• Title/Summary/Keyword: Fracture, closed

Search Result 262, Processing Time 0.027 seconds

Chopart Joint Fracture and Dislocation: A Report of Three Cases (Chopart 관절 골절 및 탈구: 3예 보고)

  • Kim, Sung-Hyun;Suh, Jae Wan;Park, Hyun-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.3
    • /
    • pp.120-126
    • /
    • 2018
  • Chopart joint fracture and dislocation are rare injuries compared with other joint injuries with various clinical manifestations. Moreover, there is a lack of knowledge of the radiological findings of the joints, and thus, the extent of joint ligament damage may be underestimated, leading to improper treatment. This paper reports three cases of Chopart joint injury and seeks to reconsider the importance of Chopart joint evaluation and treatment.

Hemorrhagic Shock in a Patient with a Morel-Lavallée Lesion Combined with Active Arterial Bleeding without Fracture

  • Lim, Eic Ju;Oh, Jong-Keon;Cho, Jae-Woo;Sakong, Seungyeob;Cho, Jun-Min
    • Journal of Trauma and Injury
    • /
    • v.34 no.1
    • /
    • pp.61-65
    • /
    • 2021
  • A Morel-Lavallée lesion is a closed degloving injury caused by traumatic separation of the skin and subcutaneous tissue from the underlying fascia. However, since physicians tend to focus on treating the bone fracture, hemodynamic instability accompanying a Morel-Lavallée lesion can sometimes be overlooked. We report the case of a hemodynamically unstable 73-year-old man who had a Morel-Lavallée lesion of the thigh, but no femur fracture. Angiography showed active bleeding from the muscular branch of the right deep femoral artery, which was then successfully embolized.

Delayed union of a pediatric lunate fracture in the United Kingdom: a case report and a review of current concepts of non-scaphoid pediatric carpal fractures

  • Timothy P. Davis;Elizabeth Headon;Rebecca Morgan;Ashley I. Simpson
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.315-321
    • /
    • 2023
  • Pediatric carpal fractures are rare and often difficult to detect. This paper reviews the current literature on pediatric non-scaphoid carpal fractures, with a case report of a lunate fracture associated with a distal radius and ulnar styloid fracture, managed nonoperatively in a 12-year-old boy. There is lack of consensus regarding the management of these fractures due to the low number of reported cases. A frequent lack of long-term follow-up limits our understanding of the outcomes, but good outcomes have been reported for both nonoperative and operative management. This case report brings attention to the current time period for the definition of delayed union in pediatric carpal fractures, and emphasizes the need for prolonged follow-up for the detection of delayed complications leading to functional impairment.

Chorpart's Dislocation: A Case Report (중족근 관절 탈구: 1예 보고)

  • Choi, Jun-Weon;Choi, Joon-Choil;Na, Hwa-Yeop;Shim, Dong-Joon;Kim, Young-Ho;Lee, Sang-Ho;Cho, Hyoung-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.121-124
    • /
    • 2005
  • The midtarsal joint which consists of the talonavicular and calcaneocuboid joints lies transversely across the medial and lateral arches of the foot. Complete dislocation of this joint unassociated with fracture is extremely rare. A 36 year-old male who was injured by motor vehicle accident came to help for his left midfoot pain and deformity. We misdiagnosed as subtalar dislocation. Closed reduction was performed. We reviewed initial and post-reduction X-rays, and then we diagnosed as Chopart's dislocation. CT scan was taken; it showed fracture of the anterior process of the calcaneous.

  • PDF

Development of a Closed-die Design with Backpressure to Forge Rotating Scrolls (압축기용 구동스크롤의 밀폐형 배압 금형 개발)

  • Kim, Y.B.;Jung, K.H.;Lee, S.;Kim, E.;Lee, J.;Choi, D.S.;Lee, G.A.
    • Transactions of Materials Processing
    • /
    • v.22 no.4
    • /
    • pp.183-188
    • /
    • 2013
  • Scroll compressors are widely used in air conditioning systems and in automobiles due to their low pressure loss, minimal vibrations, and light-weight. Open-die forging with back pressure is used to forge the rotating scroll, and it requires special care since the forging die can be severely damaged at the fixed end of the spiral cavity similar to a fracture of a cantilever beam. To overcome the inevitable weakness of the forging die due to such damage, an innovative design is necessary. In this study, structural analysis using the finite element method was conducted to determine the reason for the fracture of the forging die. A novel design to avoid stress concentrations and vertical deflection, causing serious damage to the die, is suggested.

