• Title/Summary/Keyword: Fracture reduction

Search Result 1,060, Processing Time 0.031 seconds

Effect of Porosity on the High-Cycle Fatigue Behavior of Al-Si-Mg Casting Alloy (Al-Si-Mg계 주조용 알루미늄 합금의 고주기 피로 거동에 미치는 기공의 영향)

  • Lee, Young-Jae;Kang, Won-Guk;Euh, Kwang-Jun;Cho, Kyu-Sang;Lee, Kee-Ahn
    • Transactions of Materials Processing
    • /
    • v.18 no.4
    • /
    • pp.296-303
    • /
    • 2009
  • The effect of porosity on the high-cycle fatigue properties of Al-Si-Mg casting aluminum alloys was investigated in this study. Microstructure examination, tensile and high-cycle fatigue test were conducted on both Al-Si-Mg casted (F) and heat-treated (T6) conditions. Porosity characteristics on the fracture surfaces of fatigue-tested samples were examined using SEM and image analysis. The microstructure observation results showed that eutectic Si particles were homogeneously dispersed in the matrix of the Al-Si-Mg casting alloys, but there were porosities formed as cast defects. The high-cycle fatigue results indicated that the fatigue strength of the 356-T6 alloy was higher than that of the 356-F alloys because of the significant reduction in volume fraction of pores by heat treatment. The SEM fractography results showed that porosity affected detrimental effect on the fatigue life: 80% of all tested samples fractured as a result of porosity which acted as the main crack initiation site. It was found that fatigue life decreased as the size of the surface pore increased. A comparison was made between surface pore and inner pore for its effect on the fatigue behavior. The results showed that the fatigue strength with the inner pores was higher than that of the surface pore.

Size Effect of Compressive Strength of Concrete for the Non-standard Cylindrical Specimens (비표준형 실린더 공시체에 대한 콘크리트 압축강도의 크기효과)

  • 김진근;어석홍;이성태
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.1
    • /
    • pp.105-113
    • /
    • 1997
  • The reduction phenomena of concrete compressive strength with the size of cylinders have been very interested in, but till now the adequate. analysis technique is not fixed. Based on the existing research results. the bigger the member size is, the smaller the strengt.h is. However. the real test ~.csults reveal that the wduction rate becomes blunt and there are considerable differences between size offrct law and real results. The punposc. ofthis paper is to propose tho model equat.ion which covers the compressive strength of' cylinder specimens in case of general hight/dialnetcr ratio in terms of the size effect. he effect of maximum aggregate size on the microcrack zone was also studied, and the model equation was proposed by considering the concept of'the characteristic length. These results will also be used to predict the cornprcssivt. stxngth of various sized concrete cores sampled from existing structures.

An Evaluation of Aging Degradation Damage for Cr-Mo-V Steel by Electrochemical Potentiokinetic Reactivation Test (재활성화 분극시험에 의한 Cr-Mo-V강의 시효열화 손상 평가)

  • Kwon, Il-Hyun;Na, Sung-Hun;Song, Gee-Wook;Yu, Hyo-Sun
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.49-54
    • /
    • 2000
  • Cr-Mo-V steel is widely used as a material for the turbine structural component in fossil power plants. It is well known that this material shows the various material degradation phenomenons such as temper embrittlement, carbide coarsening. and softening etc. or ins to the severe operation conditions as high temperature and high pressure. These deteriorative factors cause tile change of mechanical properties as reduction of fracture toughness. Therefor it is necessary to evaluate tile extent of degradation damage for Cr-Mo-V steel in life assessment of turbine structural components. In this paper. the electrochemical potentiokinetic reactivation(EPR) test in $50wt%-Ca(NO_3)_2$ solution is performed to develop the newly technique for degradation damage evaluation of Cr-Mo-V steel. The results obtained from the EPR test are compared with those in small punch(SP) tests recommended by semi-nondestructive testing method using miniaturized specimen. The evaluation parameters used in EPR test are tile reactivation current density$(I_R)$ and charge$(Q_{RC})$ reactivation rate$(I_R/I_{Crit},\;Q_R/Q_{Crit})$. The results suggest that $I_R/I_{Crit}$ in these parameters shows a good correlation with SP test results.

  • PDF

Transient Inferior Subluxation of the Shoulder (견관절의 일과성 하방 아탈구)

  • Tae Suk-Kee;Jung Young Bok;Park Keun-Hyung;Song Kwang-Sup
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.167-174
    • /
    • 1998
  • Since the first description by Cotton, there have been sporadic reports about the inferior subluxation of the shoulder. Nevertheless there is still a lack of consensus regarding the mechanism of occurrence, evolution and treatment. We have experienced six cases of inferior sublusation(five cases after trauma and one case after surgery) which resolved over time. Analysis of the clinical informations including serial radiographs, data from clinical examination and electromyography(EMG) revealed the following results. All the five post-traumatic inferior subluxations were noted in women with an average age of 59 years after direct trauma resulting in fracture of the proxiaml hrnerus(4) or clavicle(1), of which nerve injury was proven by EMG in three. One case occurred after Bankart repair by stretch injury to the axillary nerve. The presenting symptom was unusually severe pain on passive motion. Absence of anterior or posterior displacement wasl confirmed by radiographs. All the cases seemed to have delayed onset of subluxation except one. The subluxed hu.meral head was concentrically reduced at an average 11 weeks(range 3-23 weeks) from the supposed time of occurrence and the acromiohumeral interval measUred on the standing anteroposterior radiographs decreased to 9.4 mm ftom 23 mm. Improvement of pain paralled the reduction. In conclusion, the most common cause of transient inferior subluxation was nerve injury in ou~ series and the prognosis was excellent, however protraction of recovery or leaving permanent subluxation would be possible if .the injured nerve is unrecoverable.

