• 제목/요약/키워드: Forensic service

검색결과 236건 처리시간 0.026초

유리 파손형상의 법과학적 해석 (Forensic Scientific Analysis for Glass Breakdown Patterns)

  • 송재용;사승훈;남정우;김동환;최영우;김진표;고재모;박남규
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.28-35
    • /
    • 2012
  • We investigated the breakdown patterns of silica glass under the various impacts by forensic scientific analysis. The impacts were chosen by thermal and projectiles impact stress. Thermal impacts under the fire were constructed by changing the position of the flame with gas torches. Physical impacts were constructed with the projectiles of slingshots and rifles by changing the size of the projectiles at the surfaces and the initial distance. Also we identified incident angles of the projectiles by analysis of the punching portion at the glass surface. Under the thermal impacts, the breakdown patterns were various by changing the position of the flame. Especially, the configuration of breakdown patterns had radial shape with the position of the flame at the center of the glass sheet. Under the physical impacts by the projectiles, the breakdown patterns had always radial shape.

수도권 부검시료에서 중독사 관련 사용물질 현황(2014-2016) (Analysis of Death Due to Poisoning in the National Capital Region (2014-2016))

  • 박미정;박종신;이상기;인상환
    • 대한임상독성학회지
    • /
    • 제15권2호
    • /
    • pp.101-106
    • /
    • 2017
  • Purpose: This study examined the patterns of drugs, poisons, and chemicals detected in autopsy samples performed in the Seoul Institute and other regional forensic offices of the National Forensic Service (NFS) between 2014 and 2016. Methods: The investigation carried out using the laboratory information management system. Forensic toxicological identification and quantitation were performed in autopsy samples, including heart blood, peripheral blood, liver, kidney, vitreous humor and etc. Gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were used to analyze the drugs and poisons. Results: Forensic autopsies were performed on 9,674 cases in this period. Based on the autopsy reports, 699 cases (7.2%) were considered as unnatural deaths caused by fatal intoxication. The number of male deaths was higher than that of female deaths, with the age of 50-59 being the most common age group. Conclusion: Drugs comprised the largest number of deaths due to poison, followed by alcohol, agrochemicals, drug with alcohol, carbon monoxide, and cyanide, in that order. Zolpidem was the most frequently used drug in all drug-related intoxication cases.

Validation of Reduced-volume Reaction in the PowerQuant® System for human DNA Quantification

  • Kim, Hyojeong;Cho, Yoonjung;Kim, Jeongyong;Lee, Ja Hyun;Kim, Hyo Sook;Kim, Eungsoo
    • 대한의생명과학회지
    • /
    • 제26권4호
    • /
    • pp.275-287
    • /
    • 2020
  • Since its introduction in the forensic field, quantitative PCR (qPCR) has played an essential role in DNA analysis. Quality of DNA should be evaluated before short tandem repeat (STR) profiling to obtain reliable results and reduce unnecessary costs. To this end, various human DNA quantification kits have been developed. Among these kits, the PowerQunat® System was designed not only to determine the total amount of human DNA and human male DNA from a forensic evidence item, but also to offer data about degradation of DNA samples. However, a crucial limitation of the PowerQunat® System is its high cost. Therefore, to minimize the cost of DNA quantification, we evaluated kit performance using a reduced volume of reagents (1/2-volume) using DNA samples of varying types and concentrations. Our results demonstrated that the low-volume method has almost comparable performance to the manufacturer's method for human DNA quantification, human male DNA quantification, and DNA degradation index. Furthermore, using a reduced volume of regents, it is possible to run 2 times more reactions per kit. We expect the proposed low-volume method to cut costs in half for laboratories dealing with large numbers of DNA samples.

A Review of Extended STR Loci and DNA Database

  • Cho, Yoonjung;Lee, Min Ho;Kim, Su Jin;Park, Ji Hwan;Jung, Ju Yeon
    • 대한의생명과학회지
    • /
    • 제28권3호
    • /
    • pp.157-169
    • /
    • 2022
  • DNA typing is the typical technology in the forensic science and plays a significant role in the personal identification of victims and suspects. Short tandem repeat (STR) is the short tandemly repeated DNA sequence consisting of 2~7 bp DNA units in specific loci. It is disseminated across the human genome and represents polymorphism among individuals. Because polymorphism is a key feature of the application of DNA typing STR analysis, STR analysis becomes the standard technology in forensics. Therefore, the DNA database (DNA-DB) was first introduced with 4 essential STR markers for the application of forensic science; however, the number of STR markers was expanded from 4 to 13 and 13 to 20 later to counteract the continuously increased DNA profile and other needed situations. After applying expanded STR markers to the South Korean DNA-DB system, it positively affected to low copy number analysis that had a high possibility of partial DNA profiles, and especially contributed to the theft cases due to the high portion of touch DNA evidence in the theft case. Furthermore, STR marker expansion not only contributed to the resolution of cold cases but also increased kinship index indicating the potential for improved kinship test accuracy using extended STR markers. Collectively, the expansion of the STR locus was considered to be necessary to keep pace with the continuously increasing DNA profile, and to improve the data integrity of the DNA-DB.

