• 제목/요약/키워드: Fractional collection efficiency

검색결과 6건 처리시간 0.015초

승용차용 정전 필터의 미세 입자 포집 특성 (Collection Performance of an Electret Cabin Air Filter for Fine Particles)

  • 지준호;강석훈;김동철;황정호;윤웅섭;배귀남
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1650-1658
    • /
    • 2001
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the fractional collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using highly monodisperse particles ranging from 0.02 to 0.6 $\mu\textrm{m}$ in diameter at three different charging states: singly charged, uncharged, and equilibrium charged. The face velocity was varied from 2.4 to 20.4 crus. It was fecund that the fractional efficiency curve fur singly charged particles shows a typical trend that the collection efficiency is minimum at about 0.3 $\mu\textrm{m}$ in diameter. The fractional efficiency of equilibrium charged particles were not severely varied with the particle diameter. The collection efficiency curve fur uncharged particles has a minimum near 0.1 $\mu\textrm{m}$ in diameter. Another experiment was conducted for a cartridge filter to examine the effect of charge depletion on the collection efficiency in a cabin air filter. The result shows that the charge depletion of the cartridge filter can significantly lower the collection efficiency.

승용차용 Cabin Air Filter의 성능 (Performance of Automotive Cabin Air Filter for Passenger Cars)

  • 박영옥;구철오;임정환;김홍룡;손재익
    • 한국대기환경학회지
    • /
    • 제12권3호
    • /
    • pp.279-287
    • /
    • 1996
  • Pressure drop and fractional collection efficiency of automotive cabin air filters were examined to obtain the basic data for the development of high performance domestic cabin air filters. Pressure drop of MA-V100 was higher than that of VF-V100, and it increased with the air flow rate. VF-V100 had longer time to rise the critical pressure drop than that MA-V100 had. Total collection efficiency of MA-V100 for initial and dust loaded conditions was higher than that of VF-V100. Also, fractional collection efficiency of MA-V100 for the fine particles was higher than that of VF-V100. Particla size distribution for the minimum collection efficiency ranged from 0.02 $\mu$m to 0.04 $\mu$m for MA-V100 and it ranged from 0.02 $\mu$m to 0.15 $\mu$m for VF-V100.

  • PDF

원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교 (Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System)

  • 김상도;박영옥;강용
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

산업용 필터백의 구조에 따른 여과성능 특성 (Filtration Performance Characteristics according to Filter Bag Structure for Application of Industries)

  • 전성민;;이강산;이재랑;김광득;박영옥
    • 한국대기환경학회지
    • /
    • 제32권4호
    • /
    • pp.384-393
    • /
    • 2016
  • In this study, two kinds of industrial filter bags were tested for their filtration performance to apply the existing bag filter systems. Experimental variables were examined for pressure drop, cleaning interval, residual pressure drop, cleaning efficiency, fractional grade efficiency, total collection efficiency according to the filter bag structure. According to these results, the filter bags tested in this study demonstrated good performance in dust collection. This was also true for the double surface filter bag. The lifetime was longer than the round type filter bag because the filtration area was more than 1.6 times wider and the filter quality factor was much higher. Therefore, double surface filter bags are suggested to be used in order to increase filtration performance of the bag filter systems.

3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산 (Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis)

  • 김호경;조민국;정민호;손철순;황성진;고종수;조효성
    • Journal of Radiation Protection and Research
    • /
    • 제30권2호
    • /
    • pp.69-75
    • /
    • 2005
  • 기체전자증폭기(GEM, gas electron multiplier)는 동박이 양면으로 도포된 절연기관에 미세구멍배열을 형성한 박막으로 기존의 기체형 방사선 검출기의 미약한 방사선 신호를 증폭하기 위해 널리 사용되어지고 있다. 미세구멍 내부에 강한 전기장을 형성함으로써 이 내부로 유입되는 전자에 충분한 에너지를 전달, 전자사태를 유도하는 원리를 이용한다. 따라서 GEM의 특성은 GEM을 포함한 방사선 검출기에 인가되는 전압 즉, 전기장의 분포에 의해 결정된다. 따라서 올바르지 못한 전기장의 분포에 대해서는 신호 전자가 수집전극으로 향하지 못하고, GEM의 상 하단의 전극으로 이동, 신호의 손실을 초래할 수도 있다. 본 논문에서는 GEM의 가장 중요한 성능 지표 중 하나인 1차 전자수집효율(primary electron collection efficiency)을 계산하였다. 방사선에 의해 발생된 전자는 전기력선을 따라서만 움직인다는 가정 하에, GEM의 단위 구조에 대해 표류전극에서의 전기력선의 수에 대한 수집전극에서의 전기력선의 수의 비로 전자수집효율을 계산하였다. 전기력선의 계산은 3차원 유한요소법을 이용하여 계산하였다. 본 논문에서 사용한 방법은 가장 이상적인 상황으로 국한되지만, GEM의 설계 및 최적 운전변수 도출에 유용하게 사용될 수 있을 것이다.

소형 자동차 페인트 도장부스에서 발생하는 점착성 paint aerosol 처리장치에서 제거성능 (Removal Performance of Sticky Paint Aerosol Control System Generated from Small Scale Car Paint Overspray Booth)

  • 이재랑;;전성민;이강산;손종렬;박영옥
    • 한국대기환경학회지
    • /
    • 제31권1호
    • /
    • pp.54-62
    • /
    • 2015
  • Small scale paint overspray booths are being operated nationwidely, for repair of passenger car body parts. paint aerosols are emitted from the paint overspray booth in operations. In paint overspray booth operations without ventilation system and air pollutants collection unit, it may land on nearby equipment. In this study a removal of sticky paint aerosol for application of the small-scale overspray paint booth. it's cause the surface of filter bag from generated sticky paint aerosol. To remove adhesion of paint aerosol the agglomerating agents are injected and mixed with sticky paint aerosols prior to reach the filter bag. The paint spray rate was set as $10{\pm}5g/min$ from air-atomized spray guns in the spray booth, injection rate of agglomerating was $10{\pm}5g/min$ in the mixing chamber. The filtration velocity including air pollutants varied from 0.2 m/min to 0.4 m/min. Bag cleaning air pressure was set as $5.0kg_f/min$ for detaching dust cake from surface of filter bag. Bag cleaning interval at the filtration velocity of 0.2 m/min was around 3 times longer than that of the 0.4 m/min. The residual pressure drop maintained highest value at the highest filtration velocity. Fractional efficiency of 99.952%~99.971% was possible to maintain for the particle size of 2.5 microns. Total collection efficiency at the filtration velocity of 0.2 m/min was 99.42%. During this study we could confirm high collection efficiency and long cleaning intervals for the test with filtration velocity of 0.2 m/min indicating an optimal value for the given dimensions of the test unit and test operating conditions.