• 제목/요약/키워드: Foundation failure

검색결과 337건 처리시간 0.021초

Strength of connection fixed by TOBs considering out-of-plane tube wall deformation-Part 1: Tests and numerical studies

  • Wulan, Tuoya;Wang, Peijun;Xia, Chengxin;Liu, Xinyu;Liu, Mei;Liu, Fangzhou;Zhao, Ou;Zhang, Lulu
    • Steel and Composite Structures
    • /
    • 제42권1호
    • /
    • pp.49-57
    • /
    • 2022
  • This paper presents a study on the behavior of a bolted T-stub to square tube connection using Thread-fixed One-side Bolts (TOBs) through tests and numerical simulations. It outlines a research work of four connections with focus on the failure modes and strengths of the connection under tensile load. It was observed that the thread anchor failure caused by shear failure of hole threads controlled the final failure of the connection in the tests. Meanwhile, the out-of-plane deformation of tube wall resulted in the contact separation between hole threads and bolt threads, which in turn reduced the shear strength of hole threads. Finite element models (FEMs) allowing for the configuration details of the TOBs fixed connection are then developed and compared with the test results. Subsequently, the failure mechanism of hole threads and stress distribution of each component are analyzed based on FEM results. It was concluded that the ultimate strength of connection was not only concerned with the shear strength of hole threads, but also was influenced by the plastic out-of-plane deformation of tube wall. These studies lay a foundation for the establishment of suitable design methods of this type of connection.

해양환경하중 및 지반의 불확실성을 고려한 중력식 해상풍력 기초의 신뢰성 해석 (Reliability Analysis of Gravity-based Offshore Wind Turbine Foundation Considering Ocean Environmental Loads and Soil Uncertainty)

  • 이상근;김동현
    • 한국해양공학회지
    • /
    • 제29권5호
    • /
    • pp.359-365
    • /
    • 2015
  • A reliability analysis of the gravity-based foundation of anoffshore wind turbine was performed by considering the uncertainties of the design variables, including environmental loads. The limit state functions of the gravity-based foundation were defined using the response limits of the support structures suggested in the DNV standard. The wind load couldbe obtained using the GH_bladed software, and the wave load was calculated using the Morison equation. Then, the extreme distributions of the wind and wave loads were estimated by applying the peak over threshold (POT) method to the wind and wave load data. The probability distribution characteristics of the soil properties were defined with reference to a southwest coast geotechnical survey report. The reliability index was evaluated for each failure mode using a first-order reliability method.

Damage assessment based on static and dynamic responses applied to foundation beams

  • Orbanich, Claudio J.;Ortega, Nestor F.;Robles, Sandra I.;Rosales, Marta B.
    • Structural Engineering and Mechanics
    • /
    • 제72권5호
    • /
    • pp.585-595
    • /
    • 2019
  • Foundations are a vital part of structures. Over time, the foundations can deteriorate due to unforeseen overloads and/or settlements, resulting in the appearance of cracks in the concrete. These cracks produce changes in the static and dynamic behavior of the affected foundation, which alter its load carrying capacity. In this work, non-destructive techniques of relative simplicity of application are presented for the detection, location, and quantification of damage, using numerical models, solved with the finite element method and Power Series. For this, two types of parameters are used: static (displacement and elastic curvature) and dynamics (natural frequencies). In the static analysis, the damage detection is done by means of a finite elements model representing a beam supported on an elastic foundation with a discrete crack that varies in length and location. With regard to dynamic analysis, the governing equations of the model are presented and a method based on Power Series is used to obtain the solution for a data set, which could be the Winkler coefficient, the location of the crack or the frequency. In order to validate the proposed methodologies, these techniques are applied to data obtained from laboratory tests.

Ultimate bearing capacity of conical shell foundations

  • Colmenares, J.E.;Kang, So-Ra;Shin, Young-Jin;Shin, Jong-Ho
    • Structural Engineering and Mechanics
    • /
    • 제52권3호
    • /
    • pp.507-523
    • /
    • 2014
  • Shell foundations have been employed as an alternative for the conventional flat shallow foundations and have proven to provide economical advantage. They have shown considerably improved performance in terms of ultimate capacity and settlement characteristics. However, despite conical shell foundations are frequently used in industry, the theoretical solutions for bearing capacity of these footings are available for only triangular shell strip foundations. The benefits in design aspects can be achieved through theoretical solutions considering shell geometry. The engineering behavior of a conical shell foundation on mixed soils was investigated experimentally and theoretically in this study. The failure mechanism was obtained by conducting laboratory model tests. Based on that, the theoretical solution of bearing capacity was developed and validated with experimental results, in terms of the internal angle of the cone. In comparison to the circular flat foundation, the results show 15% increase of ultimate load and 51% decrease of settlement at an angle of intersection of $120^{\circ}$. Based on the results, the design chart of modified bearing capacity coefficients for conical shell foundation is proposed.

