• Title/Summary/Keyword: Forced circulation

Search Result 89, Processing Time 0.025 seconds

Performance analysis of a cold-air forced circulation type showcase (냉기 강제순환형 공랭식 쇼케이스 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1003-1010
    • /
    • 2013
  • In this study, a simulation program was developed, which predicts the performance of cold-air forced circulation type air cooled showcase. The showcase has an excellent display effect in addition to preserving the grocery. In the program, the compressor was analyzed using performance data supplied by the manufacturer and the capillary tube pressure drop was analyzed using a homogeneous model. The evaporator and condenser were analyzed by dividing the heat exchangers into small elements, where energy balance and appropriate heat transfer correlations were used. A showcase model with two 3/4 HP compressors, capillary tubes of 1.6 mm inner diameter, a fin-and-tube evaporator and condenser was tested, and the results are compared with the predicted values. It is shown that both evaporation and condensation temperatures are adequately predicted by the program.

A Study on the Streaming Electrifacation in Forced Oil Cooled Transformer (강제유 냉각 변압기의 유동계전에 관한 연구)

  • 권동진;강창구;곽희로;김재철
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.53-56
    • /
    • 1990
  • When oil flows and rubs against various materials in transformer, electrostatic charges are separated at the interface of the oil and the solid material. Using simplified model transformer, authors investigated the basic characteristics of the streaming electrifica-tion which is caused by forced oil circulation. As the result of the study, it was concluded that the electrostatic charge distribution on test pipe of the transformer showed larger leakage current at the inlet and the outlet.

  • PDF

Circulations in Coastal Areas off South China

  • Ye, Longfei
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.62-65
    • /
    • 1995
  • Understanding the flow circulation is of primary importance for studies of marine ecology and Pollution protection etc. However the circulation in coastal area is complicated with various processes and can not be considered as forced only by tides. The coastal area off South China is now playing an important role in economic development in southeast Asia with Hong Kong, Macao, Guangzhou and other cities situated in its central part (Fig. 1). (omitted)

  • PDF

A Study on the Visitor's Circulation of Exhibition Space in Museum (박물관의 순회형식과 관람동선에 관한 연구)

  • 신미경;임채진
    • Korean Institute of Interior Design Journal
    • /
    • no.5
    • /
    • pp.24-29
    • /
    • 1995
  • Entering into the modern society, the discussion on the role played by and the social position held by museums are forced to take into account the visitors, that is, the general public being real consumers of culture in accord-ance with the enlargement of the study of the visi-tors. The study of a museum has been developed with priori-ty given to the architectural study and exhibition space, but the study of the form of circulation of visitors using the museum is believed to have put an emphasis on the rough form of circulation on the basis of the general and basic theory and the particulars while the discussions on the more concrete method of study and its application are excluded as a basis of approaching in details to exhi-bition plans or producing plans. Consequently, the purpose of the study is to under-stand the problems in the form of circulation in the exist-ing exhibition rooms, and to infer the planning principles of interior design with priority given to the problems in space composition, details of exhibitions, the points in method, recognitions by visitors and the relation of path line as a way of resolving the problem.

  • PDF

Development of Bubble Detector for Extracorporeal Circulation Support System (체외 순환 보조 장치 위한 공기방울 감지 장치 개발)

  • Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.4
    • /
    • pp.298-302
    • /
    • 2010
  • Extracorporeal circulation support system is a device for repiratory and heart failure treatment, and there have been many trials for development and clinical application in the world. These devices need to be careful while using is air embolism. Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity or using extracorporeal circulation support system. To solve the problem, we developed the air detector using relative dielectric constant change. In experiments with a mock circulation system, the proposed system showed a signal difference depending on the amount of air in the tube.

Optimization of an extra vessel electromagnetic pump for Lead-Bismuth eutectic coolant circulation in a non-refueling full-life small reactor

  • Kang, Tae Uk;Kwak, Jae Sik;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3919-3927
    • /
    • 2022
  • This study presents an optimal design of the coolant system of a non-refueling full-life small reactor by analyzing the space-integrated geometrical and electromagnetic variables of an extra vessel electromagnetic pump (EVEMP) for the circulation of a lead-bismuth eutectic (LBE) coolant. The EVEMP is an ideal alternative to the thermal-hydraulic system of non-refueling full-life micro reactors as it possesses no internal structures, such as impellors or sealing structures, for the transportation of LBE. Typically, the LBE passes through the annular flow channel of a reactor, is cooled by the heat exchanger, and then circulates back to the EVEMP flow channel. This thermal-hydraulic flow method is similar to natural circulation, which enhances thermal efficiency, while providing a golden time for cooling cores in the event of an emergency. When the forced circulation technology of the EVEMP was applied, the non-refueling full-life micro reactor achieve an output power of 60 MWt, which is higher than that achievable via the natural circulation method (30 MWt). Accordingly, an optimized EVEMP for Micro URANUS with a flow rate of 4196 kg/s and developed pressure of 73 kPa under a working temperature of 250 ℃ was designed.

