• Title/Summary/Keyword: Fossil fuel consumption

Search Result 153, Processing Time 0.029 seconds

Assessment of Carbon Emission for Quantification of Environmental Load on Structural Glued Laminated Timber in Korea (국산 구조용 집성재의 환경부하 정량화를 위한 온실가스 배출량 분석)

  • Chang, Yoon-Seong;Kim, Sejong;Son, Whi-Lim;Lee, Sang-Joon;Shim, Kug-Bo;Yeo, Hwanmyeong;Kim, Kwang-Mo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.449-456
    • /
    • 2016
  • This study was aimed to quantify the amount of carbon dioxide emissions and to suggest suitable plans which consider the carbon emission reduction in the manufacturing process of the domestic structural glued laminated timber. Field investigation on two glued laminated timber manufacturers was conducted to find out material flow input values such as raw materials, transportation, manufacturing process, and energy consumption during manufacturing process. Based on the collected data and the relevant literatures about life cycle inventory (LCI), the amount of carbon dioxide emission per unit volume was quantified. Results show that the carbon dioxide emissions for sawing, drying and laminating process are 31.0, 109.0, 94.2 kg $CO_2eq./m^3$, respectively. These results show 13% lesser amount of total carbon dioxide emissions compared with the imported glued laminated timber in Korea. Furthermore, it was decreased about 37% when the fossil fuel would be replaced with biomass fuel in drying process. Findings from this study is effectively used as the basic data on the life cycle assessment of wooden building.

Performance Characteristics of Organic Rankine Cycles Using Medium Temperature District Heating Water as Heat Source (지역난방용 중온수 열원 유기랭킨사이클 성능 특성)

  • Park, Woo-Jin;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2016
  • It is becoming increasingly important to make use of alternative energy source. because It is not able to rely on only fossil fuel for the recent increasing demand of energy consumption. With this situation, lots of studies for utilizing low grade energy such as industrial waste heat, solar energy, and geothermal energy have been conducted. The aim of this study is to predict the operation characteristics of working fluid by using performance analysis program (ThermoFlex) through the system analysis which is not mixing district return water but using ORC(Organic Rankine Cycle, hereinafter ORC) as a downstream cycle when accumulating district heating (hereinafter DH). In this study, We conducted the performance analysis for the case which has the district heating water temperature($120^{\circ}C$) and Flow rate of $163m^3/h$ (including District Heating return water flow), and examined several working fluid which is proper to this temperature. The case using R245fa (which is the best-case) showed 269.2kW power output, 6.37% efficiency. Additionally, Cut down on fuel was expected because of the boiler inlet temperature increase by being Formed $57.3{\sim}85^{\circ}C$ in a temperature of district heating return water, depending on a pressure change of a condenser in ORC system.

  • PDF

Variation of Indoor Air Temperature by using Hot Water Piping in Greenhouse (온수배관에 의한 온실 내부의 온도변화)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Bae, Seoung-Beom;Kim, Hyeon-Tae;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of agriculture & life science
    • /
    • v.46 no.2
    • /
    • pp.179-190
    • /
    • 2012
  • This study was performed to obtain a heat saving effect and enhance the efficiency of a greenhouse by using a hot water piping in order to minimize the operating costs of a greenhouse as oil prices continue to rise. This method also reduces the likelihood of accidents caused by snowdrifts in regions with heavy snowfall. In general, the experimental plot was $2.0{\sim}6.0^{\circ}C$ higher than the control plot. When the skylight felt was opened, the minimum temperature was in the range of $3.0{\sim}12.0^{\circ}C$. Therefore, we judged that damage caused by snowdrifts may be prevented partly by active heating. The temperature difference inside of the greenhouse by height was insignificant. The maximum heating load of the greenhouse according to crop was respectively about $37,000kcal{\cdot}h^{-1}$ and $41,700kcal{\cdot}h^{-1}$. During the experiment, the heat value of each designed temperature in the range of the minimum ambient temperature $-11.9{\sim}4.0^{\circ}C$ was about 95,000~322,000 kcal and it was in the range of $6,050{\sim}20,900kcal{\cdot}h^{-1}$. If it is compared with the maximum heating load, it can be shown that about 15~56% of the heating energy can be supplied. The total heat value and the amount of power consumption were 2,629,025 kcal and 677.3 kWh respectively during the experiment. If it is heated with diesel, a fossil fuel, the consumption during the experiment was 291 L and the cost was 331,700won. Total cost of using electric power was about 24,400 won and it is shown that it is about 7.5% of the cost of diesel consumption. Also, if the total amount of power consumption is converted into energy, it is approximately 582,200 kcal and the energy was just about 22% of the total heat value.

