• Title/Summary/Keyword: Four-Quadrant Operation

Search Result 39, Processing Time 0.039 seconds

Comparative Analysis of Sequence Control in Six Series-Connected ITER VS Converters (6 직렬 연결된 ITER VS 컨버터의 시퀀스제어 비교 해석)

  • Jo, Hyunsik;Jeong, Jinyong;Jo, Jongmin;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.399-406
    • /
    • 2014
  • This study investigates the structure and operation of the ITER VS converter and proposes a sequence control method for six series-connected VS converters to reduce reactive power. The operation and the proposed sequence control method are verified through RTDS simulation. The ITER VS converter must supply voltage/current to the superconducting magnets for plasma current vertical stabilization, and the four-quadrant operation must proceed without a zero-current discontinuous section. The operation mode of the VS converter is separated into a 12- and 6-pulse circulating current and transition modes according to the size of the load current. The output voltage of the unit VS converter is limited because of the rated voltage; however, the superconducting coil must increase the operating output voltage. Thus, the VS converter must be connected in a 6-series to provide the required operating output voltage. The output voltage of the VS converters is controlled continuously; however, reactive power is limited within a minimized value of the grid. In this study, the unit converter is compared with converters connected in a 6-series to determine a suitable sequence control method. The output voltage is the same in all cases, but the maximum reactive power is reduced from 100% to 73%. This sequence control method is verified through RTDS simulation.

The Modified Surgical Treatment of Gynecomastia: Pan-cake Method (여성형 유방증(Gynecomastia)의 개선된 수술적 치료방법: 팬 케이크 법(Pan-cake Method))

  • Park, Jin Hong;Lee, Yoon Ho
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.628-634
    • /
    • 2007
  • Purpose: Subcutaneous mastectomy has been accepted as a standard for the treatment of gynecomastia. Surgical managements including ultrasound-assisted liposuction(UAL) have had limited success and several combined approaches were tried to find the most effective method. We designed a modified subcutaneous mastectomy, which we call "pan-cake method". The purpose of this study is to evaluate the results of our method for the treatment of gynecomastia. Methods: 16 patients from 16 to 31 years of age having gynecomastia were operated using the pan-cake method. 11 patients were in grade I, and 5 patients were in grade II, no patient were in grade III or IV, according to Rod's classification. The pan-cake method started with modified periareolar incision. We executed subcutaneous dissection first and suprafascial dissection next. After dividing the breast into four equal quadrants, we removed breast tissue from each quadrant as necessary. The operation time for the resection was recorded and the weight of removed parenchyme tissues was measured. Results: All the operations were successful. There were no asymmetries, contour deformities, or irregularities. Only 6 cases needed the combined therapy with ultrasound-assisted liposuction(UAL) because of the step deformities. The average operation time was 24.1 minutes and the average weight of removed breast tissue was 98.1g. All the patients were satisfied with the aesthetic results. Conclusion: We concluded that the pan-cake method is an alternative option for the surgical treatment of gynecomastia, giving good aesthetic results and relatively short operation time.

PWM-based Integral Sliding-mode Controller for Unity Input Power Factor Operation of Indirect Matrix Converter

  • Rmili, Lazhar;Hamouda, Mahmoud;Rahmani, Salem;Blanchette, Handy Fortin;Al-Haddad, Kamal
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1048-1057
    • /
    • 2017
  • An indirect matrix converter (IMC) is a modern power generation system that enables a direct ac/ac conversion without the need for any bulky and limited lifetime electrolytic capacitor. This system also allows four-quadrant operation, generation of sinusoidal output voltage waveforms with variable frequency and amplitude, and control of input power factor. This study proposes a pulse-width modulation-based sliding-mode controller to achieve unity input-power factor operation of the IMC independently of the active power exchanged with the grid, as well as a fast dynamic response. The designed equivalent control law determines, at each sampling period, the appropriate q-axis component of the modulated input current to be injected into the grid through the LC input filter. An integral term of the error is included in the expression of the sliding surface to increase the accuracy of the control method. A double space vector modulation method is used to synthesize the direction of the space vector of the input currents as required by the sliding-mode controller and the space vectors of the target output voltages. Simulation and experimental results are provided to show the effectiveness and evaluate the performance of the proposed control method.

