• 제목/요약/키워드: Freon gas

검색결과 24건 처리시간 0.031초

흡착공정을 이용한 프레온-12와 공기혼합가스의 분리 (Separation of Freon-12 and Air Mixture by Adsorption Process)

  • 강석호;이태진;안희관;김윤갑
    • 한국대기환경학회지
    • /
    • 제9권1호
    • /
    • pp.101-106
    • /
    • 1993
  • In order to separate the Freon-12 and air mixture$(CF_2Cl_2/Air=0.1/99.9 vol.%)$ by pressure swing adsorption (PSA), the breakthrough curve was experimentally observed in a fixed bed adsorption column. A single adsorber was packed with various adsorbents such as, the activated carbon(S-AC, W-AC) and the molecular sieve(MS-5A, MS-13X). The order of appearance of breakthrough curve is MS-5A > MS-13X > W-AC > S-AC. The activated carbon was found to be more effective adsorbent for separating Freon-12 from the mixture than the molecular sieve was. From the experimental data obtained by the separation of Freon-12 gas out of the air stream in the steady-state PSA process cycle, whose size is the same one of column used for the breakthrough curve observation, it has been confirmed that Freon-rich gas could be obtained from the purge step of PSA and Freon-free air could be obtained from the adsorption step of PSA cycle.

  • PDF

Freon Gas흡착 및 열처리에 의한 담배조직의 물리적, 역학적 특성변화연구 (Changes in Physical and Mechanical Properties of Freon-Adsorbed and Heat - Treated Leaf Tobacco)

  • 김기환;유광근;주영석
    • 한국연초학회지
    • /
    • 제6권1호
    • /
    • pp.39-49
    • /
    • 1984
  • In the tobacco industry, it is important to study the change of mechanical property occurring the expansion process. The purpose of this study is to attain basic data for development of a tobacco expansion method. 1 . Freon gas was adsorbed to tobacco under various conditions of temperature, relative humidity and pressure, and then the amount of freon gas adsorbed was analyzed by GC. Freon adsorption rate of Burley 21 was more than that of By104 at the same condition and about 17 $\pm$ 1% moisture content produced better adsorption rate. 2. Freon adsorbed sample were heated to about $150^{circ}C\;to\;230^{\circ}C$ in a drying oven and recycle duct form about 2 to 30 seconds, and then the change of mechanical property were measured. Heated leaf was damaged when the tissue was pressed by the force of above $0.5x10^8dyn/cm^2$. The optimum condition of no damage of the sample was below the temperature of 15$0^{\circ}C$ and heating time of 10 seconds. It was more economically advantages to treated sample in a recycle duct than to be in a drying oven. By this process, the specific volume of the heated sample was increased from 80 to 110 percent in comparison to that of untreated sample.

  • PDF

담배 팽화공정에 사용된 Freon-11의 회수 (냉각 및 압축 system에 관해서) (RECOVERY OF FREOU-11 USED IN A PROCESSING SYSTEM OF TOBACCO EXPANSION (ABOUT COOLING AND COMPRESSION SYSTEM))

  • 김기환;유광근;주영석;최영현;김병구
    • 한국연초학회지
    • /
    • 제7권2호
    • /
    • pp.189-197
    • /
    • 1985
  • The purpose of this study is to improve the method and the apparatus for recovering freon-11 used in a process for increasing the filling capacity of tobacco. The first, the theoretical recovery rate of freon-11 was calculated from vapour pressure and thermodynamic properties of freon-11. The second, the usability of theoretical data was evaluated by the comparison between the theoretical data and the experimental data from the pilot plant. The result obtained under the present experiment condition was quite similar to the rate at 15kg/cm2 and 5$^{\circ}C$, but the theoretical data evaluated were 0.1 to 0.3% lower than the experimental data at 20 to 25kg/cm2 and 5$^{\circ}C$. The recovery rate of the cooling and the compression system was about 95% with freon-11 used in this system and that with freon-11 concentrate of waste gas was about 3 to 3.6% at 20 to 25kg/cm2 and 5$^{\circ}C$.

  • PDF

공기를 함유한 프레온 증기의 수평관 외부에서의 막응축 (Filmwise Condensation of Freon Vapor Including Air on a Horizontal Tube)

  • 김경훈;고형종
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.20-29
    • /
    • 1995
  • A theoretical model for film condensation of a vapor including a relatively lighter noncondensable gas on a horizontal tube has been formulated on the basis of the conservation laws and other fundamental physical principles. The model is applied to the prediction of the condensation heat transfer characteristics for the Freon vapor in the presence of air on a horizontal tube. Calculated results for the mean heat transfer coefficient, which is shown to depend strongly on the bulk concentration of air, are in good agreement with the available experimental results for a range of operating conditions. The distributions of physical quantities along the surface of tube are also calculated, such as the boundary layer thickness and local heat transfer coefficient. The present model is readily reduced to the Nusselt model as the bulk concentration of air decreases to zero. Therefore, the transition from the condensation of pure vapor to that of vapor-air mixture occurs continuously not abruptly.

