• Title/Summary/Keyword: Fraction images

Search Result 218, Processing Time 0.03 seconds

INTERSTELLAR DUST IN M51 FROM IRC IMAGES

  • Egusa, Fumi;Sakon, I.;Onaka, T.;Matsuhara, H.;Arimatsu, K.;Suzuki, T.;Wada, T.;The IRC team, The IRC team
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.253-256
    • /
    • 2012
  • We present the IRC images of M51, a pair of interacting galaxies. Given the high angular resolution (7.4") and the wide field of view (~ 10') covering almost the entire M51 system, we investigate dust properties and their connection to the spiral arm structure. We have applied image-filtering processes including the wavelet analysis to the N3 image, which traces the total stellar mass best among the IRC bands. From this filtered image, the center, arm, and interarm regions are defined. A color, or flux ratio among the MIR bands, has been measured at each pixel (3.7" in size). We find a wide variety of S7/S11 with a difference between arm and interarm regions. We also find that at some positions S11 seems to be higher than predicted by MW dust models. Estimated contributions from the stellar continuum and gas emission lines to the band are not enough to explain this discrepancy. From these results, we deduce that the PAH ionization condition and its fraction to the total dust mass in M51 are different from those in MW.

IMAGING SPECTROMETRY FOR DETECTING FECES AND INGESTA ON POULTRY CARCASSES

  • Park, Bo-Soon;William R.Windham;Kurt C.Lawrence;Smith, Douglas-P
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3106-3106
    • /
    • 2001
  • Imaging spectrometry or hyperspectral imaging is a recent development that makes possible quantitative and qualitative measurement for food quality and safety. This paper presents the research results that a hyperspectral imaging system can be used effectively for detecting fecal (from duodenum, cecum, and colon) and ingesta contamination on poultry carcasses from the different feed meals (wheat, mile, and corn with soybean) for poultry safety inspection. A hyperspectral imaging system has been developed and tested for the identification of fecal and ingesta surface contamination on poultry carcasses. Hypercube image data including both spectral and spatial domains between 430 and 900 nm were acquired from poultry carcasses with fecal and ingesta contamination. A transportable hyperspectral imaging system including fiber optically fabricated line lights, motorized lens control for line scans, and hypercube image data from contaminated carcasses with different feeds are presented. Calibration method of a hyperspectral imaging system is demonstrated using different lighting sources and reflectance panels. Principal Component and Minimum Noise Fraction transformations will be discussed to characterize hyperspectral images and further image processing algorithms such as image band ratio of dual-wavelength images and its histogram stretching with thresholding process will be demonstrated to identify fecal and ingesta materials on poultry carcasses. This algorithm could be further applied for real-time classification of fecal and ingesta contamination on poultry carcasses in the poultry processing line.

  • PDF

On the Formation of Red-sequence Galaxies in Rich Abell Clusters at z ${\lesssim}$ 0.1

  • Sheen, Yun-Kyeong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.36.2-36.2
    • /
    • 2012
  • The aim of this study was to explore the role of galaxy mergers on the formation and evolution of galaxies in galaxy clusters. For this purpose, u', g', r' deep optical imaging and multi-object spectroscopic observation were done for four rich Abell clusters at z ${\lesssim}$ 0.1 (A119, A2670, A3330, and A389) with a MOSAIC 2 CCD and Hydra spectrograph mounted on a Blanco 4-m telescope at CTIO. With the deep images, we found that about 25% of the bright red-sequence galaxies exhibited post-merger signatures in a cluster environment. This fraction was much higher than what was expected from the results of the field environment (-35%, van Dokkum 2005) and significantly low on-going merger fractions (about one-fifth of the field) appeared in the clusters currently. Taking advantage of the most up-to-date semi-analytic model, the results indicate that most of the post-merger galaxies may have carried over their merger features from their previous halo environment. All the brightest cluster galaxies in our cluster samples revealed faint structures in their halos as well as multiple nuclei in their centers seen in the deep optical images. We suggest that the mass of the BCGs increased mainly though major mergers at recent epochs based on their post-merger signatures and the large gaps in the total magnitudes between the BCGs and the second-rank BCGs. A UV bright tidal tail and tidal dwarf galaxy (TDG) candidates around the post-merger galaxy, NGC 4922, were discovered in the outskirts of the Coma cluster using the GALEX UV data. We did two-component stellar population modeling for the TDG candidates and the results indicate that they are an early form of dwarf galaxies frequently found around massive early-type galaxies in clusters. In conclusion, we suggest that the mergers of galaxies are an important driving force behind galaxy formation and evolution in cluster environments even until recent epochs.

