• Title/Summary/Keyword: Free & Health

Search Result 2,089, Processing Time 0.028 seconds

A Comparative Study on the Health Status and Life Satisfaction of Elders in Charged and Free Welfare Facilities (유료복지시설과 무료복지시설 입소 노인의 건강상태와 생활만족도 비교)

  • Kwon, Yun-Hee;Oh, Yun-Jung
    • Journal of Korean Public Health Nursing
    • /
    • v.23 no.1
    • /
    • pp.91-100
    • /
    • 2009
  • Objectives: The purpose of this study was to compare the health status and life satisfaction of elders in charged and free welfare facilities. Methods: The subjects of this study were selected among those without cognitive impairment from charged (124 persons) and free (126 persons) welfare facilities in D city. The data were analyzed using frequency analysis, $x^$ test, and t-test. Results: Subjective health status was significantly higher for the residents in the charged welfare facilities. The data collected indicated significantly higher scores for the residents at charged welfare facilities when questioned regarding the physical health status, sense, personal hygiene, excretion control and activity. The data collected indicated significantly higher scores for the residents at charged welfare facilities when questioned regarding the mental health status, recall of breakfast side dishes, awareness of dates, interests in daily matters, feelings of happiness, feelings of loneliness and depression. Life satisfaction was significantly higher for the residents at the charged welfare facilities. Conclusions: There were significant differences in health status and life satisfaction of elders in charged and free welfare facilities.

Inhalation toxicity study of H menthol (Nicotine free-tob acco free)herbal cigarettes

  • Jung, Ji-Won;Cho, Sung-Dae;Cho, Jong-Ho;Kim, Kyung-Bae;Lee, Ji-Hae;Ahn, Nam-Shik;Yang, Se-Ran;Park, Joon-Suk;Lee, Yong-Soon;Kang, Kyung-Sun
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 2002.05a
    • /
    • pp.216-216
    • /
    • 2002
  • Generally, tobacco smoking has noxious effects such as DNA damage, lung cancer induction, coronary artery disease. Nowadays, as concerns on health and longevity increases, a huge variety of products that aim to assist to quit smoking or reduce addictive symptoms such as nicotine patches are developed and manufactured with safely evaluation, but the safety of the most recent products of interest which do not contain tobacco and nicotine, and shape cigarettes is not evaluated and guaranteed relatively. In this study, we used H-menthol(nicotine free-tobacco fine) which are widely consumed through the world to evaluate the single and repeated dose inhalation toxicity and genotoxicity of H menthol (Nicotine free-tobacco free) herbal cigarettes provided by Cigastop Ltd. in ICR mice.

  • PDF

A Study on the Status of Indoor Smoking Rooms and Compliance with Indoor Smoke-free Policy in Some Public Facilities in the Seoul Metropolitan area and the Daegu and Gyeongsangbuk-do Province Area (수도권과 대구·경북지역의 일부 다중이용시설에서 흡연실 설치와 금연구역 정책 준수 수준 파악)

  • Yu, Da eun;Park, Ji Young;Lee, Kiyoung;Kim, Seung Won
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.78-86
    • /
    • 2021
  • Objectives: The purposes of this study were to investigate the installation rates and status of indoor smoking rooms in public facilities and to determine the level of compliance level with smoke-free policies in accordance with the National Health Promotion Act. Methods: A visiting survey was conducted on 1,206 public facilities in the Seoul Metropolitan Area and the Daegu and Gyeongsangbuk-do Province area. Researchers selected public facilities such as bars, coffee houses, and internet cafes using convenient sampling. They visited without prior notice, checked the existence of indoor smoking rooms, and recorded their status. Results: Internet cafes (110/116) had the highest installation rate of indoor smoking rooms, followed by bowling clubs (17/19) and billiard rooms (87/100). Depending on the type of business, 50-88% of smoking rooms were not completely enclosed. Coin karaoke rooms showed the least inadequacy in this regard. In addition, out of 512 smoking rooms, in 33% (n = 169) smoking indoors was observed in non-smoking areas. Only 9% of public facilities were in full compliance with the indoor smoke-free regulation. Conclusions: It was found that most of the public facilities with indoor smoking rooms did not comply with the smoke-free policy, and smoking was still observed inside some facilities. Therefore, there is a need for a policy that prohibits indoor smoking rooms completely.