  • PDF

마이크로파를 이용한 프레온의 흡착분리 (Adsorptive Separation of Freon by Microwave Irradiation)

  • 김윤갑;소림오
    • 한국대기환경학회지
    • /
    • 제14권2호
    • /
    • pp.133-142
    • /
    • 1998
  • Gas adsorption on adsorbents depends on temperatures and pressures. When these parameters are fixed, the adsorption capability and selectivity can not be changed. If the gas adsorption is controlled by another factor like electromagnetic field, the adsorption and desorption can be managed by much intentional way. The microwave has characteristics to excite particular components such as water without destroying it. In this study, microwave was irradiated to the adsorbent of an NaY zeolite which is almost transparent to microwave. As vapor of 1, 1, 2- trichloro-1, 2, 2-trifluoroethane (CFC-113) and water flowed simultaneously on the zeolite packed in a column at room temperature, only water was adsorbed. The . adsorbed water was removed from the zeolite and then replaced by CFC-113, since the microwave was irradiated. Greater the power of microwave was, more CFC-113 was adsorbed. The water adsorption took place again after a latent period by stopping the microwave irradiation.

  • PDF

태양열과 프레온 기체 압축열 복합온수기 개발 (The hot water production through the combination of solar thermal energy and freon gas compression heat)

  • 정현채;김기선;선경호;남승영;이종원
    • 태양에너지
    • /
    • 제10권2호
    • /
    • pp.18-27
    • /
    • 1990
  • 태양열과 프레온 R-12 기체 압축열 복합온수기를 개발하여 실용화할 수 있도록 했으며 개발 내용은 다음과 같다. 가. 라디에타형 집열기와 평판형 집열기를 고안하여 프레온 R-12 기체와 액체가 상변이를 하면서 순환하여 태양복사열과 간접복사열을 흡수하고 대기의 대류접촉전열을 통해 대기열을 효과적으로 흡수하도록 개발했다. 나. 저장조하부에 압축기를 위치하도록 하고 압축기 가동시 발생하는 압축기의 표면열과 압축기에서 발생된 기체열이 가장 효과적으로 저장조내에 주입되도록 압축기와 저장조내에 위치한 열교환기의 연결관을 축소화했다. 다. 저장조내에 압축된 기체로부터 열교환을 더욱 효과적으로 하기 위해 열교환기를 새로 고안하여 개발했다. 라. 2801, $50^{\circ}C$ 온수를 매일 생산하도록 하여도 혹한기에 월 6,000원 이하의 전기료가 소요됨을 실측했다. 마. 프레온 R-12 순환시스템으로 우리나라의 기후에서 태양열온수기 제작에 최대 장애요인인 동파문제를 완전제거 할 수 있었고 조작이 완전자동이며 하자 발생요인이 거의 없고 수명이 길며 제작단가가 낮아 보급에 큰 잇점이 있을 것임을 확인했다.

  • PDF

솔더 포일을 이용한 무플럭스 솔더링에 관한 연구 (A Study on Fluxless Soldering using Solder Foil)

  • 신영의;김경섭
    • Journal of Welding and Joining
    • /
    • 제16권5호
    • /
    • pp.100-107
    • /
    • 1998
  • This paper describes fluxless soldering of reflow soldering process using solder foil instead of solder pastes. There is an increasing demand for the reliable solder connection in the recent high density microelectronic components technologies. And also, it is problem fracture of an Ozone layer due to freon as which is used to removal of remained flux on the substrate. This paper discussed joining phenomena, boudability and joining processes of microelectronics devices, such as between outer lead of VLSI package and copper pad on a substrate without flux. The shear strength of joints is 8 to 13 N using Sn/Pb (63/37 wt.%) solder foil with optimum joining conditions, meanwhile, in case of using Sn/In (52/48 wt.%) solder foil, it is possible to bond with low heating temperature of 550 K, and accomplish to high bonding strength of 25N in condition heating temperature of 650K. Finally, this paper experimentally shows fluxless soldering using solder foil, and accomplishes key technology of microsoldering processes.

  • PDF

가변전열 히이트 파이프의 특성에 관한 연구 (An experimental study on heat transfer characteristics of variable conductance heat pipe)

  • 김주년;이영호;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.4-16
    • /
    • 1984
  • The heat-pipe is characterised by the highly effective thermal conductance. In order to change the thermal conductance, the heat-pipe is connected to a reservior having a space which is filled with non-condensable gas. In normal operation, the vapour of working fluid will tend to pump the non- condensable gas into the reservoir and the gas-vapour interface situates at some point along the condenser section. The thermal conductance is affected by non- condensable gas. It is concluded that the suitable position of interface can be used to control the temperature of condenser section. In this experiment, the evaporating part is connected to the lowest position of heat-pipe. The copper heat-pipe which is filled with Freon-113 or distilled water as working fluid utilized. As results of experimental study, thermal conductance can be increased by the operating pressure which is infulenced by non-condensable gas. A correlative equation between the thermal conductance and the mass of non- condensable gas is also obtained.

  • PDF

3D numerical simulation of temperature on Pilot tube

  • Ying Wang;Baogeng Ding
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 PARALLEL CFD 2006
    • /
    • pp.248-251
    • /
    • 2006
  • Multi-physics problem is considered for the Pitot tube located in uniform freon gas flow with high Mach number and the 3D numerical results of temperature on Pitot tube is given. The model is created by using structural module of ANSYS, the grids are obtained by ICEM, and the problem is solved and the data post-processing is done by CFX.

  • PDF