Environmental Dispute Adjustment System : Current Status and Issues (환경분쟁조정제도의 현황과 과제)

  • Yoon, Esook;Lee, Choon-Won
    • Journal of Arbitration Studies
    • /
    • v.28 no.1
    • /
    • pp.125-151
    • /
    • 2018
  • Rapid industrial growth based on massive fossil fuel energy consumption has caused serious damages on natural environment and every aspects of human life. As demands for clean and pleasant living circumstance increases, conflicts and disputes around environmental problems have also been widespread. Given the 'environmental rights' is a relatively new legal concept, however, resolving environmental disputes through the traditional legal principles and litigation procedures could be restrictive and, in some sense. inefficient as well as expensive. With efforts to develop new legal principles on environmental disputes, the environmental dispute adjustment system has been introduced as an alternative dispute resolution to the traditional legal dispute procedures. The Korean Environmental Dispute Resolution Commission introduced as the environmental dispute adjustment system has been well established for the past twenty-seven years, given the steadily increasing numbers of applications to the Commission over environmental disputes. However, as most cases are still small in money terms and mainly subject to adjudication, the effectiveness and practical contribution of the Commission in the resolution of environmental disputes have in fact been limited. For the enhancement of the status and roles of the Commission as the prior instrument of the alternative dispute resolution(ADR) in environmental disputes, several suggestions could be considered as follows: First, mediation needs to be more activated than adjudication in order to meet the primary purpose of ADR that resolves environmental disputes according to free will of concerned parties. Second, the scope of mediation could be expanded to the areas including potential environmental damages. Third, the roles and responsibilities of the Environmental Dispute Resolution Commissions at both central and local levels need to be evenly distributed. Fourth, the mechanism and procedures of environmental dispute resolution should be standardized. Fifth, the status of the Environmental Dispute Resolution Commission could be elevated in rank by shifting its current affiliation from the Ministry of Environment to the Office of Prime Minister. Sixth, the organizational structure and human resources of the Commission need to be reinforced. Seventh, the current situation that tends to give priority to litigation procedures when an environment dispute is simultaneously pending in litigation and mediation should be eased and properly adjusted. Eighth, the adoption of mandatory mediation in advance to litigation needs to be discussed. Ninth, the legal authority of the Commission's decisions should be further guaranteed. If above suggestions are thoroughly reviewed and properly adopted, the roles, authority and power of the Environmental Dispute Resolution Commission would be increased in the era when environmental conflicts get widespread, requiring an effective alternative environmental dispute resolution mechanism.

Analysis of Environmental Impacts for the Biochar Production and Soil Application (폐목재를 이용한 바이오차 생산 및 토양적용의 환경평가)

  • Kim, Mihyung;Kim, Geonha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.461-468
    • /
    • 2014
  • Biochar is a carbon rich solid produced by the pyrolysis of biomass such as energy crops, forestry residues, and wood wastes. Biochar returned to soil is to mitigate climate change and the feedstock of wood wastes reduces fossil fuel consumption as well as disposal costs. This study was practiced to evaluate a biochar system by gasification in terms of global warming regarding the soil application of the produced biochar. Life cycle assessment methodology was used to analyze the environmental impacts of the system, and the functional unit was 1 tonne of wood wastes. The result shows that the biochar system by using wood wastes as feedstock produces 4.048E-01 $kgCO_2-eq$ from the pre-treatment process as chipping and drying, 4.579E-01 $kgCO_2-eq$ from the pyrolysis process, and 9.070E-02 $kgCO_2-eq$ from the spreading to agricultural land, therefore total 9.534E-01 $kgCO_2-eq$ are generated. About 252 kg of $CO_2$ is still stored in the produced biochar in soil after carbon offsetting of the system. Therefore, the net carbon of the system is -251 kg of $CO_2-eq$.

