• 제목/요약/키워드: Foundation structure

검색결과 1,440건 처리시간 0.029초

Main Engine의 Heavy Spare Parts가 설치된 Engine Room Opening Deck의 방진 설계 사례 (A Vibration Isolation Design for Engine Room Opening Deck around Heavy Spare Parts of the Main Engine)

  • 전용훈;임구섭;정태석
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2009년도 특별논문집
    • /
    • pp.93-96
    • /
    • 2009
  • Foundation structure for the main engine heavy spare parts in the engine room is susceptible to resonance problem due to outfitting weight. In addition the deck floor has a large opening for the main engine installation and maintenance, which further weakens the foundation structure. To reinforce the weak structure, two types of approaches have been used; 1) insert an H-pillar below or above the floor and 2) increase the stiffener size. In this paper, the H-pillar approach is used to solve the vibration problem of the foundation structure in the engine room opening area. A commercial program is used to analyze the vibration problem ad to find the location and the size of the H-pillar. Modal test at the quay and on-board vibration measurement during the sea trial have confirmed the validity of inserting an H-pillar below the floor.

  • PDF

국내 보강토옹벽 신기술 조사 연구 (Investigation on Recently Developed Reinforced Soil Wall System)

  • 이광우;조삼덕
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.158-167
    • /
    • 2008
  • Reinforced earth wall system has been popularized since its introduction to Korean civil engineering society in early 1980's. Nowadays, the increased use of reinforced earth wall for the purpose of obtaining more land brings several additional demands such as environmental-friendly, better stable and constructible, and economical system. This paper introduces some recently developed reinforced earth wall systems with consideration of the current demands.

  • PDF

Performance-based framework for soil-structure systems using simplified rocking foundation models

  • Smith-Pardo, J. Paul
    • Structural Engineering and Mechanics
    • /
    • 제40권6호
    • /
    • pp.763-782
    • /
    • 2011
  • Results from nonlinear time-history analyses of wall-frame structural models indicate that the condition of vulnerable foundations -for which uplifting and reaching the bearing capacity of the supporting soil can occur before yielding at the base of the shear walls- may not be necessarily detrimental to the drift response of buildings under strong ground motions. Analyses also show that a soil-foundation system can inherently have deformation capacity well in excess of the demand and thus act as a source of energy dissipation that protects the structural integrity of the shear walls.

Influence of structure-soil-structure interaction on foundation behavior for two adjacent structures: Geo-centrifuge experiment

  • Ngo, Van-Linh;Kim, Jae-Min;Lee, Changho
    • Geomechanics and Engineering
    • /
    • 제19권5호
    • /
    • pp.407-420
    • /
    • 2019
  • This paper illustrates the results of a series of seismic geotechnical centrifuge experiments to explore dynamic structure-soil-structure interaction (SSSI) of two structures (named S1 and S2) installed on ground surface. A dense homogeneous ground is prepared in an equivalent shear beam (ESB) container. Two structural models are designed to elicit soil-foundation-structure interaction (SFSI) with different masses, heights, and dynamic characteristics. Five experimental tests are carried out for: (1) two reference responses of the two structures and (2) the response of two structures closely located at three ranges of distance. It is found that differential settlements of both structures increase and the smaller structure (S2) inversely rotates out of the other (S1) when they interact with each other. S2 structure experiences less settlement and uplift when at a close distance to the S1 structure. Furthermore, the S1 structure, which is larger one, shows a larger rocking and a smaller sliding response due to the SSSI effects, while S2 structure tends to slide more than that in the reference test, which is illustrated by an increase in sliding response and rocking stiffness as well as a decrease in moment-to-shear ratio (M/H·L) of the S2 structure.

다지지점 지진입력에 대한 현수교의 지반-구조물 상호작용해석 (Soil-Structure Interaction Analysis of Suspension Bridge for Multiple-Support Seismic Input)

  • 김재민;이명규;신용우
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.182-189
    • /
    • 2003
  • Member actions of long-span suspension bridge due to multiple-support motion are generally larger than those for synchronous support motion frequently employed in aseismic design of a conventional structure. In this study, all the sources of the asynchronous support motion are considered including the loss of coherence and the soil-structure interaction as well as the time delay due to wave propagation of seismic waves. The substructure technique analyzing total soil-foundation-structure system as a superposition of two sub-structures including soil-foundation system and structure itself is employed for the seismic response analysis of the suspension bridge. Finally, an application example is presented to demonstrate applicability of the proposed methodology.

