• Title/Summary/Keyword: Fracture reduction

Search Result 1,050, Processing Time 0.027 seconds

Hydrothermal Stability of (Y, Nb)-TZP/$Al_2O_3$ Composites

  • Lee, Deuk-Yong;Kim, Dae-Joon;Lee, Seung-Jae
    • The Korean Journal of Ceramics
    • /
    • v.5 no.4
    • /
    • pp.371-374
    • /
    • 1999
  • Y2O3 and Nb2O5 co-doped tetragonal zirconia polycrystals((Y, Nb)-TZP) containing 10 to 30 vol% $Al_2O_3$ were prepared and hydrothermal stability of the composites was evaluated after aging for 5 h at the temperature range of $150^{\circ}C$ $250^{\circ}C$ under 4 MPa $H_2O$ vapor pressure in an autoclave. The (Y, Nb)-TZP/Al2O3 composites showed excellent phase stability under the hydrothermal conditions, as compared with the 3Y-TZP/$Al_2O_3$ composites, due to the combined effects of the Y-Nb ordering in the $t-ZrO_2$ lattice, the reduction of oxygen vacancy concentration, and the $Al_2O_3$ addition. The strength and fracture toughness of the (Y, Nb)-TZP/$Al_2O_3$ composite, containing 20 vol% of 2.8 $Al_2O_3$ particles, were 700 MPa and 8.1 MP.$am^{1/2}$, respectively.

  • PDF

The Influence of Temperature on Low Cycle Fatigue Behavior of Prior Cold Worked 316L Stainless Steel (II) - Life Prediction and Failure Mechanism - (냉간 가공된 316L 스테인리스 강의 저주기 피로 거동에 미치는 온도의 영향 (II) - 수명예측 및 파손 기구 -)

  • Hong, Seong-Gu;Yoon, Sam-Son;Lee, Soon-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1676-1685
    • /
    • 2003
  • Tensile and low cycle fatigue tests on prior cold worked 3l6L stainless steel were carried out at various temperatures ftom room temperature to 650$^{\circ}C$. Fatigue resistance was decreased with increasing temperature and decreasing strain rate. Cyclic plastic deformation, creep, oxidation and interactions with each other are thought to be responsible for the reduction in fatigue resistance. Currently favored life prediction models were examined and it was found that it is important to select a proper life prediction parameter since stress-strain relation strongly depends on temperature. A phenomenological life prediction model was proposed to account for the influence of temperature on fatigue life and assessed by comparing with experimental result. LCF failure mechanism was investigated by observing fracture surfaces of LCF failed specimens with SEM.

The effect and stability of Retinyl Palmitate(RP) in W/O, W/S, O/W, MLV(Multilamellar Vesicles) cream (W/O, W/S, O/W, MLV(Multilamellar Vesicles) TYPE에서 Retinyl Palmitate(RP)의 열적 안정성과 효능, 효과에 관한 연구)

  • 지홍근;서봉석
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.22 no.1
    • /
    • pp.40-59
    • /
    • 1996
  • Retinyl Palmitate, the skin normalzer, is useful to promote greater skin elasticity, to diminish lipid peroxidation and skin roughness following UV exposure, and promote a youthfull general skin appearance. We knew that the reduction of retinyl palmitate in W/O, W/S, O/W, MLV cream was caused by variable compound factors. Among the retinoids, we chose retinyl palmitate and studied the stability behavior of retinyl palmitate is liposomed. Furthermore, HPLC, CHROMA METERS, LASER SIGHT SCATTERING SYSTEM and FREEZE FRACTURE SCANNING ELECTROM MICROSCOPY was used to analyzing the stability and efficacy of UV and heat.