A Comparative Study on the $CO_2$ Storage Method ($CO_2$ 해양처리방안 비교연구)

  • Jung, R.T.;Kang, S.G.;Kang, C.G.;Park, Y.C.;Yoon, C.H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.8 no.3
    • /
    • pp.111-115
    • /
    • 2005
  • The concentration of atmosphere carbon dioxide ($CO_2$) which is one of the major greenhouse gas, continues to rise by the increase in fossil fuel consumption, forest destruction and decrease of biological diversity, etc. In order to weaken the global warming, a reduction of $CO_2$ discharge to the atmosphere is required. The $CO_2$ ocean sequestration technology utilizes the intrinsic oceanic capacity of $CO_2$ absorption, diluting and/or dispersing the liquefied $CO_2$ in the deep ocean (>2,000 m). This geo-engineering approach is regarded as one of the occasions to mitigate the $CO_2$ concentration in the atmosphere. Some developed centuries such as Japan, USA, Norway, etc. have intensively carried out the projects on the research and development of $CO_2$ ocean sequestration since 1990s. There have been several approaches to develop the relative technological system to mitigate the increasing $CO_2$, however, there was no systematic and practical R&D programme in the $CO_2$ ocean sequestration. This paper has described the state of the art on the three optional methods of $CO_2$ sequestration, and compared with them in the aspect of the applicable possibility.

  • PDF

A Study on Output Enhancement Method of PV Array Using Electrical Circuit Reconfiguration Algorithm (전기적 회로절체 알고리즘에 의한 태양광 어레이의 출력향상 방안에 관한 연구)

  • Kim, Byung-Mok;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.9-17
    • /
    • 2020
  • Recently, RES (renewable energy source) projects have been spreading all over the world as an alternative to solve the shortage of energy and environmental problems caused by fossil fuel consumption. The Korean government also supported the policy and demonstration project to increase the proportion of renewable energy to 63.8[GW] until 2030, which is 20[%] of the total power generation. On the other hand, output loss of a PV array can occur when the surrounding high-rise buildings and trees shade a PV array. Therefore, this paper proposes an algorithm to improve the output loss of a PV array, which electrically changes a circuit configuration of PV modules by wiring and switching devices. Furthermore, this study modeled a PV system based on PSIM S/W, which was composed of a PV array, a circuit configuration device, and a grid-connected inverter. From the simulations results with the modeling and test device, the existing method showed no output when 50% of the shade occurs in PV modules. In contrast, the proposed method could produce the output because the voltage in the PV module could be restored to 246[V], and the operation efficiency of the PV system could be improved by the operation algorithm of the circuit configuration device.

Acetone, Butanol, Ethanol Production from Undaria pinnatifida Using Clostridium sp. (Clostridium 종을 이용한 미역으로부터 아세톤, 부탄올, 에탄올 (ABE) 생산)

  • Kwon, Jeong Eun;Gwak, Seung Hee;Kim, Jin A;Ryu, Ji A;Park, Sang Eon;Baek, Yoon Seo;Heo, A Jeong;Kim, Sung-Koo
    • Microbiology and Biotechnology Letters
    • /
    • v.45 no.3
    • /
    • pp.236-242
    • /
    • 2017
  • The conversion of marine biomass to renewable energy has been considered an alternative to fossil fuels. Butanol, in particular, can be used directly as a fuel. In this experiment, the brown alga Undaria pinnatifida was selected as a biomass for biobutanol production. Hyper thermal (HT) acid hydrolysis was used as an acid hydrolysis method to produce monosaccharides. The optimal pretreatment conditions for U. pinnatifida were determined as slurry with 10% (w/v) U. pinnatifida content and 270 mM $H_2SO_4$, and heating at $160^{\circ}C$ for 7.5 min. Enzymatic saccharification was carried out with Celluclast 1.5 L, Viscozyme L, and Ultraflo Max. The optimal saccharification condition was 12 U/ml Viscozyme L. Fermentations were carried out for the production of acetone, butanol, and ethanol by Clostridium acetobutylicum KCTC 1724, Clostridium beijerinckii KCTC 1785, and Clostridium tyrobutyricum KCTC 5387. The fermentations were carried out using a pH-control. The optimal ABE fermentation condition determined using C. acetobutylicum KCTC 1724 adapted to 160 g/l mannitol. An ABE concentration of 9.05 g/l (0.99 g/l acetone, 5.62 g/l butanol, 2.44 g/l ethanol) was obtained by the consumption of 24.14 g/l monosaccharide with $Y_{ABE}$ of 0.37 in pH 5.0.

