• Title/Summary/Keyword: Free chlorine

Search Result 135, Processing Time 0.024 seconds

Comparison of Dye Removal Performance and Oxidants Formation of Insoluble Electrode (불용성 전극의 Dye 제거 성능과 산화제 생성 비교)

  • Yoo, Young-Eok;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.20 no.10
    • /
    • pp.1273-1284
    • /
    • 2011
  • The aim of this research was to evaluate the performance of insoluble electrode for the purpose of degradation of Rhodamine B (RhB) and oxidants generation [N,N-Dimethyl-4-nitrosoaniline (RNO, indicator of OH radical), $O_3$, $H_2O_2$, free Cl, $ClO_2$)]. Methods: Four kinds of electrodes were used for comparison: DSA (dimensional stable anode; Pt and JP202 electrode), Pb and boron doping diamond (BDD) electrode. The effect of applied current (0.5~2.5 A), electrolyte type (NaCl, KCl and $Na_2SO_4$) and electrolyte concentration (0.5~3.5 g/L) on the RNO degradation were evaluated. Experimental results showed that the order of RhB removal efficiency lie in: JP202 > Pb > BDD ${\fallingdotseq}$ > Pt. However, when concerned the electric power on maintaining current of 1 A during electrolysis reaction, the order of RhB removal efficiency was changed: JP202 > Pt ${\fallingdotseq}$ Pb > BDD. The total generated oxidants ($H_2O_2$, $O_3$, free Cl, $ClO_2$) concentration of 4 electrodes was Pt (6.04 mg/W) > JP202 (4.81 mg/W) > Pb (3.61 mg/W) > BDD (1.54 mg/W), respectively. JP202 electrode was the best electrode among 4 electrodes from the point of view of performance and energy consumption. Regardless of the type of electrode, RNO removal of NaCl and KCl (chlorine type electrolyte) were higher than that of the $Na_2SO_4$ (sulfuric type electrolyte) RNO removal. Except BDD electrode, RhB degradation and creation tendency of oxidants such as $H_2O_2$, $O_3$, free Cl and $ClO_2$, found that do not match. RNO degradation tendency were considered a simple way to decide the method which is simple it will be able to determinate the electrode where the organic matter decomposition performance is superior. As the added NaCl concentration was increases, the of hydrogen peroxide and ozone concentration increases, and this was thought to increase the quantity of OH radical.

A Study on the Statistical Predictability of Drinking Water Qualities for Contamination Warning System (수질오염 감시체계 구축을 위한 수질 데이터의 통계적 예측 가능성 검토)

  • Park, No-Suk;Lee, Young-Joo;Chae, Seonha;Yoon, Sukmin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.469-479
    • /
    • 2015
  • This study have been conducted to analyze the feasibility of establishing Contamination Warning System(CWS) that is capable of monitoring early natural or intentional water quality accidents, and providing active and quick responses for domestic C_water supply system. In order to evaluate the water quality data set, pH, turbidity and free residual chlorine concentration data were collected and each statistical value(mean, variation, range) was calculated, then the seasonal variability of those were analyzed using the independent t-test. From the results of analyzing the distribution of outliers in the measurement data using a high-pass filter, it could be confirmed that a lot of lower outliers appeared due to data missing. In addition, linear filter model based on autoregressive model(AR(1) and AR(2)) was applied for the state estimation of each water quality data set. From the results of analyzing the variability of the autocorrelation coefficient structure according to the change of window size(6hours~48hours), at least the window size longer than 12hours should be necessary for estimating the state of water quality data satisfactorily.

