• Title/Summary/Keyword: Fracture Limit

Search Result 337, Processing Time 0.032 seconds

Rock Mass Stability of the Buddha Statue on a Rock Cliff using Fracture Characteristics and Geological Face-Mapping (마애불 암반의 단열특성과 지질맵핑을 이용한 안정성 해석)

  • Ihm, Myeong Hyeok
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.539-544
    • /
    • 2023
  • The subject of this study is the Maae Buddha statue in granodiorite of the Mesozoic Cretaceous period, which is concerned about stability as a standing stone cultural property located in ◯◯-dong, Gyeongsangbuk-do. For stability analysis, three-dimensional face mapping, geological properties of joints, three-dimensional scanning, ultrasonic velocity, polarization microscopy, electron microscopy analysis and XRD analysis were performed. In addition, the safety factor of the Maaebul was calculated by analyzing the damage status investigation, stereographic projection analysis, rock classification, and limit equilibrium analysis. The types and scales of damage and possible collapse by section depend on the degree of weathering of the rock and the orientation and characteristics of the joints, but wedge-failure and toppling-failure are expected to be small-scale. The safety factor of Maaebul in dry and wet conditions is less than 1.2, so stability is concerned. The types of damage were mainly observed, such as exfoliation, cracking, granular decomposition, and vegetation growth. The Maaebul rock is granodiorite, and the surface discoloration materials are K, Fe, and Mg. The 4 sets of joints are developed, J1 is tensile joint and the others are shear joint. The uniaxial compressive strength estimated by ultrasonic exploration is 514kgf/cm2, which corresponds to most soft rocks and some weathered rocks. Rock classification(RMR) is estimated to be grade 5, very poor rock mass. These technique along with the existing methods of safety diagnosis of cultural properties are expected to be a reasonable tool for objective interpretation and stability review of stone cultural properties.

THE EFFECT OF CYCLIC LOADING ON THE RETENTIVE STRENGTH OF FULL VENEER CROWNS (반복 하중이 Full veneer crown의 유지력에 미치는 영향에 관한 연구)

  • Kim, Ki-Youn;Lee, Sun-Hyung;Chung, Hun-Young;Yang, Jae-Ho;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.583-594
    • /
    • 2000
  • Dislodgement of a crown or extension bridge and the loosening of a retainer of a bridge is a serious clinical problem in fixed restoration. Generally these problems are considered to be associated with deformation of the restoration. During biting, the restoration is subjected to complex forces and deforms considerably within the limit of its elasticity. Deformation of the restoration under the occlusal force induces excessive stress in the cement film, which then leads to the cement fracture. Such a fracture may eventually cause loss of the restoration. Because most of the past retention tests for full veneer crown were done without fatigue loading, they were not exactly simulating intraoral environment. And the purpose of this study was to evaluate the effect of cyclic cantilever loading on the retentive strength of full veneer crowns depending on different type of cements and taper of prepared abutment. Steel dies with $8^{\circ}\;or\;16^{\circ}$ convergence angle were fabricated through milling and crowns with the same method. These dies and crowns were divided into 8 groups. Group 1 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 2 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 3 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 4 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 5 : $16^{\circ}$ taper die, cementation with Panavia 21, without loading Group 6 : $16^{\circ}$ taper die, cementation with Panavia 21, with loading Group 7 : $8^{\circ}$ taper die, cementation with Panavia 21 without loading Group 8 : $8^{\circ}$ taper die, cementation with Panavia 21, with loading After checking the fit of die and crown, the luting surface of dies and inner surface of crowns were air-abraded for 10 seconds. The crowns were cemented to the dies, with cements mixed according to the manufacturer's recommendations. A static load of 5kg was then applied for 10 minutes with static loading device. Twenty-four hours later, group 1, 3, 5, 7 were only thermocycled, group 2, 4, 6, 8 were subjected to cyclic loading after thermocycling. Retentive tests were performed on the Instron machine. From the finding of this study, the following conclusions were obtained 1. Panavia 21 showed significantly higher retentive strength than zinc phosphate cement for all groups (p<0.05). 2. There was a significant difference in the retentive strength between $8^{\circ}\;and\;16^{\circ}$ taper for zinc phosphate cement(p<0.05), but no significant difference for Panavia 21 (p>0.05). 3. Cyclic loading significantly decreased the retentive strength for all groups(p<0.05). 4. For zinc phosphate cement, there was 35% reduction of the retentive strength after loading in the $16^{\circ}$ taper die, 25% in the $8^{\circ}$ taper die, and for Panavia 21, 21% in the $16^{\circ}$ taper die, 18% in the $8^{\circ}$ taper die.

