• 제목/요약/키워드: Fouling surface

검색결과 278건 처리시간 0.027초

막표면의 케이크층 세정 방법에 따른 여과 저항값 비교 (Comparison of Filtration Resistances according to Membrane Cleaning Methods)

  • 한송희;장인성
    • 한국환경과학회지
    • /
    • 제25권6호
    • /
    • pp.817-827
    • /
    • 2016
  • The resistance in series model has been frequently used for determination of various filtration resistance to correctly understand the membrane fouling behaviour in MBR (membrane bio-reactor) for wastewater treatment. The cake layer resistance ($R_c$) which is commonly determined by calculation of flux dataset that are obtained empirically before and after removing the cake layer on membrane surface. However, the calculated Rc values are very dependent on the cleaning methods adapted for removal of cake layer. This study investigated how the various cleaning options affect $R_c$. Seven different cleaning methods were employed: i) ultrasonication (100 W, 10 min), ii) ultrasonication (200 W, 60 min), iii) ultrasonication (400 W, 120 min), iv) water rinsing in a shaker (100 rpm, 10 min), v) water rinsing in a shaker (300 rpm, 60 min), vi) water rinsing, vii) sponge scrubbing. For the hydrophilic PES membrane, the cake layer removal efficiencies ranged from 64% to 10%, indicating that the removal of cake layer was highly dependent on the cleaning options. For the hydrophobic PVDF membrane, the cake layer removal efficiencies ranged from 79% to 97%. Consequently, a standardized method for cake layer removal to determine cake resistance ($R_c$) is needed for correct interpretation of the fouling phenomena.

Multi-Dimension Scaling as an exploratory tool in the analysis of an immersed membrane bioreactor

  • Bick, A.;Yang, F.;Shandalov, S.;Raveh, A.;Oron, G.
    • Membrane and Water Treatment
    • /
    • 제2권2호
    • /
    • pp.105-119
    • /
    • 2011
  • This study presents the tests of an Immersed Membrane BioReactor (IMBR) equipped with a draft tube and focuses on the influence of hydrodynamic conditions on membrane fouling in a pilot-scale using a hollow fiber membrane module of ZW-10 under ambient conditions. In this system, the cross-flow velocities across the membrane surface were induced by a cylindrical draft-tube. The relationship between cross-flow velocity and aeration strength and the influence of the cross-flow on fouling rate (under various hydrodynamic conditions) were investigated using Multi-Dimension Scaling (MDS) analysis. MDS technique is especially suitable for samples with many variables and has relatively few observations, as the data about Membrane Bio-Reactor (MBR) often is. Observations and variables are analyzed simultaneously. According to the results, a specialized form of MDS, CoPlot enables presentation of the results in a two dimensional space and when plotting variables ratio (output/input) rather than original data the efficient units can be visualized clearly. The results indicate that: (i) aeration plays an important role in IMBR performance; (ii) implementing the MDS approach with reference to the variables ratio is consequently useful to characterize performance changes for data classification.

Design, fabrication, and performance analysis of a twisted hollow fibre membrane module configuration

  • Palmarin, Matthew J.;Young, Stephanie;Lee, Tsun Ho
    • Membrane and Water Treatment
    • /
    • 제6권1호
    • /
    • pp.15-26
    • /
    • 2015
  • The compact structure and high-quality effluent of membrane bioreactors make them well-suited for decentralized greywater reclamation. However, the occurrence of membrane fouling continues to limit their effectiveness. To address this concern, a unique membrane module configuration was developed for use in a decentralized greywater treatment system. The module featured local aeration directly below a series of inclined membrane bundles, giving the overall module a twisted appearance compared to a module with vertically orientated fibres. The intent of this design was to increase the frequency and intensity of collisions between rising air bubbles and the membrane surface. Material related to the construction of custom-fit modules is rarely communicated. Therefore, detailed design and assembly procedures were provided in this paper. The twisted module was compared to two commercially available modules with diverse specifications in order to assess the relative performance and marketability of the twisted module with respect to existing products. Contaminant removal efficiencies were determined in terms of biochemical oxygen demand, chemical oxygen demand, ammonia, total nitrogen, total phosphorus, and turbidity for each module. Membrane fouling was monitored in terms of permeate flux, transmembrane pressure, and membrane resistance. Following 168 h of operation, the twisted module configuration demonstrated competitive performance, indicating good potential for further development and commercialization.

