• Title/Summary/Keyword: Frequency Domain Decomposition

Search Result 136, Processing Time 0.034 seconds

System identification of a cable-stayed bridge using vibration responses measured by a wireless sensor network

  • Kim, Jeong-Tae;Ho, Duc-Duy;Nguyen, Khac-Duy;Hong, Dong-Soo;Shin, Sung Woo;Yun, Chung-Bang;Shinozuka, Masanobu
    • Smart Structures and Systems
    • /
    • v.11 no.5
    • /
    • pp.533-553
    • /
    • 2013
  • In this paper, system identification of a cable-stayed bridge in Korea, the Hwamyung Bridge, is performed using vibration responses measured by a wireless sensor system. First, an acceleration based-wireless sensor system is employed for the structural health monitoring of the bridge, and wireless sensor nodes are deployed on a deck, a pylon and several selected cables. Second, modal parameters of the bridge are obtained both from measured vibration responses and finite element (FE) analysis. Frequency domain decomposition and stochastic subspace identification methods are used to obtain the modal parameters from the measured vibration responses. The FE model of the bridge is established using commercial FE software package. Third, structural properties of the bridge are updated using a modal sensitivity-based method. The updating work improves the accuracy of the FE model so that structural behaviors of the bridge can be represented better using the updated FE model. Finally, cable forces of the selected cables are also identified and compared with both design and lift-off test values.

Full Scale Measurement on Stay Cables of a Cable Stayed Bridgefor Estimation of Damping Ratios (실교량 계측에 기반한 사장 케이블의 감쇠비 추정)

  • Kim, Saang-Bum;Im, Duk-Ki;Kim, Chang-Hyun;Lee, Jong-Sup
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.421-424
    • /
    • 2009
  • 사장교 케이블의 감쇠비를 추정하기 위하여 실교량 계측을 수행하였다. 사장교 케이블은 감쇠비가 낮고, 고유 진동수가 케이블의 길이에 따라 넓은 범위에 걸쳐 분포하므로, 바람이나 지점 가진에 의하여 과도한 진동이 발생될 수 있다. 케이블 진동 현상의 원인과 발생되고 진행되는 구조는 다양하나, 진동 현상의 가장 중요한 요소는 감쇠비이며, 케이블 진동의 과도한 진동을 감소시키기 위하여, 케이블의 감쇠비를 증가시키는 방법이 널리 사용되고 있다. 사장교 케이블의 다양한 진동 현상에 대한 발생 여부를 판단하고, 케이블 댐퍼와 같은 여러 제진 대책을 설계하고, 설치된 케이블 제진 대책의 성능을 검증하기 위해서는, 케이블의 감쇠비를 추정하는 것이 매우 중요하다. 일반적으로 사용되어져 온 케이블의 감쇠비 추정 방법은 정해진 모드로 자유 진동을 발생시킨 후, 진폭의 감소 추세로부터 Logarithmic Decrement를 계산하여 감쇠비를 구하는 방법이다. 그러나 수백m에 이르는 긴 케이블에서 정해진 모드의 자유 진동을 발생시키는 것은 쉽지 않다. 최근에는 상시 진동으로부터 감쇠비를 추정하는 여러 기법들이 개발되어져 왔으며, Frequency Domain Decomposition Method나 Stochastic Subspace Identification Method 등이 많이 사용되고 있다. 이 논문에서는, 상시진동 기반의 기법들을 사용하여, 사장교 케이블의 감쇠비를 추정하였으며, 추정된 감쇠비의 신뢰도를 높이기 위해, 측정시간을 늘리고, 가진 풍하중의 영향을 반영하여 보정하였다. 또한 추정된 감쇠비를 Buffeting 진동과 와류 진동과 같이 진동 현상과 진폭별로 분석하였다.

  • PDF

Identification of Open-Switch and Short-Switch Failure of Multilevel Inverters through DWT and ANN Approach using LabVIEW

  • Parimalasundar, E.;Vanitha, N. Suthanthira
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2277-2287
    • /
    • 2015
  • In recent times, multilevel inverters are given high priority in many large industrial drive applications. However, the reliability of multilevel inverters are mainly affected by the failure of power electronic switches. In this paper, open-switch and short-switch failure of multilevel inverters and its identification using a high performance diagnostic system is discussed. Experimental and simulation studies were carried out on five level cascaded H-Bridge multilevel inverter and its output voltage waveforms were analyzed at different switch fault cases and at different modulation index values. Salient frequency domain features of the output voltage signal were extracted using the discrete wavelet transform multi resolution signal decomposition technique. Real time application of the proposed fault diagnostic system was implemented through the LabVIEW software. Artificial neural network was trained offline using the Matlab software and the resultant network parameters were transferred to LabVIEW real time system. In the proposed system, it is possible to precisely identify the individual faulty switch (may be due to open-switch (or) short-switch failure) of multilevel inverters.

