vibro-acoustic cavity
-
- Smart Structures and Systems
- /
- 제20권3호
- /
- pp.273-283
- /
- 2017
This paper presents and compares three feedback control strategies for active control of noise inside a 3-D vibro-acoustic cavity. These are a) control strategy based on direct output feedback (DOFB) b) control strategy based on linear quadratic regulator (LQR) to reduce structural vibrations and c) LQR control strategy with a weighting scheme based on structural-acoustic coupling coefficients. The first two strategies are indirect control strategies in which noise reduction is achieved through active vibration control (AVC), termed as AVC-DOFB and AVC-LQR respectively. The third direct strategy is based on active structural-acoustic control (ASAC). This strategy is an LQR based optimal control strategy in which the coupling between the various structural and the acoustic modes is used to design the controller. The strategy is termed as ASAC-LQR. A numerical model of a 3-D rectangular box cavity with a flexible plate (glued with piezoelectric patches) and with other five surfaces treated rigid is developed using finite element (FE) method. A single pair of collocated piezoelectric patches is used for sensing the vibrations and applying control forces on the structure. A comparison of frequency response function (FRF) of structural nodal acceleration, acoustic nodal pressure, and piezoelectric actuation voltage is carried out. It is found that the AVC-DOFB control strategy gives equal importance to all the modes. The AVC-LQR control strategy tries to consume the control effort to damp all the structural modes. It is seen that the ASAC-LQR control strategy utilizes the control effort more intelligently by adding higher damping to those structural modes that matter more for reducing the interior noise.
발사체의 구조해석적인 측면에서 외부하중에 따른 발사체의 반응을 파악하는 것은 중요한 일이다. 기본적으로 발사체는 응력집중이나 내부 모듈간의 변위 간섭 등이 일어나지 않게 설계되어야한다. 이를 위해서는 외부하중에 관한 연구가 선행되어야 한다. 발사체에 작용하는 외부하중 중 연소 및 배기에 의해 발생하는 음향하중은 통계적 방법으로 다루어야 하는 랜덤 하중이다. 본 연구에서는 발사시 작용하는 음향하중에 대하여 하중 함수를 구성하고, 이를 이용하여 발사체의 하중해석을 수행하였다. 음원 할당 방법으로 음향하중을 추정하여 하중함수를 구성하였고, 이를 발사체의 유한요소 모델에 적용하였다. 응력해석을 이용하여 발사체의 구조 강성을 확인할 수 있었으며, 발사체 각 섹션의 경계면에서의 가속도 파워 스펙트럴 밀도함수를 구할 수 있었다. 이러한 결과를 이용하여 각 섹션의 진동 시험에 필요한 스펙을 도출할 수 있다.
유도 전동기를 전압 제어하기 위한 최적 PWM 스위칭 방법을 제시하려한다. 전압 인버터의 공간 벡터 변조 방식은 DC-버스 이용을 향상시키고 정류 손실을 감소시키기 때문에 디지털 구현의 경우 특히 선호하는 PWM 방법이다. 유도 전동기 전압 제어를 위한 최적 PWM 스위칭 방법은 제시한 최적 PWM 알고리즘을 사용하여 두 개의 활성 전압 벡터(active voltage vector)와 하나의 영 전압 벡터(zero voltage vector)로 구성하였다. 선택된 스위칭 순차 열은 변조 지수(modulation index)와 운송파(carrier wave) 주기의 함수로 정의 된다. 순차 열은 인버터 스위칭 손실과 전류 리플 값을 기준으로 사용하여 선택된다. 실험 결과 중 저 전력용으로 사용할 경우 스위칭 주파수를 증가시킴에 따라 고조파 왜곡이 감소하고 동특성이 좋아짐을 확인할 수 있었다.
Objectives . The types of Sasang constitutional medicine (SCM) have definite effect on response to herbal drugs. The majority of human P45O dependent xenobiotic metabolism is carried out by polymorphic enzymes which can cause abolished, altered or enhanced metabolism. Therefore, we evaluated the relation of major CYP2C19, 2D6 polymorphism with Sasang types. Methods : 214 healthy subjects were recruited with informed consent; 172 among them had Sasang diagnosis by QSCC2. CYP2D6, 2C19 polymorphism were determined by PCR-RFLP method. Results : None of the Sasang types showed significant difference in CYP2D6, 2C19 polymorphism. However, the Tae-um type showed relatively low frequency of CYP2D6
To develop and evaluate the real-time SAR(Synthetic Aperture Radar) motion measurement system, true antenna phase center(APC) positions during SAT(Synthetic Aperture Time) are needed. In this paper, CDGPS(Carrier phase Differential Global Positioning System) post processing method is proposed to get the true APC position for spotlight SAR image formation. The CDGPS position is smoothed to remove high frequency noise which exists inherently in the carrier phase measurement. This paper shows smoothed CDGPS data is enough to provide the true APC for high-quality SAR image formation through motion measurement result, phase error estimation and IRF(Impulse Response Function) analysis.
