• 제목/요약/키워드: Fracture reduction

검색결과 1,063건 처리시간 0.027초

오훼돌기 절제술에 의한 개구장애의 치료 (TREATMENT OF TRISMUS BY CORONOIDECTOMY)

  • 윤현중;이상화;박철홍
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제23권4호
    • /
    • pp.376-379
    • /
    • 2001
  • 본 교실에서는 외상에 의한 발생한 악안면 골절의 정복 후 오훼돌기와 관골 상악 복합체 후외측벽 사이의 기계적 간섭에 의해 발생한 2명의 개구장애 환자에서 호훼돌기 절제술과 하악운동에 대한 물리치료술 후 좋은 결과를 얻었기에 문헌고찰과 함께 보고하는 바이다.

  • PDF

Comparison Study of the Use of Absorbable Materials as Internal Splints with Airway Silicone Splint and Absorbable Materials as Internal Splints Alone

  • Ji, So Young;Kim, Seung Soo;Park, Ki Sung;Baik, Bong Soo
    • 대한두개안면성형외과학회지
    • /
    • 제17권4호
    • /
    • pp.202-205
    • /
    • 2016
  • Background: Packing after closed reduction of nasal fracture causes uncomfortable nasal obstruction in patients. We packed the superior meatus with synthetic polyurethane foam (SPF) to support the nasal bone, and packed the middle nasal meatus with a nasal airway splint (NAS) and SPF. The aim of this article is prospectively to compare the subjective patient discomfort of SPF (Nasopore Forte plus) packing alone and SPF with NAS. Methods: We compared the prospectively subjective patient discomfort of SPF packing alone (group A) and SPF with NAS (group B) via visual analog scale (VAS; 0, no symptom; 100, most severe symptom). Results: At first postoperative day group B showed significant lower scores in dry mouth, sleep disturbance, conversation difficulty. However at third postoperative day, VAS scores of each group had no statistically significant differences. Moreover at fifth postoperative day group A had statistically significant lower scores for nasal pain, dry mouth than the group B. Conclusion: Combination method of using NAS and SPF have some advantage on the patient comfort from first postoperative day to third postoperative day.

Hydrothermal Stability of (Y, Nb)-TZP/$Al_2O_3$ Composites

  • Lee, Deuk-Yong;Kim, Dae-Joon;Lee, Seung-Jae
    • The Korean Journal of Ceramics
    • /
    • 제5권4호
    • /
    • pp.371-374
    • /
    • 1999
  • Y2O3 and Nb2O5 co-doped tetragonal zirconia polycrystals((Y, Nb)-TZP) containing 10 to 30 vol% $Al_2O_3$ were prepared and hydrothermal stability of the composites was evaluated after aging for 5 h at the temperature range of $150^{\circ}C$ $250^{\circ}C$ under 4 MPa $H_2O$ vapor pressure in an autoclave. The (Y, Nb)-TZP/Al2O3 composites showed excellent phase stability under the hydrothermal conditions, as compared with the 3Y-TZP/$Al_2O_3$ composites, due to the combined effects of the Y-Nb ordering in the $t-ZrO_2$ lattice, the reduction of oxygen vacancy concentration, and the $Al_2O_3$ addition. The strength and fracture toughness of the (Y, Nb)-TZP/$Al_2O_3$ composite, containing 20 vol% of 2.8 $Al_2O_3$ particles, were 700 MPa and 8.1 MP.$am^{1/2}$, respectively.

