• Title/Summary/Keyword: Four-component

Search Result 1,360, Processing Time 0.035 seconds

Effects of a mouthwash containing potassium nitrate, sodium fluoride, and cetylpyridinium chloride on dentin hypersensitivity: a randomized, double-blind, placebo-controlled study

  • Hong, Ji-Youn;Lim, Hyun-Chang;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • 제46권1호
    • /
    • pp.46-56
    • /
    • 2016
  • Purpose: We evaluated the efficacy of a mouthwash containing potassium nitrate ($KNO_3$) as its main component, along with sodium fluoride (NaF) and cetylpyridinium chloride (CPC). The primary endpoint was the relief of dentin hypersensitivity (DH) against the cold stimuli. The effects on other DH tests and periodontal inflammation were also evaluated. Methods: We used a single-center, double-blind, placebo-controlled, randomized design. A total of 82 patients with DH (40 in the test group, 42 placebo controls) were analyzed using visual analog scales (VASs) for a cold test, a tactile test, a compressive air test, and self-reported pain during daily activities, as well as clinical parameters including plaque index, gingival index, modified sulcular bleeding index (mSBI), gingival recession, and probing depth, which were collected at baseline and after four and six weeks of mouthwash use. Results: VAS scores for cold sensations, tactile sensations, the compressive air test, and self-reported pain significantly decreased from baseline during the six weeks in both groups (P<0.01), and no significant differences between the groups were found. In male patients (10 in the test group and 7 in the control group), both groups showed significant reductions in VAS scores for the cold test over the six weeks, and greater reductions were found in the test group than in the control group between four and six weeks (P=0.01) and between baseline and six weeks (P<0.01). In addition, the mSBI in the test group significantly decreased from baseline during the six weeks (P<0.01), and the changes at four and six weeks from baseline were significantly greater in the test group compared to the control group (P=0.03 and P=0.02, respectively). Conclusions: A mouthwash containing a mixture of $KNO_3$, NaF, and CPC reduced DH and gingival inflammation, however, the efficacy was comparable to the control group.

하수처리시설의 자연 재해 영향 정량화 지수 개발 연구 (Development of a disaster index for quantifying damages to wastewater treatment systems by natural disasters)

  • 박정수;박재형;최준석;허태영
    • 상하수도학회지
    • /
    • 제35권1호
    • /
    • pp.53-61
    • /
    • 2021
  • The quantified analysis of damages to wastewater treatment plants by natural disasters is essential to maintain the stability of wastewater treatment systems. However, studies on the quantified analysis of natural disaster effects on wastewater treatment systems are very rare. In this study, a total disaster index (DI) was developed to quantify the various damages to wastewater treatment systems from natural disasters using two statistical methods (i.e., AHP: analytic hierarchy process and PCA: principal component analysis). Typhoons, heavy rain, and earthquakes are considered as three major natural disasters for the development of the DI. A total of 15 input variables from public open-source data (e.g., statistical yearbook of wastewater treatment system, meteorological data and financial status in local governments) were used for the development of a DI for 199 wastewater treatment plants in Korea. The total DI was calculated from the weighted sum of the disaster indices of the three natural disasters (i.e., TI for typhoon, RI for heavy rain, and EI for earthquake). The three disaster indices of each natural disaster were determined from four components, such as possibility of occurrence and expected damages. The relative weights of the four components to calculate the disaster indices (TI, RI and EI) for each of the three natural disasters were also determined from AHP. PCA was used to determine the relative weights of the input variables to calculate the four components. The relative weights of TI, RI and EI to calculate total DI were determined as 0.547, 0.306, and 0.147 respectively.

수입자동차 리콜 수요패턴 분석과 ARIMA 수요 예측모형의 적용 (Analysis of the Recall Demand Pattern of Imported Cars and Application of ARIMA Demand Forecasting Model)

