• 제목/요약/키워드: Fracture Toughness Testing

검색결과 117건 처리시간 0.026초

Standardization of Fracture Toughness Testing of Ceramics in the United States

  • Quinn, G.D.;Jenkins, M.J.;Salem, J.;Bar-On, I.
    • The Korean Journal of Ceramics
    • /
    • 제4권4호
    • /
    • pp.311-322
    • /
    • 1998
  • American Society for Testing and Materials (ASTM) standard test method PS 070-97 has been created for measuring fracture toughness of advanced ceramics. PS 070-97 includes three test methods which use beams in bending: chevron notch (CNB), single-edged precracked beam (SEPB), and surface crack in flexure (SCF). Supporting data has been collected through several Versailles Advanced Materials and Standards round robins. This paper discusses the evolution of the standard including the rationale for the choice of the three methods and the specifications in the standard. Progress on Standard Reference material 2100 which will have certified values of fracture toughness is presented.

  • PDF

극저온용 구조재료의 파괴인성평가법에 관한 연구 (A study on the fracture toughness evaluating method for cryogenic structural material)

  • 권일현;정세희
    • 대한기계학회논문집A
    • /
    • 제22권1호
    • /
    • pp.64-72
    • /
    • 1998
  • This paper was undertaken to develop the fracture toughness testing method using small and single specimen compared to the conventional method in evaluating elastic-plastic fracture toughness of the superconducting magnet structural material at cryogenic temperature. The elastic-plastic fracture toughness test was conducted by using the unloading compliance method recommended by ASTM E813-89 to accomplish the above purpose. And, the 20% side-grooved 0.5TCT and 1TCT specimens were used to evaluate the fracture toughness by using as possible as miniaturized CT specimen. The unloading compliance method was a very useful method in evaluating elastic-plastic fracture toughness at cryogenic temperature. It could be taken valid fracture toughness values by using 20% side-grooved 0.5TCT specimen recommended by ASTM E813-89.

計裝化 샬피 시험법 에 의한 알루미늄 합금 용접부 의 동적파괴 인성 (The dynamic fracture toughness of aluminum alloy weld zone by instrumented charpy test)

  • 문경철;강락원;이준희
    • Journal of Welding and Joining
    • /
    • 제3권2호
    • /
    • pp.42-51
    • /
    • 1985
  • The dynamic fracture toughness, fracture characteristics, impact tension and tensile properties of Al-Mg-Si T5 alloy and Al-Zn-Mg T6 alloy respectively welded with filler metal of Alcan 4043 were investigated. The dynamic fracture toughness values were obtained rapidly and simply for the specimen of small size by using instrumented Chirpy impact testing machine. the testing temperatures of the specimen were a range of room temperature and-196.deg. C. The results obtained in this experiment are summarized as follows. With decreasing the testing temperatures, dynamic tensile stress and fracture load were increased, on the other hand the deflection and impact value showed decreasing tendency in order of base metal>HAZ>weld. Changes of total absorbed energy were more influenced by the crack propagation energy than the crack initiation energy. At the low temperatures, the unstable rapid fracture representing the crack propagation appeared for the specimens of Charpy press side notched in Al-Zn-Mg alloy, but it was difficult to obtain the unstable rapid fracture in Al-Mg-Si alloy. Because of the development of plastic zone at the notch root, it was difficult to obtain thevalid $K_{1d}$ value in Al-Mg-Si alloy. Therefore the fatigue cracked specimens were effective in both Al-Mg-Si and Al-Zn-Mg alloys. With decreasing the impact testing temperatures, specimens underwent a transition from dimple-type transgranular fracture to lamella surface-type intergranular fracture because of the precipitate at the grain boundaries, impurities and crystal structure of the precipitates.s.