  • PDF

Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis (임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구)

  • Eom, Tae-Gwan;Suh, Seung-Woo;Jeon, Gyeo-Rok;Shin, Jung-Wook;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment.

Influence of Tightening Torque on Implant-Abutment Screw Joint Stability (조임회전력이 임플랜트-지대주 나사 연결부의 안정성에 미치는 영향)

  • Shin, Hyon-Mo;Jeong, Chang-Mo;Jeon, Yonung-Chan;Yun, Mi-Jeong;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.396-408
    • /
    • 2008
  • Statement of problem: Within the elastic limit of the screw, the greater the preload, the tighter and more secure the screw joint. However, additional tensile forces can incur plastic deformation of the abutment screw when functional loads are superimposed on preload stresses, and they can elicit the loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum preload that will maximize fatigue life and simultaneously offer a reasonable degree of protection against loosening. Another critical factor in addition to the applied torque which can affect the amount of preload is the joint connection type between implant and abutment. Purpose: The purpose of this study was to evaluate the influence of tightening torque on the implant-abutment screw joint stability. Material and methods: Respectively, three different amount of tightening torque (20, 30, and 40 Ncm) were applied to implant systems with three different joint connections, one external butt joint and two internal cones. The initial removal torque value and the postload (cyclic loading up to 100,000 cycles) removal torque value of the abutment screw were measured with digital torque gauge. Then rate of the initial and the postload removal torque loss were calculated for the comparison of the effect of tightening torques and joint connection types between implant and abutment on the joint stability. Results and conclusion: 1. Increase in tightening torque value resulted in significant increase in initial and postload removal torque value in all implant systems (P < .05). 2. Initial removal torque loss rates in SS II system were not significantly different when three different tightening torque values were applied (P > .05), however GS II and US II systems exhibited significantly lower loss rates with 40 Ncm torque value than with 20 Ncm (P < .05). 3. In all implant systems, postload removal torque loss rates were lowest when the torque value of 30 Ncm was applied (P < .05). 4. Postload removal torque loss rates tended to increase in order of SS II, GS II and US II system. 5. There was no correlation between initial removal torque value and postload removal torque loss rate (P > .05).

The Contents and Satisfation of Home Care Progral Delivered by Seoul Nurses Association (서울시 간호사회 가정간호시범사업 서비스 내용 및 만족도 분석)

  • Lim, Nan-Young;Kim, Keum-Soon;Kim, Young-lm;Kim, Kwuy-Bun;Kim, Si-Hyun;Park, Ho-Ran
    • The Korean Nurse
    • /
    • v.36 no.1
    • /
    • pp.59-76
    • /
    • 1997
  • The purposes of this study were to identify the contents and satisfaction level of the patients received home care service, and to compare the differences of the contents by the characteristics of the patients. Seventy eight patients received home care service from 1st Jan. to 30th Sept., 1996 were data-collected to analyze the contents and outcomes of home care service. Sixty-nine patients currently receiving home care service were participated to evaluate the satisfaction level of home care service. The data were analyzed using mean, standard deviation, $x^2$ test, and ANOVA by SPSS $PC^+$ program. The findings of this study were as follow : 1. The contents & outcomes of home care service 1) The mean age of the subjects was 64.4 years: 58% of them were female. Those who living in Seoul were 83% and the rest of the subjects was living in Kyung-Gi. 2) The subjects who had one diagnosis were 41%. Over 60% of them had the disease of neurologic & sensory system. 3) The mean number of visit was 6. Only one visit was 22%. The mean time of care was 79 minutes. Duration of visit from 31 minutes to 60 minutes were 47 %. The subjects who terminated the visit because of death were 67.3%. 62% of the persons who referred them to the home care service were nurses. 4) The pain after the service was more relieved than before. The amounts of intake, the degree of bed sore, edema & fracture after the service were more improved than before. Health status after the service was improved in general. 5) There were significant differences between initial and last conscious level in tracheostomy care & oxygen inhalation care. There was significant difference between initial and last degree of activity in blood sugar check. 6) There were significant differences on the number of visit in assessment of the status, evaluation & observation, vital sign check, skin care, injection, medication, bed sore care, colostomy care, relaxation therapy for pain relief, patient education, family care, exercise therapy, position change, supply of disinfected equipments and infection control. There were significant differences on visiting time in nasogastric tube care, drainage tube care and oxygen inhalation care. 2. The satisfaction level of home care service 1) 50% were male. Over 60 years of the subjects was 61 %. Those who living in Seoul were 82%. 2) The subjects who had one or two diagnosis were 32% respectively. 55% of the persons who referred them to the home care service were nurses. 3) Total level of satisfaction of home care service was very high. 4) The older the age, the higher the satisfaction level. The larger the number of visit, the higher the satisfaction level. 5) The subjects who were in cloudy state were higher level of satisfaction than in alert or coma state. The subjects whose activity were normal or who needed assistance were higher level of satisfaction than bedridden or immobilized subjects. These findings suggested that the patients had substantial need for posthospital care. They tended to be elderly and to have experienced the wide range of health problems associated with aging, chronicity, including limitations in activities, and other serious health problems. So, the nationwide home care systems beyond the limit of demonstration program by local association and the development of the effective financial system of home based health care are necessary for the clients who are in need of home care.

