• Title/Summary/Keyword: Force-matching

Search Result 83, Processing Time 0.033 seconds

Effect of Fatigue on Force-Matching in the Quadriceps Muscle

  • Song, Young-Hee;Lee, Su-Young;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.13 no.4
    • /
    • pp.10-15
    • /
    • 2006
  • This study examined the ability of human subjects to match a force in their quadriceps muscle during fatigue. Twenty subjects (mean age: 23.4 yrs, mean height: 167.8 cm, mean weight, 62.6 kg) were enrolled in the experiment. In the force-matching task, the quadriceps muscle generated 50% of the MVIC (maximum voluntary isometric contraction) torque under visual control and then without visual feedback. After inducing fatigue in the quadriceps muscle, the subjects were required to match 50% of the MVIC torque without visual feedback. The perceived magnitude of the force and force-matching errors were measured. 50% of the MVIC torque was perceived from 39.96 Nm in the pre-fatigue condition to 44.95 Nm in the post-fatigue condition. 50% of the MVIC torque-matching errors increased significantly from .55% in the pre-fatigue condition to 9.6% in the post-fatigue condition (p<.001). in addition, there were significantly more force-matching errors in women than in men (p<.01). In conclusion muscle fatigue can interfere with a subject's ability to match a force. This suggests that muscle fatigue may contributes to the sensitization of the proprioception.

  • PDF

Development of a Measurement System for the Surface Shape of Micro-parts by Using Atomic Force Microscope (원자간력 현미경을 이용한 초소형 마이크로 부품 표면 형상 측정 시스템 개발)

  • Hong Seong-Wook;Ko Myung-Jun;Shin Young-Hyun;Lee Deug-Woo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.6
    • /
    • pp.22-30
    • /
    • 2005
  • This paper proposes a measurement method for the surface shape of micro-parts by using an atomic force microscope(AFM). To this end, two techniques are presented: First, the measurement range is expanded by using an image matching method based on correlation coefficients. To account for the inaccuracy of the coarse stage implemented in AFM, the image matching technique is applied to two neighboring images intentionally overlapped with each other. Second, a method to measure the shape of relatively large specimen is proposed that utilizes the inherent trigger mechanism due to the atomic force. The proposed methods are proved effective through a series of experiments.

Development of a measurement system for the surface of micro-parts (초소형 마이크로 부품 표면 측정 시스템 개발)

  • Hong Seong-Wook;Ko Myung-Jun;Shin Young-Hyun;Lee Deug-Woo
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.413-418
    • /
    • 2005
  • This paper proposes a measurement method for the surface of micro-parts by using AFM(Atomic Force Microscope). To this end, two techniques are presented to extend the capacity of AFM. First, the measurement range is extended by using an image matching method based on correlation coefficients. To account for the inaccuracy of the coarse stage implemented in AFM's, the image matching technique is applied to two neighboring images intentionally overlapped with each other. Second, a method to measure the shape of relatively large specimen is presented by using the inherent trigger mechanism due to the atomic force. The proposed method is proved effective through a series of experiments.

  • PDF

Improved algorithm for measurement area expansion of atomic force microscope using Image pyramid method (영상 피라미드법을 이용한 원자간력 현미경의 측정면적 확대 알고리즘 개선)

  • Ko M.J.;Seo Y.K.;Hong S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.483-484
    • /
    • 2006
  • This paper introduces an improved surface matching algorithm that can be used to reconstruct the surface topography of an object that is scanned from multiple overlapping regions by an AFM. The essence of the image matching technique is stitching two neighboring images intentionally overlapped with each other. To enhance the computational efficiency, this paper introduces a pyramid matching algorithm which makes use of reduced images for primary images. The results show that the proposed image pyramid matching algorithm is useful fer enhancing the computational efficiency.

  • PDF

Development of Image Matching Algorithm to Expand Measuring Area of Atomic Force Microscope (원자간력 현미경의 측정면적 확대를 위한 영상정합 알고리즘 개발)

  • Ko M.J;Patrangenaru V.;Hong S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.568-571
    • /
    • 2005
  • This paper introduces a correlation-based surface matching algorithm that can be used to reconstruct the surface topography of an object that is scanned from multiple overlapping regions by an AFM. The image matching technique is applied to two neighboring images intentionally overlapped with each other. To account for the inaccuracy of the coarse stage implemented in AFM, all the six axes including the rotational degrees of freedom are successively matched to maximize the correlation coefficient. The results show that the proposed 6-axes image matching method is useful for expanding the measurement range of AFM.