Modal identification of Canton Tower under uncertain environmental conditions

  • Ye, Xijun;Yan, Quansheng;Wang, Weifeng;Yu, Xiaolin
    • Smart Structures and Systems
    • /
    • v.10 no.4_5
    • /
    • pp.353-373
    • /
    • 2012
  • The instrumented Canton Tower is a 610 m high-rise structure, which has been considered as a benchmark problem for structural health monitoring (SHM) research. In this paper, an improved automatic modal identification method is presented based on a natural excitation technique in conjunction with the eigensystem realization algorithm (NExT/ERA). In the proposed modal identification method, damping ratio, consistent mode indicator from observability matrices (CMI_O) and modal amplitude coherence (MAC) are used as criteria to distinguish the physically true modes from spurious modes. Enhanced frequency domain decomposition (EFDD), the data-driven stochastic subspace identification method (SSI-DATA) and the proposed method are respectively applied to extract the modal parameters of the Canton Tower under different environmental conditions. Results of modal parameter identification based on output-only measurements are presented and discussed. User-selected parameters used in those methods are suggested and discussed. Furthermore, the effect of environmental conditions on the dynamic characteristics of Canton tower is investigated.

Theoretical and experimental dynamic characteristics of a RC building model for construction stages

  • Turker, Temel;Bayraktar, Alemdar
    • Computers and Concrete
    • /
    • v.17 no.4
    • /
    • pp.455-475
    • /
    • 2016
  • Dynamic characteristics, named as natural frequencies, damping ratios and mode shapes, affect the dynamic behavior of buildings and they vary depending on the construction stages. It is aimed to present the effects of construction stages on the dynamic characteristics of reinforced concrete (RC) buildings considering theoretical and experimental investigations. For this purpose, a three-storey RC building model with a 1/2 scale was constructed in the laboratory of Civil Engineering Department at Karadeniz Technical University. The modal testing measurements were performed by using Operational Modal Analysis (OMA) method for the bare frame, brick walled and coated cases of the building model. Randomly generated loads by impact hammer were used to vibrate the building model; the responses were measured by uni-axial seismic accelerometers as acceleration. The building's modal parameters at these construction stages were extracted from the processed signals using the Enhanced Frequency Domain Decomposition (EFDD) technique. Also, the finite element models of each case were developed and modal analyses were performed. It was observed from the experimental and theoretical investigations that the natural frequencies of the building model varied depending on the construction stages considerably.

Determination of optimal accelerometer locations using modal sensitivity for identifying a structure

  • Kwon, Soon-Jung;Woo, Sungkwon;Shin, Soobong
    • Smart Structures and Systems
    • /
    • v.4 no.5
    • /
    • pp.629-640
    • /
    • 2008
  • A new algorithm is proposed to determine optimal accelerometer locations (OAL) when a structure is identified by frequency domain system identification (SI) method. As a result, a guideline is presented for selecting OAL which can reflect modal response of a structure properly. The guideline is to provide a minimum number of necessary accelerometers with the variation in the number of measurable target modes. To determine OAL for SI applications effectively, the modal sensitivity effective independence distribution vector (MS-EIDV) is developed with the likelihood function of measurements. By maximizing the likelihood of the occurrence of the measurements relative to the predictions, Fisher Information Matrix (FIM) is derived as a function of mode shape sensitivity. This paper also proposes a statistical approach in determining the structural parameters with a presumed parameter error which reflects the epistemic paradox between the determination of OAL and the application of a SI scheme. Numerical simulations have been carried out to examine the proposed OAL algorithm. A two-span multi-girder bridge and a two-span truss bridge were used for the simulation studies. To overcome a rank deficiency frequently occurred in inverting a FIM, the singular value decomposition scheme has been applied.