  • PDF

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

A Study on the Traumatic Teeth Damage of Children (어린이의 외상성 치아손상에 관한 연구)

  • Yoo, Su-Min;Park, Ho-won
    • Journal of dental hygiene science
    • /
    • v.4 no.1
    • /
    • pp.21-25
    • /
    • 2004
  • In modern times, children's trauma is increasing every year because of car accidents and life environment changes. There is a limit to prevent traumatic damage for oral cavity organization. The fundamental data of trauma treatment and prevention will be presented through the survey and analysis of traumatic teeth damage. I examined 113 patients from Oct. 4th, 2000 to Feb. 27th, 2004 at Dept. of Children's Dental Clinic, Kangnung National University. The results are as follows. (1) The trauma frequency of male subjects is higher than that of female at a rate of 2.05:1. The average age is 5.27 for men and 5.27 for women. The highest percentage of trauma patients is among 2 year old children. It is 21.2%. (2) A patient survey was taken at a trauma treatment hospital. On the first day 34.4% of the patients had come to receive treatment of their first set of teeth. However, after a week, 38.8% of the patients had received treatment on their permanent teeth. (3) As a result of falling, 59% of patients needing treatment on their first set of teeth. 55.1% of patients is permanent teeth. As a result of bump against physical solid, 26.6% of patients is the first set of teeth and 26.5% of patients is permanent teeth. (4) Teeth damage happened at home. 42.1% were male. 35.1% were female. According to trauma, 59.4% of teeth damage happened at home. 28.6% of permanent teeth damage happened at school or kindergarten. (5) According to trauma, the number of teeth damaged was in the first set of teeth are as follows: 56.3%, one-31.3%, three or four-6.3% each. For permanent teeth: two-46.9%, one-28.6%, four over-16.3% and three-8.2%. Over four teeth is larger number for permanent teeth. (6) 56% of first set of teeth patients and 43.4% of permanent teeth patients were male. 56.8% of first set of teeth patients and 43.2% of permanent teeth were female. Trauma happened to both male and female frequently in the first set of teeth. (7) Most of the tooth damage which was in the first set of teeth and permanent teeth was done to the upper jaw. 75% of patients are the first set of teeth. 63.8% of patients are permanent teeth. Trauma is very high in the two mid teeth of the upper jaw. (8) According to trauma survey, 30.2% is from impulse. 28.0% is from crown fracture, 14.7% is from depression. 8.9% is from concussion. 7.1% is from full dislocation of a joint. 2.2% of patients are extrusion. 1.8% is from displacement. According to teeth damage trauma, 35.8% is pulse in the first set of teeth. The breaking of the crown of a tooth happened a lot in permanent teeth. (9) According to data, 43.2% of teeth damage in the first set of teeth goes without treatment. In permanent teeth, it is 38.9%. After treatment, 22.0% of first set of teeth treatment requires a dental pulp treatment. In permanent teeth, which is used for temporary acid etching resin restoration.

  • PDF