• Title/Summary/Keyword: Fracture Test

Search Result 2,771, Processing Time 0.025 seconds

Survival analysis of dental implants in maxillary and mandibular molar regions; A 4$\sim$5 year report ($\cdot$하악 대구치 부위에 식립된 임플란트의 생존율에 대한 후향적 연구)

  • Jang, Jin-Wha;Ryoo, Gyeong-Ho;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.165-180
    • /
    • 2007
  • Dental Implants have been proved to be successful prosthetic modality in edentulous patients for 10 years. However, there are few reports on the survival of implant according to location in molar regions. The purpose of this study was to evaluate the $4{\sim}5$ years' cumulative survival rate and the cause of failure of dental implants in different locations for maxillary and mandibular molars. Among the implants placed in molar regions in Gwangju Mir Dental Hospital from Jan. 2001 to Jun. 2002, 473 implants from 166 patients(age range; $26{\sim}75$) were followed and evaluated retrospectively for the causes of failure. We included 417 implants in 126 periodontally compromised patients, 56 implants in 40 periodontal healthy patients, and 205 maxillary and 268 mandibular molar implants. Implant survival rates by various subject factors, surgical factors, fixture factors, and prosthetic factors at each location were compared using Chi-square test and Kaplan-Meier cumulative survival analysis was done for follow-up(FU) periods. The overall failure rate at 5 years was 1O.2%(subject level) and 5.5%(implant level). The overall survival rates of implants during the FU periods were 94.5% with 91.3% in maxillary first molar, 91.1% in maxillary second molar, 99.2% in mandibular first molar and 94,8% in mandibular second molar regions. The survival rates differed significantly between both jaws and among different implant locations(p<0.05), whereas the survival rates of functionally loaded implants were similar in different locations. The survival rates were not different according to gender, age, previous periodontal status, surgery stage, bone graft type, or the prosthetic type. The overall survival rate was low in dental implant of too wide diameter(${\geq}5.75$ mm) and the survival rate was significantly lower for wider implant diameter(p

Cyclic fatigue resistance, torsional resistance, and metallurgical characteristics of M3 Rotary and M3 Pro Gold NiTi files

  • Pedulla, Eugenio;Lo Savio, Fabio;La Rosa, Giusy Rita Maria;Miccoli, Gabriele;Bruno, Elena;Rapisarda, Silvia;Chang, Seok Woo;Rapisarda, Ernesto;La Rosa, Guido;Gambarini, Gianluca;Testarelli, Luca
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.2
    • /
    • pp.25.1-25.10
    • /
    • 2018
  • Objectives: To evaluate the mechanical properties and metallurgical characteristics of the M3 Rotary and M3 Pro Gold files (United Dental). Materials and Methods: One hundred and sixty new M3 Rotary and M3 Pro Gold files (sizes 20/0.04 and 25/0.04) were used. Torque and angle of rotation at failure (n = 20) were measured according to ISO 3630-1. Cyclic fatigue resistance was tested by measuring the number of cycles to failure in an artificial stainless steel canal ($60^{\circ}$ angle of curvature and a 5-mm radius). The metallurgical characteristics were investigated by differential scanning calorimetry. Data were analyzed using analysis of variance and the Student-Newman-Keuls test. Results: Comparing the same size of the 2 different instruments, cyclic fatigue resistance was significantly higher in the M3 Pro Gold files than in the M3 Rotary files (p < 0.001). No significant difference was observed between the files in the maximum torque load, while a significantly higher angular rotation to fracture was observed for M3 Pro Gold (p < 0.05). In the DSC analysis, the M3 Pro Gold files showed one prominent peak on the heating curve and 2 prominent peaks on the cooling curve. In contrast, the M3 Rotary files showed 1 small peak on the heating curve and 1 small peak on the cooling curve. Conclusions: The M3 Pro Gold files showed greater flexibility and angular rotation than the M3 Rotary files, without decrement of their torque resistance. The superior flexibility of M3 Pro Gold files can be attributed to their martensite phase.