  • PDF

A Fracture Mechanics Approach to Adhesively Bonded Joint Using Ultrasonic Signal Analysis (초음파 신호분석을 이용한 접착접합 이음의 파괴역학적 평가)

  • Han, Jun-Young;Oh, Seung-Kyu;Yun, Song-Nam;Lee, Won;Jang, Chul-Sup;Kim, Min-Gun;Kim, Hwan-Tae
    • Journal of Welding and Joining
    • /
    • v.21 no.5
    • /
    • pp.555-560
    • /
    • 2003
  • In automobile industry, it is necessary to reduce the weight from the view point of energy and environmental problems in these days. One of the ways for weight reduction is using adhesive aluminum structures. In this study, ultrasonic signals reflected from the adhesively bonded joint layer are used to evaluate the adhesively bonded joints. FFT is performed to determine bond-layer parameters such as effective thickness and frequency for adhesively bonded joint Al 6061 plates in comparison with the measured and theoretical ratios. And the parameters of ultrasonic wave and the J-integral are investigated to evaluate the adhesively bonded joint strength by DCB specimens.

Endotracheal Intubation Using Submandibular Approach for Maxillofacial Trauma Patients: Report of 2 Cases

  • Youn, Gap-Hee;Ryu, Sun-Youl;Oh, Hee-Kyun;Park, Hong-Ju;Jung, Seunggon;Jeong, Seongtae;Kook, Min-Suk
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.4
    • /
    • pp.227-232
    • /
    • 2014
  • The indication for submandibular intubation is the requirement for intraoperative maxillomandibular fixation (MMF) in the presence of injuries that preclude nasotracheal intubation. Thus, We reported 2 cased of endotracheal intubations via submandibular approach that is applicable in patients with skull base fractures for a reliable general anesthesia. Endotracheal intubation via submandibular approach was applied during general anesthetic procedures for open reduction in three patients with Le Fort II, III or nasoorbitoethmoid (NOE) fractures. No complications due to submandibular intubation, such as infection, postoperative scarring, nerve injury, hematoma, bleeding, or orocutaneous fistula, were observed following submandibular intubation. Endotracheal intubation via submandibular approach is effective in patients with skull base fractures. In our method, the tube connector is removed in orotracheal intubation in order to avoiding the tube removal or displacement. The advantages of this method are very simple, safe, and to provide the good operation field.

Stress Analysis of Femoral Stems on Non-Cemented Total Hip Replacement - A Three-Dimensional Finite Element Analysis -

  • Kim, Sung-Kon;Chae, Soo-Won;Jeong, Jung-Hwan
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.263-266
    • /
    • 1997
  • Three dimensional numerical model based on the finite element method(FEM) were developed to predict the mechanical behavior of hip implants. The purpose of this study is to investigate the stress distribution of two types of cementless total hip replacement femoral component -a straight stem and a curved stem, and to compare their effect on the stress shielding between two types by three dimensional finite element method. The authors analyzed von Mises stress in the cortex & stem and compared the stress between the straight and the curved stem. In comparison of stresses between two different design of femoral stem, there was 25% more decrease of stress in straight stem than curved stem in the medial cortex at proximal region. The straight stem had consistently much lower stresses than the curved stem throughout the whole medial cortex with maximum 70% reduction of stress. However, there was little change in stress between nature and 2 implanted femur throughout the lateral cortex. Stress of femoral stem was much higher in the straight stem than the curved stem up to 60%. The straight stem had more chance of stress shielding and a risk of fatigue fracture of the stem compared with the curved stem in noncement hip arthroplasty. In design of femoral stem still we have to consider to develop design to distribute more even stress on the proximal medial cortex.

  • PDF

Effect of Cooling Velocity on the Microstructures and Mechanical Properties of Si, Mn, V added HSLA Steels (Si, Mn, V이 첨가된 비조질강의 미세조직 및 기계적 성질에 미치는 냉각속도의 영향)

  • Park, Yon-Seo;Choi, Chang-Soo;Chung, In-Sang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.5
    • /
    • pp.267-274
    • /
    • 2001
  • Microalloyed steels, which substituted by conventional quenched and tempered steels, have been used in a wide variety of structural and engineering application. The main driving force for preference of MA steels is a cost reduction which can be achieved by an omission of heat treatment. In this study, low carbon martensitic MA steels in 0.18C-0.30(0.60)Si-2.00(1.80)Mn-0.05S-1.5Cr-0.05(0.10)V-0.015Ti(wt%) were investigated to know the effects of cooling method on the mechanical properties and microstructures of Si, Mn, V added microalloyed steel at different reheating temperature. Microstructure of oil quenched steels which were comprised lath martensite, auto-tempered martensite and retained austenite, had more various structure than that of air cooled steel made of mainly bainite. Therefore, oil quenched steels, which had more various microstructure, had better strength-toughness balance compare to air cooled steels. In the impact test, fracture mode of oil quenched steels, which showed good mechanical properties, were dimple, but that of air cooled steels were cleavage.

