• 제목/요약/키워드: Free Drop

검색결과 255건 처리시간 0.027초

Numerical estimation of errors in drop angle during drop tests of IP-Type metallic transport containers for radioactive materials

  • Lim, Jongmin;Yang, Yun Young;Lee, Ju-chan
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1878-1886
    • /
    • 2021
  • For industrial package (IP)-type transport containers for radioactive materials, a free drop test should be conducted under regulatory conditions. Owing to various uncertainties observed during the drop test, errors in drop angles inevitably occur. In IP-type metal transport containers in which the container directly impacts onto a rigid target without any shock absorbing materials, the error in the drop angle due to a slight misalignment makes a significant difference from the ideal drop. In particular, in a vertical drop, the error in the drop angle causes a strong secondary impact. In this paper, a numerical method is proposed to estimate the error in the drop angle occurring during the test. To determine this error, an optimization method accompanying a computational drop analysis is proposed, and a surrogate model is introduced to ensure calculation efficiency. Effectiveness of the proposed method is validated by performing the verification and comparison between the test and the analysis applied with the drop angle error.

저중력 환경 모사를 위한 낙하 시험 방법 연구 (Investigation of Drop Test Method for Simulation of Low Gravity Environment)

  • 백승환;유이상;신재현;박광근;정영석;조기주;오승협
    • 한국추진공학회지
    • /
    • 제25권4호
    • /
    • pp.78-87
    • /
    • 2021
  • KSLV 상단의 임무 다각화를 위해서는 저중력 환경에서 액체 추진제의 거동을 정확히 파악하고 있어야 한다. 지상에서 저중력 환경을 모사하는 방법은 자유낙하 방법이 있지만, 공기저항이 항상 동반된다. 공기 저항을 제거하기 위하여 공기 저항 차단캡슐을 이용한 낙하 시험을 진행하였다. 공기 저항 차단캡슐 내부에 시험체를 위치하고 7 m 높이에서 1.2초 동안 낙하하여 시험체의 저중력 환경을 조성하였다. 낙하하는 동안 0.01 g 이하의 중력가속도를 측정하였으며 지표면에 도달하기 전 최소 가속도는 약 0.005 g였다. 추후 낙하 높이 및 낙하 시간이 증가한다면 개선될 수 여지가 있다.

LS-DYNA3D 및 ABAQUS/Explicit Code를 이용한 사용후 핵연료 운반용기의 자유낙하 충격특성연구 (A Study on the Free Drop Impact Characteristics of Spent Nuclear Fuel Shipping Casks by LS-DYNA3D and ABAQUS/Explicit Code)

  • 최영진;김승중;김용재;이재형;이영신
    • 한국전산구조공학회논문집
    • /
    • 제18권1호
    • /
    • pp.43-49
    • /
    • 2005
  • 방사선물질을 수송하기 위한 용기는 가상 사고조건에서도 안전해야만 한다. 운반용기 설계요구조건은 실험 및 유한요소 해석을 통해 구조적 건전성을 확보하여야 한다. 최근에는 실험보다 유한요소해석을 이용한 방법이 상대적으로 비용이 적기 때문에 주로 사용된다. 그러나 기계적인 반응이 복잡하기 때문에 프로그램을 적용하는 사용자의 방법에 의해 결과가 결정되고 해석하는 동안 여러가지 문제를 발생시킬 수 있다. 본 논문에서, 유한요소해석은 LS-DYNA3D와 ABAQUS/Explicit을 이용하여 운반용기의 9m 자유낙하충격실험에 대한 해석기술과 여러가지 손상을 갖는 경우를 발견하기 위해 연구하였다. 운반용기의 각각의 경우를 비교하고 사용후 핵연료 운반용기의 낙하 실험에 대해서 신뢰할 수 있는 비교적 간단한 해석 기술을 제안하였다.

In Vitro Development of Porcine Parthenogenetic Embryos under the Oil-free Culture System

  • Park, Sang-Kyu;Choi, Young-Ju;Roh, Sang-Ho
    • 한국수정란이식학회지
    • /
    • 제25권4호
    • /
    • pp.259-262
    • /
    • 2010
  • Optimization of the preimplantation mammalian embryo culture condition was widely focused on refining medium composition under the name of chemically defined media. However, recent research revealed that the alteration of physical environment can be a crucial factor to a successful embryo development. In this study, under the same embryo density, a novel culture device named oil-free micro tube culture (MTC) system was evaluated using porcine parthenogenetic embryos. The activated oocytes were placed into the 0.2 ml thin-wall flat cap PCR tube and cultured to the blastocyst stage. As a preliminary step, embryo density and culture medium volume were optimized under a standard drop culture system. The optimal embryo density range for in vitro culture was 0.5 embryos per ${\mu}l$ in $20\;{\mu}l$ drop (20.5%) and 1.0 embryos per ${\mu}l$ in $10\;{\mu}l$ drop (20.6%). Based on these results, we compared drop culture system and 'MTC' system in terms of the developmental rate to the blastocyst stage. In $20\;{\mu}l$ medium volume, the 'MTC' system showed similar blastocyst formation rate when compared with drop culture system (20.2% versus 20.5%, respectively) while the 'MTC' system showed lower blastocyst formation rate than drop culture system in $10\;{\mu}l$ one (12.7% versus 20.0%, respectively). Therefore the $20\;{\mu}l$ MTC system may be an alternative incubation system for short-distance embryo transport without carrying the $CO_2$ incubator and this provides novel embryo culture device to clinical veterinary embryologists.