  • PDF

Seismic analysis of turbo machinery foundation: Shaking table test and computational modeling

  • Tripathy, Sungyani;Desai, Atul K
    • Earthquakes and Structures
    • /
    • 제12권6호
    • /
    • pp.629-641
    • /
    • 2017
  • Foundation plays a significant role in safe and efficient turbo machinery operation. Turbo machineries generate harmonic load on the foundation due to their high speed rotating motion which causes vibration in the machinery, foundation and soil beneath the foundation. The problems caused by vibration get multiplied if the soil is poor. An improperly designed machine foundation increases the vibration and reduces machinery health leading to frequent maintenance. Hence it is very important to study the soil structure interaction and effect of machine vibration on the foundation during turbo machinery operation in the design stage itself. The present work studies the effect of harmonic load due to machine operation along with earthquake loading on the frame foundation for poor soil conditions. Various alternative foundations like rafts, barrette, batter pile and combinations of barrettes with batter pile are analyzed to study the improvements in the vibration patterns. Detailed computational analysis was carried out in SAP 2000 software; the numerical model was analyzed and compared with the shaking table experiment results. The numerical results are found to be closely matching with the experimental data which confirms the accuracy of the numerical model predictions. Both shake table and SAP 2000 results reveal that combination of barrette and batter piles with raft are best suitable for poor soil conditions because it reduces the displacement at top deck, bending moment and horizontal displacement of pile and thereby making the foundation more stable under seismic loading.

석탑 기단부 적심구성방법에 대한 특성 고찰 - $7{\sim}8$세기 석탑 중 해체 수리한 석탑을 중심으로 - (A study on characteristics of composition method of inner foundation in stone stupa)

  • 정해두;장석하
    • 건축역사연구
    • /
    • 제16권5호
    • /
    • pp.55-66
    • /
    • 2007
  • Through analysing on construction cases of stupa built in A.D. 7,8th, I have researched about these : constructive methods of inner soil of stupa, spatial compositions, characteristics of structures, arrangements of inner soil and etc. And cases analysed are six ; Mireuksajiseoktap(stone pagoda of Mireuksa Temple site), Gameunsajisamcheumgseoktap(three storied stone pagoda of Gameunsa Temple site), Goseonsajisamcheungseoktap(three storied stone pagoda of Goseonsa Temple site), Wolseong nawolliocheungseoktap(five storied stone pagoda in Nawonri, Wolseong), Guksagokseoktap(three storied stone pagoda in Guksa valley), Giamgokseoktap(three storied stone pagoda in Giam valley). Additionally we researched about inner soil of Sacheonwangsaji tapji(basement of stone stupa site in Sacheonwang Temple site) to speculate on composition of Synthetically, the foundation could be divided as core space and outer space. ; the former as structural function and the latter as ornamental function. And the core area could be divided again as center column space and buffer space. The relationship between core spaces and its formation are as belows; First, according to the area of foundation and scale of stone pagoda, formations of core are differed. As the scale of stone pagoda goes bigger, and the area of foundation goes larger, the structure of stone pagoda comprised by center column type and layered-core which endure upper load independently. On the contrary, as the scale of stone pagoda goes smaller, and the area of foundation goes lesser, the structure of stone pagoda tend to use only center column to endure upper part. Second, spatial composition of core area is comprised as two spaces, one which endure upper load and buffer space which absorb side pressure and upper pressure. The buffer space tend to be used in case of those structures which could not endure side pressure or have lots of joint. In some cases, it was located below the cover stone of foundation and gained upper load. And in case that have not gained pressure from side stone, the buffer space are comprised by smalle stone or roof tile to get structural supplement.