Effects of Adulterants in HCl on Artificial Hatching in the Silkworm Eggs (염산의 협잡물이 잠종의 인공부화에 미치는 영향)

  • 김윤식;김락상
    • Journal of Sericultural and Entomological Science
    • /
    • v.17 no.1
    • /
    • pp.35-39
    • /
    • 1975
  • The acid treatment hatching method has been used practically for about 60 years and a number of investigators have studied about the artificial hatching for silkworm e99s, but the basic theory about the acid treatment hatching is not clarified yet. It is no exaggeration to say that the accidents of non hatching is continued ceaselessly in the silkworm egg by hydrochloric acid treatment. It is believed that the accident is due to the adulterants in HCl lather than inattention of acid treatment. Therefore, the authors mixed hydrochloric acid (analytical grade) with or added it to chemical ingredients which are possible to be included in the process of hydrochloric acid production, and treated it to summer and fall silkworm egg. The metalic adulterants such as iron, mercury, lead and arsenic are appeared not to be worried, but damage of SO$_3$ and free chlorine is seemed to lie considerable. Therefore, before acid treatment for hatching hydrochloric acid was warmed to 50$^{\circ}C$ with shaking to evaporate several injurious gases, by whick the damage due to use of hydrochloric acid for acid treatment hatching is prevented considerably. In conclusion, it is recommended to pretest bioassay with every HCl samples before artificial hatching of silkworm egg.

  • PDF

Peroxone ($O_3/H_2O_2$) Process in Drinking Water Treatment (정수처리에서의 Peroxone ($O_3/H_2O_2$) 공정)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Bin, Jae-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.3
    • /
    • pp.296-308
    • /
    • 2010
  • The peroxone process overcomes many of the limitations associated with conventional and advanced water treatment systems using chlorine disinfection and ozone oxidation processes. Ozone and hydrogen peroxide generate highly reactive hydroxyl free radical which oxidize various organic compounds and has highly removal efficiency. The key issue to operate peroxone process is developing the method to achieve high process effectiveness when scavengers that inhibit generation of OH radicals or consume OH radicals are co-existing in the process. Also many studies, to minimize inorganic oxidative by-products such as bromate and to reduce disinfection by-products after chlorination behind peroxone process, are needed. And we should consider the excess residual hydrogen peroxide in the water. On-line instruments and control strategies need to be developed to ensure effective and robust operation under conditions of varying load. If problems above mentioned are solved, peroxone process will be applied diversely for water treatment.

A Study on the Preparation of the Dimensionally Stable Anode(DSA) with High Generation Rate of Oxidants(II) (산화제 생성율이 높은 촉매성 산화물 전극(DSA)의 개발에 관한 연구(II))

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.18 no.1
    • /
    • pp.61-72
    • /
    • 2009
  • Fabrication and oxidants production of 3 or 4 components metal oxide electrode, which is known to be so effective to destruct non-biodegradable organics in wastewater, were studied. Five electrode materials (Ru as main component and Pt, Sn, Sb and Gd as minor components) were used for the 3 or 4 components electrode. The metal oxide electrode was prepared by coating the electrode material on the surface of the titanium mesh and then thermal oxidation at $500^{\circ}C$ for 1h. The removed RhB per 2 min and unit W of 3 components electrode was in the order: Ru:Sn:Sb=9:1:1 > Ru:Pt:Gd=5:5:1 > Ru:Sn=9:1 > Ru:Sn:Gd=9:1:1 > Ru:Sb:Gd=9:1:1. Although RhB decolorization of Ru:Sn:Sb:Gd electrode was the highest among the 4 components electrode, the RhB decolorization and oxidants formation of the Ru:Sn:Sb=9:1:1 electrode was higher than that of the 3 and 4 components electrode. Electrogenerated oxidants (free Cl and $ClO_2$) of chlorine type in 3 and 4 components electrode were higher than other oxidants such as $H_2O_2\;and\;O_3$. It was assumed that electrode with high RhB decolorization showed high oxidant generation and COD removal efficiency. OH radical which is electrogenerated by the direct electrolysis was not generated the entire 3 and 4 components electrode, therefore main mechanism of RhB degradation by metal oxide electrode based Ru was considered indirect electrolysis using electrogenerated oxidants.