The measurement of nose dimensions through the three-dimensional reformation images after nasal bone fracture

  • Jang, Seung Bin;Han, Dong Gil
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 2019
  • Background: After closed reduction, patients are sometimes concerned that their external nasal shapes have changed. The aim of this study was to investigate and explain changes in nasal shape after surgery through objective photogrammetric anthropometry measurements taken through three-dimensional (3D) reformed computed tomography (CT) images. Methods: Our study included 100 Korean patients who underwent closed reduction of isolated nasal bone fracture from January 2016 to June 2017. Using the ruler tool in Adobe Photoshop CS3, we measured preoperative and postoperative nasal base heights, long nostril axis lengths, both nasal alar angles, and amount of nasal deviation through the 3D reformation of soft tissue via CT scans. We then compared the dimension of nose. Results: The amount of postoperative correction for nasal base height was 1.192 mm. The differences in nostril length between each side were found to be 0.333 mm preoperatively and 0.323 mm postoperatively. The differences in the nasal alar angle between each side was $1.382^{\circ}$ preoperatively and $1.043^{\circ}$ postoperatively. The amount of nasal deviation was found to be 5.248 mm preoperatively and 1.024 mm in postoperatively. Conclusion: After the reduction of nasal bone fractures, changes in nasal dimensions were noticeable in terms of nasal deviation but less significant in nasal tips, except for changes in nasal alar angles, which were notable.

Evaluation of Axial Behavior of Strengthened Columns according to Different Peripheral Closed Hoops in Jacket Section (확대단면에서 폐쇄형 외부 띠철근 배근 방법에 따른 보강기둥의 중심축하중 거동 평가)

  • Hwang, Yong-Ha;Yang, Keun-Hyeok;Sim, Jae-Il;Choi, Yong-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.139-146
    • /
    • 2019
  • This study examined the effect of various arrangement methods for forming peripheral closed hoops in the jacket section on the axial behavior of section enlargement strengthening columns. Four types of peripheral closed hoops arranged in the jacket section were prepared as follows: 1) Closed connection of prefabricated bar units (column P); 2) V-clip installation across the overlapped legs of channel-type bars (column V); 3) Use of glass fiber mesh for an alternative of steel bars (column F); and 4) combination of prefabricated bar units and glass fiber mesh (column PF). The V-clip is designed to form the closed hoops in the jacket section using the overlapped channel-type bars, preventing the opening of the channel bar legs. The glass fiber mesh is to examine the feasibility to apply for closed hoops in the jacket section as an alternative for steel bars, considering the easy construction. In the jacket section of all the strengthened columns, V-ties were arranged for supplementary ties, avoiding the interruption of the existing column. The axial stiffness and strength of the strengthened columns were insignificantly affected by the arrangement methods of closed hoops in the jacket section. The axial ductility ratio of the strengthened columns P, V, and PF was enhanced more than twice of that measured in the non-seismic existing column. However, the column F exhibited a lower ductility than the other strengthened columns because of the fracture of the mesh at the ultimate strength of the column. The V-clip approach was favorable to enhance the ductility of the strengthened column, preventing the opening of the legs of channel-type bars.

