Development of head loss coefficient formula at surcharged four-way combining square manhole with variation of inlet flow (유입유량 변화를 고려한 과부하 4방향 사각형 합류맨홀에서의 손실계수 산정식 개발)

  • Jo, Jun Beom;Kim, Jung Soo;Yoon, Sei Eui
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.12
    • /
    • pp.877-887
    • /
    • 2017
  • The energy losses due to surcharged flow at four-way combining manhole, which is mainly installed in the downstream of urban sewer system, is the main cause of inundation in urban area. Surcharged four-way combining manholes form various flow configuration such as straight through, T-type, and four-way manholes depending on variation of inflow discharge in inlet pipes. Therefore, it is necessary to analyze change of energy loss and estimate head loss coefficients at surcharged four-way combining manhole with variation of inflow discharge ratio. The hydraulic experimental apparatus which can change inflow ratios were installed to analyze the flow characteristics at four-way combining manhole. In this study, to calculate the head loss coefficient according to change of the inflow discharge ratios at the surcharged four-way combining square manhole, the discharge conditions of 40 cases which the inflow ratios of each inlet pipe were changed by 10% interval was selected. The head loss coefficient at surcharged square manhole showed the lowest value of 0.40 at the straight manhole and the highest value of 1.58 at the $90^{\circ}$ junction manhole. In the combining manholes (T-type and four-way), the head loss coefficients were calculated more higher as the lateral flow rate was biased. The contour map of head loss coefficient range was constructed by using the estimated head loss coefficients and the empirical formula of head loss coefficients was derived to consider the variation of inflow discharge ratios at the surcharged square manhole. The empirical formula could be applied to the design and assessment of the urban drainage system.

An experimental study for estimation of head loss coefficients at surcharged four-way combining manholes (과부하 4방향 합류맨홀에서의 손실계수 산정을 위한 실험 연구)

  • Ryu, Taek Hee;Kim, Jung Soo;Yoon, Sei Eui
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.12
    • /
    • pp.1015-1025
    • /
    • 2016
  • In general, manholes installed as urban drainage facilities are a variety forms such as straight path manholes, 90 degree bend manhole, three-way combining manhole, and four-way combining manhole. In particular, the surcharged flow at a four-way manholes installed in the downstream of urban sewer system is the main cause of the urban inundation caused by the energy loss. Therefore, it is necessary to analyze the flow characteristics and estimate the head loss coefficients at surcharged four-way combining manholes. The hydraulic experimental apparatus which can change the manhole shapes (square, circle) and flow ratios were installed to estimate the head loss coefficients. In the experiments, two inflows ($Q_m$, $Q_{lat}$) were varied from 0 to $4.8{\ell}/sec$ and 24 combinations were tested in total. The flow ratios $Q_{lat}/Q_{out}$ were varied from 0 to 1 for a total flow $Q_{out}$ ($Q_{out}=Q_m+2Q_{lat}$) of 2, 3, 4, and $4.8{\ell}/sec$, respectively. The variation of head losses were strongly influenced by the lateral inflow because the head loss coefficient increases as the flow ratios $Q_{lat}/Q_{out}$ increases. It was estimated head loss coefficients of the circular manhole is slightly lower than those of the square manhole. However, there was no significant difference of head loss as discharges change. The range of head loss coefficients at four-way combining manhole according to the change of the lateral inflow ratio was estimated to be 0.4 to 0.8. Also, the relation equations between the head loss coefficients (K) and the lateral inflow ratios ($Q_{lat}/Q_{out}$) were suggested in this paper.