Estimation of ultimate bearing capacity of shallow foundations resting on cohesionless soils using a new hybrid M5'-GP model

  • Khorrami, Rouhollah;Derakhshani, Ali
    • Geomechanics and Engineering
    • /
    • 제19권2호
    • /
    • pp.127-139
    • /
    • 2019
  • Available methods to determine the ultimate bearing capacity of shallow foundations may not be accurate enough owing to the complicated failure mechanism and diversity of the underlying soils. Accordingly, applying new methods of artificial intelligence can improve the prediction of the ultimate bearing capacity. The M5' model tree and the genetic programming are two robust artificial intelligence methods used for prediction purposes. The model tree is able to categorize the data and present linear models while genetic programming can give nonlinear models. In this study, a combination of these methods, called the M5'-GP approach, is employed to predict the ultimate bearing capacity of the shallow foundations, so that the advantages of both methods are exploited, simultaneously. Factors governing the bearing capacity of the shallow foundations, including width of the foundation (B), embedment depth of the foundation (D), length of the foundation (L), effective unit weight of the soil (${\gamma}$) and internal friction angle of the soil (${\varphi}$) are considered for modeling. To develop the new model, experimental data of large and small-scale tests were collected from the literature. Evaluation of the new model by statistical indices reveals its better performance in contrast to both traditional and recent approaches. Moreover, sensitivity analysis of the proposed model indicates the significance of various predictors. Additionally, it is inferred that the new model compares favorably with different models presented by various researchers based on a comprehensive ranking system.

실트질 모래지반에 설치된 해상풍력 석션버켓기초의 신뢰성 해석 (Reliability Analysis of Suction Bucket Foundation for Offshore Wind Turbine in Silty Sand)

  • 윤길림;이진학;배경태;김선빈
    • 한국지반환경공학회 논문집
    • /
    • 제20권12호
    • /
    • pp.41-47
    • /
    • 2019
  • 본 논문에서는 서남해 해상풍력 실증단지 해역을 대상으로 석션버켓기초의 지지력에 대한 신뢰성 분석에 대한 내용을 다루었다. 5MW급 해상풍력터빈의 콘크리트 석션버켓기초를 선정하여 기초 설치 후 연직지지력과 수평지지력에 대한 파괴확률을 계산하고 설계변수의 민감도를 분석하였다. AFOSM을 이용한 신뢰성해석을 수행한 결과, 기초-지반 분리거동 시 연직지지력에 대한 파괴확률이 가장 큰 것으로 나타났으며 기초지반의 단위중량과 내부마찰각이 지배적인 영향인자임을 확인하였다.

대단면 터빈기초 구조물의 발파해체 시공사례 (A Case Study on Explosive Demolition of a Large Section Turbine Foundation Structure)

  • 박훈;남성우;노유송;석철기
    • 화약ㆍ발파
    • /
    • 제40권3호
    • /
    • pp.54-65
    • /
    • 2022
  • 최근 대규모 산업구조물의 해체수요가 증가하고 있으며, 해체된 산업부지를 원래 자연환경으로 복원하는 공사가 진행하고 있다. 본 시공사례는 구조적 노후화와 기능적 요건을 만족하지 못하는 대단면 철근콘크리트 구조물인 터빈기초를 해체하기 위해 발파해체공법을 적용하였다. 발파해체 결과 터빈기초의 파쇄상태는 양호하였고, 주변 시설물의 피해 없이 발파해체를 완료하였다.