Usefulness of Indirect Open Reduction and External Fixation in Algorithm Oriented Treatment of Nasal Fracture (비골골절 치료 시 간접 관혈적 정복술 및 외고정술의 유용성)

  • Park, Ki Rin;Chung, Kyu-Jin;Kim, Yong-Ha
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.2
    • /
    • pp.81-88
    • /
    • 2013
  • Background: To suggest the need of more aggressive reduction techniques than closed reduction (CR) technique in nasal fracture treatment, we identified the usefulness of algorithm oriented treatment of nasal fracture that includes indirect open reduction (IOR) and external fixation (EF) as well as the CR. Methods: We compared the clinical course of the group A (n=128) where only the CR was performed regardless of the pattern of the nasal fracture and the group B (n=127) where algorithm oriented treatment including IOR and EF as well as CR was performed depending on the pattern of nasal fracture. And the degree of postoperative pain after CR and IOR technique was compared through the dose of analgesics and pain scores. Results: More than 80% of patients were satisfied the result of reduction in both group A and B. Good contour of nasal bone after reduction was showed 71% of group A and 81% of group B without significant difference. Minor (p>0.05) and major (p<0.05) deformity after reduction were less occurred in the group B than group A. Postoperatively, the dose of analgesics was significantly lower after IOR technique than CR technique (53 mg vs. 142 mg) (p<0.05). Conclusion: Algorithm oriented treatment of nasal fracture including IOR and EF as well as CR reduce major deformity after reduction than treatment of CR alone. It is useful to perform the more aggressive reduction techniques such as IOR and EF according to the pattern of fracture in treatment of nasal fracture.

Multiple Rib Fracture: analysis of 100 cases (다발성 늑골골절 치험 100례)

  • Lee, Nam-Soo;Jeong, Hyun-Ki;Sohn, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.411-417
    • /
    • 1979
  • During the period of 4 years from August 1, 1975 to August 1, 1979, authors have experienced 100 cases of multiple rib fractures by nonpenetrating injury at Department of Thoracic Surgery, Paik Foundation Hospital in Seoul, Korea. 1. The ratio of male to female patients with multiple rib fracture was 2.6:1 with male predominance and 84% of the total cases were between 20 and 50 years of age. 2. The most common cause of multiple rib fracture was traffic accident and falls accounted for the next largest group. 3. The most common site of rib fracture was 4th rib to 7th rib level on both hemithorax [52%]. 4. Associated injuries were cerebral contusion in 26%, clavicular fracture in 22%, long bone fracture in 22%, pelvic bone fracture in 10%, and scapular fracture in 8%. 5. Early complications and/or result of the multiple rib fractures were lung contusion in 23 cases, subcutaneous emphysema in 21 cases, hemothorax in 21 cases, hemopneumothorax in 6 cases, and flail chest in 12 cases. 6. The flail chests were managed by strapping the chest with adhesive plaster, external traction of flail segment with towel clip, ventilatory assistance for marginal clinical indications, and in cases of complicated with intrathoracic hemorrhage, wire fixation of flail segment through open thoraco-tomy. 7. The principles of therapy for hemothorax and/or pneumothorax were rapid reexpansion of the lungs by thoracentesis [11%] and closed thoracostomy [22%], but open thoracotomy had to be done on 3 cases because of massive bleeding or intrapleural hematoma and diaphragmatic rupture. 8. The over all mortality was 4% [4 among 100 cases] and the cause of all deaths was head injury.

  • PDF

Use of Minimally Invasive Plate Osteosynthesis for Tibial Diaphyseal Fracture in Three Dogs (경골 골간 골절에서의 최소 침습적 금속판 고정술의 이용 3례)

  • Heo, Su-Young;Lee, Ki-Chang;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.339-343
    • /
    • 2012
  • Three dogs were presented with diaphyseal fracture of the tibia following separate motor vehicle accidents. On physical and orthopedic examinations, the dogs were noted to have soft-tissue swelling and a closed fracture in these tibia sites. Radiographs revealed a simple, short oblique fracture (case 1), a comminuted, spiral fracture (case 2), and a simple, spiral fracture (case 3) in tibia. Minimally invasive percutaneous plate osteosynthesis (MIPO) using a veterinary cuttable plate or locking plate was applied for the treatment of these fractures. The surgery was successful, and the fractures healed without any complications by 7 weeks (case 1), 10 weeks (case 2) and 8 weeks (case 3) after surgery. Our patients showed fast bone healing times and early weight-bearing during the treatment of their tibia fractures. Therefore, MIPO was a useful procedure for diaphyseal fracture of the tibia in veterinary orthopedics.