Application study of PCR additives to improve the split peaks in direct PCR

  • Kim, Joo-Young;Kim, Da-Hye;Park, Hyun-Chul;Jung, Ju Yeon;Jin, Gang-Nam;Hwang, In-Kwan;Kang, Pil-Won
    • 분석과학
    • /
    • 제32권4호
    • /
    • pp.155-162
    • /
    • 2019
  • Analysis techniques using DNA profiling are widely used in various fields including forensic science and new technologies such as the Direct PCR amplification method are being developed continuously in order to acquire the DNA profiles efficiently. However, it has a limits such as non-specific amplification according to the quality of crime scene evidence samples. Especially, split peaks caused by excessive DNA samples are one of the important factors that could cause the debate to allow researchers to interpret the DNA profile results. In this study, we confirmed the occurrence rate of split peaks in each STR (short tandem repeats) locus of the $GlobalFiler^{TM}$ kit and investigated the possibility of improving the split peaks using several PCR additives such as DMSO (dimethylsulfoxide), $MgCl_2$, Betaine and Tween-20. As a result, we could make three groups according to the occurrence rate of split peaks in Direct PCR and it was confirmed that the ratio of split peaks could be reduced by DMSO (87.4 %), $MgCl_2$ (84.5 %) and Betaine (86.1 %), respectively. These results indicate that PCR additives such as DMSO, $MgCl_2$ and Betaine can be improve the split peaks in Direct PCR and thereby facilitate subsequently a successful DNA profile results.

스타트모터 B단자 절연파괴 화재사례에 대한 실험적 연구 (A experimental Study on Insulation Breaking Fire Case of Starter Motor B Terminal)

  • 우승우;박정만;현병수;남정우;박우식;김진표;조영진;고재모;박남규
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.55-62
    • /
    • 2019
  • In this paper, we introduce a case of a fire accident during parking of a large truck that is repeatedly occurring. The shape and location of the combustion and electrical singularity commonly found in other vehicle fire accidents could limit the starter motor as the ignition section. In addition, it was possible to confirm the electrical melting singularity that could act as a cause of ignition between the start motor B terminal and the start motor enclosure. By combining the above investigations and investigations, it was possible to estimate the electric fire expressed from insulation breaking of the starter motor B terminal, and by using the renewable starter motor comparison product mounted on the fire vehicle, an experiment was performed to reproduce the ignition process from the starter motor under specific conditions. So. It is hoped that this will raise awareness about vehicle fires, which can lead to large fires or casualties, share the risks of using starter motors for regeneration, and help in the rapid and accurate investigation of similar vehicle fires in the future.

HS-SPME-GC/MS에 의한 혈액중 17종 유기인계 농약의 동시분석법 (Simultaneous Analysis of 17 Organophosphorous Pesticides in Blood by Automated Head Space-SPME GC/MS)

  • 이종숙;정진미;이한선;염혜선;이상기;박유신;정희선
    • 약학회지
    • /
    • 제54권6호
    • /
    • pp.429-440
    • /
    • 2010
  • HS-SPME-GC/MS was studied and optimized for the determination of 17 orgarnophosphorous pesiticides (OPPs: chlorpyrifos, chlorpyrifos-methyl, demeton-s-methyl, diazinon, dimethoate, EPN, fenitrothion, fenthion, malathion, methidathion, monocrotophos, parathion, phenthoate, phosphamidon, sulfotep, terbufos, triazophos) in blood. Optimum SPME parameters were selected: choice of SPME fiber (85 ${\mu}m$ polyacrylate), pH effect (0.5 N HCl), salt effect ($Na_2SO_4$, 0.2 g; 20%), headspace incubation temperature ($80^{\circ}C$), headspace incubation time (1 min), headspace adsorption time (30 min) and GC desorption time (2 min). These parameters were optimized using HS-SPME autosampler coupled with gas chromatography-mass spectrometry (GC-MS). Method validation was carried out in terms of linearity, limit of detection (LOD), limit of quantitation (LOQ) and recovery in blood. The assay was linear over 0.5~5.0 mg/l ($r^2$=0.955~1.000). Limit of detection (LOD) and limit of quantitation (LOQ) in blood were determined 0.03~0.3 mg/l (S/N=3) and 0.1~1.1 mg/l (S/N=10), respectively. Relative recovery with 0.5, 1 and 5 mg/l (in blood) were 90.8%, 98.5% and 94.1%, respectively. This method will be applied to the determination of the orgarnophosphorous pesticides in postmortem blood. The proposed protocol can be an attractive alternative to be used in routine toxicological analysis.

성충동약물치료 시행에 따른 소변 중 남성호르몬의 분석법 확립 (Validation of Analytical Method for Male Sex Hormone Monitoring in Urine due to the Chemical Castration)

  • 정수진;백승경;박선혜;손꽃잎;박용훈;이상기
    • 약학회지
    • /
    • 제57권5호
    • /
    • pp.330-336
    • /
    • 2013
  • "The Act on Medication Treatment of Sexual Impulse of Sex Offenders" known as chemical castration has been effective since July 2011 in Korea. According to the law, monitoring of male sex hormone in urine is enforced to request National Forensic Service more than once a month after injection of medicine designed to reduce sex impulse. We established a rapid and sensitive method for the monitoring of testosterone (T) and epitestosterone (E) in human urine by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Three mL of urine was pretreated by solid-phase extraction for purification and performed enzymatic hydrolysis. The pretreated samples were extracted twice with 2 ml of ethyl acetate and n-hexane (2 : 3). The separation was applied on Thermo Hypersil GOLD C18 column ($1.9{\mu}m$, $100{\times}2.1mm$). A gradient elution of methanol and water of 0.1% formic acid were used as mobile phase and the retention time was less than 10 min. LC-MS/MS system coupled with an electrospray ionization source was performed in multiple reaction monitoring mode. The transitions of the analytes executed as following: m/z $289{\rightarrow}97$, 109 for T and E, m/z $292{\rightarrow}109$ for $T-d_3$ and $E-d_3$ as internal standards. The validation results of the method were satisfactory. The limits of detection were 0.05 ng/ml and the limits of quantification were 0.1 ng/ml. This method was successfully applied to real human urine sample. The developed method will be useful for monitoring T/E ratio in urine of sex offenders.