  • PDF

PCVN 시편 파괴인성의 균열 깊이 영향에 대한 Scaling 모델 해석 (Analysis of Cleavage Fracture Toughness of PCVN Specimens Based on a Scaling Model)

  • 박상윤;이호진;이봉상
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.409-416
    • /
    • 2009
  • Standard procedures for a fracture toughness testing require very severe restrictions for the specimen geometry to eliminate a size effect on the measured properties. Therefore, the used standard fracture toughness data results in the integrity assessment being irrationally conservative. However, a realistic fracture in general structures, such as in nuclear power plants, may develop under the low constraint condition of a large scale yielding with a shallow surface crack. In this paper, cleavage fracture toughness tests have been made on side-grooved PCVN (precracked charpy V-notch) type specimens (10 by 10 by 55 mm) with various crack depths. The constraint effects on the crack depth ratios were evaluated quantitatively by the developed scaling method using the 3-D finite element method. After the fracture toughness correction from scaling model, the statistical size effects were also corrected according to the standard ASTM E 1921 procedure. The results were evaluated through a comparison with the $T_0$ of the standard CT specimen. The corrected $T_0$ for all of the PCVN specimens showed a good agreement to within $5.4^{\circ}C$ regardless of the crack depth, while the averaged PCVN $T_0$ was $13.4^{\circ}C$ higher than the real CT test results.

미소 파괴음 빈도 측정에 의한 화강암의 파괴인성 평가에 관한 연구 (A study on the estimation of fracture toughness of granite by acoustic emission)

  • 신재근;이상은;임한욱
    • 터널과지하공간
    • /
    • 제10권2호
    • /
    • pp.227-236
    • /
    • 2000
  • 국제 암반역학회에서는 암석의 파괴인성 시험법으로 CB 및 SR 2가지 시험법을 제안하였다. 본 연구에서는 춘천 화강암을 대상으로 CB와 SR 시편을 제작하고 Level I시험 및 J-적분에 의한 파괴인성 평가를 실시하였으며, 아울러 AE법을 이용하여 J-적분으로 해석하고 그 결과를 서로 비교하였다. 또한 각각의 초기균열 방향에 따라 파괴인성 결과를 비교하여 이방성의 영향을 검토하였으며, CB 및 SR 시편이 파괴될 때 나타나는 AE 신호의 특성도 고찰하였다.

  • PDF

Estimation of fracture toughness of cast steel container from Charpy impact test data

  • Bellahcenea, Tassadit;Aberkane, Meziane
    • Steel and Composite Structures
    • /
    • 제25권6호
    • /
    • pp.639-648
    • /
    • 2017
  • Fracture energy values KV have been measured on cast steel, used in the container manufacture, by instrumented Charpy impact testing. This material has a large ductility on the upper transition region at $+20^{\circ}C$ and a ductile tearing with an expended plasticity before a brittle fracture on the lower transition region at $-20^{\circ}C$. To assess the fracture toughness of this material we use, the $K_{IC}$-KV correlations to measure the critical stress intensity factor $K_{IC}$ on the lower transition region and the dynamic force - displacement curves to measure the critical fracture toughness $J{\rho}_C$, the essential work of fracture ${\Gamma}_e$ on the upper transition region. It is found, using the $K_{IC}$-KV correlations, that the critical stress intensity factor $K_{IC}$ remains significant, on the lower transition region, which indicating that our testing material preserves his ductility at low temperature and it is apt to be used as a container's material. It is, also, found that the $J_{\rho}-{\rho}$ energetic criterion, used on the upper transition region, gives a good evaluation of the fracture toughness closest to those found in the literature. Finally, we show, by using the ${\Gamma}_e-K_{IC}$ relation, on the lower transition region, that the essential work of fracture is not suitable for the toughness measurement because the strong scatter of the experimental data. To complete this study by a numerical approach we used the ANSYS code to determine the critical fracture toughness $J_{ANSYS}$ on the upper transition region.