  • 정상천;박소현;김승철
    • 산업경영시스템학회지
    • /
    • 제43권4호
    • /
    • pp.93-106
    • /
    • 2020
  • This research explores how imported automobile companies can develop their strategies to improve the outcome of their recalls. For this, the researchers analyzed patterns of recall demand, classified recall types based on the demand patterns and examined response strategies, considering plans on how to procure parts and induce customers to visit workshops, recall execution capacity and costs. As a result, recalls are classified into four types: U-type, reverse U-type, L- type and reverse L-type. Also, as determinants of the types, the following factors are further categorized into four types and 12 sub-types of recalls: the height of maximum demand, which indicates the volatility of recall demand; the number of peaks, which are the patterns of demand variations; and the tail length of the demand curve, which indicates the speed of recalls. The classification resulted in the following: L-type, or customer-driven recall, is the most common type of recalls, taking up 25 out of the total 36 cases, followed by five U-type, four reverse L-type, and two reverse U-type cases. Prior studies show that the types of recalls are determined by factors influencing recall execution rates: severity, the number of cars to be recalled, recall execution rate, government policies, time since model launch, and recall costs, etc. As a component demand forecast model for automobile recalls, this study estimated the ARIMA model. ARIMA models were shown in three models: ARIMA (1,0,0), ARIMA (0,0,1) and ARIMA (0,0,0). These all three ARIMA models appear to be significant for all recall patterns, indicating that the ARIMA model is very valid as a predictive model for car recall patterns. Based on the classification of recall types, we drew some strategic implications for recall response according to types of recalls. The conclusion section of this research suggests the implications for several aspects: how to improve the recall outcome (execution rate), customer satisfaction, brand image, recall costs, and response to the regulatory authority.

HPLC-PDA를 이용한 반하, 호장남성, 수반하의 분류 및 함량분석 (Content Comparative Analysis and Classification for Piniellia ternate, P. pedatisecta and Typhonium flagelliforme by HPLC-PDA analysis)

  • 조지은;이아영;김효선;문병철;최고야;지윤의;김호경
    • 대한본초학회지
    • /
    • 제28권5호
    • /
    • pp.95-101
    • /
    • 2013
  • Objectives : A quantitative method using high performance liquid chromatography with a photodiode array detector(HPLC-PDA) was established for the quantitative analysis of the four main compound and pattern analysis to classification Piiellia ternate, P. pedatisecta and Typhonium flagelliforme. Methods : The analytical procedure for the determination of P. ternata, together with the known main compounds uracil, uridine, guanosine and adenosine was established. Optimum HPLC-PDA separation of these P. ternata was possible on Luna C18(2) column material, using water and acetonitrile as mobile phase. The method was validated according to regulatory guidelines. In addition, this assay method were analyzed for the content of four main compound in P. ternata, P. pedatisecta and T. flagelliforme and by data obtained from the HPLC-PDA analysis was performed principal component analysis(PCA). Results : Validation results indicated that the HPLC method is well suited for the determination of the roots of P. ternata with a good linearity ($r^2$ > 0.999), precision and recovery rates. Analysis of HPLC-PDA, the average content of uracil, uridine, guanosine and adenosine was significantly higher in P. ternate>P. pedatisecta> T. flagelliforme order. The application of PCA to main compound data by HPLC-PDA permitted the effective discrimination among the three species. Conclusions : Analysis of both HPLC-PDA and PCA confirmed the fact that four main compound and pattern profiles of P. ternata, P. pedatisecta and T. flagelliforme were different from each other.

클럽의 길이 변화에 따른 골프 스윙의 지면반력 변화 (Changes of Ground Reaction Forces by the Change of Club Length in Golf Swing)

  • 성낙준
    • 한국운동역학회지
    • /
    • 제17권2호
    • /
    • pp.31-40
    • /
    • 2007
  • Proper weight shifting is essential for a successful shot in golf swing and this could be described by means of the ground forces between the feet and ground. It is assumed that the ground forces would different according to the club used because the length and swing weight of each club is different. But, in present, it is not clear what changes are made by the change of clubs and this affect the swing motion. Therefore this study focused on the investigation of the changes of the ground forces and ground reaction forces (GRF) by the change of club length. The subjects were three professional male golfers. Four swings (driver, iron 3, iron 5, and iron 7) for each subject were taken by two high speed video cameras and two AMTI force platforms were used to measure the GRF simultaneously. Kwon GRF 2.0 and Mathcad 13 software were used to post processing the data. Changes of the three major component of GRF (Vertical, lateral, anterior-posterior force) at 10 predefined events were analyzed including the maximum. Major findings of this study were as follows. 1. Vertical forces; - There were no significant changes until the top of backswing. - Maximum was occurred at the club horizontal position in the downswing for both feet. The shorter club produced more maximum forces than longer ones in the left foot, but reverse were true for the right foot. - Maximum forces at impact shows the same patterns. 2. Lateral forces; Maximum was occurred at the club horizontal position for both feet, but there were no lateral forces because the direction of two forces was different. Maximum force pattern by different clubs was same as the vertical component. 3. Anterior-posterior forces; - This component made a counter-clock wise moment about a vertical axis located between two foot until the club vertical position was reached during the backswing, and reverse moment were produced when the club reached horizontal at the downswing. - Also this component made a forward moment about a horizontal axis located in the CG during the fore half of the downswing, and a reverse moment until the club reached vertical at the follow through phase. Maximum was occurred at the club vertical in the downswing for both feet. The longer club produced more maximum forces than shorter ones for both feet.