A Study on the Analysis of Well-water in a Suburban Area in Taegu City (대구시(大邱市) 일부지역(一部地域) 우물물의 위생학적(衛生學的) 고찰(考察))

  • Yeo, Woon-Chae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.2
    • /
    • pp.327-332
    • /
    • 1974
  • Wells are perticularly able to be a source of water-borne infections disease in the army society. Owing to untreated drinking water, high indidence of water-borne diseases are encounted in Korea. This study was carried out to evaluate the physicochemical and bacteriological states of 298 wells in army camps around Daegu city during a year from January to November, 1974. Main findings are summerized as follows: 1. Turbidity, Colorness & odor was within normal range in all samples. 2. Reaction of pH, cnsumption of KMnO4, total hardness and chlorine ion as over almost within normal range. 3. Free Ammonia was detected to 33.2% positive, and nitrite, 45.5% positive. 4. In the bacteriological test 40.3% of all samples were over the standard limit on E. Coli. 5. In comparison of nitrate and E. Coli detection, 60.1% of nitrite was over the standard limit out of the positive cases detected E. Coli. and all of E. Coli were over the standard limit out of the positive cases of nitrite. 6. The contamination was very remarkable in the spring and summer, and very diminished in the autumn and winter.

  • PDF

Inactivation of various bacteriophages in wastewater by chlorination; Development of more reliable bacteriophage indicator systems for water reuse (하수 처리 과정의 염소 소독에 대한 여러 박테리오파지들의 저항성 평가; 물 재이용 과정의 안전성 관리를 위한 바이러스 지표미생물의 개발)

  • Bae, Kyung-Seon;Shin, Gwy-Am
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.285-291
    • /
    • 2016
  • There has been an accelerating increase in water reuse due to growing world population, rapid urbanization, and increasing scarcity of water resources. However, it is well recognized that water reuse practice is associated with many human health and ecological risks due to numerous chemicals and pathogenic microorganisms. Especially, the potential transmission of infectious disease by hundreds of pathogenic viruses in wastewater is one of the most serious human health risks associated with water reuse. In this study, we determined the response of different bacteriophages representing various bacteriophage groups to chlorination in real wastewater in order to identify a more reliable bacteriophage indicator system for chlorination in wastewater. Different bacteriophages were spiked into secondary effluents from wastewater plants from three different geographic areas, and then subjected to various doses of free chlorine and contact time at $5^{\circ}C$ in a bench-scale batch disinfection system. The inactivation of ${\phi}X174$ was relatively rapid and reached ~4 log10 with a CT value of 5 mg/L*min. On the other hand, the inactivation of bacteriophage PRD1 and MS2 were much slower than the one for ${\phi}X174$ and only ~1 log10 inactivation was achieved by a CT value of 10 mg/L*min. Overall, the results of this study suggest that bacteriophage both MS2 and PRD1 could be a reliable indicator for human pathogenic viruses for chlorination in wastewater treatment processes and water reuse practice.

Preparation of Disulfonated Poly(arylene ether sulfone) Random Copolymer Thin Film Composite Membranes Using a Benign Solvent (친환경용매 기반의 술폰화 폴리아릴렌 에테르 술폰 랜덤 공중합체 Thin Film Composite 제조)

  • Lee, Chang Hyun;McGrath, James E.;Freeman, Benny
    • Membrane Journal
    • /
    • v.24 no.4
    • /
    • pp.292-300
    • /
    • 2014
  • Chlorine-resistant sulfonated poly(arylene ether sulfone) random copolymer (SPAES)-thin film composite (TFC) membranes for desalination are prepared using monoglyme as a selective solvent, which dissolves SPAES, but should be inert to porous polysulfone layer (e.g., Udel$^{(R)}$). Different from formic acid and diethylene glycol used as other selective solvents, monoglyme is environmentally friendly and has much lower boiling temperature. After a pretreatment of Udel$^{(R)}$ support film in isopropyl alcohol-glycerine mixture to minimize pore penetration leading to fairly reduced water flux, coating of SPAES solution in monoglyme onto the support and stepwise drying processes are conducted for defect-free TFC formation. The transport behavior through SPAES-TFC membranes is observed, correlating with the effects of sulfonation level, protonation, and physical and chemical crosslinking of SPAES selective layers.