  • PDF

5MW급 해상풍력발전기 모노파일 기초의 수직도 오차에 따른 거동 분석 (Behavior Analysis by Verticality Error of Monopile Foundation for 5MW Offshore Wind Turbine)

  • 장화섭;김호선;음학진;김만응
    • 대한토목학회논문집
    • /
    • 제32권2C호
    • /
    • pp.61-68
    • /
    • 2012
  • 일반적으로 해양 말뚝기초의 경우 해양 환경적 영향 및 시공상의 오차로 인해 수직도 오차가 필연적으로 발생한다. 해양구조물의 경우 수평하중이 아닌 수직하중에 의해 설계가 지배적이나, 해상풍력발전기 기초의 경우 수평하중이 지배적이며, 블레이드 회전에 의한 동적인 운동을 하는 구조형식으로 수직도 오차가 구조적으로 중요한 영향을 끼칠 수 있다. 이에 본 연구에서는 5MW급 해상풍력발전기 모노파일 기초의 수직도 오차에 따른 기초와 지반의 구조응답 특성을 분석하였다. 해양환경하중은 ISO 기준에 의해 산정하였으며, 수직도 오차 범위는 $L/{\infty}$(=0), L/300, L/200 및 L/100로 선정하였다. 해석결과 수직도 오차가 없는 모노파일에 비해 L/100 오차를 갖는 지반의 부재력 최대 값이 약 7.2%정도 더 증가되는 것으로 분석되었다.

Nonlinear shear-flexure-interaction RC frame element on Winkler-Pasternak foundation

  • Suchart Limkatanyu;Worathep Sae-Long;Nattapong Damrongwiriyanupap;Piti Sukontasukkul;Thanongsak Imjai;Thanakorn Chompoorat;Chayanon Hansapinyo
    • Geomechanics and Engineering
    • /
    • 제32권1호
    • /
    • pp.69-84
    • /
    • 2023
  • This paper proposes a novel frame element on Winkler-Pasternak foundation for analysis of a non-ductile reinforced concrete (RC) member resting on foundation. These structural members represent flexural-shear critical members, which are commonly found in existing buildings designed and constructed with the old seismic design standards (inadequately detailed transverse reinforcement). As a result, these structures always experience shear failure or flexure-shear failure under seismic loading. To predict the characteristics of these non-ductile structures, efficient numerical models are required. Therefore, the novel frame element on Winkler-Pasternak foundation with inclusion of the shear-flexure interaction effect is developed in this study. The proposed model is derived within the framework of a displacement-based formulation and fiber section model under Timoshenko beam theory. Uniaxial nonlinear material constitutive models are employed to represent the characteristics of non-ductile RC frame and the underlying foundation. The shear-flexure interaction effect is expressed within the shear constitutive model based on the UCSD shear-strength model as demonstrated in this paper. From several features of the presented model, the proposed model is simple but able to capture several salient characteristics of the non-ductile RC frame resting on foundation, such as failure behavior, soil-structure interaction, and shear-flexure interaction. This confirms through two numerical simulations.

Seismic vulnerability of reinforced concrete building structures founded on an XPS layer

  • Koren, David;Kilar, Vojko
    • Earthquakes and Structures
    • /
    • 제10권4호
    • /
    • pp.939-963
    • /
    • 2016
  • According to the new directives about the rational and efficient use of energy, thermal bridges in buildings have to be avoided, and the thermal insulation (TI) layer should run without interruptions all around the building - even under its foundations. The paper deals with the seismic response of multi-storeyed reinforced concrete (RC) frame building structures founded on an extruded polystyrene (XPS) layer placed beneath the foundation slab. The purpose of the paper is to elucidate the problem of buildings founded on a TI layer from the seismic resistance point of view, to assess the seismic behaviour of such buildings, and to search for the critical parameters which can affect the structural and XPS layer response. Nonlinear dynamic and static analyses were performed, and the seismic response of fixed-base (FB) and thermally insulated (TI) variants of nonlinear RC building models were compared. Soil-structure interaction was also taken into account for different types of soil. The results showed that the use of a TI layer beneath the foundation slab of a superstructure generally induces a higher peak response compared to that of a corresponding system without TI beneath the foundation slab. In the case of stiff structures located on firm soil, amplification of the response might be substantial and could result in exceedance of the superstructure's moment-rotation plastic hinge capacities or allowable lateral roof and interstorey drift displacements. In the case of heavier, slenderer, and higher buildings subjected to stronger seismic excitations, the overall response is governed by the rocking mode of oscillation, and as a consequence the compressive strength of the XPS could be insufficient. On the other hand, in the case of low-rise and light-weight buildings, the friction capacity between the layers of the applied TI foundation set might be exceeded so that sliding could occur.