  • PDF

Characteristics of Vibration Condition Indicator with Gear Tooth Damage (기어 손상에 따른 진동 상태표시기 특성 평가)

  • Lee, Dong-Hyung;Lee, Woong-Yong;Moon, Kyung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.611-617
    • /
    • 2015
  • In the development of a vibration-based condition monitoring system in gearbox, one of the most important research topics is a quantitative analysis and test of the effect of gear damage on vibration of gearbox. This paper presents the evaluation result of vibration condition indicator according to the gear tooth damage through the vibration test of gearbox. The dynamic load test was performed with high speed railway (KTX)'s gearbox. The vibration of gearbox was measured according to a rotational speed change with the common gear fault modes, such as pitting and tooth breakage. The characteristics and the possibility of applying of vibration condition indicator on condition monitoring system were analyzed. As a result, the value of most condition indicator is gradually increased with the severity of gear faults. The NA6 indicator shows a low variation with the rotational speed change and high sensitivity in accordance with the gear fault.

Design and stress analysis of femur bone implant with composite plates

  • Ramakrishna, S.;Pavani, B.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.5 no.1
    • /
    • pp.37-50
    • /
    • 2020
  • Development of lightweight implant plates are important to reduce the stress shielding effect for a prosthesis of femur bone fractures. Stainless steel (SS-316L) is a widely used material for making implants. Stress shielding effect and other issues arise due to the difference in mechanical properties of stainless steel when compared with bone. To overcome these issues, composite materials seem to be a better alternative solution. The comparison is made between two biocompatible composite materials, namely Ti-hydroxyapatite and Ti-polypropylene. "Titanium (Ti)" is fiber material while "hydroxyapatite" and "polypropylene" are matrix materials. These two composites have Young's modulus closer to the bone than stainless steel. Besides the variety of bones, present paper constrained to femur bone analysis only. Being heaviest and longest, the femur is the most likely to fail among all bone failures in human. Modelling of the femur bone, screws, implant and assembly was carried out using CATIA and static analysis was carried out using ANSYS. The femur bone assembly was analyzed for forces during daily activities. Ti-hydroxyapatite and Ti-polypropylene composite implants induced more stress in composite implant plate, results less stress induced in bone leading to a reduction in shielding effect than stainless steel implant plate thus ensuring safety and quick healing for the patient.

Processing of Nano-Sized Metal Alloy Dispersed $Al_2O_3$ Nanocomposites

  • Oh, Sung-Tag;Seok Namkung;Lee, Jai-Sung;Kim, Hyoung-Seop;Tohru Sekino
    • Journal of Powder Materials
    • /
    • v.8 no.3
    • /
    • pp.157-162
    • /
    • 2001
  • An optimum route to fabricate the ferrous alloy dispersed $Al_2O_3$ nanocomposites such as $Al_2O_3$/Fe-Ni and $Al_2O_3$/Fe-Co with sound microstructure and desired properties was investigated. The composites were fabricated by the sintering of powder mixtures of $Al_2O_3$ and nano-sized ferrous alloy, in which the alloy was prepared by solution-chemistry routes using metal nitrates powders and a subsequent hydorgen reduction process. Microstructural observation of reduced powder mixture revealed that the Fe-Ni or Fe-Co alloy particles of about 20 nm in size homogeneously surrounded $Al_2O_3$, forming nanocomposite powder. The sintered $Al_2O_3$/Fe-Ni composite showed the formation of Fe$Al_2O_4$ phase, while the reaction phases were not observed in $Al_2O_3$/Fe-Co composite. Hot-pressed $Al_2O_3$/Fe-Ni composite showed improved mechanical properties and magnetic response. The properties are discussed in terms of microstructural characteristics such as the distribution and size of alloy particles.

  • PDF