Impact of the Smoke-free Law on Secondhand Smoke in Computer Game Rooms (금연정책 시행이 전국 PC방의 간접흡연에 미치는 영향)

  • Guak, Sooyoung;Lee, Kiyoung;Kim, Sungreol;Kim, Sungcheon;Yang, Wonho;Ha, Kwonchul
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.1
    • /
    • pp.11-16
    • /
    • 2015
  • Objectives: This study assessed the impact of the smoke-free law on secondhand smoke exposure in computer game rooms by measuring concentrations of particulate matter smaller than $2.5{\mu}m$($PM_{2.5}$). Methods: Indoor $PM_{2.5}$ concentrations were measured in 56 (during the smoke-free guidance period) and 118 computer game rooms (after the law went into effect) in four cities (Seoul, Cheonan, Daegu and Kunsan) in Korea. The number of smokers in the computer game rooms was also counted every five minutes. Results: Although a smoking ban had been implemented nationally, smoking was observed in 47% of the computer game rooms. Smoking density decreased from 1.62 persons per $100m^3$ during the guidance period to 0.32 persons per $100m^3$ after the smoke-free law. There is no statistically significant difference of $PM_{2.5}$ concentrations before and after the smoking ban. The $PM_{2.5}$ concentration was two times higher than the US NAAQS of $35{\mu}g/m^3$. The $PM_{2.5}$ concentration in computer game rooms without smokers was two times higher than the outdoor concentration. Conclusion: The smoke-free law in computer game rooms was complied with, even after the guidance period, in Korea. Indoor $PM_{2.5}$ concentration after smoke-free law implementation was high due to this non-compliance. High $PM_{2.5}$ concentration in computer game rooms without smokers might be due to smoking booths. The complete prohibition of smoking in computer game rooms should be implemented to protect patrons from secondhand smoke exposure.

The Medial Sural Artery Perforator Flap versus Other Free Flaps in Head and Neck Reconstruction: A Systematic Review

  • Yasser Al Omran;Ellie Evans;Chloe Jordan;Tiffanie-Marie Borg;Samar AlOmran;Sarvnaz Sepehripour;Mohammed Ali Akhavani
    • Archives of Plastic Surgery
    • /
    • v.50 no.3
    • /
    • pp.264-273
    • /
    • 2023
  • The medial sural artery perforator (MSAP) flap is a versatile fasciocutaneous flap, and yet is less commonly utilized than other free flaps in microvascular reconstructions of the head and neck. The aim is to conduct a high-quality Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA)- and Assessment of Multiple Systematic Reviews 2 (AMSTAR 2)-compliant systematic review comparing the use of the MSAP flap to other microvascular free flaps in the head and neck. Medline, Embase, and Web of Science databases were searched to identify all original comparative studies comparing patients undergoing head and neck reconstruction with an MSAP flap to the radial forearm free flap (RFFF) or anterolateral thigh (ALT) flap from inception to February 2021. Outcome studied were the recipient-site and donor-site morbidities as well as speech and swallow function. A total of 473 articles were identified from title and abstract review. Four studies met the inclusion criteria. Compared with the RFFF and the ALT flaps, the MSAP flap had more recipient-site complications (6.0 vs 10.4%) but less donor-site complications (20.2 vs 7.8%). The MSAP flap demonstrated better overall donor-site appearance and function than the RFFF and ALT flaps (p = 0.0006) but no statistical difference in speech and swallowing function following reconstruction (p = 0.28). Although higher quality studies reviewing the use of the MSAP flap to other free flaps are needed, the MSAP flap provides a viable and effective reconstructive option and should be strongly considered for reconstruction of head and neck defects.

