• Title/Summary/Keyword: Fracture reduction

Search Result 1,064, Processing Time 0.033 seconds

Effect of SiC Dispersion of $\beta$-Sialon Prepared from Wando Pyrophylite (완도납석으로부터 제조한 $\beta$-Sialon에 대한 SiC의 복합화 효과)

  • Lee, Hong-Lim;Kim, Shin;Lee, Hyung-Jik
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.3
    • /
    • pp.261-267
    • /
    • 1988
  • $\beta$-Sialon powder was prepared by the reduction-nitridation reaction from the mixture of Wando Pyrophyllite and carbon black at 135$0^{\circ}C$ in $N_2$ atmosphere. $\beta$-SiC powder was added to the prepared $\beta$-Sialon powder to make $\beta$-Sialon-SiC composite. The $\beta$-Sialon-SiC composites were sintered pressurelessly at 175$0^{\circ}C$ for 2h, using $Y_2O_3$ and $ZrO_2$(monoclinic) as sintering aids. Comparatively higher values of the fracture toughness (3.8 MN/㎥/2), M.O.R. (470 MN/$m^2$) and vickers microhardness (13.7 MN/$m^2$) were obtained when 10 wt% $Y_2O_3$ was added as a sintering aid. The improved fracture toughness and M.O.R. are assumed to be the results of crack deflection and crack branching by the second phase SiC particles.

  • PDF

Asymptotic Analysis for Hydraulic Fractures and Applicability of Boundary Collocation Method (수압파쇄균열의 점근적 해석과 경계병치법의 적용성)

  • Sim Young-Jong;kim Hong-Ta다
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.6
    • /
    • pp.93-100
    • /
    • 2005
  • The occurrence of multi-segmented hydraulic fractures that show different behavior from the single fracture is common phenomenon. However, it is not easy to evaluate the behavior of multiple fractures computed by most numerical techniques because of complicated process computation. This study presents how to efficiently calculate the displacement of the multi-segmented hydraulic fractures using the boundary collocation method (BCM). First of all, asymptotic solutions are obtained for the closely spaced overlapping fractures and are compared with those by the BCM where the number of collocation points is varied. As a result, the BCM provides an excellent agreement with the asymptotic solutions even when the number of collocation points is reduced ten times as many as that of conventional implementations. Accordingly, the numerical simulation of more realistic and, hence, more complex fracture geometries by the BCM would be valid with such a significant reduction of the number of collocation points.

The Effect of Graphite and MoS2 on Endurance and Cutting Performance of Diamond Micro Blades (다이아몬드 마이크로블레이드의 내구성과 절삭성능에 미치는 흑연과 MoS2의 첨가효과)

  • Moon, Jong-Chul;Kim, Song-Hee
    • Journal of Surface Science and Engineering
    • /
    • v.41 no.6
    • /
    • pp.335-340
    • /
    • 2008
  • Cutting performance and wear behavior were studied with the diamond micro-blade of Cu/Sn bond materials containing various amount of lubricant materials such as graphite and $MoS_2$. Measurement of instantaneous electric power consumption for cutting glass workpiece at the constant velocity was conducted and proposed as a method to assess cutting efficiency. The energy consumption of micro-blade for glass cutting decreased with the content of graphite and $MoS_2$ while wear amount of blade in volume increased with the amount of lubricant addition during the dicing test. It is because that hardness, flexural strength, and fracture toughness ($K_{IC}$) reduced with the amount of lubricant addition. Blades with $MoS_2$ additive showed higher mechanical properties than those with graphite additives when the same amount of the lubricant additive in wt.% was added. Due to the lower density of graphite than $MoS_2$, higher volume fraction of graphite could result in stronger effect on lowering electric power consumption by reducing the friction between blade and work piece however increasing wear rate due to the reduction in strength and fracture toughness. Adhesive wearing mode of micro blade could be remarkably improved by the addition of graphite as well as $MoS_2$.