Breakage and Liberation Characteristics of Iron Ore from Shinyemi Mine by Ball Mill (신예미 광산 철광석의 볼밀 분쇄 및 단체분리 특성 연구)

  • Lee, Donwoo;Kwon, Jihoe;Kim, Kwanho;Cho, Heechan
    • Resources Recycling
    • /
    • v.29 no.3
    • /
    • pp.11-23
    • /
    • 2020
  • This study aims to investigate breakage and liberation characteristics of iron ore from Shinyemi mine, Jeongseon by ball mill. Parameters of breakage functions for three grade samples of iron ore were obtained using single-sized-feed breakage test and back-calculation based on nonlinear programming. The results showed that with the increase in the grade of iron ore, the breakage rate factor decrease whereas the particle size sensitivity decreases. This results from retardation of microcrack-propagation by magnetite grain in the ore. Breakage distribution analysis showed that the breakage mechanism appear to be impact fracture dominant with the increase of grade owing to the stress distribution effect by magnetite grain. Degree of liberation (DOL) increased with the increase in grade and decrease in particle size, respectively. Using the breakage function and size-DOL relationship, a model that can predict time-dependent-DOL is established. When scale-up factors from operating condition are available, the model is expected to be capable of predicting size and DOL with time in actual mining process.

A Study on the Resistance of Stress Corrosion Cracking due to Expansion Methods for Steam Generator Tubes in Nuclear Power Plants (원전 증기발생기 전열관의 확관방법에 따른 응력부식균열 저항성 연구)

  • Kim, Young Kyu;Song, Myung Ho
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.149-157
    • /
    • 2014
  • The steam generator tubes of nuclear power plants have various types of corrosion failures during the plant operation. The stress corrosion cracking which occurs on the outer surface of tube is called the secondary side stress corrosion cracking and mainly occurs in the expansion-transition area of tube. The causes are the concentration of impurities by the sludge pile-up related to the geometry of its region and the residual stress by tube expansion in the process of steam generator manufacturing. Especially the directionality and sizes of residual stresses are differed according to the tube expansion methods and the direction and the frequency of tube cracks depend on their characteristics. In bases on the plant experiences, it is notified that circumferential cracks of tubes expanded with explosive expansion method are dominantly occurred compared to those of tubes done with hydraulic expansion one. Therefore in this study, according to tube expansion methods frequencies and sizes of tube cracks with specific direction are compared by means of accelerated immersion test and also the crack morphology and the specific chemicals from water-chemistry environment are observed through the fracture surface examination.

The Analysis of Geothermal Gradient at Icheon Hot Spa Area (이천 온천원보호지구의 지온경사 해석)

  • Lee, Chol-Woo;Moon, Sang-Ho
    • The Journal of Engineering Geology
    • /
    • v.18 no.2
    • /
    • pp.185-190
    • /
    • 2008
  • Nine wells have been developed for uses of thermal waters at the Icheon hot spa area. Drilling depths of those hot spring wells range from 166 to 294 m and their piezometric heads are located at about 50 m below the surface. Using the differences between the surface and bottom temperatures within all boreholes, we can simply estimate geothermal gradient in this area. Thus, we obtained the highest, lowest and average gradient values as $64^{\circ}C/km$ from SB-2 well, $45^{\circ}C/km$ from SB-1 well and approximately $54.28^{\circ}C/km$, respectively. However, observing the MRD-2 well additionally drilled into the depth of 996 m, we found out that this study area has widely experienced the temperature disturbance due to thermal groundwater penetration through the fracture systems within the depth of 720 m. Unlikely this phenomenon, we can conclude that the groundwater flow below the depth of 720 m does not exist. Therefore, using only those temperature data below the 720 m depth, we can estimate reasonable geo-thermal gradient values as $33^{\circ}C/km$ in this study area. Pumping test shows that outflowing temperature is $36^{\circ}C$ corresponding to the temperature logging data at 720 m depth.

Fatigue Analysis based on Kriging for Flaperon Joint of Tilt Rotor Type Aircraft (틸트 로터형 항공기의 플랩퍼론 연결부에 대한 크리깅 기반 피로해석)

  • Park, Young-Chul;Jang, Byoung-Uk;Im, Jong-Bin;Lee, Jung-Jin;Lee, Soo-Yong;Park, Jung-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.6
    • /
    • pp.541-549
    • /
    • 2008
  • The fatigue analysis is performed to avoid structural failure in aerospace structures under repeated loads. In this paper, the fatigue life is estimated for the design of tilt rotor UAV. First of all, the fatigue load spectrum for tilt rotor UAV is generated. Fatigue analysis is done for the flaperon joint which may have FCL(fracture critical location). Tilt rotor UAV operates at two modes: helicopter mode such as taking off and landing; fixed wing mode like cruising. To make overall fatigue load spectrum, FELIX is used for helicopter mode and TWIST is used for fixed wing mode. The other hand, the Kriging meta model is used to get S-N regression curve for whole range of material life when S-N test data are analyzed. And then, the second order of S-N curve is accomplished by the least square method. In addition, the coefficient of determination method is used to ensure how accuracy it has. Finally, the fatigue life of flaperon joint is compared with that obtained by MSC. Fatigue.