쌀의 KOH 농도별 붕괴양상에 따른 품종변이 해석 (Analysis of Varietal Variation in Alkali Digestion of Milled Rice at Several Levels of Alkali Concentration)

  • 최해춘;손영희
    • 한국작물학회지
    • /
    • 제38권1호
    • /
    • pp.31-37
    • /
    • 1993
  • 우리나라 주요 벼 재배품종 및 신육성계통(자포니카: 25품종, 통일형:8품종)에 대한 쌀 알칼리 붕괴성의 품종적 특이성을 분시검토하여 보고자 KOH 농도를 0.8-1.8까지 0.2% 간격으로 처리하여 농도별 쌀의 알칼리 붕괴반응을 조사하고 주성분분석법을 적용하여 품종적 유형을 분류하였다. 주성분분석에서 상위 2개 주성분치의 변이가 전변이량의 92%을 차지하였고 제1 및 제2 주요분치 좌표상의 품종분포에 따라 크게 4개 유형으로 군집화 시킬 수 있었다. 제 I 군에서는 전 KOH 농도에 걸쳐 거의 비슷하게 알칼리 붕괴성(ADV)가 낮은 도봉벼만 유일하게 분포하였고, 제 II군에는 1.4% KOH 농도에서 중간정도의 ADV 이면서 고-저 알칼리 농도 ADV간차가 중도인 백운찰벼, 신선찰벼 및 수원 34002 등 찰벼가 포함되어 있었다. 제 III군에는 1.4% KOH 농도에서 중-중고의 ADV 이면서 저-고 KOH 농도간 ADV 변화가 심했던 대부분의 통일형 품종과 자포니카 조생계가 분포되어 있었고 육도농림찰 001와 한강 찰벼등은 이 유형에 포함되어 있었다. 제 IV군에는 1.4% KOH 농도에서 ADV가 중고이상으로 높으면서 고-저 알칼리 농도 ADV간차가 중-중고인 중생 및 중만생 자포니카 품종들이 주로 분포 하였으며 조생인 금조벼가 이 유형에 속하였다. 여기서 제 1 주성분은 전 알칼리 농도에서 평균적으로 표현되는 붕괴성 정도였고 제 2 주성분은 저-고 KOH 농도의 ADV간 차 또는 KOH 농도에 따른 ADV 변화의 회귀계수와 밀접하게 관련된 요소였다. 1.2%-1.4% KOH 농도에서의 ADV는 저-고 KOH 농도간 ADV차와 2차 곡선 회귀계수를 나타내었다.

  • PDF

농촌마을 주택대문의 경관구성요소 설정 및 실태파악 - 충남 청양군을 중심으로 - (A Establishment of Visual Component Elements and Investigation Analysis for a House-Gates in Rural Villages)

  • 이경진;조성호;송병화
    • 농촌계획
    • /
    • 제13권3호
    • /
    • pp.83-90
    • /
    • 2007
  • The purpose of main entrance was to protect the house with the wall and working for the house-gate where people come in and go out. On the other hand, the type of main entrance is changed variously depended on the materials for house and method of construction. Eleven villages in the Chungyang-Gun where the environment of rural villages is well maintained was chosen and researched to make data. These data of visual landscape elements were analysed by using the SPSS 12.0 for Windows. Relations of the visual component elements were analysed by the analysis for frequency and analysis for crosstab. From the above research we could conclude below results. Through review of the pre-researching and researching literatures, 11 types of visual component elements were selected such as the types of the gate, the looking through degree of the gate, the material of the gate, the color of the gate, the plan of the house, the material of the roof, a material of the wall, a color of the wall, the form of the penetration, the area to put, the area of a site, the year of the constructing a building. For the types of the gate, the gate from without the roof has been the most popular since it appeared 41.5%. For the looking through degree of the gate, a complete blockade form has been the most popular since it appeared 63.2%. For the material of the gate, the iron plate has been the most popular since it appeared 32.1%. For the color of the gate, color has been the most popular since it appeared 68.4%. For the plan of the house, 'ㄷ' form has beneath most popular since it appeared 38.3%. For the material of the roof. The Zinc has been the most popular since it appeared 51.9%. For a material of the wall, A cement mortar has been the most popular since it appeared 47.7%. For a color of the wall, Without tile color has hem the most popular since it appeared 67.0%. For the form of the penetration. The plain form has been the most popular since it appeared 54.0%. For tile area of a site, $100m^2{\sim}200m^2$ has been the most popular since it appeared 39.0%. The results of this study can provide to use of indicates four rural-housing reform. From now on, the results look forward to offering the meaning directions for the improvement of rural house gates.