An Experimental Study for Reduction of Energy losses at Surcharged Four-way Combining Square Manhole (과부하 4방향 사각형 합류맨홀에서의 에너지 손실 저감을 위한 실험 연구)

  • Kim, Jung Soo;Kim, Chae Rin;Yoon, Sei Eui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.311-324
    • /
    • 2017
  • Energy loss at manholes under surcharged flow is considered as one of the major causes of inundation in urban area. Therefore, it is necessary to analyze the flow characteristics to reduce the energy loss in the surcharged four-way combining manhole. In this study, hydraulic experimental apparatus was constructed considering the results of the present survey. Square manholes and pipe diameters were reduced to 1/5 by applying sewer facility standards. Numerical simulations were carried out with the Fluent 6.3 model to derive the invert condition which can reduce the energy loss in the surcharged four-way combining square manhole. The hydraulic experiments were carried out according to the various conditions of the lateral flow rate($Q_{lat}/Q_{out}$), discharge of outflow pipe (2.0, 3.0, 4.0, 4.8 l/sec), and invert shape (rectangle and square open conduit type). The crossed invert was not found to improve the drainage capacity of the surcharged four-way rectangular combining manhole. However, the improved rectangle open conduit type invert and square open conduit type invert were analyzed to improve the drainage capacity by reducing the head loss coefficients by about 8% and 28%, respectively. Therefore, in order to increase the drainage capacity of urban facilities, it is possible to install and use the improved invert proposed in this study.

Estimation of Head Loss Coefficients with Change of Invert Type in Four-Way Combining Manholes (4방향 합류맨홀 내부의 인버트 설치에 따른 손실계수 산정)

  • Ryu, Taek Hee;Kim, Jung Soo;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.465-465
    • /
    • 2016
  • 관거시설은 관거, 맨홀(manhole), 우수토실, 물받이, 연결관, 침투시설, 저류시설, 펌프장 등을 포함하는 시설들로 구성되어 있다. 여기서 맨홀은 배수시설의 유지와 관리를 위하여 일정거리마다 설치되고 있으며, 관거의 기점, 방향, 경사 및 관경이 변하는 곳, 단차가 발생하는 곳, 관거가 합류하는 곳에는 반드시 설치한다(환경부, 2011). 그러나 하수도시설기준(환경부, 2011)에서 합류맨홀의 설치에 관한 사항은 T형 합류맨홀에 관한 개략적인 표만 제시되어 있을 뿐, 4방향 합류맨홀에 대한 구체적인 설치 기준이 제시되어 있지 않은 실정이다. 또한 에너지 손실의 저감 및 배수능력을 증대시키기 위하여 맨홀내 설치되는 인버트는 미국의 형태 및 기준을 그대로 적용하고 있으므로 관거시설의 시설의 합리적인 설계기준을 제시하기 위하여 인버트가 설치된 4방향 합류맨홀에서의 흐름특성 및 수두 손실을 분석할 필요가 있다. 본 연구에서는 인버트가 설치된 4방향 합류맨홀 손실계수 산정 및 흐름특성을 분석하기 위하여 문헌조사 및 현장조사를 실시하여 수리실험 장치를 제작하였다. 실험에 사용된 맨홀은 하수도시설기준(환경부, 2011)의 표준 1호 맨홀을 1/5로 축소하였고, 인버트는 설치되지 않은 조건(CASE A), 반원형 인버트(CASE B), U형 인버트(CASE C)를 각각 실험하였으며, 실험유량으로 총 유출량 (Qout)은 $2{\sim}5{\ell}/sec$, 총 유출량에 대한 측면 유입량($Q_{Lat}$)의 비($Q_{Lat}/Q_{out}$)는 0~1 조건으로 변화시키면서 흐름특성 및 손실계수를 산정하였다. 실험결과 측면유량비가 증가함에 따라 CASE B와 CASE C는 CASE A보다 맨홀 내 수심이 약 3~7%정도 증가되는 경향을 나타내고 있었으며, 측면유량비의 증가에 따른 손실계수 산정 결과, CASE B는 CASE A 보다 약 30%정도 손실계수가 증가하였으며, CASE C는 CASE A보다 약 35%정도 손실계수가 증가하는 것으로 나타났다. 이는 기존에 사용되고 있는 인버트의 형상이 4방향 합류맨홀에서의 손실 저감 및 배수능력을 증대시키기 보다는 오히려 맨홀 내 통수능력을 저하시켜 4방향 합류맨홀에서의 배수능력을 저감시키는 것으로 분석되었다. 그러므로 기 사용되는 인버트의 개선이 필요하며 관거시설의 배수능력을 증대하기 위하여 지속적인 연구를 통한 개선된 인버트의 형상 제시가 필요할 것으로 판단된다.

