• Title/Summary/Keyword: Forward/Reverse Rotation

Search Result 26, Processing Time 0.026 seconds

Prediction of Power Consumed By Forward and Reverse Rotation Rotavator using Field Load Analysis (필드 부하 분석을 이용한 정/역회전 로타베이터의 소요 동력 예측)

  • Kim, Jeong-Gil;Park, Jin-Sun;Cho, Seung-Je;Lee, Dong-Keun;Park, Young-Jun;Moon, Sang-Gon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.8
    • /
    • pp.67-73
    • /
    • 2021
  • In this study, we installed forward and reverse rotation rotavators on a tractor to measure the load in the field and analyze the power consumed. The rotavator is attached to the rear of the tractor and transmits the power applied from the power take off (PTO) of the tractor to the rotating shaft of the rotavator, and it plows or reverses the soil according to the rotational direction of the rotating shaft. Depending on the rotational direction of the rotavator, the power consumed in the tractor engine and the power transmitted to the tractor axle and rotavator also vary, thus, research of load and power is an essential factor in designing the system. As a field test results, 84.1-93.5% power was consumed by the forward rotation rotavator, and 37.8-57.5% power was consumed by the reverse rotation rotavator. In addition, depending on the rotation direction of the rotavator, the power consumed by the tractor was in the order of PTO and axle. Based on the research results, development of reliable rotavator systems would be possible in the future research.

Comparative analysis of internal flow characteristics of LBE-cooled fast reactor main coolant pump with different structures under reverse rotation accident conditions

  • Lu, Yonggang;Wang, Xiuli;Fu, Qiang;Zhao, Yuanyuan;Zhu, Rongsheng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2207-2220
    • /
    • 2021
  • Lead alloy is used as coolant in Lead-based cooled Fast Reactor (LFR). The natural characteristics of lead alloy are combined with the simple structural design of LFR. This constitutes the inherent safety characteristics of LFR. The main work of this paper is to take the main coolant pump (MCP) in the lead-cooled fast reactor (LFR) as the research object, and to study the flow pattern distribution of the internal flow field under the reverse rotation pump condition, the reverse rotation positive-flow braking condition and the reverse rotation negative-flow braking condition. In this paper, the double-outlet volute type and the space guide vane are selected as the potential designs of the CLEAR-I MCP. In this paper, the CFD method is used to study the potential reverse accident of the MCP. It is found that the highest flow velocity in the impeller appears at the impeller outlet, and the Q-H curves of the two design programs basically coincide. The space guide vane type MCP has better hydraulic performance under the reverse rotation positive-flow condition, the Q-H curves of the two designs gradually separate with increasing flow rate, and the maximum flow velocity inside the space guide vane type MCP is obviously lower than that of the double-outlet volute type. For the reverse rotation test of MCP, only the condition of the forward rotating pump of the main coolant pump is tested and verified. For the simulation of the MCP in LBE medium, it proved that the turbulence model and basic settings selected in the simulation are reliable.

A Dual Log-polar Map Rotation and Scale-Invariant Image Transform

  • Lee, Gang-Hwa;Lee, Suk-Gyu
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.45-50
    • /
    • 2008
  • The Fourier-Mellin transform is the theoretical basis for the translation, rotation, and scale invariance of an image. However, its implementation requires a log-polar map of the original image, which requires logarithmic sampling of a radial variable in that image. This means that the mapping process is accompanied by considerable loss of data. To solve this problem, we propose a dual log-polar map that uses both a forward image map and a reverse image map simultaneously. Data loss due to the forward map sub-sampling can be offset by the reverse map. This is the first step in creating an invertible log-polar map. Experimental results have demonstrated the effectiveness of the proposed scheme.

A Study on the Development of CW(Continuous-Wave)Doppler System for measuring Bi-directional Blood Flow Information (혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구)

  • 강충신;김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.75-80
    • /
    • 1987
  • With the conventional CW Doppler velocity meter, bl-directional velocities cannot be separated. The new CW Doppler system uses quadrature detection and phase rotation to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, we can easily differentiate typical artery flow from vein flow, and measure both velocity characteristics qualitatively.