Evaluation and Interpretation of the Fracture Toughness of Rocks

  • Baek, Hwanjo
    • 한국암반공학회:학술대회논문집
    • /
    • 한국암반공학회 1996년도 정기총회 및 학술발표회
    • /
    • pp.1-10
    • /
    • 1996
  • Fracture toughness of rock materials, which generally violate the fundamental assumptions of LEFM, often depends on the specimen size and test method employed. Hence, a standardized procedure for testing and data interpretation for determining fracture toughness of rock materials is required. Special attention has been given by the International Society for Rock Mechanics (ISRM) to the difficulties in obtaining true fracture mechanics parameters for the wide variety of rock materials. (omitted)

  • PDF

탄소섬유복합재료의 충격 손상에 따른 파괴 인성과 AE 특성 (Fracture Toughness and AE Behavior of Impact-Damaged CFRP)

  • 이상국;남기우;오세규
    • 비파괴검사학회지
    • /
    • 제17권2호
    • /
    • pp.81-88
    • /
    • 1997
  • 탄소섬유강화복합재료(CFRP) 적층판에 비교적 낮은 에너지의 충격을 주어, 충격에 의해서 손상된 적층판을 사용하여 인장강도, 파괴 인성 및 AE 신호 특성에 미치는 충격 손상의 영향에 대하여 검토하였다. 충격손상재의 인장강도, 파괴 인성 및 AE-event count는 충격 속도와 박리 면적의 증가에 따라서 감소함을 알 수 있었다. 그리고 충격시험시에 발생한 박리 면적은 충격 속도와 비례하였다. 또한 적층 방법에 따른 손상재의 강도비와 파괴 인성비가 달라짐이 확인되어 복합재료의 내충격 설계시 손상량과 손상재의 파괴 인성 및 강도에 대한 정량적 평가를 AE 신호로부터 해석할 수 있음이 확인되었다.

  • PDF

암석의 전단 파괴인성 측정에 관한 실험적 연구 (An Experimental Study on Mode ll Fracture Toughness Determination of Rock)

  • 윤정석;전석원
    • 터널과지하공간
    • /
    • 제13권1호
    • /
    • pp.64-75
    • /
    • 2003
  • 본 연구에서는 2001년 Bakers와 Stephansson이 제안한 Punch Through Shear Test를 소개한다. 본 연구의 목적은 대전화강암을 사용하여 이 시험법이 암석의 전단 모드 파괴 인성 측정법으로서의 적합성을 알아보는 것이다. 또한, 전단모드 파괴인성을 구하기 위한 최적의 시료형상을 결정하고 전단모드 파괴인성과 봉압과의 관계를 규명하였다. 시험결과, 인장 파괴에서와 같이 거친 파괴면이 형성되지 않고 전단을 받았음을 알 수 있는 부드러운 파괴면이 관찰되었다. 시료형상에 대한 연속체 해석과 입자유동 해석 그리고 균열전파 시뮬레이션을 수행한 결과 시료내부에서 일어나는 균열의 발생은 주로 전단모드이고 이러한 전단균열들로 인해 시료의 파괴가 발생함을 입증할 수 있었으며, 결과적으로 Punch Through Shear Test는 암석의 전단모드 파괴인성 측정법으로서 적합함을 입증할 수 있었다.

암석의 파괴인성 측정에서 나타나는 CB 시험편의 치수효과에 관하여 (The Size Effect in Measuring the Fracture Toughness of Rock using Chevron Bend Specimen)

  • 김재동;백승규
    • 터널과지하공간
    • /
    • 제2권2호
    • /
    • pp.251-264
    • /
    • 1992
  • In this study, the size effect in measuring the fracture toughness of rock was investigated using the ISRM Suggested Method for Fracture toughness using Chevron Bend Specimens. Total 58 specimens were prepared with 4 different diameters, 29, 42, 54, 68mm and center cut-chevron notch. In addition to this, to evaluated the effect of anisotropy of Jecheon granite, which is the sample for this study, core drilling direction was adjusted perpendicular(short transverse) and parallel(arrester) to the rift plane in the sample and the measured fracture toughness for each direction were compared. Important results obtained from this study are as follows. Level ll test condition is more adequate than l, because of low data scattering and precision and corrected fracture toughness of Jechoen granite measured and 2.2MPa{{{{ SQRT { m} }}}} for arrester direction with minimum initial crack length 0.7cm. From the relationship between core diameter and initial crack length presented in the ISRM testing method, the specimen diameter should be bigger than 47mm. The fracture toughnesses measured for arrester and short transverse directon show 10% difference. This is to the anisotropy of Jecheon granite possessing rift plane.

  • PDF