Investigation of Dirofilaria immitis infection in dogs of Incheon area

  • Kim, Kyoung-Ho;Lee, Yun-Mi;Oh, Seung-Tae;Jeong, Cheol;Han, Tea-Ho;Lee, Sung-Mo
    • Korean Journal of Veterinary Service
    • /
    • v.32 no.4
    • /
    • pp.385-389
    • /
    • 2009
  • This study was attempted to survey on the prevalence of canine heartworm infection (Dirofilaria immitis) in the Incheon area in 2006. This study showed comparative infection rates of canine heartworm in conjunction with different geographic locations and rearing environments (i.e., indoor, outdoor or free roaming). In total, 24 dogs (6.0%) were D. immitis positive among a total of 400 tested dogs. The geographic distribution of detection rates was Nam-gu (2 dogs, 6.7%), Yeonsu-gu (1 dog, 3.0%), Namdonggu (5 dogs, 8.0%), Pupyoung-gu (4 dogs, 6.7%), Kanghwa-gun (8 dogs, 13.0%), and Onjin-gun (4 dogs, 11.1%). In addition, 4 dogs (2.0%) or 20 dogs (10.0%) were positive for D. immitis among 202 indoor dogs or 198 outdoor dogs including free roaming dogs, respectively, while 13 dogs (11.7%) were positive for D. immitis among 111 outdoor dogs excluding free roaming dogs. In the case of 87 free roaming dogs, 7 dogs (8.1%) among them were positive for D. immitis.

Comparison of PM2.5 Concentrations before and after Smoke-free Policy in Some Indoor Sports Facilities in Seoul (겨울철 서울시 일부 실내스포츠시설에서 금연정책 실시 전후 PM2.5 농도 비교)

  • Kim, Yoonjee;Lee, Kiyoung;Kim, Seung Won
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.267-274
    • /
    • 2018
  • Objectives: This study examined the impact of a smoke-free policy on indoor air quality at indoor recreation facilities by assessing $PM_{2.5}$ concentrations before and after the implementation of the new policy. Methods: Using real-time monitors, $PM_{2.5}$ concentrations were measured in 50 billiard rooms and 50 golf simulator rooms in Seoul, Korea. The characteristics of the indoor recreation facilities, smoking status, and atmospheric conditions were recorded at the same time.After the enforcement of a smoke-free policy, $PM_{2.5}$ concentrations, installation of smoking room, and smoking status were examined when the facilities were revisited. Results: Almost a half of the billiard rooms and over 80% of golf simulator rooms were located underground. Seventy percent of the billiard rooms and one hundred percent of the golf simulator rooms were equipped with a local exhaust ventilation system. After the implementation of the smoke-free policy, 46% of the billiard rooms and 20% of the golf simulator rooms newly installed a smoking room. In the billiard rooms with a newly-installed smoking room, the $PM_{2.5}$ concentrations decreased from 97.9 to $45.6{\mu}g/m^3$ after the implementation of the smoke-free policy. The same change of 29.0 to $ 26.3{\mu}g/m^3$ was not statistically significant in golf simulator rooms. Indoor $PM_{2.5}$ concentrations were correlated with outdoor $PM_{2.5}$ concentrations, number of smokers, and number of people in the room. Conclusions: The smoke-free policy for indoor recreation facilities was not effective at making the indoor spaces free from second hand smoke. Although a few billiard rooms installed a smoking room, indoor $PM_{2.5}$ concentrations were still higher than those of outdoor $PM_{2.5}$ or atmospheric $PM_{2.5}$. Stricter enforcement of the smoke-free policy should be achieved to prevent secondhand smoke exposure.

Second-Hand Smoke in Public Spaces: How Effective has Partial Smoke-Free Legislation Been in Malaysia?

