• Title/Summary/Keyword: Forest Fire Characteristics

Search Result 183, Processing Time 0.048 seconds

Fire-Smoke Detection Based on Video using Dynamic Bayesian Networks (동적 베이지안 네트워크를 이용한 동영상 기반의 화재연기감지)

  • Lee, In-Gyu;Ko, Byung-Chul;Nam, Jae-Yeol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.4C
    • /
    • pp.388-396
    • /
    • 2009
  • This paper proposes a new fire-smoke detection method by using extracted features from camera images and pattern recognition technique. First, moving regions are detected by analyzing the frame difference between two consecutive images and generate candidate smoke regions by applying smoke color model. A smoke region generally has a few characteristics such as similar color, simple texture and upward motion. From these characteristics, we extract brightness, wavelet high frequency and motion vector as features. Also probability density functions of three features are generated using training data. Probabilistic models of smoke region are then applied to observation nodes of our proposed Dynamic Bayesian Networks (DBN) for considering time continuity. The proposed algorithm was successfully applied to various fire-smoke tasks not only forest smokes but also real-world smokes and showed better detection performance than previous method.

Application of Remote Sensing and Geographic Information System in Forest Sector (원격탐사와 지리정보시스템의 산림분야 활용)

  • Lee, Woo-Kyun;Kim, Moonil;Song, Cholho;Lee, Sle-gee;Cha, Sungeun;Kim, GangSun
    • Journal of Cadastre & Land InformatiX
    • /
    • v.46 no.2
    • /
    • pp.27-42
    • /
    • 2016
  • Forest accounts for almost 64 percents of total land cover in South Korea. For inventorying, monitoring, and managing such large area of forest, application of remote sensing and geographic information system (RS/GIS) technology is essential. On the basis of spectral characteristics of satellite imagery, forest cover and tree species can be classified, and forest cover map can be prepared. Using three dimensional data of LiDAR(Light Detection and Ranging), tree location and tree height can be measured, and biomass and carbon stocks can be also estimated. In addition, many indices can be extracted using reflection characteristics of land cover. For example, the level of vegetation vitality and forest degradation can be analyzed with VI (vegetation Index) and TGSI (Top Grain Soil Index), respectively. Also, pine wilt disease and o ak w ilt d isease c an b e e arly detected and controled through understanding of change in vegetation indices. RS and GIS take an important role in assessing carbon storage in climate change related projects such as A/R CDM, REDD+ as well. In the field of climate change adaptation, impact and vulnerability can be spatio-temporally assessed for national and local level with the help of spatio-temporal data of GIS. Forest growth, tree mortality, land slide, forest fire can be spatio-temporally estimated using the models in which spatio-temporal data of GIS are added as influence variables.

The analysis of damage characteristics of facility caused by the Forest fire on Ul-ju (울주 산불피해 시설물들의 산림환경 특성분석)

  • Yeom, Chan-Ho;Lee, Si-Yeong;Gwon, Chun-Geun;Park, Heung-Seok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.210-210
    • /
    • 2013
  • 본 연구는 산림 내 시설물의 산림환경 특성 분석을 위하여 2013년 3월 9일부터 10일 이틀 동안 280ha의 산림 피해면적과 57동의 시설물 피해를 준 울주산불에 대하여 현장조사를 실시하였다. 조사 대상물은 주택 15개소, 비닐하우스 1개소, 축사3개소 등 총 19개소에 대하여 2013년 3월부터 5월까지 현지조사를 실시하였다. 조사항목은 시설물의 입지여건, 임상분포, 주변 산불인자, 시설물 외벽구조제, 산불 등 화재진화를 위한 소방시설 여부, 기타 산불 등 화재방지를 위한 시설, 보호시설과 산림과의 거리 등 총 7개 항목을 작성하여 피해시설물 및 미피해시설물의 특성을 분석한 결과 입지여건의 경우 피해시설물과 미피해시설물은 1~2개의 진 출입로를 갖고 있었고, 도로 폭은 7m 내외로 비슷한 여건이었다. 주변 임상은 침엽수, 임분 밀도는 중, 밀임분이었다. 비가연성 외벽구조제는 피해시설물 보다 미피해시설물에 많았고, 피해시설물과 미피해시설물의 시설물 주변 가연물질 관리상태는 모두 양호하였다. 반면, 급수시설 및 스프링클러, 방화선, 방화벽 등 소방시설 및 화재방지 시설은 미피해시설물이 피해시설물보다 더 많이 구축되어 있었고, 산림과의 이격거리는 피해시설물 평균 20m, 미피해시설물 평균 25m로 조사되었다.