Configurations of High Power VSI Drives for Traction Applications Using Multi Level Inverters and Multi Phase Induction Motors (멀티레벨 인버터와 다상 유도기를 이용한 견인기용 대전력 VSI의 구조와 특성)

  • Gopakumnr, K.;Ryu, Hong-Je;Kim, Jong-Su;Im, Geun-Hui
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.500-504
    • /
    • 1997
  • Current source inverter drives of auto sequentially commutated type are very popular in high power applications, because of simple power circuit configuration with four quadrant operation. But the six-step current output create harmonic problems and the input power factor of such a drive is not always good. In this respect pulse width modulated drives using gate turn off thyristors ( GTO ) are finding application, especially in traction drives. However the switching and snubber loses of a GTO do not permit the inverter switching frequency go beyond a few hundred hertz.This will again introduce low frequency harmonic problems. Multi level inverters of the 3-level and 5-level can be considered as an alternative to overcome the low switching frequency harmonic problem of the 2-level GTO inverters. But with multi level inverters the complexity of the power circuit increases. In this paper a combination of multi level ( 2-level and 3-level ) inverters and multi phase induction motor ( 3-phase and 6-phase) configurations are presented for high power VSI drives for traction applications with reduced inverter switching frequency requirements coupled with reduced voltage rating for the power switch.

  • PDF

Implementation of Control for Four quadrant Operation of ITER CCU/L Converter (ITER CCU/L 컨버터의 4 상한 운전을 위한 제어의 구현)

  • Park, Hyeon-Cheol;Kim, Chang-Woo;Lee, Chang-hee;Park, Hyung-Jin;Jo, Seong-Man;Oh, Jong-Seok;Suh, Jae-Hak;Choi, Jungwan
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.225-226
    • /
    • 2015
  • 이 논문에서는 ITER 초전도 코일 전원 장치 중 진공 용기내에 형성된 자장의 오차를 보정해주는 CCU/L 컨버터의 4 상한 운전을 위한 제어 알고리즘을 설명하고, 제어 알고리즘을 실제 컨버터에 적용하여 구현하였다. ITER CCU/L 컨버터는 4 상한 제어를 통해 영 전류 불연속 구간 없이 Correction Coil에 전압(${\pm}85V$), 전류(${\pm}10kA$)를 공급해야 하고, 이를 위해선 4 상한 운전을 위한 제어가 매우 중요하다. 4 상한 운전은 다섯 가지 모드에서 동작된다. 본 논문에서, 각 모드에 대해 설명하고, 컨버터가 각 모드에서 정상적으로 제어되는지 시뮬레이션 및 실제 시험을 통해 검증하였다.

  • PDF

The Development of Battery Energy Storage System (전지를 이용한 에너지저장시스템 개발)

  • Ko, Yo;Eom, Young-Chang;Kim, Yun-Ho
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.104-113
    • /
    • 1993
  • Due to steady increase of electric power demand and decrease of load factor, the economic and reasonable operation of electric power system is necessary. Because of this reason, dispersed battery energy storage system(BESS) with fast response is receiving attractive attention. With these considerations, 20 kVA BESS is designed and tested to investigate the possibility of BESS application to power system. This paper describes the design specifications of simulator and test results. BESS is composed of batteries, conversion equipments, interconnecting equipments to power system, and control parts of the system. The inverter of BESS can carry out two functions as charger and discharger. Also, it can operate as a VAR compensator by four quadrant operation. Since this system is designed as a simulator of MW system, the conceptual design of MW system is possible by using the test result of test system The study of BESS is preliminary stage for the future MW class BESS.

  • PDF

Robotic lower pelvic port placement for optimal upper paraaortic lymph node dissection

  • Paek, Jiheum;Kang, Elizabeth;Lim, Peter C.
    • Journal of Gynecologic Oncology
    • /
    • v.29 no.6
    • /
    • pp.87.1-87.4
    • /
    • 2018
  • Objective: Upper paraaortic lymph node dissection (UPALD) to the infrarenal level is one of the most challenging robotic procedures. Because robotic system has the limitation in robotic arm mobility. This surgical video introduces a novel robotic approach, lower pelvic port placement (LP3), to perform optimally and simultaneously both UPALD and pelvic procedures in gynecologic cancer patients using da Vinci Xi system. Methods: The patient presented with high-grade endometrial cancer. She underwent robotic surgical staging operation. For the setup of the LP3, a line was drown between both anterior superior iliac spines. At 3 cm below this line, another line was drown and four robotic ports were placed on this line. Results: After paraaortic lymph node dissection (PALD) was completed, the boom of robotic system was rotated $180^{\circ}$ to retarget for the pelvic lateral displacement. Robotic ports were placed and docked again. The operation was completed robotically without any complication. Conclusion: The LP3 was feasible for performing simultaneously optimal PALD as well as procedures in pelvic cavity in gynecologic cancer patients. The advantage of LP3 technique is the robotic port placement that affords for multi-quadrant surgery, abdominal and pelvic dissection. The LP3 is facilitated by utilizing advanced technology of Xi system, including the patient clearance function, the rotating boom, and 'port hopping' that allows using every ports for a camera. The LP3 will enable surgeons to extend the surgical indication of robotic surgical system in the gynecologic oncologic field.