Bone Segmentation Method based on Multi-Resolution using Iterative Segmentation and Registration in 3D Magnetic Resonance Image (3차원 무릎 자기공명영상 내에서 영역화와 정합 기법을 반복적으로 이용한 다중 해상도 기반의 뼈 영역화 기법)

  • Park, Sang-Hyun;Lee, Soo-Chan;Yun, Il-Dong;Lee, Sang-Uk
    • Journal of Broadcast Engineering
    • /
    • v.17 no.1
    • /
    • pp.73-80
    • /
    • 2012
  • Recently, medical equipments are developed and used for diagnosis or studies. In addition, demand of techniques which automatically deal with three dimensional medical images obtained from the medical equipments is growing. One of the techniques is automatic bone segmentation which is expected to enhance the diagnosis efficiency of osteoporosis, fracture, and other bone diseases. Although various researches have been proposed to solve it, they are unable to be used in practice since a size of the medical data is large and there are many low contrast boundaries with other tissues. In this paper, we present a fast and accurate automatic framework for bone segmentation based on multi-resolutions. On a low resolution step, a position of the bone is roughly detected using constrained branch and mincut which find the optimal template from the training set. Then, the segmentation and the registration are iteratively conducted on the multiple resolutions. To evaluate the performance of the proposed method, we make an experiment with femur and tibia from 50 test knee magnetic resonance images using 100 training set. The proposed method outperformed the constrained branch and mincut in aspect of segmentation accuracy and implementation time.

A study on the Creep fracture life prediction of Al7075 alloy under high temperature (고온상태에서 Al 7075 합금의 크리이프 파단수명 예측에 대한 연구)

  • Kang, Dae-Min;Koo, Yang;Baek, Nam-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.3 no.2
    • /
    • pp.35-48
    • /
    • 1988
  • Modern technological progress demands the use of materials at high temperature and high pressure. One of the most critical factors in considering such applications - perhaps the most critical one - is creep behavior. In this study the stress exponents n were determined during creep over the temperature range of $90^{\circ}C\;to\;500^{\circ}C$ (0.4 - 0.85 Tm) and stress range of 0.64 kgt/$mm^2$ in order to investigate the creep hehavior. The stress dependence of rapture time (n') were determined over the temperature range of $200^{\circ}C\;to\;240^{\circ}C$ and stress range of 8.13 kgt/$mm^2$ to 9.55 kgt/$mm^2$ in order to investigate to creep rupture property. And the stress transient dip tests were also carried out for the internal stress ${\sigma}i$ over the temperature range of $90^{\circ}C\;to\;500^{\circ}C$ and stress range of 0.64kgt/$mm^2$ to 17.2 kgt/$mm^2$. The creep tests for constant temperature and stress transient dip tests were conducted in air with Al 7075 alloy under constant tensile load. At around the temperature range $200^[\circ}C\;-\;230^{\circ}C$ and the stress level 8.13 - 9.55 (kgt/$mm^2$), the temperature range $280^{\circ}C\;-\;310^{\circ}C$ and the stress level 1.85 - 2.55 (kgt/$mm^2$), the temperature range $380^{\circ}C\;-\;410^{\circ}C$ and the stress 1.53 - 0.91 (kgt/$mm^2$), the stress exponent in had the value of 6.2 - 6.65 but at around the temperature range $90^{\circ}C\;-\;120^{\circ}C$ and the stress level 10 - 17.2(kgt/$mm^2$), the value of 1.3, and at around the temperature range $470^{\circ}C\;-\;500^{\circ}C$, the stress level 0.62 - 1.02 (kgt/$mm^2$) the value of 1-1. Besides these results, at around the temperature $200^{\circ}C\;-\;240^{\circ}C$ the stress dependence of rupture time (n') had the value of 6.3. Finally, it was found that the value n calculated by considering the applied stress dependence of the internal stress were in good agreement with those obtained for the creep test. Then, it was concluded that the change in n was mainly attributed to the difference of the applied stress dependence of the internal stress and the ratio of the internal stress to the applied stress, and the creep rupture life may be represented as.