  • PDF

Removal of NOx and $SO_2$ from Combustion Flue Gases by Corona Discharge Systems (코로나 방전 시스템을 이용한 연소가스중의 NOx, $SO_2$제거)

  • 박재윤
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.830-835
    • /
    • 1997
  • In this study an experimental investigation has been conducted to remove NOx and SO$_2$simultaneously from a combustion flue gases were consisted of NO-SO$_2$-$CO_2$-$N_2$-O$_2$([NO]o:200ppm and [SO$_2$]o:800ppm) and the injection gases used as radical source gases were NH$_3$-Ar-air and CH$_4$-Ar-air. NOx and SO$_2$removal efficiency and the other by-products were measured by Fourier Transform Infrared(FTIR) as well as SO$_2$, NOx and NO$_2$gas detectors. and SEM images after sampling. The results showed that a significant Nucleating Particle Counter(CNPC) and SEM images after sampling. The results showed that a significant aerosol particle formation was observed during a simultaneous NOx and SO$_2$removal operation in corona radical shower systems. The diameter of aerosol particles was in the range of 0.18 to 3.6${\mu}{\textrm}{m}$ with a maximum fraction of particles at particles diameter of 1${\mu}{\textrm}{m}$. The NOx removal efficiency significantly increased with increasing applied voltage and NH$_3$molecule ratio. The SO$_2$removal efficiency was not significantly effected by applied voltage and slightly increased with increasing NH$_3$molecule ratio. It could be found that it is possible to use CH$_4$for NOx and SO$_2$removal by corona radical shower systems.

  • PDF

Interpretation of Permeation Characteristics and Membrane Transport Models Through Polyamide Reverse Osmosis Membrane (Polyamide 역삼투막의 투과성능과 막 이동 모델의 해석)

  • 김노원;김영길;이용택
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.75-84
    • /
    • 2004
  • In this study, we present a noble study far membrane transport models using chlorine resistance of polyamide RO membranes. Membrane transport mechanism is investigated by the comparison of membrane permeation performance under the continuous and Intermittent operation modes with mixed feed solution containing NaOCl and NaCl. Analysis of permeation performance indicates that solution-diffusion model and preferential adsorption-capillary flow model are relatively efficient according to operation mode. Under the continuous flow state, mass transfer depends on preferential adsorption-capillary flow model rather than solution-diffusion model. On the other hand, it prefers solution-diffusion model to preferential adsorption-capillary flow model under the stationary state. SEM images of NaOCl treated membrane surfaces strongly support these conclusions. These surface images reveal that NaOCl treated membrane in continuous operation mode exhibits ridge and valley structure in some fraction of the surface area, whereas that in intermittent operation mode shows surface degradation entirely.

Application of Linear Spectral Mixture Analysis to Geological Thematic Mapping using LANDSAT 7 ETM+ and ASTER Satellite Imageries (LANDSAT 7 ETM+와 ASTER영상정보를 이용한 선형분광혼합분석 기법의 지질주제도 작성 응용)

  • Kim Seung Tae;Lee Kiwon
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.6
    • /
    • pp.369-382
    • /
    • 2004
  • The purpose of this study is the investigation of applicability of LSMA(Linear Spectral Mixture Analysis) on the geological uses with different radiometric and spatial types of sensor images such as Terra ASTER and LANDSAT 7 ETM+. As for the actual application case, geologic mapping for mineral exploration using ASTER and ETM+ at the Mongolian plateau region was carried out. After the pre-processing such as the geometric corrections and calibration of radiance, 7 endmembers, as spectral classes for geologic rock types, related to spectral signature deviation for the given application was determined by the pre-surveyed geological mapping information and the correlation matrix analysis, and total 20 images of ASTER and ETM+ were used to LSMA processing. As the results, fraction maps showing individual mineral types in the study area are presented. It concluded that this approach based on LSMA using ETM+ and ASTER is regarded as one of the effective schemes for geologic remote sensing.

