Engineering criticality analysis on an offshore structure using the first- and second-order reliability method

  • Kang, Beom-Jun;Kim, Jeong-Hwan;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.6
    • /
    • pp.577-588
    • /
    • 2016
  • Due to the uncertainties related to the flaw assessment parameters, such as flaw size, fracture toughness, loading spectrum and so on, the probability concept is preferred over deterministic one in flaw assessment. In this study, efforts have been made to develop the reliability based flaw assessment procedure which combines the flaw assessment procedure of BS7910 and first-and second-order reliability methods (FORM/SORM). Both crack length and depth of semi-elliptical surface crack at weld toe were handled as random variable whose probability distribution was defined as Gaussian with certain means and standard deviations. Then the limit state functions from static rupture and fatigue perspective were estimated using FORM and SORM in joint probability space of crack depth and length. The validity of predicted limit state functions were checked by comparing it with those obtained by Monte Carlo simulation. It was confirmed that the developed methodology worked perfectly in predicting the limit state functions without time-consuming Monte Carlo simulation.

Finite Element Analysis for Behavior of Aluminum Alloy Embedding a Particle under Equal Channel Angular Pressing (ECAP 공정시 강화상이 첨가된 금속기지 거동에 대한 유한요소해석)

  • Lee, S.C.;Ha, S.R.;Kim, K.T.;Chung, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1157-1162
    • /
    • 2003
  • Behavior of aluminum alloy embedding a particle was investigated at room temperature under ECAP. Finite element analysis by using ABAQUS shows that ECAP is a useful tool for eliminating residual porosity in the specimen, and much more effective under friction condition. The simulation, however, shows considerably low density distributions for matrix near a particle at which rich defects may occur during severe deformation. Finite element results of effective strains and deformed shapes for matrix with a particle were compared with theoretical calculations under simple shear stress. Also, based on the distribution of the maximum principal stress in the specimen, Weibull fracture probability was obtained for particle sizes and particle-coating layer materials. The probability was useful to predict the trend of more susceptible failure of a brittle coating layer than a particle without an interphase in metal matrix composites.

  • PDF

Application of Probabilistic Fracture Mechanics Methodology (확률론적 파괴역학 수법의 적용성 검토)

  • 이준성;곽상록;김영진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.667-670
    • /
    • 2001
  • For major structural components periodic inspections and integrity assessments are needed for the safety. However, many flaws are undetectable because sampling inspection is carried out during in-service inspection. Probabilistic integrity assessment is applied to take into consideration of uncertainty and variance of input parameters arise due to material properties and undetectable cracks. This paper describes a Probabilistic Fracture Mechanics(PEM) analysis based on the Monte Carlo(MC) algorithms. Taking a number of sampling data of probabilistic variables such as fracture toughness value, crack depth and aspect ratio of an initial surface crack, a MC simulation of failure judgement of samples is performed. For the verification of this analysis, a comparison study of th PFM analysis using a commercial code, mathematical method is carried out and a good agreement was observed between those results.

  • PDF

High-Yield Etching-Free Transfer of Graphene: A Fracture Mechanics Approach

  • Yoon, Taeshik;Jo, Woo Sung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.2
    • /
    • pp.59-64
    • /
    • 2014
  • Transfer is the critical issue of producing high-quality and scalable graphene electronic devices. However, conventional transfer processes require the removal of an underlying metal layer by wet etching process, which induces significant economic and environmental problems. We propose the etching-free mechanical releasing of graphene using polymer adhesives. A fracture mechanics approach was introduced to understand the releasing mechanism and ensure highyield process. It is shown that the thickness of adhesive and target substrate affect the transferability of graphene. Based on experimental and fracture mechanics simulation results, we further observed that compliant adhesives can reduce the adhesive stress during the transfer, which also enhances the success probability of graphene transfer.

Statistical Analysis of Thermal Fatigue Life for Automobile bulb (자동차용 전구의 열피로수명의 확률론적 거동)

  • 박상필;오환섭;박종찬;박철희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.160-165
    • /
    • 2004
  • At this research, we examined probability of light bulb's life span value and prediction on purpose to inquire out the span of repeat velocity as fracture probability by executing the fatigue test, which is considered property of Tungsten filament's thermal fatigue used as an automobile bulb. As a result we can confirm what the most suitable solution is weibull distribution and log normal distribution. Tungsten filament's span gets longer as the fatigue repeat velocity gets shorter And, repeat span is about 15%~40% shorter than sequence life span.

  • PDF

Development of P-PIE Program for Evaluating Failure Probability of Pipes in Nuclear Power Plants (원전 배관의 파손확률평가를 위한 P-PIE 프로그램의 개발)

  • Park, Jai-Hak;Lee, Jae-Bong;Choi, Young-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.1-8
    • /
    • 2010
  • P-PIE program is developed for evaluating failure probability of pipes in nuclear power plants based on the existing PRAISE program. In the program, crack growth due to fatigue loading and stress corrosion can be considered and the probability of fracture or leakage of pipes can be calculated. Crack growth simulation is performed based on stress intensity factor and a damage parameter and failure of a pipe is determined based on J integral or net section yielding. Using the developed program the failure probabilities of tubes in a domestic nuclear power is obtained and discussed.