아르곤 플라즈마를 이용하여 유리기판에 증착된 PTFE 박막의 초친수 특성 연구 (Hydrophobic Properties of PTFE Film Deposited on Glass Surface Etched by Ar-plasma)

  • 이병로;배강;김화민
    • 한국전기전자재료학회논문지
    • /
    • 제27권8호
    • /
    • pp.516-521
    • /
    • 2014
  • An excellent hydrophobic surface has a high contact angle over 147 degree and the contact angle hysteresis below $5^0$ was produced by using roughness combined with hydrophobic PTFE coatings, which were also confirmed to exhibit an extreme adhesion to glass substrate. To form the rough surface, the glass was etched by Ar-plasma. A very thin PTFE film was coated on the plasma etched glass surface. Roughness factors before or after PTFE coating on the plasma etched glass surface, based on Wensel's model were calculated, which agrees well with the dependence of the contact angle on the roughness factor is predicted by Wensel's model. The PTFE films deposited on glass by using a conventional rf-magnetron sputtering. The glass substrates were etched Ar-plasma prior to the deposition of PTFE. Their hydrophobicities are investigated for application as a anti-fouling coating layer on the screen of displays. It is found that the hydrophobicity of PTFE films mainly depends on the sputtering conditions, such as rf-power, Ar gas content introduced during deposition. These conditions are closely related to the deposition rate or thickness of PTFE film. Thus, it is also found that the deposition rate or the film thickness affects sensitively the geometrical morphology formed on surface of the rf-sputtered PTFE films. In particular, 1,950-nm-thick PTFE films deposited for 30 minute by rf-power 50 watt under Ar gas content of 20 sccm shows a very excellent optical transmittance and a good anti-fouling property and a good durability.

막결합형 연속회분식 생물반응조에서 여과 및 공기공급용으로 분리막을 사용할 때 공기공급이 막여과 성능에 미치는 영향 (Filtration Performance in MSBR (Membrane-Coupled Sequencing Batch Reactor) using a Membrane for Both Filtration and Aeration)

  • 류관영;박병규;이정학
    • 한국물환경학회지
    • /
    • 제21권4호
    • /
    • pp.337-346
    • /
    • 2005
  • An MSBR using a membrane for not only filtration but also aeration (MA-MSBR) was designed to reduce membrane fouling and to enhance water quality, and compared with an MSBR using a membrane for only filtration (BA-MSBR). COD removal efficiency of the MA-MSBR was similar to that of the BA-MSBR, but membrane performance of the MA-MSBR was better than that of the BA-MSBR. The MA-MSBR had more small particles in mixed liquor, so the specific cake resistance of flocs in the MA-MSBR was higher than that in the BA-MSBR. However, in the aerobic reaction step of the MA-MSBR, air went through membrane pores and out of the membrane surface, so cake layers on the membrane surface and a portion of organics adsorbed on membrane pores could be removed periodically. Therefore, cake resistance, $R_c$, and fouling resistance by adsorption and blocking, $R_f$, for the MA-MSBR increased more slowly than those for the BA-MSBR. Additionally, in order to compare the energy efficiency for two MSBRs, oxygen transfer efficiency and power to supply air into the reactor by a membrane module and a bubble stone diffuser were measured using deionized water. From these measurements, the transferred oxygen amount per unit energy was calculated, resulting that of MA-MSBR was slightly higher than that of BA-MSBR.