파이로테크닉 장치의 고폭 폭발성능 정밀 하이드로다이나믹 해석 (A Full Scale Hydrodynamic Simulation of High Explosion Performance for Pyrotechnic Device)

  • 김보훈;여재익
    • 한국시뮬레이션학회논문지
    • /
    • 제28권2호
    • /
    • pp.1-14
    • /
    • 2019
  • 고에너지 구성 요소 시스템의 설계를 위하여 고폭화약의 폭발 반응을 엄밀하게 모사할 수 있는 실제 규모의 하이드로다이나믹 해석을 수행하였다. 폭발성능 정밀 해석 SW는 고에너지 물질의 충격 민감도를 정량화하기 위한 반응 유동 모델을 검증하고 일련의 화약 트레인을 통과하는 충격파 전달을 예측하기 위해 개발되었다. 파이로테크닉 장치는 여폭약(HNS+HMX), 격벽(STS), 수폭약(RDX), 파이로테크닉 추진제(BPN)로 구성된다. 추진제 연소로 인하여 생성된 고압의 연소 가스는 충격파와 저밀도파 간 간섭에 의해 유도된 고유의 진동 유동 특성을 파악하기 위하여 10 cc 밀폐형 챔버에 유입된다. 특정 주파수(${\omega}_c=8.3kHz$)에서의 피크 특성을 검증하기 위하여 실험 및 계산으로 측정된 압력 진동을 비교하였다. 본 연구에서는 고폭화약의 폭발반응과 추진제의 폭연반응, 비-반응 금속의 변형에 관하여 단계별 수치해석 기법들을 충격 물리 해석 SW로 구현함으로써 고에너지 물질 시스템에 대한 대규모 하이드로다이나믹 시뮬레이션을 용이하게 하였다. 개발된 고폭화약 폭발성능 정밀 해석 SW를 고에너지 구성 요소 시스템의 파이로테크닉 연소 반응 M&S에 적용하여 실험 결과와 비교함으로써 검증하였다.

The Study of Single Phase Source Stability consider for The DSC Cell's Operation Character by Controlled Feed-back Circuit

  • Lee, Hee-Chang
    • Journal of information and communication convergence engineering
    • /
    • 제4권4호
    • /
    • pp.170-173
    • /
    • 2006
  • Recently, with increasing efficiency of DSC (photo-electrochemical using a nano-particle), The Performance of DSC solar generation system also needs improvement. The approach consists of a Fly-back DC-DC (transfer ratio 1:10) converter to boost the DSC cell voltage to 300VDC. The four switch (MOSFET) inverter is employed to produce 220V, 60Hz AC outputs. High performance, easy manufacturability, lower component count., safety and cost are addressed. Protection and diagnostic features form an important part of the design. Another highlight of the proposed design is the control strategy, which allows the inverter to adapt to the: requirements of the load as well as the power source. A unique aspect of the design is the use of the DSP TMS320LF2406 to control the inverter by current and voltage feed-back. Efficient and smooth control of the: power drawn from the DSC Cell is achieved by controlling the front end DC-DC converter in current mode.

시뮬레이션을 이용한 EPCIS의 효율화 방안에 관한 연구 (A Study on the Efficiency of the EPCIS using Simulation)

  • 이종석;이창호
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 추계학술대회
    • /
    • pp.349-355
    • /
    • 2010
  • EPCIS(EPC Information Services) system is a core component of EPCglobal Architecture Framework offering information of the freights, the time of awareness and the location of awareness on the EPCglobal Network. The role of EPCIS is to exchange information based on EPC. There are four kinds of event data which are object event data, aggregation event data, quantity event data, and transaction event data. These EPCIS events data are stored and managed in EPCIS repository. This paper leads to separate a in-out data overload of integrated EPCIS event and suggests the method to effectively manage EPCIS repository for exchanging data smoothly. In order to verify a effectiveness, we measure the performance of the system using a simple testing simulation by comparing existing method and suggested method.

  • PDF