• Title/Summary/Keyword: Fracture Signal

Search Result 162, Processing Time 0.033 seconds

Evaluation of Fracture Toughness and the Micro-Fracture Mechanism of Porous Glass Composite by Using Acoustic Emission Technique (음향방출법을 이용한 글래스 복합재료의 파괴인성 및 미시파괴과정의 평가)

  • 정희돈;권영각;장래웅
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.6
    • /
    • pp.1388-1398
    • /
    • 1994
  • The fracture toughness and micro-fracture mechanisms of the porous glass and stainless fiber reinforced glass composite were evaluated by using the acoustice mission(AE) technique, fracture toughness $test(K_{IC})$ and the macroscopic observation of the specimen surface which was being under the loading. At initial portion of the loading, the AE signals with low energy, of which origins were considered as the micro-cracks formated at the crack tip, were emitted. With increasing the applied load, AE signals having higher energies were generated due to the coalesence of micro-cracks and fast fracture. Based on the such relationship between AE emission and loading condition, fracture toughness $K_{IAE}$ could be defined successfully be using the $K_I$ value corresponding to an abrupt change of the accumulated AE signal energies emitted during the fracture toughness test. In spite of its brittleness of glass material, nonlinear deformation behavior before maximum load was observed due to the formation of micro-cracks. Further, the stainless fiber may have attributed to the improvement of fracture toughness and the resistance to crack propagation comparing to noncomposited materials Finally, models of the micro-fracture process combined with the AE sources for the porous glass material and its composite were proposed paying attention to the micro-crack nucleation and its coalescence at the crack tip. Fiber fracture and its Pullout, deformation of fiber itself were also delinated from the model.

Chip Breaking Prediction Using AE Signal (AE신호에 의한 칩 절단성 예측)

  • 최원식
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.61-67
    • /
    • 1999
  • In turning the chip may be produced in the form of continuous chip or discontinuous one. Continuous chips produced at high speed machining may hit the newly cut workpiece surface and adversely affect the appearance of the surface finish and may interfere with tool and sometimes induce tool fracture. In this study relationship between AE signal and chip form was experimentally investigated, The experimental results show that types of chip form are possible to be classified from the AE signal using fuzzy logic.

  • PDF

Diagnostic Performance of Diffusion-Weighted Steady-State Free Precession in Differential Diagnosis of Neoplastic and Benign Osteoporotic Vertebral Compression Fractures: Comparison to Diffusion-Weighted Echo-Planar Imaging

  • Shin, Jae Ho;Jeong, Soh Yong;Lim, Jung Hyun;Park, Jeongmi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.154-161
    • /
    • 2017
  • Purpose: To evaluate the diagnostic performance of diffusion-weighted steady-state free precession (DW-SSFP) in comparison to diffusion-weighted echo-planar imaging (DW-EPI) for differentiating the neoplastic and benign osteoporotic vertebral compression fractures. Materials and Methods: The subjects were 40 patients with recent vertebral compression fractures but no history of vertebroplasty, spine operation, or chemotherapy. They had received 3-Tesla (T) spine magnetic resonance imaging (MRI), including both DW-SSFP and DW-EPI sequences. The 40 patients included 20 with neoplastic vertebral fracture and 20 with benign osteoporotic vertebral fracture. In each fracture lesion, we obtained the signal intensity normalized by the signal intensity of normal bone marrow (SI norm) on DW-SSFP and the apparent diffusion coefficient (ADC) on DW-EPI. The correlation between the SI norm and the ADC in each lesion was analyzed using linear regression. The optimal cut-off values for the diagnosis of neoplastic fracture were determined in each sequence using Youden's J statistics and receiver operating characteristic curve analyses. Results: In the neoplastic fracture, the median SI norm on DW-SSFP was higher and the median ADC on DW-EPI was lower than the benign osteoporotic fracture (5.24 vs. 1.30, P = 0.032, and 0.86 vs. 1.48, P = 0.041, respectively). Inverse linear correlations were evident between SI norm and ADC in both neoplastic and benign osteoporotic fractures (r = -0.45 and -0.61, respectively). The optimal cut-off values for diagnosis of neoplastic fracture were SI norm of 3.0 in DW-SSFP with the sensitivity and specificity of 90.4% (95% confidence interval [CI]: 81.0-99.0) and 95.3% (95% CI: 90.0-100.0), respectively, and ADC of 1.3 in DW-EPI with the sensitivity and specificity of 90.5% (95% CI: 80.0-100.0) and 70.4% (95% CI: 60.0-80.0), respectively. Conclusion: In 3-T MRI, DW-SSFP has comparable sensitivity and specificity to DW-EPI in differentiating the neoplastic vertebral fracture from the benign osteoporotic vertebral fracture.