  • PDF

AN EXPERIMENTAL STUDY ON SHEAR BOND STRENGTH OF GLASS IONOMER CEMENT TO DENTIN SURFACE FOLLOWING SURFACE CONTIONING (상아질 표면처리가 글라스 아이오노머 시멘트의 결합강도에 미치는 영향에 관한 연구)

  • Lee, Kwang-Woo;Hong, Chan-Ui;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.104-114
    • /
    • 1992
  • The purpose of this study was to evaluate the shear bond strength of glass ionomer cement(Ketacfil, ESPE, Co.) against dentin surface which had been treated with surface conditioning agents(distilled water, 5% sodium hypochlorite solution, Ketac - conditioner, 40% polyacrylic acid). In this study, 60 human molars with sound and healthy crown portion which were previously extracted for orthodontic or periodontal problem. The dentin surfaces of these teeth were exposed with wet trimmer and polished with 150 - grit and 600 - grit silicon carbide paper and the teeth were divided into four groups(15 teeth per group) according to the following surface conditioning methods. Group I : Surface treatment with distilled water as control group. Group II : Surface conditioning with 5% sodium hypochlorite solution. Group III : Surface conditioning with Ketac conditioner. Group IV : Surface conditioning with 40% polyacrylic acid. The shear bond strengths were measured by Autograph(Shimatzu Co. Japan). The result of the evaluations were then subjected to statistical analysis using one - way analysis of variance and Duncan test and the results were as follows : 1. The shear bond strength accrding to the dentin surface conditioning conditions was highest in Ketac conditioner group, with measurements of $44.44{\pm}0.74(kg/cm^2)$ and lowest in the distilled water group, with measurements of $28.84{\pm}0.88(kg/cm^2)$. 2. Statistically significant differences were found between surface conditioning with 5% sodium hypochlorite solution group or Ketac conditioner group and distilled water group(P<0.01). 3. Also, statistically significant difference was found between surface conditioning with distilled water group and 40% polyacrylic acid group(P<0.05). 4. Overall difference in statistical significance between the groups was not found (P<0.05). 5. Fractured dentin surface treated with conditioning solutions showed cohesive fracture. 6. Distilled water group and 5% sodium hypochlorite solution group removed the smear layer less effectively. 7. Conditioning dentin with Ketac conditioner and 40% polyacrylic acid resulted in the removal of a significant amount of the smear layer without removing the tubular plugs and dissolving the peritubular dentin.

  • PDF

The shoulder diagnosis Scapula study of patients who visited the hospital (병원 내원한 환자 견갑골(scapula) 진단을 위한 연구)

  • Ahn, Byeong-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.13-20
    • /
    • 2010
  • True lateral scapula image was very important to diagnosis the scapula fracture and dislocation induced by traumatic injury. The aim of this study was to know the patient rotation angle to be showing the scapula true lateral in korean. d Materials Thirty patients(22men, 8 women, mean ages 53.4)with scapular pain, had supine Anteroposterior projection taken with $30^{\circ}$, $40^{\circ}$, $45^{\circ}$ trunk rotation angle changing the manual angulation material. Radiographs were evaluated independently by 5 experienced observers(1 orthopedics surgery specialist, 1 diagnostic radiology specialist, 3 radiological technologist) They assessed overlap of vertebral border and axillary border of scapula as follows; Totally overlapping of vertebral border and axillary border is 4, partially overlapping is 3, not overlapping is 2 and oblique location with two borders is 1. All observers scored using by PACS monitor.$30^{\circ}$ trunk rotation was scored $1.53{\pm}0.39$, $40^{\circ}$ trunk rotation was scored $3.83{\pm}0.15$ and $45^{\circ}$ trunk rotation was scored $2.17{\pm}0.43$. There was no difference(p<0.05) between group of more than 100cm of the girth of the chest and group of less than 100cm. Similarly, men and women group showed no difference(p<0.05) with trunk rotation statistically. There was no result of trunk rotation angle to radiograph the true scapula lateral image up to date. This studies were summarized as follows; Adaptation of $40^{\circ}$ trunk rotation was the best to show the true scapula lateral image in korean. Our results were very useful to get the true scapula lateral images in clinic.