  • PDF

냉간 가공된 316L 스테인리스 강의 저주기 피로 거동에 미치는 온도의 영향 (II) - 수명예측 및 파손 기구 - (The Influence of Temperature on Low Cycle Fatigue Behavior of Prior Cold Worked 316L Stainless Steel (II) - Life Prediction and Failure Mechanism -)

  • 홍성구;윤삼손;이순복
    • 대한기계학회논문집A
    • /
    • 제27권10호
    • /
    • pp.1676-1685
    • /
    • 2003
  • Tensile and low cycle fatigue tests on prior cold worked 3l6L stainless steel were carried out at various temperatures ftom room temperature to 650$^{\circ}C$. Fatigue resistance was decreased with increasing temperature and decreasing strain rate. Cyclic plastic deformation, creep, oxidation and interactions with each other are thought to be responsible for the reduction in fatigue resistance. Currently favored life prediction models were examined and it was found that it is important to select a proper life prediction parameter since stress-strain relation strongly depends on temperature. A phenomenological life prediction model was proposed to account for the influence of temperature on fatigue life and assessed by comparing with experimental result. LCF failure mechanism was investigated by observing fracture surfaces of LCF failed specimens with SEM.

W/O, W/S, O/W, MLV(Multilamellar Vesicles) TYPE에서 Retinyl Palmitate(RP)의 열적 안정성과 효능, 효과에 관한 연구 (The effect and stability of Retinyl Palmitate(RP) in W/O, W/S, O/W, MLV(Multilamellar Vesicles) cream)

  • 지홍근;서봉석
    • 대한화장품학회지
    • /
    • 제22권1호
    • /
    • pp.40-59
    • /
    • 1996
  • Retinol은 열과 빛에 쉽게 산화되기 때문에 그 유도체인 Retinyl Palmitate를 사용하고 있으나 이것 또한 안정성이 우려되어 많은 양을 사용하지 못하고 있다. 본 연구에서는 Retinyl Palmitate 5% 와 Tocopgeryl Acetate 10%를 함유한 W/O, W/S, O/W, MLV Type의 크림에서 열적 안정성 및 UV 안정성을 CHROMA METERS로 측정하였으며, $25^{\circ}C$, $45^{\circ}C$에서 RP의 함량을 HPLC로 정량 분석하였다. 또한 RP가 열, 빛 등에 의해서 어떤 물질로 변화하였는지를 측정하였으며, 변화된 물질의 독성에 대한 연구를 하였다. 각각의 크림 TYPE 마다 입자 SIZE를 측정했으며, DNA와 CHROMA METERS를 사용하여 CELLULAR RENEWAL을 측정하였다.

  • PDF

초음파 신호분석을 이용한 접착접합 이음의 파괴역학적 평가 (A Fracture Mechanics Approach to Adhesively Bonded Joint Using Ultrasonic Signal Analysis)

  • 한준영;오승규;윤송남;이원;장철섭;김민건;김환태
    • Journal of Welding and Joining
    • /
    • 제21권5호
    • /
    • pp.555-560
    • /
    • 2003
  • In automobile industry, it is necessary to reduce the weight from the view point of energy and environmental problems in these days. One of the ways for weight reduction is using adhesive aluminum structures. In this study, ultrasonic signals reflected from the adhesively bonded joint layer are used to evaluate the adhesively bonded joints. FFT is performed to determine bond-layer parameters such as effective thickness and frequency for adhesively bonded joint Al 6061 plates in comparison with the measured and theoretical ratios. And the parameters of ultrasonic wave and the J-integral are investigated to evaluate the adhesively bonded joint strength by DCB specimens.

Endotracheal Intubation Using Submandibular Approach for Maxillofacial Trauma Patients: Report of 2 Cases

  • Youn, Gap-Hee;Ryu, Sun-Youl;Oh, Hee-Kyun;Park, Hong-Ju;Jung, Seunggon;Jeong, Seongtae;Kook, Min-Suk
    • 대한치과마취과학회지
    • /
    • 제14권4호
    • /
    • pp.227-232
    • /
    • 2014
  • The indication for submandibular intubation is the requirement for intraoperative maxillomandibular fixation (MMF) in the presence of injuries that preclude nasotracheal intubation. Thus, We reported 2 cased of endotracheal intubations via submandibular approach that is applicable in patients with skull base fractures for a reliable general anesthesia. Endotracheal intubation via submandibular approach was applied during general anesthetic procedures for open reduction in three patients with Le Fort II, III or nasoorbitoethmoid (NOE) fractures. No complications due to submandibular intubation, such as infection, postoperative scarring, nerve injury, hematoma, bleeding, or orocutaneous fistula, were observed following submandibular intubation. Endotracheal intubation via submandibular approach is effective in patients with skull base fractures. In our method, the tube connector is removed in orotracheal intubation in order to avoiding the tube removal or displacement. The advantages of this method are very simple, safe, and to provide the good operation field.