Investigation on Properties of Cement Mortar Using Heat Treated Flue Gas Desulfurization Gypsum (열처리된 배연탈황석고를 혼입한 시멘트 모르타르의 물성 연구)

  • Chung, Chul-Woo;Lee, Yong-Mu;Kim, Ji-Hyun;Kim, Young-Su
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.497-503
    • /
    • 2016
  • Flue gas desulfurization gypsum is produced from emission process of fossil fuel power plant to remove sulfur dioxide ($SO_2$) from exhaust gas. Production of flue gas desulfurization gypsum in Republic of Korea has been increasing due to the enforced regulations by government agency. Since flue gas desulfurization gypsum has characteristic that is similar to that of natural gypsum, there is a strong possibility for flue gas desulfurization gypsum to replace the role of natural gypsum. However, consumption of such material is still limited, only used for agricultural purposes or to make gypsum boards, it is necessary to expand the use of this material more aggressively. In this research, the chemical and mineralogical properties of flue gas desulfurization gypsum were investigated, and flue gas desulfurization gypsum with heat treatment was used to make cement paste. According to the results, it was found that flue gas desulfurization gypsum used in this experiment was a very high purity gypsum, and shown to have similar property to that of natural gypsum. Heat treating flue gas desulfurization gypsum above $100^{\circ}C$ was shown to bring beneficial effect on both compressive strength and drying shrinkage

Study on Acidification and Neutralization Characteristics of Precipitation in JejuCity between 1997 and 2005 (1997~2005년 제주시 지역 강수의 산성화 및 중화 특성 연구)

  • Kang Chang-Hee;Hong Sang-Bum;Kim Won-Hyung;Ko Hee-Jung;Lee Sun-Bong;Song Jung-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.4
    • /
    • pp.487-498
    • /
    • 2006
  • Total 438 precipitation samples were collected in Jeju City between 1997 and 2005, and their major ionic components were analyzed. The comparison tests using ion balance, electric conductivity and acid fraction were performed. It was found their correlation coefficients were in the range of 0.977$\sim$0.994, indicating the good quality of collected dam. The volume-weighted mean pH and electric conductivity were 4.8 and 23.0 $\mu$S/cm, respectively. with the ionic strength of 0.23$\pm$0.20 mM. The marine ($Na^+$, $Mg^{2+}$, and $CI^-$), anthropogenic (nss$SO_4{2-}$, $NO_3^-$, and $NH_4^+$) and soil (nss-$Ca^{2+}$) species have contributed to the ionic components of precipitation samples with 43$\sim$74%, 16$\sim$37% and $\sim$5%, respectively. The seasonal variations of $NO_3^-$ and nss-$SO_4^{2-}$ showed a distinct seasonality with higher concentrations in winter than summer, indicating an increase of fossil fuel consumption and a possibility of long-range transport of those pollutants from continental area along the dominant winter westerly. The levels of nss-$Ca^{2+}$ also were appeared the highest in winter and increased comparatively in spring season. possibly due to the soil influences including the Asian Dust. The acidification contribution of nss-$SO_4^{2-}$ and $NO_3^-$ showed 88$\sim$96%, and the free acidity was in the range of 6.0$\sim$40.1%. Interestingly, the backward trajectories for the case of upper 10% nss-$SO_4^{2-}$ and $NO_3^-$ levels have passed through the China continent before their arrival to Jeju. The precipitation of pH below 4.5 has been occurred frequently when the trajectory's path lied over the China continents. On the other hand, the air masses from the North Pacific area were characterized by lower 10% of nss-$SO_4^{2-}$- and $NO_3^-$ concentration, which demonstrated that air mass from the North Pacific was the cleanest among air masses moved to Jeju.