Effectiveness of the ultrasonography in the evaluation following orbit wall reconstruction (안와벽 재건술 시행 후 평가방법으로서 초음파의 효용성)

  • Kim, Chang Yun;Yang, Jeong Yeol;Cheon, Ji Seon;Moon, Jae won
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.428-431
    • /
    • 2009
  • Purpose: Blow out fracture resulting from facial trauma is of high frequency among facial bone fractures, and can cause severe complications. So, proper management and close observation after operation are needed. So far, Computed tomography has been the best choice in the evalution following orbit wall reconstruction. However, cost - effectiveness, accessibility to patients and hazard of radiation exposure of computed tomography require supplementary measure for the evaluation following orbit wall reconstruction. This study was performed to describe the effectiveness of ultrasonography in the evalution following orbit wall reconstruction. Methods: A retrospective study was performed on 40 patients who underwent orbit wall reconstruction from June, 2008 to July, 2008. The patients' ages ranged from 13 to 65 years (mean 27.5 years), and this group was compsoed of 27 male and 13 female patients. The follow up period ranged from 2 weeks to 28 weeks (mean 11weeks). Preoperatively, all fractures were diagnosed using computed tomography. Ultrasonography for all cases, and computed tomography for 2 cases were performed for evaluation following orbit wall reconstruction. Results: Reduction of herniated orbital soft tissue and orbit implant was identified by using ultrasonography in 38 cases out of 40 cases. In other cases which we could not identify the orbit implant, computed tomography was performed. Con clusion: Compared to computed tomography, ultrasonography is simple, inexpensive and convenient method. Ultrasonography can be used as supplementary measure to computed tomography in the evaluation following orbit wall reconstruction for elective patients.

Simultaneous Surgery on Jejunum perforation with Pelvic Ring Fracture: A Case Report

  • Chung, HoeJeong;Bae, Keum-Seok;Kim, Seong-yup;Kim, Doosup
    • Journal of Trauma and Injury
    • /
    • v.29 no.2
    • /
    • pp.56-59
    • /
    • 2016
  • Patients with pelvic bone fractures with gastrointestinal perforations are reported in 4.4% of the cases and in very rare cases jejunum (0.15) is involved. However, intestinal perforations are often undiagnosed on the first examination before peritonitis is evident. We are presenting a report where a patient with anteroposterior compression injury, who was expected to undergo an internal fixation procedure, did not show any jejunum perforations on abdominal CT or other physical exams but was found on abdominal CT 1 week after right before surgery, therefore excision and anastomosis surgery, pelvic open reduction and internal fixation was simultaneously done with favorable results. In our case, we present a 61 year old male patient with liver trauma, adhesion at the abdominal cavity, with a past history of gallbladder excision, but without abdominal pain, fever, or infection symptoms. Therefore, this was a case that was difficult to initially diagnose the patient with jejunum perforation and peritonitis. The diagnosis was further supported during laparotomy when peritonitis around the area of intestinal perforation was observed. Generally, it is understood that pelvic bone fracture surgery is not immediately done on patients with peritonitis. However, this kind of patient who had peritonitis with intestinal adhesion and other complications could undergo surgery immediately as infection or other related symptoms did not coexist and the patient was rather stable, and as a result the treatment was successful.

The Incidence of Venous Thromboembolism Following Shoulder Surgery: A Pilot Study