균일전기장에 의한 기포와 액적의 변형에 관한 연구 (A study on the deformation of a bubble and a drop in a uniform electric field)

  • 권영철;김무환;강인석;조혜정;김석준
    • 대한기계학회논문집B
    • /
    • 제20권6호
    • /
    • pp.2023-2035
    • /
    • 1996
  • In the present study, the characteristics of the electrical deformation of a bubble and a drop under a uniform electric field have been investigated to understand EHD heat transfer enhancement by an electric field. The deformation of the bubble and the drop have been studied theoretically using an electric normal stress acting on their interfaces and assured by the numerical analysis and the experiment. From the variation of bubble volume and free energy, it is found that a bubble is compressed in an electric field and free energy had larger value with increasing W and the permittivity of a dielectric fluid. The electric normal stress induced on the interface of the bubble and the drop is different. Because of the surface charge induced at the drop interface, the electric normal stress acting on the drop is much larger than that of the bubble. The drop is, therefore, deformed much more than the bubble. In addition, the experimental and numerical results show that the aspect ratio and the contact angle of the bubble increase with increasing W.

Influence of design modification of control rod assembly for Prototype Generation IV Sodium-cooled Fast Reactor on drop performance

  • Son, Jin Gwan;Lee, Jae Han;Kim, Hoe Woong;Kim, Sung Kyun;Kim, Jong Bum
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.922-929
    • /
    • 2019
  • This paper presents the drop performance test of the control rod assembly which is one of the main components strongly related to the safety of the prototype generation IV sodium-cooled fast reactor. To investigate the drop performance, a real-sized control rod assembly that was recently modified based on the drop analysis results was newly fabricated, and several free drop tests under different flow rate conditions were carried out. Then the results were compared with those obtained from the previous tests conducted on the conceptually designed control rod assembly to demonstrate the improvement in performance. Moreover, the drop performance tests under several types and magnitudes of seismic loadings were also conducted to investigate the effect of the seismic loading on the drop performance of the modified control rod assembly. The results showed that the effects of the type and magnitude of the seismic loading on the drop performance of the modified control rod assembly were not significant. Also, the drop time requirement was successfully satisfied, even under the seismic loading conditions.

MEMS 가속도계를 적용한 ELT 시스템 개발과 검증 (Development and Verification of ELT System Using the MEMS Accelerometer)

  • 이상철;이동규;강자영
    • 한국항공우주학회지
    • /
    • 제38권3호
    • /
    • pp.294-299
    • /
    • 2010
  • 비상위치송수신장치(ELT)는 항공기 추락 시 조난 신호를 송출하는 장비이다. 유용한 장비이지만 항공기 추락과 경착륙에 대한 오판으로 인하여 잘못된 조난신호를 송출하기도 한다. 이러한 문제점은 현재 사용되고 있는 기계식 G-스위치의 부정확성에 그 원인이 있다. ELT의 성능 개선을 위하여 기계식 G-스위치를 MEMS 가속도계로 대체한 ELT 시스템을 개발하였다. ELT 시스템은 가속도 정보 수집/분석 시스템과 추락 판단 프로그램, 추락 상황에서 위치 정보를 제공하기 위한 GPS 수신 시스템으로 구성되어 있다. 또한, ELT 시스템을 검증하기 위한 자유 낙하 실험대를 제작하였다. 자유 낙하 실험대는 추락과 경착륙에 해당하는 충격 가속도와 충격 유지 시간을 모사할 수 있도록 설계하였다. 자유 낙하 실험대를 이용하여 개발한 ELT 시스템이 정확히 작동함을 확인하였다.

Flow Characteristics in Nappe Flow over Stepped Drop Structure

  • Kim, Jin Hong;Woo, Hyo Seop
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.54-61
    • /
    • 2004
  • This paper deals with flow characteristics on the air entrainment and the energy dissipation in nappe flow over the stepped drop structure. Nappe flow occurred at low flow rates and for relatively large step height Dominant flow features include an air pocket, a free-falling nappe impact and a subsequent hydraulic jump on the downstream step. Air entrainment occurred from the step edge, through a free-falling nappe impact and a hydraulic jump. Most energy was dissipated by nappe impact and in the downstream hydraulic jump. It was related with the step height and the overflow depth, but not related with step slope. The stepped drop structure was found to be effcient for water treatment and energy dissipation associated with substantial air entrainment.

  • PDF

다중 OWC챔버 구조물의 운동해석 (A Study on the Multiple OWC Chamber Motion in Waves)

  • 홍도천;홍사영;홍석원
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.202-205
    • /
    • 2002
  • The motion of a floating body with multiple owe chambers in waves is studied taking account of fluctuating air pressure in the chambers. The atmospheric pressure drop in one chamber is interrelated with the drop in the other chamber. Velocity potential in the water due to the free surface oscillating pressure patches is calculated by making use of the hybrid Green integral equation. The chamber motion in the frequency domain is calculated for various values of parameters related to the atmospheric pressure drop in the multiple chambers.

  • PDF

유한요소해석과 낙하충격 실험을 통한 자동초점 액추에이터의 내충격 특성 향상 (Shock Resistance Characteristic of Auto Focus Actuator using Finite Element Method and Drop Impact Test)

  • 신민호;김효준;박규섭;김영주
    • 정보저장시스템학회논문집
    • /
    • 제9권2호
    • /
    • pp.56-61
    • /
    • 2013
  • The recent increased use of mobile phone has resulted in a technical focusing on reliability issues related to drop performance. Since mobile phone may be dropped several times during their use, it is required to survive common drop accidents. The plastic injection parts such as base stopper and carrier in the encoder type actuator can be broken easily in the actual reliability test of 1.5m free drop. So, we analyzed the shock resistance characteristics of auto focus actuator with variables in the material properties using finite element method. By applying the new resin materials, we can decrease the breakage of plastic injection parts and improve the reliability of mobile phone.