• 제목/요약/키워드: Freezing damage

검색결과 285건 처리시간 0.031초

동결융해 작용을 받은 콘크리트의 촉진중성화 특성 (Accelerated Carbonation of Concrete Deteriorated by Freezing and Thawing)

  • 손유신;김규용;김한준;박찬규;이승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.221-224
    • /
    • 2004
  • Several factors of concrete durability decline factor are acted as complex deterioration and is happened not that happen by simplicity deterioration. Specially, in case of sea construction, as complex salt damage, carbonation and freezing & thawing, concrete surface and pore structure is deteriorated. Therefore, analyzing concrete carbonation and pore structure after freezing and thawing test by fresh water and sea water in this research, we wish to study about acceleration of decline of durability and complex deterioration by concrete surface deterioration in sea environment.

  • PDF

CFRP 판으로 전단 보강된 이후 동결융해에 노출된 철근콘크리트 보의 보강성능 및 파괴특성 (Strengthening Performance and Failure Characteristics of Reinforced Concrete Beams Exposed to Freezing-and-thawing Cycles after Shear Strengthening with CFRP Plate)

  • 윤현도;김선우;전에스더;이민정
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.457-460
    • /
    • 2008
  • CFRP plates has been established as an effective method for rehabilitation and strengthening of concrete structures. The CFRP reinforcements are bonded to beams and slabs using structural adhesives. Adhesive strength can be affected by environmental exposure. During freezing-and-thawing cycling, temperature-induced stresses in the adhesive layer, due to differential thermal expansion between the CFRP and the substrate concrete, may lead to bond damage and contribute to or cause premature CFRP composite separation. This paper presents the results of experimental program undertaken to investigate the effects of freeze-thaw cycling (from -18 to $4^{\circ}C$) on the behavior and failure characteristics of RC beams strengthened in shear with CFRP plate using acoustic emission (AE) technique.

  • PDF

동결보존된 생쥐 고환조직 세포의 광학 및 전자현미경적 관찰 (Light and Electron Microscopic Observation in the Frozen-thawed Mouse Testicular Tissues)

  • 한상철;송상진;이선희;오승한;궁미경;박용석
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제30권2호
    • /
    • pp.127-133
    • /
    • 2003
  • Objective: The aim of this study was to investigate the morphological aspects of testicular tissue before and after freezing-thawing by light and transmission electron microscopy. Methods: Tissue biopsies were carried out on mouse testis for freezing. Samples in medium containing 20% glycerol were frozen by computer-controlled freezing program. The effect of freezing-thawing on the structural change of testicular tissues were examined by light and electron microscopy. Results: The freezing-thawing procedure had no significant effect on tubular diameter. However, it caused folding of the lamina propria, and notable damage to Sertoli cells, spermatogonia and spermatocytes. The cells were detached, desquamated from the basal lamina and had increased vacuolization. Round spermatids, elongated spermatids and spermatozoa were less affected, and most of them maintained their normal structure. Conclusions: The structure of spermatogonia, spermatocyte and basal compartments in seminiferous epithelium was significantly altered by freezing-thawing procedure of mouse testicular tissues. Thus, we need to develop a more reliable method for the cryopreservation of testicular tissues.

단열공법이 적용된 겨울철 도로터널의 동결저감 효과 분석 (Analysis on Freezing Reduction of Road Tunnels with Heat Insulation Method during Winter)

  • 손희수;전경재;윤찬영
    • 한국지반공학회논문집
    • /
    • 제33권8호
    • /
    • pp.17-27
    • /
    • 2017
  • 우리나라 북동부에 위치하고 있는 강원지역은 겨울철 일 평균온도가 영상권을 유지하는 타 지역들과는 달리 일평균온도가 영하로 떨어지는 가장 추운 지역이다. 이에따라 지속적으로 도로터널의 라이닝부에 대한 동결피해 발생 사례가 보고되고 있으나 동결피해 저감을 위한 단열설계 기준 및 관련 연구는 아직까지 매우 부족하다. 본 연구에서는 단열공법 적용에 따른 도로터널의 동결저감 효과를 분석하기 위하여 겨울철 강원지역 도로터널의 지반특성과 기후특성을 고려한 해석적 연구를 수행하였다. 그 결과, 라이닝부의 콘크리트와 숏크리트 두께의 차이는 동결심도에 큰 영향을 미치지 않는 것으로 나타났으나 단열재의 적용 시에는 동결심도가 크게 감소하는 것으로 나타났다. 또한 배면지반의 열전도율과 외기온도 지속지간의 변화에 따라서 동결심도가 큰 영향을 받으므로 이러한 영향을 고려하여 단열재의 두께를 산정하여 적용한다면 우수한 동결저감 효과를 보일 것으로 판단된다.