파이프 골조온실의 원주형 콘크리트 기초의 인발저항력에 관한 연구 (A Study on the Uplift Capacity of Cylindrical Concrete Foundations for Pipe-Framed Greenhouse)

  • 윤용철;윤충섭;서원명;강만호
    • 한국농공학회지
    • /
    • 제40권4호
    • /
    • pp.109-119
    • /
    • 1998
  • Recently pipe-framed greenhouses are widely constructed on domestic farm area. These greenhouses are extremely light-weighted structures and so are easily damaged under strong wind due to the lack of uplift resistance of foundation piles. This experiment was carried out by laboratory soil tank to investigate the displacement be haviors of cylindrical pile foundations according to the uplift loads. Tested soils were sampled from two different greenhouse areas. The treatment for each soil type are consisted of 3 different soil moisture conditions, 2 different soil depths, and 3 different soil compaction ratios. Each test was designed to be repeated 2 times and additional tests were carried out when needed. The results are summarized as follows : 1. When the soil moisture content are low and/or pile foundations are buried relatively shallow, ultimate uplift capacity of foundation soil was generated just after begining of uplift displacement. But under the high moisture conditions and/or deeply buried depth, ultimate up-lift capacity of foundation soil was generated before the begining of uplift displacement. 2. For the case of soil S$_1$, the ultimate uplift capacity of piles depending on moisture contents was found to be highest in optimum moisture condition and in the order of air dryed and saturated moisture contents. But for the case of soil S$_2$, the ultimate uplift capacity was found to be highest in optimum moisture condition and in the order of saturated and air dryed moisture contents. 3. Ultimate uplift capacities are varied depending on the pile foundation soil moisture conditions. Under the conditions of optimum soil moisture contents with 60cm soil depth, the ultimate uplift capacity of pile foundation in compaction ratio of 80%, 85%, and 90% for soil 51 are 76kg, 115kg, and 155kg, respectively, and for soil S$_2$are 36kg, 60kg, and 92kg, respectively. But considering that typical greenhouse uplift failure be occurred under saturnted soil moisture content which prevails during high wind storm accompanying heavy rain, pile foundation is required to be designed under the soil condition of saturated moisture content. 4. Approximated safe wind velosities estimated for soil sample S$_1$and S$_2$are 32.92m/s and 26.58m/s respectively under the optimum soil condition of 90% compaction ratio and optimum moisture content. But considering the uplift failure pattern under saturated moisture contents which are typical situations of high wind accompanying heavy rain, the safe wind velosities for soil sample S$_1$and S$_2$are not any higher than 20.33m/s and 22.69m/s respectively.

  • PDF

Behaviour of Shallow Foundations Subjected to Blast Loads and Related Liquefaction

  • Ritika, Sangroya;Choudhury, Deepankar;Park, Young Jin;Shin, Eun Chul
    • 한국지반환경공학회 논문집
    • /
    • 제18권10호
    • /
    • pp.5-14
    • /
    • 2017
  • In recent years, world has witnessed many man-made activities related to both above and underground blasts. Details on behaviour of shallow foundations subjected to blast loads and induced liquefaction is scarce in literature. In this paper, typical shallow strip foundation in saturated cohesionless soils subjected to both above and underground blasting have been simulated by using finite difference based numerical model FLAC3D. Peak particle velocity (PPV) has been obtained to propose critical values for which bearing capacity failure for shallow foundations with soil liquefaction can occur. Typical results for pore pressure ratio (PPR) for various scaled distances are compared to PPR values obtained by using empirical equation available in literature which shows good agreement. Critical design values obtained in the present study for PPV and PPR to estimate the scaled distance, bearing capacity failure and liquefaction susceptibility can be used effectively for design of shallow strip foundation in cohesionless soil subjected to both above and under ground blast loads.

정재하시험 결과를 통한 타입말뚝 지지력 공식의 타당성 분석 (A Study on the Applicability of Bearing Capacity Formulas of Driven Pile by Comparison with the Results of Static Loading Tests)

  • 천병식;이승범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.544-551
    • /
    • 2004
  • Piles are structural elements made of steel, concrete or timber, and utilize as pile foundation which is one of deep foundations. Driven pile among them, which drives pile into the ground, is fast-constructable, less expensive and it supplies much bearing capacity. For these reasons, its demand is steady. In this study, by selecting the cases which reached ultimate failure during in-situ static loading tests, bearing capacities acquired from these tests were compared with those computed by existing theories and formula. As the results of the analysis, ultimate bearing capacity computed by theoretic formula were less or similar to those of test results in most cases, but lower ground water level and more dense layer where end of piles were reached remarkably high bearing capacity in theoretical methods. ${\beta}-method$ and Korean structure foundation design standard were sensitive to ground physical properties. Meyerhof metbod and API code were relatively independent from site condition.

  • PDF