Surgical Treatment for Common Iliac Arteriovenous Fistula after Lumbar Laminectomy (요추궁절제술 후에 발생한 총장골동맥의 동정맥루에 대한 수술)

  • Ryu, Kyoung-Min;Ryu, Jae-Wook;Park, Seong-Sik;Kim, Seok-Kon;Seo, Pil-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.455-458
    • /
    • 2007
  • A 40 year-old male patient admitted for dyspnea and edema of the lower extremities. A pulsatile abdominal mass with a bruit was palpable in the right lower quadrant. Four months previously, he had underwent left partial lam-inectomy ($L4{\sim}5$) and discectomy at the L4 level due to disc protrusion, Computed tomography showed an ilio-iliac AV fistula with pseudoaneurysm at the L5 level. Because massive bleeding occurred when the aneurysm was entered, we closed the aneurysm and performed resection and suture of the aorta and both iliac arteries very near the aneurysm. After exclusion of the arterial side, we performed reduction angioplasty at the aneurysm and aorto-biiliac reconstruction with an artifcial graft. Twenty-four months after operation, he is doing well and hasn't had any complications on the follow-up.

Breast Conserving Operation and Radiation Therapy in Early Breast Cancer : Interim Analysis (초기유방암에서 유방보존수술 후 방사선치료 : 중간분석)

  • Kim, Jin-Hee;Kim, Ok-Bae;Kim, You-Sah
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2001
  • Purpose : To evaluate interim results in terms of failure, cosmetic results and survival after breast conserving operation and radiation therapy in early breast cancer. Material and Methods : From January 1992 through December 1997, seventy two patients with early stage 0, I and II breast cancer were treated with conservative surgery plus radiotherapy at Keimyung University Dongsan Medical Center. Age distribution was 25 to 77 years old with median age of 43. According to TNM stage, five patients had stage 0, thirty three were stage I, twenty five were IIa, and nine were IIb. Most patients underwent excision of all gross tumor and ipsilateral axillary dissection. Breast was irradiated through medial and lateral tangential fields of 6 MV photons to 50.4 Gy in 28 fractions over 5.5 weeks. We delivered a boost irradiation dose of 10 to 16 Gy in 1 to 2 weeks to excision site. Adjuvant chemotherapy was administered in forty one patients with CMF (cyclophosphamide, methotrexate, 5-fluorouracil) regimens of 6 cycles concurrently or before radiation. Cosmetic results were assessed by questionnaire to patients grading of excellent, good, fair, poor. Follow-up periods were 22 to 91 months with median 40 months. Results : Five year disease free survival rate (5YDFS) was $95.8\%$. According to stage, 5YDFS was $100\%,\;96.9\%,\;96\%\;and\;88.9\%$ in stage 0, I, IIa and IIb, respectively. Two patients had distant metastasis and one had local and distant failure. One patient with distant failure had bone and liver metastasis at 14 months after treatment and the other had lung and both supraclavicular metastasis at 21 months after treatment. Patient with local and distant failure had local recurrence on other quadrant in same breast and then salvaged with total mastectomy and chemotherapy but she died due to brain metastasis at 55 months. Complications were radiation pneumonitis in five patients (four patients of asymptomatic, one patients of symptomatic) and hand or arm edema(4 patients). Fifty nine patients answered our cosmetic result questionnaire and cosmetic results were good to excellent in fifty one patients $(86\%)$. Conclusion : We considered that conservative surgery and radiation for the treatment of early stage invasive breast cancer was safe and had excellent survival and cosmetic results. We need to assess about prognostic factors with longer follow up and with large number of patients.

  • PDF