OBJECTIVES : The objective of this research is to determine the moisture resistance of the freeze-thaw process occurring in low-noise porous pavement using either hydrated-lime or anti-freezing agent. Various additives were applied to low-noise porous asphalt, which is actively paved in South Korea, to overcome its disadvantages. Moreover, the optimum contents of hydrated-lime and anti-freezing agent and behavior properties of low-noise porous asphalt layer are determined using dynamic moduli via the freeze-thaw test. METHODS : The low-noise porous asphalt mixtures were made using gyratory compacters to investigate its properties with either hydrated-lime or anti-freezing agent. To determine the dynamic moduli of each mixture, impact resonance test was conducted. The applied standard for the freeze-thaw test of asphalt mixture is ASTM D 6857. The freeze-thaw and impact resonance tests were performed twice at each stage. The behavior properties were defined using finite element method, which was performed using the dynamic modulus data obtained from the freeze-thaw test and resonance frequencies obtained from non-destructive impact test. RESULTS : The results show that the coherence and strength of the low-noise porous asphalt mixture decreased continuously with the increase in the temperature of the mixture. The dynamic modulus of the normal low-noise porous asphalt mixture dramatically decreased after one cycle of freezing and thawing stages, which is more than that of other mixtures containing additives. The damage rate was higher when the freeze-thaw test was repeated. CONCLUSIONS : From the root mean squared error (RMSE) and mean percentage error (MPE) analyses, the addition rates of 1.5% hydrated-lime and 0.5% anti-freezing agent resulted in the strongest mixture having the highest moisture resistance compared to other specimens with each additive in 1 cycle freeze-thaw test. Moreover, the freeze-thaw resistance significantly improved when a hydrated-lime content of 0.5% was applied for the two cycles of the freeze-thaw test. Hence, the optimum contents of both hydrated-lime and anti-freezing agent are 0.5%.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
Background: Although quantitative sensory test (QST) is being used with increasing frequency for measuring sensory thresholds in clinical practice and epidemiologic studies, there has been no age-matched normative data in Korean adults. The objective of this study is to evaluate the value of QST in diabetic polyneuropathy with normal range in Korean adults. Methods: The Computer Aided Sensory Examination IV 4,2 (WR Medical Electronics Co., Stillwater, Minnesota, U.S.A.), with 4,2,1 stepping algorithm was used to determine vibration and cold perception threshold in 70 normal controls and 19 patients with diabetic polyneuropathy aged from 21 to 79 years. The data were used to define age-matched upper and lower normal limits and normal range of side to side difference. We also evaluated the duration of diabetes, serum HbA1C level, and findings of nerve conduction study (NCS) and QST in patients with diabetic polyneuropathy. Results: In normal adults, sensory thresholds slightly increased with age, and a slight side-to-side difference was observed. The diagnostic sensitivity of QST was not higher than NCS in patients with diabetic polyneuropathy (36.8% vs. 42.1%, p=0.716), especially among elderly patients. Conclusions: QST might be used as a complementary test for NCS in the diagnosis of diabetic polyneuropathy. Although the QST is a simple method for the evaluation of peripheral nerve function, there are some limitations. Most of all, because the QST measuring is dependent on the subjective response of patients, the degree of concentration and cooperation of the patients can significantly affect the result. And thus, attention should be paid during the interpretation of QST results in patients with peripheral neuropathy.
Type II collagen (CII), major component of hyaline cartilage, has been considered as an auto-antigen in rheumatoid arthritis (RA). However, the clinical and biological significances with regard to the CII autoimmunity need to be clarified in human RA. The presence of antibodies to CII has been identified in sera, synovial fluid, and cartilage of patients with RA. In our study, the increased titer of IgG anti-CII in sera was well correlated with C-reactive protein, suggesting that this antibody may reflect the inflammatory status of RA. The titer of anti-CII antibodies (anti-CII Abs) tended to be higher in early stages of diseases. In our extending study, among 997 patients with RA, 269 (27.0%) were positive for circulatory IgG antibody to CII, those levels were fluctuated over time. It is hard to assess the significant amount of T cell responses to CII and CII (255~274) in RA. By using a sensitive method of antigen specific mixed lymphocyte culture, we can detect the presence of CII-reactive T cells in peripheral blood mononuclear cells of RA patients. Sixty seven (46.9%) of 143 patients showed positive CII reactive T cell responses to CII or CII (255~274). The frequencies of CII reactive T cells were more prominent in inflamed synovial fluid (SF) than in peripheral blood. These T cells could be clonally expanded after consecutive stimulation of CII with feeding of autologous irradiated antigen presenting cells (APC). Moreover, the production of Th1-related cytokine, such as IFN-