고탁도 원수대응 침지식 멤브레인 여과에서 공기폭기 및 용액조성에 따른 파울링 및 처리효율 관찰 (Observations of Treatment Efficiency and Fouling in Submerged Membrane Filtration Treating High-Turbidity Source Water)

  • 장호석;변영권;김정환
    • 멤브레인
    • /
    • 제27권1호
    • /
    • pp.77-83
    • /
    • 2017
  • 무기실리카 입자로 구성된 고탁도 원수를 처리하는 침지식 정밀여과 운전에서 휴민산과 2가 양이온의 존재유무에 따라 시간에 따른 파울링 저항을 관찰하였다. 공기폭기로 인한 무기실리카 입자의 파울링 감소효과는 휴민산과 칼슘이 혼합으로 존재 시 감소하였다. 파울링층의 전자현미경 관찰결과 칼슘의 존재 시 휴민산의 무기실리카 입자 표면흡착이 관찰되었다. 이는 멤브레인 표면에 조밀한 파울링층을 형성시켜 공기폭기 효과를 감소시킨 것으로 판단된다. 용액의 조성에 따른 고탁도 원수의 탁도 제거율에는 큰 변화가 없었으나 공기폭기량에 따라 칼슘과 무기실리카 입자의 혼합 존재 시 유기물질의 제거율은 80% 이상으로 증가하였다. 이는 공기폭기 하에 무기실리카 입자 표면에 흡착된 일부 휴민산들이 멤브레인 표면으로부터 함께 역수송 되어 유기물질 제거율을 증가시킨 것으로 사료된다.

극전환 전해 반응기를 이용한 양식 폐수 내 암모니아 제거 (Removal of Ammonia in Aquaculture Wastewater by Electrolysis with Switching Poles)

  • 강기문;김아람;원용선;이제근;임준혁
    • 청정기술
    • /
    • 제21권1호
    • /
    • pp.45-52
    • /
    • 2015
  • 본 연구에서는 양식 폐수 중 암모니아를 제거하는 전기분해 공정에 극전환을 도입하여 전극 표면에 불용성 금속화합물이 형성되는 오염 현상을 방지하고자 하였다. 한편 극전환으로 인한 전류 손실이 유리염소 이온의 생성에 미치는 영향을 파악함으로서 최적의 극전환 주기를 찾고자 하였다. 먼저 극전환 주기가 짧아지면서 전류손실로 인해 유리염소 이온의 형성 효율이 떨어지는 것을 확인하였으며 이는 암모니아 제거 효율이 감소함을 의미한다. 이에 극전환 주기에 따른 폐수 중의 칼슘과 마그네슘의 농도를 측정해 본 결과 극전환 주기를 60초 이하로 유지하면 극전환에 의한 불용성 금속화합물의 분해를 통해 전극 표면의 오염 현상을 충분한 수준에서 방지할 수 있음을 확인하였다. 따라서 높은 유리염소 이온의 생성효율 유지와 전극 오염 방지라는 두 가지 운전목적 사이에서 최적의 극전환 주기는 60초이었다.

에폭시수지 생산 공정에서 발생되는 brine 폐수의 전처리를 위한 응집 및 침전 반응의 최적화 연구 (A Study on The Optimization of Pre-treatment for the Brine Wastewater from the Epoxy-resin Process by the Coagulation and Sedimentation Reactions)