  • PDF

Effect of May 31, 2022 Miryang Forest Fire on Fine Particle Concentration in Nearby Urban Areas (2022년 5월 31일 발생한 밀양산불이 인근 도시 지역의 미세먼지 농도에 미치는 영향)

  • Byung-Il Jeon
    • Journal of Environmental Science International
    • /
    • v.32 no.1
    • /
    • pp.37-46
    • /
    • 2023
  • This study investigated the effect of May 31, 2022 Miryang wildfire on fine particle concentrations in Busan and Gimhae, which are neighboring urban areas. In addition, fine particle characteristics and air pollution concentrations were investigated in Miryang, where haze occurred. The Miryang city wildfire that occurred on May 31, 2022, at 0925 LST, was driven by strong north winds and increased fine particle concentrations in Dongsangdong and Jangyoodong, Gimhae City, which are approximately 35 km to the southeast and south, respectively, of the wildfire occurrence site. Furthermore, the fine particle concentration in Myeongjidong, which is approximately 50 km south-southeast of the wildfire site, exhibited a temporary increase at 1400 LST owing to the effects of wildfire smoke. On the morning of June 1, the day after the fire, the Miryang area had very bad visibility because of the smoke from the fire. Therefore the PM10 and PM2.5 concentrations in Naeildong, 3 km south of the wildfire site, were 276 ㎍/㎥ and 222 ㎍/㎥, respectively, at 1200 LST. In addition, the gases O3, CO, and SO2 showed high concentrations at the time of haze generation. This study provides insights into policy making in response to the rapid increase in fine dust when wildfire occurs near cities.

Moisture Content of Litter Layer and Its Combustibility by Cigarette Light in Forests (森林內 落葉層의 含水量과 담뱃불에 의한 可燃性)

  • 김관수;장인수;김수정
    • The Korean Journal of Ecology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 1994
  • This study focuses on forest fires attributed to cigarette light, the main source of wild fires, by examining the characteristics of the fire types. It aims to present useful data for preventive measures. Statistics show that the average length of cigarette butts left after smoking is 30mm excluding filter for domestic cigarette smokers. Also the average thickness of litter layer in forests is 58.2mm throughout the nation. The value varies according to how often leaves were trodden by hikers : the accumulation amount of Mt. Sunchi. which is relatively protected from human disturbances, is 29.6% more than that of Mt. Kye-Ryong National Park. Aged trees such as Pznus rzgidu, Quercus acutissima and Larix leptolepis have relatively large inflammable contents, 2.43kg in 15 year-old stand and 2.55kg in 10 year-old stand. This study found out the following fact with regard to the start of lighting and the out-break of fire. Fire breaks out within five minutes in the sample(C), in which Zoysza gaponica and Populus X tomentiglandulosu has been tramped when the sample has 2~6 percent of moisture contents. Coniferous trees such as Pinus rigida and Larzx leptolepis do not burn easily while leaving charcoal. In contrast, deciduous trees with Zoysia japonzca and Populus X tomentiglandulosu are quick to catch fire. As a result of the experiments, it is proved that cigarette light is a very dangerous cause of wild fire especially for dry grass like Zoysia gaponica.

  • PDF

Combustion Characteristics of the Quercus variabilis and Zelkova Serrata Dried at Room Temperature (자연 건조된 굴참나무와 느티나무의 연소특성)

  • Chung, Yeong-Jin;Kwon, In-Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.1
    • /
    • pp.96-101
    • /
    • 2010
  • One of the restriction of wood as building material is its combustibility. The purpose of this paper is to examine the combustion properties of the quercus variabilis and zelkova serrata which are dried at room temperature and meet the desirable characteristics for use of construction materials. The cone calorimeter (ISO 5660-1) was used to determine the heat release rate (HRR) and fire smoke index, as well as CO production and smoke obscuration. The $HRR_{mean}$ 77.94 kW/$m^2$ of the quercus variabilis at 50 kW/$m^2$ was high in comparison with $HRR_{mean}$ 13.06 kW/$m^2$ for the zelkova serrata. Furthermore, the quercus variabilis has high specific extinction area ($SEA_{mean}$), 41.11 $m^2$/kg compared with $SEA_{mean}$ 9.23 $m^2$/kg of zelkova serrata. Thease results are depend on the density of tested wood species. In addition, the quercus variabilis has high CO production rate compared with that of zelkova serrata. Also, zelkova serrata showed an increase of retardant properties attributed to char formation compared with that of quercus variabilis.

A Flashover Characteristics Due to Flames (화염으로 인한 전기적 섬락특성 변화)

  • Sohn, H.K.;Lee, H.K.;Han, H.J.;Park, I.P.;Oh, H.H.;Min, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.703-704
    • /
    • 2007
  • Most of the transmission lines in Korea pass through a mountains. The forest fire occurred in around the transmission lines make an accident such as flashover and faults in the power transmission lines. In spite of that risk, there are no research on the flashover characteristics by fires in electric discharge engineering in our country. This paper was mentioned about the relation between the flame and flashover characteristics. We were carried out simple test by using artificial flame generator and rod-plane or conductor-plane gaps. And we were summarized test results.