An Investigation of Fracture Mechanism of Spheroidal Graphite Cast Iron by Acoustic Emission Method (AE방법에 의한 구상화흑연(球狀化黑鉛) 주철재의 파괴기구 구명(究明))

  • Kim, S.C.;Ham, K.C.;Oh, B.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.6 no.2
    • /
    • pp.17-36
    • /
    • 1987
  • In this experimental research, fracture mechanisms of spheroidal graphite cast iron (As Cast, annealed and normalized) were investigated by using Acoustic Emission (AE) technique. In this study, the data (AE signal) are digitized and processed with the 8 bits micro-computer (APPLE II) connected to the AE measuring device without data processing unit. The source of AE signal was estimated by fractography analysis. The results obtained in this experimental study are summarized as follows : For the heterogeneous materials (spheroidal graphite cast iron) with inclusions which may considered as cracks, it is found that low and high AE amplitude appear simultaneously and the load is found to be fluctuated in the final stage of deformation. But the lad is not fluctuated in tension test with low AE amplitude only. AE is measured within elastic region and it is confirmed that 0.2% offset yield load agrees approximately with the load point where AE counts decrease steeply after the point of maximum AE counts.

  • PDF

State Monitoring of Micro-Grooving using AE Signal (AE신호를 이용한 micro-grooving의 상태감시)

  • 이희석;손성민;김성렬;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.332-335
    • /
    • 1997
  • With the advance of precision technique, the optical system is more precise and complex and the machining method of optical element which is composed of micro-grooves is developed. Especially, the method of micro-grooving using diamond tool is used widely owing to many merit, but has problems of damage of surface roughness due to tool wear and tool fracture. This paper deals with state monitoring using AE RMS in the micro-grooving. The change of AE RMS is very small with increment of cutting velocity and depth of cut. In spite of constance magnitude of principal force in machining using diamond tool of tool wear and tool fracture, AE RMS is highly fluctuated. Because changing of cutting state has relevance to surface roughness profile, surface toughness profile is expected using AE RMS.

  • PDF

Interfacial and Nondestructive Evaluation of Single Carbon Fiber/Epoxy Composites by Fiber Fracture Source Location using Acoustic Emission (Acoustic Emission 의 섬유파단 Source Location을 이용한 Carbon Fiber/Epoxy Composites의 계면특성 및 비파괴적 평가)

  • Kong, Jin-Woo;Kim, Jin-Won;Park, Joung-Man;Yoon, Dong-Jin
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.116-120
    • /
    • 2001
  • Fiber fracture is one of the dominant failure phenomena to determine total mechanical properties in composites. Fiber fracture locations were measured by optical microscopic method and acoustic emission (AE) as functions of matrix toughness and surface treatment by the electrodeposition (ED), and then two methods were compared. Two AE sensors were attached on the epoxy specimen and fiber fracture signals were detected with elapsed time. The interfacial shear stress (IFSS) was measured using tensile fragmentation test and AE system. In ED-treated case, the number of the fiber fracture measured by an optical method and AE was more than that of the untreated case. The signal number measured by AE were rather smaller than the number of fragments measured by optical method, since some fiber fracture signals were lost while AE detection. However, one-to-one correspondence between the x-position location by AE and real break positions by optical method was generally established well. The fiber break source location using AE can be a valuable method to measure IFSS for semi- or nontransparent matrix composites nondestructively (NDT).

  • PDF

Tool Wear and Fracture Monitoring through the Sound Pressure in Turning Process (음압을 이용한 선삭작업에서의 마모, 파손 감시)

  • 이성일
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.82-87
    • /
    • 1997
  • In order to make unmanned machining systems with satisfactory performances, it is necessary to incorporate appropriate condition monitoring systems in the machining workstation to provide the required intelligence of the expert. This paper deals with condition monitoring for tool wear and fracture during turning operation. Developing economic sensing and identification methods for turning processes, sound pressure measurement and digital signal processing technique are proposed. The validity of the proposed system is confirmed through the large number of cutting tests.