Influence of Multiple Rib Fracture upon Traumatic Hemo-pneumothorax (다발성 늑골골절의 외상성 혈기흉 발생에 대한 영향)

  • Yang, Seung-Joon;Lee, Je-won;Jin, Sang-Chan;Joo, Myeong-Don;Choi, Woo-Ik
    • Journal of Trauma and Injury
    • /
    • v.21 no.2
    • /
    • pp.91-99
    • /
    • 2008
  • Purpose: Multiple rib fracture (MRF) and a hemopneumothorax accompany with most blunt chest traumas. We aimed to analyze the factors increasing the probability of a hemopneumothorax. In addition, other injuries accompanying MRF were analyzed. Methods: We retrospectively reviewed the medical records of 154 mutiple rib fracture patients who visited our hospital between January 2005 and December 2007. The medical records were reviewed for sex, age, mechanism of injury, location, number of fractures, distance of dislocated rib fragments, and presence of complications. We measured the distance of bony dislocations by using the PACS (Picture Archiving and Communication System). Results: The average number of rib fractures was $3.7{\pm}2.1$, and the number of rib fractures significantly influenced the incidence of a hemothorax (p<0.001). The risk of a hemothorax was increased in a bilateral MRF compared to a unilateral MRF (p=0.027). The distance of dislocated rib fragments influenced the probability of a hemothorax significantly (p=0.018), and subcutaneous emphysema and lung contusion were significantly associated with a pneumothorax (p=0.021, p=0.036). Conclusion: The number of MRFs did not influence the risk for a pneumothorax, but did influence the risk for a hemothorax. The laterality, distance of dislocation, also had an influence on the risk for a hemothorax. Also, subcutaneous emphysema and lung contusion were increased in cases with a pneumothorax. We must consider the possibility of a hemothorax even when the initial chest X-ray shows no evidence of a hemothorax. If a lung contusion is present, then an occult pneumothorax must be considered.

A Study on the Fracture Strength of All-Ceramic Crown according to the Zirconia Coping Design using CAD/CAM System (CAD/CAM을 이용하여 제작한 전부도재관의 지르코니아 코핑 디자인에 따른 파절강도에 관한 연구)

  • Bulgan, L.;Cho, In-Ho;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.111-123
    • /
    • 2006
  • A Study on the Fracture Strength of All-Ceramic Crown according to the Zirconia Coping Design using CAD/CAM System L. Bulgan, In-Ho Cho, Soo-Yeon Shin Department of Prosthodontics, Graduate School, Dankook University The fracture strength of prosthesis is important, because it affects the function, and long term success of prosthesis and teeth. The purpose of this study was to compare the fracture strength of zirconia coping designs. Experimental test group were classified into three designs according to coping design, Modified design: Zirconia coping margin was located at 1mm above the axiogingival line angle. Collarless design: The coping margin terminated at the axiogingival line angle Butt design: The coping margin was extended to the finishing line of prepared margin. A $Cercon^{(R)}$(Degussa, Germany) CAD/CAM system was used to make the zirconia coping. Fracture strength was measured using loading machine at a cross head speed of 1mm/min. The results were statistically analyzed using the one-way ANOVA and multiple comparison test. Statistical significance was set in advance at the probability level of less than 0.05. The result : I. Collarless($738N{\pm}155N$) and Modified($755N{\pm}185N$) groups showed significantly a lower fracture strength than Butt($1057N{\pm}262N$) group(p<0.05). II. There were no statistical differences of the fracture strength between Modified($755N{\pm}185N$) and Collarless($738N{\pm}155N$) groups. III. When comparing the fractured surface, all the group showed porcelain fracture, which were fractured at the labial surface of baked porcelain The butt design of the zirconia coping has higher fracture strength than modified and collarless design.

Fracture Strength of Porcelain Fused to Gold Crown & Gold Electroformed Crown (전기도금도재관과 금속도재관의 파절강도)

  • Park, Won-Ju;Lim, Ju-Hwan;Cho, In-Ho;Lim, Heon-Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.2
    • /
    • pp.101-111
    • /
    • 2002
  • The purpose of this study was to evaluate the fracture strength of porcelain fused to gold crown and gold electroformed crown according to incisal and incisal under 3mm. In this study, 28 gold electroformed crown and 28 porcelain fused to gold crown were fabricated. Fracture strength testing was carried out using an Instron 8871(Instron Corporation, U.S.A) at a cross head speed of 5mm/min. All of the measurements were statistically analyzed by Independent t-testing, and k-s testing. Statistical significance was set in advance at the probability level of less than 0.05. All measurements were analized with Windows $SPSS^{(R)}$ Version 10.0 software for the personal computer. The results of this study were as follows; 1. Comparison by location (1) A compared fracture strength of incisal and incisal under 3 mm, there was statistical significant difference between gold electro -formed crown and porcelain fused to gold crown (p<0.05). 2. Comparison by loading (1) When compared fracture strength of incisal, there was no significant difference between gold electroformed crown ($619.90{\pm}53.54N$)and porcelain fused to gold crown($674.68{\pm}87.42N$). (2) When compared fracture strength of incisal under 3 mm, there was significant difference between gold electroformed crown($688.29{\pm}14.88N$) and porcelain fused to gold crown($1931.81{\pm}29.64N$) (p<0.05). 3. Mode of fracture When compared of fracture mode, gold electroformed crown showed mode of fracture and fracture line reaching coping region and porcelain fused to gold crown showed only in porcelain region.