동상방지층의 구조적 평가를 위한 모형 개발 (Development of Model for Structural Evaluation of Anti-Freezing Layer)

  • 이문섭;허태영;박희문;김부일
    • 한국도로학회논문집
    • /
    • 제14권3호
    • /
    • pp.25-32
    • /
    • 2012
  • 현재 도로포장 설계법에 따르면, 동상방지층의 두께는 지역별 온도조건에 따라 결정되는 동결깊이에 의해 결정되며 동상방지층의 지지력은 설계에서 고려되지 않고 있다. 동상방지층을 도로포장체에서 구조층으로 고려할 경우에는 기존 도로포장층의 두께를 감소시킬 수 있으며 보다 경제적인 도로 포장단면을 구성할 수 있다. 본 연구에서는 동상방지층의 지지력을 평가하기 위한 통계적 모형을 개발하였다. 동상방지층의 구조적 역할을 규명하고 동상방지층 구조적 평가 모형 개발을 위하여 2m 이하 저성토부, 절토부 및 절성경계부 등을 구분하여 포장 하부층에서 Falling Weight Deflectormeter(FWD) 시험을 계절별로 수행하였다. 본 시험은 동방방지층의 유무에 따른 지지력 차이를 규명하기 위하여 동방방지층이 있는 구간과 없는 구간으로 구분하여 수행하였다. 본 시험결과, 동상방지층이 설치된 구간에서의 FWD 처짐량이 동상방지층 미설치 구간에 비해 0.4~82.6% 작게 측정되어 동상방지층이 포장체에서 지지력을 검증하였다. 다양한 FWD 처짐지수와 동상방지층 두께와의 상관관계를 조사한 결과, 보조기층 파손지수의 차이값(${\Delta}BDI$)과 동상방지층 두께와의 상관도가 가장 높았다. 본 논문에서는 ${\Delta}BDI$값을 선형혼합효과 모형에 적용하여 동상방지층을 구조적으로 평가할 수 있는 모형을 개발하였다.

벽돌조 건축문화재 외벽체의 훼손 현황 및 원인 조사 -나주노안천주교회를 중심으로- (Investigation of Defects and Damage on External Wall in Brick Structures of Modern Architectural Properties - Focused on "Naju Noahn Catholic Church" -)

  • 우남식;김태영
    • 한국농촌건축학회논문집
    • /
    • 제15권1호
    • /
    • pp.29-36
    • /
    • 2013
  • This study is to diagnose causes of damage and defects on external walls of brick structures, focused on "Naju Noahn" Catholic Church of Modern Architectural Properties. The causes of crack and deflection are overloading, shortage strength of arch. Among those, main cause is cauesd by shortage strength of arch because center of arch is dislocated and skew back of arch is small angle. The causes of damage and elimination are weathering, plants of friction, freezing and thawing, durability decrement of material and attach defection. This defects and damage is caused by high-moisture that occurs in soil. The causes of discoloration are change of soil moisture and flimsy brickwork. These defects and damage are mainly occurred in coping of cornice, weathering of window sill.

남한산성 여장 손상원인 분석 (Factor Analysis of Deterioration in Namhansanseong Yeojang)

  • 정광용;이상옥;양희제
    • 건축역사연구
    • /
    • 제25권1호
    • /
    • pp.59-68
    • /
    • 2016
  • There are many reasons of damage in Namhansanseong Yeojang. Lots of damage types are observed in each Yeojang. There are many types of damage factors but major damage factor is breakage by freezing and thawing. So Conduct non-destructive evaluation about damage factors in Namhansanseong Yeojang to analysis weathering factors in Yeojang by measuring directional microclimate. The study will pave the way for conservation management in Namhansanseong by suggesting the conservation calendar about weather condition and damage factors.

Food Preservation Technology at Subzero Temperatures: A Review

  • Shafel, Tim;Lee, Seung Hyun;Jun, Soojin
    • Journal of Biosystems Engineering
    • /
    • 제40권3호
    • /
    • pp.261-270
    • /
    • 2015
  • Purpose: Cold storage is the most popular method used to preserve highly perishable foods such as beef and fish. However, at refrigeration temperatures, the shelf life of these foods is limited, and spoilage leads to massive food waste. Moreover, freezing significantly affects the food's properties. Ice crystallization and growth during freezing can cause irreversible textural damage to foods through volumetric expansion, moisture migration induced by osmotic pressure gradients, and concentration of solutes,which can lead to protein denaturation. Methods: Although freezing can preserve perishable foods for months, these disruptive changes decrease the consumer's perception of the food's quality. Therefore, the development and testing of new and improved cold storage technologies is a worthwhile pursuit. Results: The process of maintaining a food product in an unfrozen state below its equilibrium freezing temperature is known as supercooling. As supercooling has been shown to offer a considerable improvement over refrigeration for extending a perishable product's shelf life, implementation of supercooling in households and commercial refrigeration units would help diminish food waste. Conclusions: A commercially viable supercooling unit for all perishable food items is currently being developed and fabricated. Buildup of this technology will provide a meaningful improvement in the cold storage of perishable foods, and will have a significant impact on the refrigeration market as a whole.