  • PDF

THE CHANGES OF C-REACTIVE PROTEIN IN THE PATIENTS ASSOCIATED WITH MANDIBULAR FRACTURE (하악골 골절 환자에서의 C-Reactive Protein의 변화)

  • Gwak, Jong-Min;Kim, Chul-Hwan;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • It is well known that concentration of C-reactive protein(CRP) in the serum increase as nonspecific reaction of the various tissue injury. The CRP, synthesized in the hepatocyte, is one of 'acute phase proteins' in the serum. The main signal patterns of this protein are regulated by synthesis of interleukin-I secreted from macrophage in the area of tissue injury. Many studies were performed for quantitative analysis for CRP according to various surgical operation, but the study for fracture patients associated with trauma, especially in mandible, are rare. The mandible fracture have intrinsic danger for infection in oral bacteria associated with open wound in oral cavity, and, are difficult for detection of tissue reaction between surgical swelling and infection by facial swelling. In this study, quantitative analysis for CRP associated tissue injury in mandibular fracture and surgical intervention was done, the results were as follows: 1. After initial mandibular trauma, the value of serum CRP diminished sequentially, most high value was presented in post-traumatic 2 days. 2. The CRP was diminished significantly 2 days after surgical intervention, and maintained normal value in 5 days after surgery. 3. The change of CRP are higher value in surgical intervention than initial trauma, it suggested that tissue injury from surgery was severe than trauma. 4. The high value of CRP was obtained in mandibular fracture combined soft tissue injury than no associated soft tissue injury. 5. In measurement of CRP according to surgical approach, highest serum value in patients of combined intra-oral and extra-oral approach was showed, and intra-oral approach, extra-oral approach, in sequential orders. 6. The CRP value are more higher in patient of 2 fracture site than only one fracture site. From the results obtained in this study, CRP has showed different values in mandibular fracture associated with severity of tissue injury and surgical intervention, and quantitative analysis of CRP value in serum can be applied to the clinical management of mandibular fracture.

Condition Monitoring of Micro Endmill using C-means Algorithm (C-means 알고리즘을 이용한 마이크로 엔드밀의 상태 감시)

  • Kwon Dong-Hee;Jeong Yun-Shick;Kang Ik-Soo;Kim Jeon-Ha;Kim Jeong-Suk
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.162-167
    • /
    • 2005
  • Recently, the advanced industries using micro parts are rapidly growing. Micro endmilling is one of the prominent technology that has wide spectrum of application field ranging from macro to micro parts. Also, the method of micro-grooving using micro endmilling is used widely owing to many merit, but has problems of precision and quality of products due to tool wear and tool fracture. This study deals with condition monitoring using acoustic emission(AE) signal in the micro-grooving. First, the feature extraction of AE signal directly related to machining process is executed. Then, the distinctive micro endmill state according to the each tool condition is classified by using the fuzzy C-means algorithm, which is one of the methods to recognize data patterns. These result is effective monitoring method of micro endmill state by the AE sensing techniques which can be expected to be applicable to micro machining processes in the future.

  • PDF

Influence of strain rate on the acoustic emission signal characteristics in corrosive environment (부식환경하에서 음향방출신호 특성에 미치는 변형률속도의 영향)

  • Yu, Hyo-Seon;Jeong, Se-Hui
    • Korean Journal of Materials Research
    • /
    • v.5 no.1
    • /
    • pp.12-21
    • /
    • 1995
  • The study was performed to study the effects of strain rate on acoustics emission( AE) during bulging test in corrosive environmentsynthetic sea water. The strain rates used were in the range $4 \times 10^{-6}S^{-1}$ to $1 \times 10^{-4} \times S^{-1}$ and the parameters used to evaluate AE signal characteristics were AE hit and amplitude. It can be observed that the cumulative AE hit and average amplitude during fracture process increase highly at decreasing strain rates while the equivalent fracture strain and the crack length of circumferencial direction become decrease. The peak point of AE signal characteristic parameters approach to the first half of test. When the average amplitude per unit equivalent fracture strain was above 20dB, it was definitly observed stress corrosion cracking phenomena. Additional, we knew that the AE test had the possibility to evaluate SCC susceptibility with various strain rates.

  • PDF