  • Cho, Chul-Hyun;Jang, Hyung-Gyu;Park, Ui-Jun;Kim, Hyoung Tae
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.1
    • /
    • pp.18-23
    • /
    • 2017
  • Background: To assess the incidence of venous thromboembolism (VTE) following shoulder surgery and to evaluate the role of postoperative duplex ultrasonography. Methods: The study comprised a total of 224 patients who underwent shoulder surgery, including 180 shoulder arthroscopic surgeries, 28 shoulder arthroplasties, and 16 plate fixations for proximal humerus fracture between January 2014 and December 2014. The mean age of patients was 59.0 years, and there were 81 men and 143 women. Clinical data, including body mass index, blood tests, metabolic work-up for liver and renal function, previous, and present medical history, were evaluated. Duplex ultrasonography in the operative arm was performed on 2 to 4 days after surgery. Results: The overall incidence of VTE following shoulder surgery was 0.45% (1/224). One patient with open reduction and plate fixation for proximal humerus fracture had asymptomatic deep vein thrombosis that showed complete remission after anticoagulant medication during a 2-month period. Four patients had asymptomatic superficial cephalic vein thrombosis and complete remission without any treatment. There was no case of pulmonary embolism. Conclusions: The incidence of VTE following shoulder surgery was extremely low in Asians. Duplex ultrasonography may be not considered a routine follow-up of shoulder surgery and can be selectively performed in high-risk or symptomatic patients for VTE.

Comparison between minimally invasive plate osteosynthesis and the deltopectoral approach with allogenous fibular bone graft in proximal humeral fractures

  • Kim, Joon Yub;Lee, Jinho;Kim, Seong-Hun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.136-143
    • /
    • 2020
  • Background: The purpose of this study was to investigate the clinical differences between open reduction and plate fixation via a deltopectoral approach with allogenous fibular bone graft and a minimally invasive plate osteosynthesis (MIPO), in Neer's classification two-, threepart proximal humeral fractures. Methods: In this retrospective study, 77 patients with two-, three-part proximal humeral fractures were treated at two different institutions. Clinical and radiological evaluations were performed in 39 patients, who underwent MIPO at one institution (group A), and 38 patients, who underwent a deltopectoral approach with allo-fibular bone graft (group B) at another institution. The results between the groups were compared. Results: The MIPO technique was significantly less time consuming and caused less bleeding than the deltopectoral approach with allo-fibular bone graft (P<0.05). The duration of the fracture union was significantly reduced in group A (14.5±3.4; range, 10-22 weeks) compared to group B (16.4±4.3; range, 12-28) weeks (P<0.05). There were no statistically significant differences between the two groups when evaluating the visual analog scale and Constant scores between the two groups, 1 year postoperatively. In radiological evaluation, there was no difference in radiological outcomes between the two groups. There were no statistically significant differences in malunion between the two groups. Conclusions: The MIPO technique and deltopectoral approach with allo-fibular bone graft for two-, three-part proximal humeral fractures, show similar clinical and radiological results. However, allogenous fibular grafts require longer surgery, cause more bleeding, and result in longer fracture healing time than MIPO technique.

Transposition Lateral Arm Flap for Coverage of the Elbow Defects (전이형 외측 상완 피판술을 이용한 주관절 연부조직 결손의 피복)

  • Song, Joo-Hyoun;Lee, Yoon-Min;Lee, Joo-Yup
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.2
    • /
    • pp.82-86
    • /
    • 2008
  • Purpose: Soft tissue defect can occur on the posterior aspect of the elbow after trauma or fracture fixation. To cover the defect and maintain elbow functions, various flap surgeries including latissimus dorsi muscle flap, lateral arm flap and radial forearm flap can be performed. We present the clinical results of transposition lateral arm flap for coverage of the elbow defect and discuss the cause of posterior soft tissue necrosis after fracture fixation. Materials and Methods: Two patients who had posterior soft tissue defect of the elbow after open reduction of the fractures around the elbow were treated with transposition lateral arm flap. The mean size of skin defect was 20 $cm^2$. The flap was elevated with posterior radial collateral artery pedicle and transposed to the defect area. Donor defect was covered with split thickness skin graft. The elbow was immobilized for 1 week in extended position and active range of motion was permitted. Results: All two cases of transposition lateral arm flap survived without marginal necrosis. The average range of motion of the elbow was 10~115 degrees. Mayo elbow performance score was 72 and Korean DASH score was 23. Conclusion: When elbow fractures are fixed with three simultaneous plates and screws, skin necrosis can occur on the posterior aspect of the elbow around olecranon area. If the size of skin defect is relatively small, transposition lateral arm flap is very useful option for orthopaedic surgeons without microsurgical technique.