식육의 동결, 냉동냉장 및 해동시 내부압력 변화 (Changes of Internal Pressure during Freezing, Frozen Storage and Thawing of Meats)

  • 정진웅;김종훈
    • 한국식품과학회지
    • /
    • 제31권3호
    • /
    • pp.682-687
    • /
    • 1999
  • 식품동결에 의한 품질손상에 있어 크게 영향을 미치는 인자중의 하나가 체적변화에 의한 조직 파괴이므로 본 연구에서는 압력변환기를 사용하여 식육의 동결, 냉동냉장 및 해동시에 일어나는 내부압력을 조사하였다. 그 결과, 우육은 $-20^{\circ}C$에서 밀도는 $942.17\;kg/cm^2$으로, 체적은 6.33% 증가하였으며, 급속 및 완만동결시 우육의 내부압력 변화 경향은 동결 직전에 급격히 상승한 후 동결 초기부터 최대빙결정생성대를 통과하는 동안은 급격히 감소하다가 다시 온도가 내려감에 따라 압력변화는 증가와 감소를 반복하여 상승하는 경향을 보여 주었고, 동결시의 내부압력 크기는 약 $8{\sim}10\;psig$ 수준이며, 내부압력의 변화 경향은 정지공기식보다 침지식에서 약 1 psig 정도 크게 나타났다. 냉동냉장시에 일어나는 내부압력의 상하변화는 돈육의 품온차가 ${\pm}1^{\circ}C$일 때, 시료중량에 마라 $1.84{\sim}2.32\;psig$ 정도의 내부압력 차가 반복적으로 발생됨을 알 수 있었다. 또한, 돈육의 해동시 내부압력은 해동 개시 후 급격히 상승하여 5분 이내에 최고압력에 도달한 이후에는 서서히 하강하였으며, 해동시에 발생한 내부압력의 값은 동결시의 내부압력 값보다도 대부분 크게 나타났다. 또한, 균온처리한 우육의 동결시 내부 압력 값은 약 $1{\sim}4\;psig$ 수준으로 균온처리하지 않은 우육에 비하여 매우 적게 나타났으며, 동결소요시간도 약 $10{\sim}20%$ 정도 짧게 나타났다.

  • PDF

차염성 저발열시멘트의 급속동결융해 저항성에 관한 실험적 연구 (An Experimental Study on Resistance of rapid Freezing and Thawing of Chloride-inhibiting Low-Heat Cement)

  • 심종성;박철우;박성재;강태성;주민관;김태수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.589-592
    • /
    • 2008
  • 이 연구는 겨울철 동결융해 작용으로 인한 차염성 저발열시멘트(CLC)의 내구성을 알아보고자 수행하였다. 내구성 문제는 현장여건에 따라 다소 차이는 있으나, 계절변화에 따른 반복적인 동결융해작용에 의한 콘크리트의 동해는 내구성 저하의 대표적 현상이라 할 수 있으며, 겨울철 동결융해를 받는 콘크리트는 내부에서 큰 팽창력이 발생되어 콘크리트 균열, 표면 박리, 골재 이탈 등의 파손현상을 보이게 된다. 따라서 이 연구에서는 개발된 차염성 저발열시멘트(CLC)의 동결융해 저항성에 따른 내구성 지수를 알아보기 위해 차염성 저발열시멘트(CLC)와 현재 많이 사용되고 있는 고로슬래그시멘트(BFS), 보통 포틀랜드시멘트(OPC)을 각각 물/시멘트비 35%, 40%, 45% 을 변수로 하여 배합을 실시 하여 공시체를 제작하였다. 제작된 공시체를 KS F 2456(급속동결 융해에 대한 콘크리트의 저항 시험방법)방법에 따라 동결융해 시험을 실시하여 상대 동탄성 계수를 측정하였으며, 측정된 상대동탄성 계수를 가지고 내구성지수를 도출하였다. 내구성 지수를 비교 분석한 결과 차염성 저발열시멘트(CLC), 고로슬래그 시멘트(BFS), 보통 포틀랜드 시멘트(OPC) 모두 우수한 내구성 지수를 나타내는 것으로 확인 되었다.

  • PDF