  • PDF

A FINITE ELEMENT ANALYSIS ON THE EFFECT OF THE REVERSE HEADGEAR TO THE MAXILLARY COMPLEX (REVERSE HEADGEAR가 상악골체에 미치는 영향에 관한 유한요소법적 분석)

  • Kim, Joo-Young;Sohn, Byung-Hwa
    • The korean journal of orthodontics
    • /
    • v.15 no.1
    • /
    • pp.7-22
    • /
    • 1985
  • The purpose of this study was to analyze the stress distribution and the displacement in the maxillary complex after the application of the reverse headgear. The direction of force was parallel to the occlusal plane. Orthopedic force,300gm, was applied to the maxilla of the dry human skull in a forward direction. The stress distribution and the displacement within the maxillary Complex was analyzed by a 3-dimensional finite element method. The results were as follows: 1. The stress distribution at the molar region was greater than that at the anterior. 2. The stress distribution at the lateral side of the premaxilla was greater than that at the middle aide, especially high stress was noted at the canine eminence. 9. Compressive stress was noted only at the frontozygomatic suture of the zygomatic arch. 4. A forward, upward, and sideward displacement was noted at the entire nodal points of the zygomaticomaxillary suture portion. A displacement with a slight rotation was observed on the transverse palatine suture. 5. The maximum stress was observed at the lateral side of the maxillary tuberosity area, and generally the forward and downward displacement was noted at all this area.

  • PDF

Sensorless Control Algorithm of a Surface Mounted PM Synchronous Motor Under Naturally Rotating by Load (외부부하에 의해 회전중인 표면부착형 영구자석동기전동기의 센서리스 제어 알고리즘)

  • Lee, Han-Sol;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.16-23
    • /
    • 2018
  • PM synchronous motor may be rotated to an arbitrary direction and speed by outside wind under natural condition in cases where the fan is applied outside, such as in vehicle radiators and outdoor air-conditioners. Sensorless controls that cannot detect rotor position requires additional sensorless control algorithm because a rotor is rotated by an external load. In this study, the sensorless control of a PM synchronous motor under naturally rotating condition is proposed. The natural rotation conditions are classified as forward high-speed rotation, reverse high-speed rotation, and low-speed rotation. Experiment results verify the performance of the sensorless control, including the rotor speed and position detection at natural rotation mode and switch to the closed-loop sensorless control.

Equilibrium Studies and Thermodynamics for the Mutarotation of Poly(cis-5-methylproline) in Chloroform-Chloroethanol (Chloroform-Chloroethanol 용매중에서 Poly(cis-5-methylproline)의 평형 및 열역학적연구)

  • M. J. Han
    • Journal of the Korean Chemical Society
    • /
    • v.23 no.4
    • /
    • pp.187-197
    • /
    • 1979
  • The molar optical rotation of poly(cis-5-methylproline) was measured in solvent mixtures of chloroform and chloroethanol. After proper allowance for time-dependent mutarota-tions, equilibrium states between form A and form B were observed to occur with a solvent composition of 0.5~10 % chloroethanol in chloroform by volume. From the equilibrium constants, which were calculated by optical rotations at equilibrium measured at three different temperatures (5, 25, and 45 $^{circ}$C), the thermodynamic parameters-free enthalpy, enthalpy and entropy changes for the mutarotation-were evaluated. It was found that starting with equimolar concentrations of form A and form B, the forward mutarotation occurred in the solvent compositions of chloroethanol greater than 3 % by volume, whereas the reverse mutarotation resulted in solvent compositions of chloroethanol less than 3 % by volume. The changes in enthalpy and entropy for the forward mutarotation were found to be positive, while those were for the reverse mutarotation were negative. The driving forces for the forward mutarotation were found to be the increase in entropy, whereas that for the reverse mutarotation was the negative enthalpy change. The thermodynamic data were explained by the interaction between polymer and solvent, i.e., preferential hydrogen bonding of chloroethanol with the carbonyl group in form B over form A, and by difference in conformational energies between form A and form B.