Grouping effect on the seismic response of cabinet facility considering primary-secondary structure interaction

  • Salman, Kashif;Tran, Thanh-Tuan;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1318-1326
    • /
    • 2020
  • Structural modification in the electrical cabinet is investigated by a proposed procedure that comprises of an experimental, analytical and numerical solution. This research emphasizes the linear dynamic analysis of the cabinet that is studied under the seismic excitation to demonstrate the real behavior of the cabinets in NPP. To this end, an actual electric cabinet is experimentally tested using an impact hammer test which reveals the fundamental parameters of the cabinet. The Frequency-domain decomposition (FDD) method is used to extract the dynamic properties of the cabinet from the experiment which is then used for numerical modeling. To validate the dynamic properties of the cabinet an analytical solution is suggested. The calibrated model is analyzed under the floor response obtained from the Connecticut nuclear power plant structure excited by Tabas 1978 (Mw 7.4) earthquake. Eventually, the grouping effect of the cabinets is proposed which represents the influence on the dynamic modification. This grouping of the cabinets is described more sophisticatedly by the theoretical understating, which results in a significant change in the seismic response. Considering the grouping effects will be helpful in the assessment of the real seismic behavior, design, and performance of cabinets.

Quadtree Based Infrared Image Compression in Wavelet Transform Domain (웨이브렛 변환 영역에서 쿼드트리 기반 적외선 영상 압축)

  • 조창호;이상효
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3C
    • /
    • pp.387-397
    • /
    • 2004
  • The wavelet transform providing both of the frequency and spatial information of an image is proved to be very much effective for the compression of images, and recently lot of studies on coding algorithms for images decomposed by the wavelet transform together with the multi-resolution theory are going on. This paper proposes a quadtree decomposition method of image compression applied to the images decomposed by wavelet transform by using the correlations between pixels and '0'data grouping. Since the coefficients obtained by the wavelet transform have high correlations between scales and high concentrations, the quadtree method can reduce the data quantity effectively. the experimental infrared image with 256${\times}$256 size and 8〔bit〕, was used to compare the performances of the existing and the proposed compression methods.

Investigation of water length effects on the modal behavior of a prototype arch dam using operational and analytical modal analyses

  • Sevim, Baris;Bayraktar, Alemdar;Altunisik, Ahmet Can
    • Structural Engineering and Mechanics
    • /
    • v.37 no.6
    • /
    • pp.593-615
    • /
    • 2011
  • This study determines the water length effects on the modal behavior of a prototype arch dam using Operational and Analytical Modal Analyses. Achievement of this purpose involves construction of a prototype arch dam-reservoir-foundation model under laboratory conditions. In the model, reservoir length was taken to be as much as three times the dam height. To determine the experimental dynamic characteristics of the arch dam using Operational Modal Analysis, ambient vibration tests were implemented for empty reservoir and three different reservoir water lengths. In the ambient vibration tests, the dam was vibrated by natural excitations provided from small impact effects and the response signals were measured using sensitive accelerometers. Operational Modal Analysis software process signals collected from the ambient vibration tests, and Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification techniques estimated modal parameters of the dams. To validate the experimental results, 3D finite element model of the prototype arch dam was modeled by ANSYS software for empty reservoir and three different reservoir water lengths, and dynamic characteristics of each model were determined analytically. At the end of the study, experimentally and analytically identified dynamic characteristics compared to each other. Also, changes on the natural frequencies along to water length are plotted as graphs. Results suggest that reservoir water complicates the modal behavior of the arch dam significantly.

Advanced Algorithm for IED of Stator Winding Protection of Generator System (발전기시스템의 고정자보호 IED를 위한 개선된 알고리즘)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.91-95
    • /
    • 2008
  • The large AC generator fault may lead to large impacts or perturbations in power system. The generator protection control systems in Korea have been imported and operated through a turn-key from overseas entirely. Therefore a study of the generator protection field has in urgent need for a stable operation of the imported goods. In present, the algorithm using the current ratio differential relaying based DFT for stator winding protection or a fault detection had been applied that of internal fault protection of a generator. the DFT used for the analysis of transient state signal conventionally had defects losing a time information in the course of transforming a target signal to frequency domain. In this paper, the discrete wavelet transform (DWT) was applied a fault detection of the generator being superior to a transient state signal analysis and being easy to real time realization. The fault signals after executing a terminal fault modeling collect using a MATLAB package, and calculate the wavelet coefficients through the process of a muiti-level decomposition (MLD). The proposed algorithm for a fault detection using the Daubechies WT (wavelet transform) was executed with a C language and the commend line function for the real time realization after analyzing MATLAB's graphical interface. The advanced technique had improved faster a speed of fault discrimination than a conventional DFR based on DFT.