  • PDF

An Anterosuperior Deltoid Splitting Approach for Plate Fixation of Proximal Humeral Fractures

  • Shin, Dong-Ju;Byun, Young-Soo;Cho, Young-Ho;Park, Ki-Hong;Yoo, Hyun-Seong
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.1
    • /
    • pp.2-7
    • /
    • 2015
  • Background: The purpose of this study was to evaluate the usefulness and safety of the anterosuperior deltoid splitting approach for fixation of displaced proximal humeral fractures by analyzing the surgical outcomes. Methods: Twenty-three patients who could be followed-up for at least 8 months after the treatment of displaced proximal humeral fractures through the anterosuperior deltoid splitting approach were enrolled. We evaluated the reduction of the fractures and surgery-related complications at the last follow-up using X-ray results and clinical outcomes comprising the University of California at Los Angeles (UCLA) scoring system and the Korean Shoulder Society (KSS) score. Results: At the last follow-up of patients treated using the anterosuperior deltoid splitting approach for internal fixation of proximal humeral fractures, we found 22 cases (95.6%) of bone union, a mean UCLA score of 28.3 (range, 15 to 34) and a mean KSS score of 82.1 (range, 67 to 95). Various surgery-related complications were noted; a case of varus malunion after fracture displacement, a case of nonunion, a case of delayed union, two cases of impingement, and a case of partial axillary nerve injury, which recovered completely through the follow-up. Conclusions: Plate fixation using the anterosuperior deltoid splitting approach could be another reliable option for treating displaced proximal humeral fractures.

In Vivo Three-dimensional Evaluation of the Functional Length of Glenohumeral Ligaments

  • Goto, Akira;Sahara, Wataru;Koishi, Hayato;Yoshikawa, Hideki;Sugamoto, Kazuomi
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.174-174
    • /
    • 2009
  • The acromioclavicular-hook-plate is one of the surgical treatments for distal clavicle fracture and traumatic acromioclavicular (AC) joint dislocation. Although this procedure can obtain rigid and accurate anatomical reduction of the AC joint, secondary widening of the hook-hole in the acromion is often seen during postoperative follow-up. This complication is owing to the high-degree of mobility of the AC joint. Therefore, it is important to evaluate the effect on these complications due to the position of the hook-hole. The purpose of the present study is to investigate three-dimensionally the effect due to the position of the hook-hole during arm abduction motion. We studied in vivo and three-dimensional kinematics of the normal shoulder joint with use of a markerless bone-registration technique. Magnetic resonance images of 14 shoulders of 7 healthy volunteers were acquired in 7 positions between $0^{\circ}$ and $180^{\circ}$ of abduction. We created three-dimensional computer models of the bones and the acromioclavicular-hook-plate. Based on the three-dimensional kinematics data, we simulated the widening of the hook-hole each different positioning of the hook-hole. The widths of the hook-holes almost linearly increased. And these widths significantly increased, when we put the hook-hole on the acromion from AC joint to 20 mm and 25 mm posterior position.

  • PDF

문경지역 탄산온천수의 지구화학적 및 동위원소적 특성연구

  • 배대석;최현수;고용권;박맹언;정율필
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.87-90
    • /
    • 2000
  • The hydrogeochemical and isotopic studies on deep groundwater in the Munkyeong area, Kyeongbuk province were carried out. $CO_2$-rich groundwater (Ca-HC $O_3$ type) is characterized by low pH (5.8~6.5) and high TDS (up to 2,682 mg/L), while alkali groundwater (Na-HC $O_3$ type) shows a high pH (9.I~10.4) and relatively low TBS (72~116 mg/L). $CO_2$-rich water may have evolved by $CO_2$ added at depth during groundwater circulation. This process leads to the dissolution of surrounding rocks and Ca, Na, Mg, K and HC $O_3$ concentrations are enriched. The low Pc $o_2$ (10$^{-6.4}$atm) of alkali groundwaters seems to result from the dissolution of silicate minerals without a supply of $CO_2$. The $\delta$$^{18}$ O and $\delta$D values and tritium data indicate that two types of deep groundwater were both derived from pre-thermonuclear meteoric water. The carbon Isotope data show that dissolved carbon in the $CO_2$-rich water was possibly derived from deep-seated $CO_2$ gas. The $\delta$$^{18}$ S values of dissolved sulfate show that sulfate reduction occurred at great depths. The application of various chemical geothermometers on $CO_2$-rich groundwater shows that the calculated deep reservoir temperature is about 130~175$^{\circ}C$. Based on the geological setting, water chemistry and environmental isotope data, each of the two types of deep groundwater represent distinct hydrologic and hydrogeochemical evolution at depth and their movement is controlled by the local fracture system.m.