Stress Analysis of Femoral Stems on Non-Cemented Total Hip Replacement - A Three-Dimensional Finite Element Analysis -

  • Kim, Sung-Kon;Chae, Soo-Won;Jeong, Jung-Hwan
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.263-266
    • /
    • 1997
  • Three dimensional numerical model based on the finite element method(FEM) were developed to predict the mechanical behavior of hip implants. The purpose of this study is to investigate the stress distribution of two types of cementless total hip replacement femoral component -a straight stem and a curved stem, and to compare their effect on the stress shielding between two types by three dimensional finite element method. The authors analyzed von Mises stress in the cortex & stem and compared the stress between the straight and the curved stem. In comparison of stresses between two different design of femoral stem, there was 25% more decrease of stress in straight stem than curved stem in the medial cortex at proximal region. The straight stem had consistently much lower stresses than the curved stem throughout the whole medial cortex with maximum 70% reduction of stress. However, there was little change in stress between nature and 2 implanted femur throughout the lateral cortex. Stress of femoral stem was much higher in the straight stem than the curved stem up to 60%. The straight stem had more chance of stress shielding and a risk of fatigue fracture of the stem compared with the curved stem in noncement hip arthroplasty. In design of femoral stem still we have to consider to develop design to distribute more even stress on the proximal medial cortex.

  • PDF

Si, Mn, V이 첨가된 비조질강의 미세조직 및 기계적 성질에 미치는 냉각속도의 영향 (Effect of Cooling Velocity on the Microstructures and Mechanical Properties of Si, Mn, V added HSLA Steels)

  • 박연서;최창수;정인상
    • 열처리공학회지
    • /
    • 제14권5호
    • /
    • pp.267-274
    • /
    • 2001
  • Microalloyed steels, which substituted by conventional quenched and tempered steels, have been used in a wide variety of structural and engineering application. The main driving force for preference of MA steels is a cost reduction which can be achieved by an omission of heat treatment. In this study, low carbon martensitic MA steels in 0.18C-0.30(0.60)Si-2.00(1.80)Mn-0.05S-1.5Cr-0.05(0.10)V-0.015Ti(wt%) were investigated to know the effects of cooling method on the mechanical properties and microstructures of Si, Mn, V added microalloyed steel at different reheating temperature. Microstructure of oil quenched steels which were comprised lath martensite, auto-tempered martensite and retained austenite, had more various structure than that of air cooled steel made of mainly bainite. Therefore, oil quenched steels, which had more various microstructure, had better strength-toughness balance compare to air cooled steels. In the impact test, fracture mode of oil quenched steels, which showed good mechanical properties, were dimple, but that of air cooled steels were cleavage.

  • PDF

기어 손상에 따른 진동 상태표시기 특성 평가 (Characteristics of Vibration Condition Indicator with Gear Tooth Damage)

  • 이동형;이웅용;문경호
    • 한국정밀공학회지
    • /
    • 제32권7호
    • /
    • pp.611-617
    • /
    • 2015
  • In the development of a vibration-based condition monitoring system in gearbox, one of the most important research topics is a quantitative analysis and test of the effect of gear damage on vibration of gearbox. This paper presents the evaluation result of vibration condition indicator according to the gear tooth damage through the vibration test of gearbox. The dynamic load test was performed with high speed railway (KTX)'s gearbox. The vibration of gearbox was measured according to a rotational speed change with the common gear fault modes, such as pitting and tooth breakage. The characteristics and the possibility of applying of vibration condition indicator on condition monitoring system were analyzed. As a result, the value of most condition indicator is gradually increased with the severity of gear faults. The NA6 indicator shows a low variation with the rotational speed change and high sensitivity in accordance with the gear fault.