  • PDF

A study on the development of CW(Continuous-Wave) Doppler system for measuring bi-directional blood flow information. (혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구)

  • Kang, Chung-Sin;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1239-1242
    • /
    • 1987
  • With the convention CW Doppler velocity meter, bi-directional velocities cannot be separated. The new CW Doppler system usee quadrature detection and phase rotation to Produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, can easily differentiate typical artery flow from vein flow. and measure both velocity characteristics qualitatively.

  • PDF

An Efficient Image Encryption Scheme Based on Quintuple Encryption Using Gumowski-Mira and Tent Maps

  • Hanchinamani, Gururaj;Kulkarni, Linganagouda
    • International Journal of Contents
    • /
    • v.11 no.4
    • /
    • pp.56-69
    • /
    • 2015
  • This paper proposes an efficient image encryption scheme based on quintuple encryption using two chaotic maps. The encryption process is realized with quintuple encryption by calling the encrypt(E) and decrypt(D) functions five times with five different keys in the form EDEEE. The decryption process is accomplished in the reverse direction by invoking the encrypt and decrypt functions in the form DDDED. The keys for the quintuple encryption/decryption processes are generated by using a Tent map. The chaotic values for the encrypt/decrypt operations are generated by using a Gumowski-Mira map. The encrypt function E is composed of three stages: permutation, pixel value rotation and diffusion. The permutation stage scrambles all the rows and columns to chaotically generated positions. This stage reduces the correlation radically among the neighboring pixels. The pixel value rotation stage circularly rotates all the pixels either left or right, and the amount of rotation is based on chaotic values. The last stage performs the diffusion four times by scanning the image in four different directions: Horizontally, Vertically, Principal diagonally and Secondary diagonally. Each of the four diffusion steps performs the diffusion in two directions (forward and backward) with two previously diffused pixels and two chaotic values. This stage ensures the resistance against the differential attacks. The security and performance of the proposed method is investigated thoroughly by using key space, statistical, differential, entropy and performance analysis. The experimental results confirm that the proposed scheme is computationally fast with security intact.

Short-term outcomes of two-stage reverse total shoulder arthroplasty with antibiotic-loaded cement spacer for shoulder infection

  • Kim, Du-Han;Bek, Chung-Shin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.202-209
    • /
    • 2022
  • Background: The purpose of our study was to investigate short-term outcomes of two-stage reverse total shoulder arthroplasty (RTSA) with an antibiotic-loaded cement spacer for shoulder infection. Methods: Eleven patients with shoulder infection were treated by two-stage RTSA following temporary antibiotic-loaded cement spacer. Of the 11 shoulders, nine had pyogenic arthritis combined with complex conditions such as recurrent infection, extensive osteomyelitis, osteoarthritis, or massive rotator cuff tear and two had periprosthetic joint infection (PJI). The mean follow-up period was 29.9 months (range, 12-48 months) after RTSA. Clinical and radiographic outcomes were evaluated using the visual analog scale (VAS) score for pain, American Shoulder and Elbow Surgeons (ASES) score, subjective shoulder value (SSV), and serial plain radiographs. Results: The mean time from antibiotic-loaded cement spacer to RTSA was 9.2 months (range, 1-35 months). All patients had no clinical and radiographic signs of recurrent infection at final follow-up. The mean final VAS score, ASES score, and SSV were significantly improved from 4.5, 38.6, and 29.1% before RTSA to 1.7, 75.1, and 75.9% at final follow-up, respectively. The mean forward flexion, abduction, external rotation, and internal rotation were improved from 50.0°, 50.9°, 17.7°, and sacrum level before RTSA to 127.3°, 110.0°, 51.8°, and L2 level at final follow-up, respectively. Conclusions: Two-stage RTSA with antibiotic-loaded cement spacer yields satisfactory short-term clinical and radiographic outcomes. In patients with pyogenic arthritis combined with complex conditions or PJI, two-stage RTSA with an antibiotic-loaded cement spacer would be a successful approach to eradicate infection and to improve function with pain relief.