  • Abidin, Emilia Zainal;Hashim, Zailina;Semple, Sean
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6845-6850
    • /
    • 2013
  • Background: This study was performed to gather data on second-hand smoke (SHS) concentrations in a range of public venues following the implementation of partial Smoke-Free Legislation in Malaysia in 2004. Materials and Methods: $PM_{2.5}$ was measured as a marker of SHS levels in a total of 61 restaurants, entertainment centres, internet caf$\acute{e}$s and pubs in Kuala Lumpur, Malaysia. Results: Under the current smoke-free laws smoking was prohibited in 42 of the 61 premises. Active smoking was observed in nearly one-third (n=12) of these. For premises where smoking was prohibited and no active smoking observed, the mean (standard deviation) indoor $PM_{2.5}$ concentration was 33.4 (23.8) ${\mu}g/m^3$ compared to 187.1 (135.1) ${\mu}g/m^3$ in premises where smoking was observed The highest mean $PM_{2.5}$ was observed in pubs [361.5 (199.3) ${\mu}g/m^3$]. Conclusions: This study provides evidence of high levels of SHS across a range of hospitality venues, including about one-third of those where smoking is prohibited, despite 8 years of smoke-free legislation. Compliance with the legislation appeared to be particularly poor in entertainment centres and internet caf$\acute{e}$s. Workers and non-smoking patrons continue to be exposed to high concentrations of SHS within the hospitality industry in Malaysia and there is an urgent need for increased enforcement of existing legislation and consideration of more comprehensive laws to protect health.

Changes in Antioxidant Enzymes, According to Recovery Methods During Repeated Apnea Diving

  • MOON, Hwang-woon;SONG, Youn-sang;KIM, Jeong-Weon
    • The Korean Journal of Food & Health Convergence
    • /
    • v.7 no.4
    • /
    • pp.23-29
    • /
    • 2021
  • This study analyzes the physiological changes that occur after free diving and studies peroxidants and antioxidants according to the recovery method. Accordingly, the purpose of this study is to provide proper rest methods after free diving and provide basic data for free diving research. Eight male college students recovered for 30 minutes after 20 free injections at a 5-meter diving site, 20 free injections after a week's car wash, and recovered for 30 minutes after collecting blood during recovery to analyze the effects of peroxidants and antioxidants. Comparison of changes in peroxidants and antioxidants in recovery methods after free-diving iterations showed that SOD tended to decrease immediately after free-diving, increasing MDA to 10 minutes after recovery, but no significant difference was found. The purpose of this study is to observe physiological changes according to the recovery method after free diving and to propose an appropriate recovery method after free diving. However, there was no significant difference in all the restoration methods, and 20 freediving was not high kinetic intensity for the subjects, which is believed to have resulted in the following results. Therefore, it was discussed that the repetitive diving strength should be higher to confirm a significant difference in the recovery method after free diving.

Investigation of canine dirofilariasis and brucellosis in free roaming dogs from public animal shelters in Gwangju area (광주지역 동물보호소내 유기견의 개심장사상충과 개 브루셀라병 감염 실태조사)

  • Koh, Ba-Ra-Da;Na, Ho-Myung;Jang, Mi-Sun;Kim, Ji-Yeon;Park, Seong-Do
    • Korean Journal of Veterinary Service
    • /
    • v.30 no.1
    • /
    • pp.155-164
    • /
    • 2007
  • This study was conducted to investigate the prevalence of canine heartworm infections, canine brucellosis and hematologic values from 153 free roaming dogs in the area of Gwangju city from March to November 2006. Nineteen (12.4%) of 153 samples tested with modified Knott's technique showed positive reaction for microfilariae. Polymerase chain reaction using specific primers for D immitis amplified the expected product from all samples of 19 microfilaremic canine blood samples as determined by the modified Knott's test for microfilariae. The seasonal infection rates of microfilariae were higher in the spring season (10/19, 52.6%) than in the other seasons. The major hematological findings in microfilaremic dogs were mild leukocytosis and mild monocytosis. A total of 100 dogs randomly selected from 153 free roaming dogs were negative for canine brucellosis by serological test using immunochromatographic antibody test kit.