  • PDF

Characteristics of Breeding Bird Communities between Natural and Fired Forests in Ussuri, Russia (러시아 우수리 지역의 천연림과 산불피해림에서 번식기 조류 군집의 특성)

  • Lee, Woo-Shin;Rhim, Shin-Jae;Lee, Eun-Jae;Kurdiukov, Alexey
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.3
    • /
    • pp.279-283
    • /
    • 2009
  • This study was conducted to clarify the breeding bird communities between natural and fired forests in Verchneussuriisky Research Forest ($44^{\circ}$ 02' N, $134^{\circ}$ 10' E) Institute of Biology and Soil Science, Far-East Branch, Russian Academy of Science at Ussuri, Russia from 7 to 11 June 2008. Total 37 species of birds were recorded in both study sites. Luscinia cyane, Urosphena squameiceps, and Emberiza tristrami were most dominant species. In natural forest, 115 individuals of 32 species were observed and bird species diversity (H') was 3.13. Sixty two individuals of 29 species were recorded and bird species diversity was 3.12 in fired forest. Bush and Canopy nesting guilds were higher in natural forest than in fired forest. But hole nesting guild was higher in fired forest. In foraging guilds, canopy foraging guild was most dominant in both study site. Air and bush foraging guilds were higher in natural forest. The differences of bird communities would be caused by differences of habitat conditions between study sites.

Allometric Equations of Crown Fuel Biomass and Analysis of Crown Bulk Density for Pinus densiflora (소나무 수관 부위별 연료량 추정식 개발 및 수관연료밀도 분석)

  • Lee, Byung-Doo;Won, Myoung-Soo;Kim, Seon-Young;Yoon, Suk-Hee;Lee, Myung-Bo
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.3
    • /
    • pp.391-396
    • /
    • 2010
  • To analyze the characteristics of canopy fuel in Pinus densiflora stand, which is essential to assess the crown fire hazard, allometric equations for estimation of crown fuel biomass were developed by subjectively categorized crown fuel component and crown bulk density was analyzed by available fuel component categories. Ten trees were destructively sampled at Pinus densiflora stand in Mt. Palgong in Daegu and their crown fuels were weighed separately for each fuel category by size classes and by living and dead. Regression equations that estimate crown fuel load by diameter at breast height(D) or additional total height(H) were derived. The adjusted coefficient of determination values were the highest (${R^2}_{adj}$=0.835-0.996) and standard error of estimate were the lowest (SEE=0.074-0.638) in the allometric equation lnWt=${\alpha}+{\beta}lnD+{\gamma}lnH$ in average. However, in needles and small branches categories, the differences in ${R^2}_{adj}$ and SEE between equations were not significant. Crown bulk density (CBD), which was calculated by crown fuel load divided by crown volume, was 0.067 kg/$m^3$ in average when only needles were considered as available crown fuel and 0.097 kg/$m^3$ when needles and branches (0-0.5 cm diameter) were considered. The increments of CBD of needles and small branches were little even when diameter at breast height increased.

Preparation of EVA/Intumescent/Nano-Clay Composite with Flame Retardant Properties and Cross Laminated Timber (CLT) Application Technology (난연특성을 가지는 EVA/Intumescent/나노클레이 복합재료 제조 및 교호집성재(Cross Laminated Timber) 적용 기술)

  • Choi, Yo-Seok;Park, Ji-Won;Lee, Jung-Hun;Shin, Jae-Ho;Jang, Seong-Wook;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.73-84
    • /
    • 2018
  • Recently, the importance of flame retardation treatment technology has been emphasized due to the increase in urban fire accidents and fire damage incidents caused by building exterior materials. Particularly, in the utilization of wood-based building materials, the flame retarding treatment technology is more importantly evaluated. An Intumescent system is one of the non-halogen flame retardant treatment technologies and is a system that realizes flame retardancy through foaming and carbonization layer formation. To apply the Intumescent system, composite material was prepared by using Ethylene vinyl acetate (EVA) as a matrix. To enhance the flame retardant properties of the Intumescent system, a nano-clay was applied together. Composite materials with Intumescent system and nano - clay technology were processed into sheet - like test specimens, and then a new structure of cross laminated timber with improved flame retardant properties was fabricated. In the evaluation of combustion characteristics of composite materials using Intumescent system, it was confirmed that the maximum heat emission was reduced efficiently. Depending on the structure attached to the surface, the CLT had two stages of combustion. Also, it was confirmed that the maximum calorific value decreased significantly during the deep burning process. These characteristics are expected to have a delayed combustion diffusion effect in the combustion process of CLT. In order to improve the performance, the flame retardation treatment technique for the surface veneer and the optimization technique of the application of the composite material are required. It is expected that it will be possible to develop a CLT structure with improved fire characteristics.