Modification of Wind Generated Coastal Circulation Model (풍성연안순환모델의 수정)

  • Lee, J. W.;Shin, S. H.;Kim, J. Y.;Yang, S. Y.
    • Journal of Korean Port Research
    • /
    • v.9 no.2
    • /
    • pp.25-38
    • /
    • 1995
  • The wind generated circulation model describes the phenomenon based on the following physical assumptions: a) As the horizontal dimension of the flow domain is several orders of magnitude larger than vertical dimension, nearly horizontal flow is realistic. b) The time taken for circulation to develop may effect on the flow domain of the earth's rotation, the contribution of the Coriolis force. c) A flow domain of large dimension results in quite large Reynolds number and the Reynolds stresses are approximated by the turbulent mean velocity gradient. d) The circulation is forced by the shear stresses on the water surface exercised by the wind. Modification made to the depth average approximation of the convective terms and the bed shear stress terms by adopting a certain distribution of current over the depth and laboratory measurements for the bed shear expression. Modification circulation patterns, energy evolution and surface profile gave the significant differences comparing with the classical model results. The modified model results in higher free surface gradients balancing both the free surface shear and the bed shear and consequently to higher surface profiles along the coast.

  • PDF

HWR Shield Cooling Natural Circulation Study (원자로 차폐체 자연순환냉각에 관한 연구)

  • Shin, Jung-Chul
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.221-227
    • /
    • 2012
  • The CANDU 9 shield cooling system was designed and layout with the objective of promoting natural circulation on loss of forced flow. In the present study, the shield cooling natural circulation was analyzed using verified the thermal-hydraulic code when the coolant pump or the heat exchanger was lost. This study showed that thermosyphoning cooled the end shields and prevented the end shields and the reserve water tank from boiling for at least 8 hours on loss of the shield cooling pumps but the heat exchangers still operational. With the loss of both pumps and heat exchangers, the end shields remain subcooled for up to 4 hours. To enhance thermosyphoning, the bypass connection to the line from the reserve water tank should be relocated to a point as low as possible.

Validation of Ocean General Circulation Model (FMS-MOM4) in Relation with Climatological and Argo Data

  • Chang, You-Soon;Cho, Chang-Woo;Youn, Yong-Hoon;Seo, Jang-Won
    • Journal of the Korean earth science society
    • /
    • v.28 no.5
    • /
    • pp.545-555
    • /
    • 2007
  • Ocean general circulation model developed by GFDL on the basis of MOM4 of FMS are examined and evaluated in order to elucidate the global ocean status. The model employs a tripolar grid system to resolve the Arctic Ocean without polar filtering. The meridional resolution gradually increases from $1/3^{\circ}$ at the equator to $1^{\circ}$ at $30^{\circ}N(S)$. Other horizontal grids have the constant $1^{\circ}$ and vertical grids with 50 levels. The ocean is also coupled to the GFDL sea ice model. It considers tidal effects along with fresh water and chlorophyll concentration. This model is integrated for a 100 year duration with 96 cpu forced by German OMIP and CORE dataset. Levitus, WOA01 climatology, serial CTD observations, WOCE and Argo data are all used for model validation. General features of the world ocean circulation are well simulated except for the western boundary and coastal region where strong advection or fresh water flux are dominant. However, we can find that information concerning chlorophyll and sea ice, newly applied to MOM4 as surface boundary condition, can be used to reduce a model bias near the equatorial and North Pacific ocean.

Pulmonary Function Following Open Heart Surgery -early and late postoperative changes- (개심술후 폐기능 -수술직후 및 장기간의 추이에 대하여-)

  • 이성행
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.364-374
    • /
    • 1980
  • Twenty-two patients were selected for evaluation of pre-and postoperative pulmonary function. These patients were performed open cardiac surgery with the extracorporeal circulation from March 1979 to July 1980 at the Department of Thoracic and Cardiovascular Surgery, Kyungbook National University Hospital. Patients were classified with ventricular septal defect 5 cases, atrial septal defect 5 cases, tetralogy of Fallot 5 cases, mitral stenosis 4 cases, rupture of aneurysm of sinus Valsalva 1 case, left atrial myxoma I case, and aortic insufficiency 1 case. The pulmonary function tests were performed and listed: [1] respiratory rate, tidal volume [TV], and minute volume[MV], [2] forced vital capacity [FVC] and forced expiratory volume[FEV 0.5 & FEV 1.0], [3] forced expiratory flow [FEF 200-1200 ml & FEF 25-75%]. [4] Maximal voluntary ventilation [MVV], [5] residual volume [RV] and functional residual capacity[FRC], measured by a helium dilution technique. Respiratory rate increased during the early postoperative days and tidal volume decreased significantly. These values returned to the preoperative levels after postoperative 5-6 days. Minute volume decreased slightly, but essentially unchanged. Preoperative mean values of the forced vital capacity, functional residual capacity and total lung capacity decreased [63.2%, 87.2% & 77.3% predicted, respectively], and early postoperatively these values decreased further [19.6%, 76.0% & 38.0% predicted], but later progressively increased to the preoperative levels. In residual volume, there was no decline in the preoperative mean values [100.9% predicted] and postoperatively the value rather increased [106.3-161.7% predicted]. Forced expiratory volume [FEV 0.5 & FEV 1.0] and forced expiratory flow [FEF 200-1200 ml & FEF 25-75%] also revealed significant declines in the early postoperative period. There was no significant difference in values of the spirometric pulmonary function tests, such as FEF 1.O and FEF 25-75% between successful weaning group [17 cases] extubated within 24 hrs post-operatively and unsuccessful weaning group [5 cases] extubated beyond 24 hrs. Static compliance and airway resistance measured for the two cases during assisted ventilation, however, any information was not obtained. Long term follow-up pulmonary function studies were carried out for 8 cases in 9 months post-operatively. All of the results returned to the pre-operative or to normal predicted levels except FVC, FEV 1.0, and FEF 25-75% those showed minimal declines compared to the pre-operative figures.

  • PDF