  • PDF

A Numerical Analysis: Effects of Hydraulic Characteristics of a Hazardous Zone on the Face Stability in Subsea Tunnelling (해저터널 시공중 문제구간의 수리적 특성이 막장의 안정성에 미치는 영향에 관한 수치해석적 연구)

  • Hong, Eun-Soo;Park, Eui-Seob;Shin, Hee-Soon;Kim, Hyung-Mok;Ryu, Dong-Woo
    • Tunnel and Underground Space
    • /
    • v.18 no.5
    • /
    • pp.366-374
    • /
    • 2008
  • Tunnelling under water table induces many geotechnical problems because of groundwater. In subsea tunneling, reduction of face stability can induce flooding in the vicinity of a fracture zone characterized by high permeability and high water pressure. In this study, the effects of high water pressure on the stability of a tunnel face in a limited zone with high permeability(hazardous zone) are analyzed. On the basis of the 'advance core' concept, the seepage force acting on a hypothetical cylinder ahead of a tunnel face is modeled. This study focuses on the hydraulic behavior of the ground ahead of the tunnel face by three-dimensional steady-state seepage analyses. The impact of the hazardous zone on the seepage force and stability of the tunnel face are simulated and analyzed. In light of the analysis results, it is estimated that the distance from the tunnel face to the exterior boundary limit, which the seepage force significantly affects the stability of the tunnel face, of a hypothetical cylinder is approximately 5 times the tunnel radii. Despite the restrictive assumptions of this study, the results are highly indicative regarding the risks of hazardous zones.

Vibration Mode and Durability Characteristics of Automotive IDS using Rotary Swaging Process for Incremental Forming (로터리 스웨이징 공정의 점진성형에 의한 중공 드라이브샤프트의 진동모드 및 내구특성)

  • Lim Seong-Joo;Lee Nak-Kyu;Lee Chi-Hwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.127-133
    • /
    • 2005
  • Rotary swaging is one of the incremental forming process which is a chipless process using the reduction of cross-sections of bars, tubes and wires. The TDS(Tube Drive Shaft) of monobloc used in automotive has been developed by the rotary swaging process. The mechanical characteristics of swaged parts such as the hardness, thickness and roughness are also estimated to conduct experimental analyses of rotary swaging process with the materials of 34Mn5 Furthermore the change in the vibration mode of TDS due to design parameters, which are the tube length, diameter and thickness, has been investigated and analysed. The weight of the TDS product is smaller by about $12.8\%$ than that of SDS with the same performance. It could be evidently found that the TDS is designed to be much lighter than SDS (Solid Drive Shaft). This advantage might give some possibility to improve the NVH (Noise-Vibration-Harshness) characteristics. A maximum torque and a total number of torsional repetitions for the TDS is checked and measured to know the torsional intensity and fatigue strength through the static torsion test and torsional durability test, respectively. A total number of the torsional repetitions up to the fracture for the TDS is greater than 250,000 times.

Traumatic Anterior Shoulder Dislocation in Patients Older than 60 Years of Age (60세 이상 환자에서 발생한 외상성 견관절 전방 탈구)

  • Ha, Jong-Kyoung;Yoo, Jae-Doo;Park, Sung-Pil;Shin, Sang-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.42-49
    • /
    • 2006
  • Purpose: This study evaluated clinical results, and recommended treatment protocol of traumatic anterior shoulder dislocation in the patients older than 60 years of age. Materials and Methods: Thirty-eight patients with first traumatic anterior shoulder dislocation aged over 60 years were included. The average age was 69.4 (range, 60 to 87 years). There were 8 men (average age of 71.6) and 30 women (average age of 69). Most common cause of injuries was a fall on the outstretched hand. The additional injuries were evaluated using MRI or CT arthrogram in the patients with significant pain and weakness while movements after 2 weeks sling immobilization. Results: Fifteen patients (39%) had rotator cuff tears and 5 patients (14%) had greater tuberosity fractures. The sizes of rotator cuff tears were diverse; 2 partial tears, 1 small tear, 4 medium tears, 3 large tears and 5 massive tears. Among 5 massive cuff tears, 3 patients revealed cuff arthropathy after reduction. 4 patients (11%) had recurrent dislocation more than one time during 1 month after the first dislocation. Bankart lesions revealed in 5 patients and three of them had associated rotator cuff tears. 3 out of 5 patients with Bankart lesions, 13 out of 15 patients with rotator cuff tears and 3 patients with displaced greater tuberosity fracture had operations. Conclusion: The injury mechanism of shoulder dislocation in patients older than 60 years of age seems to have either anterior or posterior mechanism. The diagnosis and treatment should be approached 2 weeks after dislocation.