  • PDF

Analysis on the Change of Haed Loss Coefficients at Four-Way Square Combining Manhole (4방향 사각형 합류맨홀에서의 손실계수 변화분석)

  • Jo, Jun Beom;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.176-176
    • /
    • 2017
  • 배수시설 내 맨홀에서의 과부하 흐름은 관거시설의 배수 능력을 저하시켜 우수의 역류로 인한 도시 침수피해의 가중 요인이 된다. 특히, 도시 유역 중 하류부의 저지대에서 주로 설치되는 합류 맨홀은 저지대 침수에 많은 영향을 미치므로 합류맨홀에서의 흐름특성 분석 및 유입유량 변화에 따른 손실계수의 변화에 관한 연구가 필요한 실정이다. 현재까지 중간맨홀, $90^{\circ}$ 접합맨홀 및 3방향(T형) 합류맨홀 등에 관한 연구는 지속적으로 수행되고 있으나 4방향 합류맨홀에 관한 연구는 기초적인 연구만 수행되고 있다. 4방향 합류맨홀은 세 개의 유입관과 한 개의 유출관으로 구성되어 있으므로 각 유입관의 유입유량 변화에 따라서 맨홀에서의 손실계수가 다양하게 변화된다. 이와 같은 유입유량 변화에 따른 맨홀 내 흐름특성 분석 및 손실계수 산정에 관한 연구는 국내에서는 전무한 실정이다. 그러므로 유입유량 변화에 따른 4방향 합류맨홀에서의 손실계수 변화특성의 분석이 필요하다. 본 연구에서는 4방향 사각형 합류맨홀에서 세방향에서 유입되는 각 유입유량의 유입비($Q_{in}/Q_{out}$)가 0.0~1.0으로 변화하는 조건에서 평균 손실계수를 산정하기 위하여 하수도시설기준(환경부, 2011)의 표준 1호 맨홀 및 연결관경을 1/5로 축소하여 수리실험 장치를 제작하였다. 유출유량은 $3{\ell}/sec$이고 각 유입관(주유입관 및 좌 우측면유입관)의 유입유량을 $0{\sim}3{\ell}/sec$까지 유입유량의 비율을 각각 10%씩 변화시키면서 수리실험을 실시하였다. 실험결과 주관거의 유입유량이 줄어들고 측면관거의 유입유량이 늘어나면서 손실계수가 상승하는 것으로 나타났으며, 한쪽 측면 관거에서만 유입유량이 들어오는 $90^{\circ}$ 접합맨홀의 형태에서 손실계수가 가장 크게 나타났으며, 유입유량 변화에 따른 4방향 합류맨홀에서의 손실계수의 범위는 0.5~1.7으로 산정되었다. 이는 과부하 4방향 사각형 합류맨홀에서는 측면 유입관에서의 유입유량의 증가에 따라 평균 손실계수 값이 크게 증가되는 것으로 판단된다. 이는 김정수(2010) 등이 산정한 $90^{\circ}$ 접합맨홀의 손실계수 및 중간맨홀의 손실계수와 유사하게 나타났으므로 전체적인 손실계수의 범위는 타당하다고 판단된다. 또한, Wang(1988) 등의 유사연구와의 유입유량 변화에 따른 손실계수의 변화 경향도 유사하였다. 따라서 본 연구에서 산정된 유입유량 변화 조건이 고려된 4방향 합류맨홀에서의 손실계수는 XP-SWMM 등의 부정류 흐름이 고려된 도시지역의 침수해석이나 관거 배수능력 평가에 활용이 가능할 것으로 판단된다.