Effects of Turmeric (Curcuma longa L.) on Blood Glucose and Lipid Metabolism Functional Improvement in STZ-induced Diabetic rats (울금(Curcuma longa L.) 섭취가 당뇨성 흰쥐의 혈당 및 지질대사 기능 개선에 미치는 영향)

  • Oh, Da-Young;Kang, Dong-Soo;Lee, Young-Geun;Kim, Han-Soo
    • Journal of Environmental Science International
    • /
    • v.28 no.5
    • /
    • pp.485-494
    • /
    • 2019
  • The purpose of this study was to investigate the improvement effect of 5% turmeric (Curcuma longa L.) on the blood glucose and lipid metabolism function of streptozotocin (STZ, 45 mg/kg body weight)-induced diabetic rats. Seven-week-old male rats were divided into four groups (n=6), and fed experimental diets containing turmeric meal [basal diet+5% turmeric (BT), basal diet+STZ+5% turmeric (ST)], and control (BD), BS groups (basal diet+STZ). The results of this study, turmeric diet groups (BT, ST) in lipid component as evidenced from the significantly reduction of serum total cholesterol, low density lipoprotein-cholesterol (LDL-cholesterol), atherosclerotic index (AI), cardiac risk factor (CRF), triglyceride (TG), phospholipid (PL), free cholesterol, cholesteryl ester, uric acid, blood glucose, non esterified fatty acid (NEFA), and elevation of high density lipoprotein-cholesterol (HDL-cholesterol). The serum albumin and globulin contents were increased in turmeric supplementation diet than STZ-induced diabetic rats (p<0.05). Concentrations of sodium (Na) and chlorine (Cl) in sera were lower in the turmeric diet than diabetic group. Total calcium (T-Ca), phosphorus (Pi) and potassium (K) concentrations in sera were higher in the BT, ST and BD groups than BS group. In vivo experiments with Sprague-Dawley rats showed that ingestion of turmeric (Curcuma longa L.) were effective in the blood glucose and lipid metabolism functional improvement.

Physicochemical properties, cytotoxicity and penetration into dentinal tubules of sodium hypochlorite with and without surfactants

  • Hernan Coaguila-Llerena;Isadora Barbieri ;Mario Tanomaru-Filho ;Renato de Toledo Leonardo;Ana Paula Ramos ;Gisele Faria
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.47.1-47.11
    • /
    • 2020
  • Objectives: The aim of this study was to assess the physicochemical properties, cytotoxicity and penetration into dentinal tubules of ChlorCidTM Surf (3% sodium hypochlorite [NaOCl] with surfactant) in comparison to ChlorCidTM (3% NaOCl without surfactant). Materials and Methods: The physicochemical properties evaluated were pH, surface tension, free available chlorine (FAC) and contact angle. Cytotoxicity was evaluated in L929 fibroblasts exposed to the solutions by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide and neutral red assays. Assessment of penetration into dentinal tubules was performed by staining single-rooted permanent human teeth with crystal violet (n = 9), which were irrigated with the solutions and analyzed in cervical, middle and apical segments. Data were analyzed by one-way analysis of variance (ANOVA) and Tukey's post-test, 2-way ANOVA and Bonferroni's post-test or t-test (α = 0.05). Results: ChlorCidTM Surf and ChlorCidTM FAC values were close to those indicated by the manufacturer. ChlorCidTM Surf showed lower surface tension and contact angle on dentin, and higher pH than ChlorCidTM (p < 0.05). The penetration of ChlorCidTM Surf was higher in cervical and middle segments, compared with ChlorCidTM (p < 0.05). There was no difference in irrigant cytotoxicity (p > 0.05). Conclusions: ChlorCidTM Surf showed lower surface tension, lower contact angle on root canal dentin, higher penetration into dentinal tubules and more alkaline pH, compared with ChlorCidTM. However, both solutions showed similar cytotoxicity and FAC content.