  • PDF

Effect of Heat Treatment on Microstructure and Mechanical Properties of an Fe-6.5Mn-0.08C Medium-Manganese Steel (열처리에 따른 Fe-6.5Mn-0.08C 중망간강의 미세조직과 기계적 특성)

  • Yoon, Young-Chul;Lee, Sang-In;Hwang, Byoungchul
    • Korean Journal of Materials Research
    • /
    • v.30 no.1
    • /
    • pp.8-13
    • /
    • 2020
  • Effect of heat treatment on microstructure and mechanical properties of an Fe-6.5Mn-0.08C medium-manganese steel is investigated in this study. Three kinds of medium-manganese steel specimens are fabricated by varying heat treatments of intermediate quenching (IQ), step quenching (SQ), and intercritical annealing (IA). Hardness and tensile tests are performed to examine the correlation of microstructure and mechanical properties for the Fe-6.5Mn-0.08C medium-manganese steel specimens. The IQ and SQ specimens have microstructures of martensite matrix with ferrite, whereas IA specimen exhibits microstructure of acicular ferrite matrix with martensite. The tensile test results show that the SQ specimen with martensite matrix has the highest yield strength and the lowest elongation. On the other hand, the SQ specimen has the highest hardness due to the relatively lower reduction of carbon content in martensite during intercritical annealing. According to the fractography of tensile tested specimens, the SQ specimen exhibits a dimple and quasi-cleavage fracture appearance while the IQ and IA specimens have fully ductile fracture appearance with fine-sized dimples caused by microvoid coalescence at ferrite and martensite interface.

Characteristics of Microwelded BLU CCFL Electrode in Terms of Glass Beading Heat Treatment Temperature (미세 용접된 BLU CCFL 전극의 유리비딩 열처리 온도에 따른 접합부 특성)

  • Kim, Gwang-Soo;Kim, Sang-Duck;Kwon, Hyuk-Dong
    • Journal of Welding and Joining
    • /
    • v.27 no.4
    • /
    • pp.73-78
    • /
    • 2009
  • Characterization of the microweld CCFL electrode for the TFT-LCD backlight unit was carried out in terms of the glass beading heat treatment conditions. We evaluate the weld zone and parent metal of the microweld CCFL electrodes that were exposed to simulated glass beading heat treatment. The CCFL electrode was composed of the cup made with pure Ni, the pin made with pure Mo and the lead wire made with Ni-Mn alloy. Each part of the electrode was assembled together by micro spot welding process and then the assembled electrodes were exposed to simulated glass beading temperatures of $700^{\circ}C,\;750^{\circ}C$ and $800^{\circ}C$. The microstructures of the microweld CCFL electrode were observed by using optical microscope, scanning electron microscope and EDS. Micro-tensile and microhardness test were also carried out. The results indicated that the grain coarsening in the HAZs(heat affected zones) for both the cup-pin weld and pin-lead wire were exhibited and the grain coarsening of the HAZ for the cup and the lead wire was more obvious than the HAZ of the pin. The micro-tensile test revealed that the fracture occurred at the cup-pin weld zone for all test conditions. The fracture surface could be classified into two parts such as pin portion and cup portion including weld nugget. The failure was seemed to be initiated from the boundary between nugget and pin through the weld joint. The result of the microhardness measurement exhibited that the relatively low hardness value, about 105HV was recorded at the HAZ of the cup. This value was about 50% less than that of the original value of the cup. The reduction of the microhardness was considered as the cause of the grain coarsening due to welding process. It was also appeared that there was no change in electric resistance for the standard electrodes and heat treated electrodes.