  • 조욱상;이은영;강성욱;이장수;진수익
    • 청정기술
    • /
    • 제11권2호
    • /
    • pp.57-67
    • /
    • 2005
  • 에폭시 수지는 ECH(Epichlorohydrin)와 BPA(Bisphenol-A)를 원료로 가성소다 존재 하에 탈수응축 반응을 통해 생성되며 반응 부산물로 소금물이 폐수로 발생되는데 이를 Brine이라 부르며 글리시돌과 같은 에멀젼 상태의 ECH 유도체와 수지성 폴리머를 함유하는 알카리성 폐수이다. 이러한 폐수는 폐수처리 과정에서 반응기 내부와 배관 내벽에 폴리머 입자가 침적 및 응고되어 plugging을 일으키는 등 전체적으로 후처리 공정에서 fouling 현상이 발생되고 있는데 이는 미생물의 분해 활성도를 급격히 떨어뜨려 폐수처리 효율이 낮아지는 문제점을 야기 시키고 있다. 본 연구에서는 무기 응집제와 유기 고분자 응집제를 이용하여 에폭시 수지 생산 공정에서 발생하는 brine 폐수에 존재하는 ECH 유도체와 수지성 폴리머를 반고상 슬러지 형태로 응집 및 침전시킴으로써 fouling 현상을 일으키는 요인을 제거하고자 최적의 응집반응 조건을 도출하였고 경제성 분석 등 이를 실제 공정에 적용할 수 있는 방안을 제시하고자 하였다.

  • PDF

MBR에서 간헐포기에 의한 오염저감 효과 (Effects of Fouling Reduction by Intermittent Aeration in Membrane Bioreactors)

  • 최영근;김현철;노수홍
    • 멤브레인
    • /
    • 제25권3호
    • /
    • pp.276-286
    • /
    • 2015
  • 30 LMH의 정유량 플럭스로 운전하는 MBR에서, 휴지 및 역세정에 따른 한외여과 분리막의 오염을 조사하였다. 또한, 연속적인 공기세정과 비교하여 분리막 여과저항을 최소화하기 위한 간헐적인 공기세정을 평가하였다. 여과 조건은 14.5분 여과와 0.5분의 휴지를 유지하였으며, 역세정 시간은 휴지 시간과 동일하게 운전하였다. 공기세정이 정지하는 동안에 분리막 표면의 겔층 위에 케?이 빠르게 축척되었으며, 역세정으로 겔층과 케?층의 복합층은 쉽게 제거되었다. 역세정 후에 공기세정이 정지하는 동안 분리막 표면에 케?이 형성되어 공경 내부의 오염현상을 억제하였다. Pearson 상관성을 조사한 결과, 간헐적인 공기세정에서 공기 세정이 정지하는 시간과 분리막의 오염은 매우 연관성이 높다는 것을 알았다. 즉, 간헐적인 세정에서 공기세정이 정지하는 시간이 갈수록 오염억제에 효과적이었다.

Ultrafiltration membranes for drinking-water production from low-quality surface water: A case study in Spain

  • Rojas-Serrano, Fatima;Alvarez-Arroyo, Rocio;Perez, Jorge I.;Plaza, Fidel;Garralon, Gloria;Gomez, Miguel A.
    • Membrane and Water Treatment
    • /
    • 제6권1호
    • /
    • pp.77-94
    • /
    • 2015
  • Ultrafiltration membranes have several advantages over conventional drinking-water treatment. However, this technology presents major limitations, such as irreversible fouling and low removal of natural organic matter. Fouling depends heavily on the raw-water quality as well as on the operating conditions of the process, including flux, permeate recovery, pre-treatment, chemical cleaning, and backwashing. Starting with the premise that the optimisation of operating variables can improve membrane performance, different experiments were conducted in a pilot plant located in Granada (Spain). Several combinations of permeate and backwashing flow rates, backwashing frequencies, and aeration flow rates were tested for low-quality water coming from Genil River with the following results: the effluent quality did not depend on the combination of operating conditions chosen; and the membrane was effective for the removal of microorganisms, turbidity and suspended solids but the yields for the removal of dissolved organic carbon were extremely low. In addition, the threshold transmembrane pressure (-0.7 bar) was reached within a few hours and it was difficult to recover due to the low efficiency of the chemical cleanings. Moreover, greater transmembrane pressure due to fouling also increased the energy consumption, and it was not possible to lower it without compromising the permeate recovery. Finally, the intensification of aeration contributed positively to lengthening the operation times but again raised energy consumption. In light of these findings, the feasibility of ultrafiltration as a single treatment is questioned for low-quality influents.