Preparing for low-surface-brightness science with the Rubin Observatory: characterisation of LSB tidal features from mock images

  • Martin, Garreth W.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.40.3-41
    • /
    • 2021
  • Minor mergers leave behind long lived, but extremely faint and extended tidal features including tails, streams, loops and plumes. These act as a fossil record for the host galaxy's past interactions, allowing us to infer recent accretion histories and place constraints on the properties and nature of a galaxy's dark matter halo. However, shallow imaging or small homogeneous samples of past surveys have resulted in weak observational constraints on the role of galaxy mergers and interactions in galaxy assembly. The Rubin Observatory, which is optimised to deliver fast, wide field-of-view imaging, will enable deep and unbiased observations over the 18,000 square degrees of the Legacy Survey of Space and Time (LSST), resulting in samples of potentially of millions of objects undergoing tidal interactions. Using realistic mock images produced with state-of-the-art cosmological simulations we perform a comprehensive theoretical investigation of the extended diffuse light around galaxies and galaxy groups down to low stellar mass densities. We consider the nature, frequency and visibility of tidal features and debris across a range of environments and stellar masses as well as their reliability as an indicator of galaxy accretion histories. We consider how observational biases such as projection effects, the point-spread-function and survey depth may effect the proper characterisation and measurement of tidal features, finding that LSST will be capable of recovering much of the flux found in the outskirts of L* galaxies at redshifts beyond local volume. In our simulated sample, tidal features are ubiquitous In L* galaxies and remain common even at significantly lower masses (M*>10^10 Msun). The fraction of stellar mass found in tidal features increases towards higher masses, rising to 5-10% for the most massive objects in our sample (M*~10^11.5 Msun). Such objects frequently exhibit many distinct tidal features often with complex morphologies, becoming increasingly numerous with increased depth. The interpretation and characterisation of such features can vary significantly with orientation and imaging depth. Our findings demonstrate the importance of accounting for the biases that arise from projection effects and surface-brightness limits and suggest that, even after the LSST is complete, much of the discovery space in low surface-brightness Universe will remain to be explored.

  • PDF

Measurement of Pancreatic Fat Fraction by CT Histogram Analysis to Predict Pancreatic Fistula after Pancreaticoduodenectomy

  • Wonju Hong;Hong Il Ha;Jung Woo Lee;Sang Min Lee;Min-Jeong Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.599-608
    • /
    • 2019
  • Objective: To evaluate the effectiveness of computed tomography (CT) Hounsfield unit histogram analysis (HUHA) in postoperative pancreatic fistula (PF) prediction. Materials and Methods: Fifty-four patients (33 males and 21 females; mean age, 65.6 years; age range, 37-89 years) who had undergone preoperative CT and pancreaticoduodenectomy were included in this retrospective study. Two radiologists measured mean CT Hounsfield unit (CTHU) values by drawing regions of interest (ROIs) at the level of the pancreaticojejunostomy site on preoperative pre-contrast images. The HUHA values were arbitrarily divided into three categories, comprising HUHA-A ≤ 0 HU, 0 HU < HUHA-B < 30 HU, and HUHA-C ≥ 30 HU. Each HUHA value within the ROI was calculated as a percentage of the entire area using commercial 3-dimensional analysis software. Pancreas texture was evaluated as soft or hard by manual palpation. Results: Fifteen patients (27.8%) had clinically relevant PFs. The PF group had significantly higher HUHA-A (p < 0.01) and significantly lower mean CTHU (p < 0.01) values than those of the non-PF group. The HUHA-A value had a moderately strong correlation with PF occurrence (r = 0.60, p < 0.01), whereas the mean CTHU had a weak negative correlation with PF occurrence (r = -0.27, p < 0.01). The HUHA-A and mean CTHU areas under the curve (AUCs) for predicting PF occurrence were 0.86 and 0.65, respectively, with significant difference (p < 0.01). The HUHA-A and mean CTHU AUCs for predicting pancreatic softness were 0.86 and 0.64, respectively, with significant difference (p < 0.01). Conclusion: The HUHA-A values on preoperative pre-contrast CT images demonstrate a strong correlation with PF occurrence.

Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports

  • Gustavo Gavazzoni Blume;Luka David Lechinewski;Isabela Pedroza Vieira;Nadine Clausell;Giovana Paludo Bertinato;Paulo Andre Bispo Machado-Junior;Pedro Goulart Berro;Lidia Ana Zytynski Moura;Teresa Tsang
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.1
    • /
    • pp.25-34
    • /
    • 2022
  • BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was conducted in an adult outpatient echocardiography clinic. Experienced sonographers performed the STD and an experienced echocardiographer performed the HH. STD included 2-dimensional images, Doppler and hemodynamics analysis. Hemodynamic assessment was not performed with the HH device because the HH does not include such technology. The images were interpreted by blinded echocardiographers, and the agreement between the reports was analyzed. RESULTS: A total of 108 patients were included; and the concordance for left ventricle (LV) ejection fraction (EF), wall motion score index, LV and right ventricle (RV) function, RV size, and mitral and aortic stenosis was excellent with κ values greater than 0.80. Wall motion abnormalities had good concordance (κ value 0.78). The agreement for LV hypertrophy, mitral and aortic regurgitation was moderate, and tricuspid and pulmonary regurgitation agreements were low (κ values of 0.26 and 0.25, respectively). CONCLUSIONS: In a daily practice scenario with experienced hands, HH demonstrated good correlation for most echocardiography indications, such as ventricular size and function assessment and stenosis valve lesion analyses.

Development of Geometrical Quality Control Real-time Analysis Program using an Electronic Portal Imaging (전자포탈영상을 이용한 기하학적 정도관리 실시간 분석 프로그램의 개발)

  • Lee, Sang-Rok;Jung, Kyung-Yong;Jang, Min-Sun;Lee, Byung-Gu;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.77-84
    • /
    • 2012
  • Purpose: To develop a geometrical quality control real-time analysis program using an electronic portal imaging to replace film evaluation method. Materials and Methods: A geometrical quality control item was established with the Eclipse treatment planning system (Version 8.1, Varian, USA) after the Electronic Portal Imaging Device (EPID) took care of the problems occurring from the fixed substructure of the linear accelerator (CL-iX, Varian, USA). Electronic portal image (single exposure before plan) was created at the treatment room's 4DTC (Version 10.2, Varian, USA) and a beam was irradiated in accordance with each item. The gaining the entire electronic portal imaging at the Off-line review and was evaluated by a self-developed geometrical quality control real-time analysis program. As for evaluation methods, the intra-fraction error was analyzed by executing 5 times in a row under identical conditions and procedures on the same day, and in order to confirm the infer-fraction error, it was executed for 10 days under identical conditions of all procedures and was compared with the film evaluation method using an Iso-align$^{TM}$ quality control device. Measurement and analysis time was measured by sorting the time into from the device setup to data achievement and the time amount after the time until the completion of analysis and the convenience of the users and execution processes were compared. Results: The intra-fraction error values for each average 0.1, 0.2, 0.3, 0.2 mm at light-radiation field coincidence, collimator rotation axis, couch rotation axis and gantry rotation axis. By checking the infer-fraction error through 10 days of continuous quality control, the error values obtained were average 1.7, 1.4, 0.7, 1.1 mm for each item. Also, the measurement times were average 36 minutes, 15 minutes for the film evaluation method and electronic portal imaging system, and the analysis times were average 30 minutes, 22 minutes. Conclusion: When conducting a geometrical quality control using an electronic portal imaging, it was found that it is efficient as a quality control tool. It not only reduces costs through not using films, but also reduces the measurement and analysis time which enhances user convenience and can improve the execution process by leaving out film developing procedures etc. Also, images done with evaluation from the self-developed geometrical quality control real-time analysis program, data processing is capable which supports the storage of information.

  • PDF