  • PDF

Force monitoring of steel cables using vision-based sensing technology: methodology and experimental verification

  • Ye, X.W.;Dong, C.Z.;Liu, T.
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.585-599
    • /
    • 2016
  • Steel cables serve as the key structural components in long-span bridges, and the force state of the steel cable is deemed to be one of the most important determinant factors representing the safety condition of bridge structures. The disadvantages of traditional cable force measurement methods have been envisaged and development of an effective alternative is still desired. In the last decade, the vision-based sensing technology has been rapidly developed and broadly applied in the field of structural health monitoring (SHM). With the aid of vision-based multi-point structural displacement measurement method, monitoring of the tensile force of the steel cable can be realized. In this paper, a novel cable force monitoring system integrated with a multi-point pattern matching algorithm is developed. The feasibility and accuracy of the developed vision-based force monitoring system has been validated by conducting the uniaxial tensile tests of steel bars, steel wire ropes, and parallel strand cables on a universal testing machine (UTM) as well as a series of moving loading experiments on a scale arch bridge model. The comparative study of the experimental outcomes indicates that the results obtained by the vision-based system are consistent with those measured by the traditional method for cable force measurement.

Impedance Matching Characteristic Research Utilizing L-type Matching Network

  • Jun Gyu Ha;Bo Keun Kim;Dae Sik Junn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.2
    • /
    • pp.64-71
    • /
    • 2023
  • If an impedance mismatch occurs between the source and load in a Radio Frequency transmission system, reflected power is generated. This results in incomplete power transmission and the generation of Reflected Power, which returns to the Radio Frequency generator. To minimize this Reflected Power, Impedance matching is performed. Fast and efficient Impedance matching, along with converging reflected power towards zero, is advantageous for achieving desired plasma characteristics in semiconductor processes. This paper explores Impedance matching by adjusting the Vacuum Variable Capacitor of an L-type Matching Module based on the trends observed in the voltage of the Phase Sensor and Electromotive Force voltage. After assessing the impedance matching characteristics, the findings are described.

  • PDF

Estimation of the Matching Function in Korea by Mitigating Endogeneity Problems (내생성 문제를 완화한 한국의 매칭함수 추정)

  • Kim, Jiwoon
    • Journal of Labour Economics
    • /
    • v.43 no.2
    • /
    • pp.109-133
    • /
    • 2020
  • This paper estimates a matching function in Korea by using the method of Borowczyk-Martins et al. (2013) in order to mitigate endogeneity problems. The endogeneity was controlled through the GMM estimation by approximating the unobserved matching efficiency with the ARMA(p,q) process. The monthly data from the Economically Active Population Survey and Labor Force Survey at Establishments from June 2009 to December 2019 were used for the estimation. The matching elasticity that indicates the elasticity of new hires with respect to vacancies was estimated to be 0.859. When excluding 2019 samples, which had a large number of direct jobs provided by the government, the matching elasticity was lowered to 0.755, but still higher than that of other countries.

  • PDF

Experimental Demonstration of Enhanced Transmission Due to Impedance-matching Si3N4 Layer in Perforated Gold Film

  • Park, Myung-Soo;Yoon, Su-Jin;Hwang, Je-Hwan;Kang, Sang-Woo;Kim, Deok-kee;Ku, Zahyun;Urbas, Augustine;Lee, Sang Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.359-359
    • /
    • 2014
  • In this study, surface plasmon resonance structures for the selective and the enhanced transmission of infrared light were designed. In order to relieve the large discontinuity of refractive index between air and metal hole array, $Si_3N_4$ was used as the impedance matching layer. Experimental parameter were calculated and determined in advance by the rigorous coupled wave analysis (RCWA) simulation, and then the experiment was carried out. A 2-dimensional metal hole array structures were patterned on the size of $1{\times}1cm^2$ GaAs substrate using photolithography process, and 5 nm thick Ti, 50 nm thick Au were deposited by E-beam evaporator, respectively. Subsequently, $Si_3N_4$ films with various thicknesses (150, 350, 550, and 750 nm) were deposited by plasma enhanced chemical vapor deposition (PECVD). For the comparison, transmittance of specimens with and without $Si_3N_4$ was measured using Fourier transform infrared spectroscopy (FTIR) in the range of $2.5-15{\mu}m$. Furthermore, the surface and the cross-sectional images were collected from the specimens by scanning electron microscopy (SEM). From the results, it was demonstrated that the transmittance was enhanced up to 80% by the deposition of 750 nm $Si_3N_4$ at $6.23{\mu}m$. It has advantage of enhanced transmission despite the simple fabrication process.

  • PDF